Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 83(10): 103507, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126766

RESUMO

A two channel oblique electron cyclotron emission (ECE) radiometer was installed on the DIII-D tokamak and interfaced to four gyrotrons. Oblique ECE was used to toroidally and radially localize rotating magnetic islands and so assist their electron cyclotron current drive (ECCD) stabilization. In particular, after manipulations operated by the interfacing analogue circuit, the oblique ECE signals directly modulated the current drive in synch with the island rotation and in phase with the island O-point, for a more efficient stabilization. Apart from the different toroidal location, the diagnostic view is identical to the ECCD launch direction, which greatly simplified the real-time use of the signals. In fact, a simple toroidal extrapolation was sufficient to lock the modulation to the O-point phase. This was accomplished by a specially designed phase shifter of nearly flat response over the 1-7 kHz range. Moreover, correlation analysis of two channels slightly above and below the ECCD frequency allowed checking the radial alignment to the island, based on the fact that for satisfactory alignment the two signals are out of phase.

2.
Rev Sci Instrum ; 83(10): 10E343, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23127000

RESUMO

Validation of models of pedestal structure is an important part of predicting pedestal height and performance in future tokamaks. The Thomson scattering diagnostic at DIII-D has been upgraded in support of validating these models. Spatial and temporal resolution, as well as signal to noise ratio, have all been specifically enhanced in the pedestal region. This region is now diagnosed by 20 view-chords with a spacing of 6 mm and a scattering length of just under 5 mm sampled at a nominal rate of 250 Hz. When mapped to the outboard midplane, this corresponds to ~3 mm spacing. These measurements are being used to test critical gradient models, in which pedestal gradients increase in time until a threshold is reached. This paper will describe the specifications of the upgrade and present initial results of the system.

3.
Rev Sci Instrum ; 81(10): 10D525, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033880

RESUMO

The DIII-D Thomson scattering system has been upgraded. A new data acquisition hardware was installed, adding the capacity for additional spatial channels and longer acquisition times for temperature and density measurements. Detector modules were replaced with faster transimpedance circuitry, increasing the signal-to-noise ratio by a factor of 2. This allows for future expansion to the edge system. A second phase upgrade scheduled for 2010-2011 includes the installation of four 1 J/pulse Nd:YAG lasers at 50 Hz repetition rate. This paper presents the first completed phase of the upgrade and performance comparison between the original system and the upgraded system. The plan for the second phase is also presented.

4.
Rev Sci Instrum ; 79(10): 10E719, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044536

RESUMO

A tangential viewing, 10.59 microm CO(2) laser polarimeter for electron density measurements based on plasma induced Faraday rotation has been installed on DIII-D. The system uses colinear right- and left-hand circularly polarized beams with a difference frequency of 40 MHz to generate the necessary signal for heterodyne phase detection. The high-resolution phase information required to adequately resolve degree level polarization rotation is obtained using an all-digital "real-time" phase demodulation scheme based on modern digital signal processing techniques. Initial application of the system to DIII-D disruption mitigation experiments utilizing "massive gas jet" injection exhibits reliable operation and excellent agreement with CO(2) interferometer measurements; interestingly, the obtained Faraday rotation angles are in the range of those expected in ITER plasmas.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA