Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
2.
Case Reports Hepatol ; 2023: 6637890, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37503330

RESUMO

Background. Ciliated hepatic foregut cyst (CHFC) is a rare, benign cyst of the liver, derived from the embryonic foregut epithelium. Although CHFCs are typically asymptomatic, some present with nonspecific abdominal symptoms. Imaging modalities alone are insufficient for diagnosis, with intrahepatic cholangiocarcinoma included in the differential due to nonspecific imaging features; definitive diagnosis relies on histologic confirmation. These lesions are often benign; however, larger lesions can have malignant transformation into squamous cell carcinoma (SCC), which carries a poor prognosis, thus making a definitive diagnosis, no matter what size, essential. Here, we present a case of CHFC as well as a comprehensive literature review. Given these data, we propose an algorithm for definitive diagnosis.

3.
Clin Imaging ; 100: 30-35, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37187107

RESUMO

PURPOSE: To access if the (MC)2 scoring system can identify patients at risk for major adverse events following percutaneous microwave ablation of renal tumors. METHODS: Retrospective review of all adult patients who underwent percutaneous renal microwave ablation at two centers. Patient demographics, medical histories, laboratory work, technical details of the procedure, tumor characteristics, and clinical outcomes were collected. The (MC)2 score was calculated for each patient. Patients were assigned to low-risk (<5), moderate-risk (5-8) and high-risk (>8) groups. Adverse events were graded according to the criteria from the Society of Interventional Radiology guidelines. RESULTS: A total of 116 patients (mean age = 67.8 [95%CI 65.5-69.9], 66 men) were included. 10 (8.6%) and 22 (19.0%) experienced major or minor adverse events, respectively. The mean (MC)2 score for patients with major adverse events (4.6 [95%CI 3.3-5.8]) was not higher than those with either minor adverse events (4.1 [95%CI 3.4-4.8], p = 0.49) or no adverse events (3.7 [95%CI 3.4-4.1], p = 0.25). However, mean tumor size was greater in those with major adverse events (3.1 cm [95%CI 2.0-4.1]) than minor adverse events (2.0 cm [95%CI 1.8-2.3], p = 0.01). Patients with central tumors were also more likely to experience major adverse events compared to those without central tumors (p = 0.02). The area under the receiver operator curve to predict major adverse events was 0.61 (p = 0.15), indicating a poor ability of the (MC)2 score to predict major adverse events. CONCLUSION: The (MC)2 risk scoring system does not accurately identify patients at risk for major adverse events from percutaneous microwave ablation of renal tumors. The mean tumor size and central tumor location may serve as a better indicator for risk assessment of major adverse events.


Assuntos
Carcinoma de Células Renais , Ablação por Cateter , Neoplasias Renais , Ablação por Radiofrequência , Adulto , Masculino , Humanos , Idoso , Carcinoma de Células Renais/patologia , Micro-Ondas/uso terapêutico , Neoplasias Renais/cirurgia , Neoplasias Renais/patologia , Rim/diagnóstico por imagem , Rim/cirurgia , Rim/patologia , Estudos Retrospectivos , Ablação por Cateter/métodos , Resultado do Tratamento
4.
Health Phys ; 124(3): 200-207, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36719935

RESUMO

ABSTRACT: Prostate artery embolization is a minimally invasive treatment for benign prostatic hyperplasia, and imaging is indispensable for the technical success of this procedure; however, imaging is a major source of radiation exposure for patients and healthcare providers. Radiation emission during prostate artery embolization procedures at a single institution was evaluated to determine radiation exposure with the goal to work toward minimizing exposure. All patients at a single institution that underwent outpatient unilateral/bilateral prostate artery embolization between 4 January 2019 and 16 November 2021 were retrospectively evaluated; data collected included body mass index, prostate volume, and indications for prostate artery embolization. Technical parameters recorded were air kerma, procedure time, fluoroscopy time, number of acquisitions, and intra-procedural imaging modalities. Fisher's t-test, ANOVA, and chi-square analyses were used as appropriate for statistical analysis (P < 0.05). Overall, 56 patients were included in the study. Body mass index (obesity; P = 0.0017) was a significant predictor of increased air kerma; prostate size and bilateral vs. unilateral prostate artery embolization were not significantly associated with increased air kerma despite the number of acquisitions being significantly different between bilateral and unilateral embolization (P = 0.0064). When evaluating radiation exposure during prostate artery embolization, increased body mass index significantly predicted increased air kerma. Contrary to the literature, the extent of embolization (bilateral vs. unilateral) was not associated with increased air kerma regardless of higher acquisitions and procedure time associated with bilateral prostate artery embolization. Increased radiation protection efforts should be considered for patients with higher body mass index to protect patients and practitioners.Health Phys. 124(0):000-000; 2023.


Assuntos
Embolização Terapêutica , Hiperplasia Prostática , Exposição à Radiação , Masculino , Humanos , Próstata/irrigação sanguínea , Hiperplasia Prostática/terapia , Hiperplasia Prostática/complicações , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Estudos Retrospectivos , Resultado do Tratamento , Artérias , Exposição à Radiação/efeitos adversos
7.
J Vasc Interv Radiol ; 33(10): 1184-1190, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35842028

RESUMO

PURPOSE: To compare the cost and outcomes of surgical and interventional radiology (IR) placement of totally implantable venous access devices (TIVADs) within a large regional health system to determine the service line with better outcomes and lower costs to the health system. MATERIALS AND METHODS: A retrospective review of all chest port placements performed in the operating room (OR) and IR suite over 12 months was conducted at a large, integrated health system with 6 major hospitals. Secondary electronic health record and cost data were used to identify TIVAD placements, follow-up procedures indicating port malfunction, early adverse events (within 1 month after the surgery), late adverse events (2-12 months after the procedure), and health system cost of TIVAD placement and management. RESULTS: For 799 total port placements included in this analysis, the rate of major adverse events was 1.3% and 1.9% for the IR and OR groups, respectively, during the early follow-up (P = .5655) and 4.9% and 2.8% for the IR and OR groups, respectively, during the late follow-up (P = .5437). Malfunction-related follow-up procedure rates were 1.8% and 2.6% for the IR and OR groups, respectively, during the early follow-up (P = .4787) and 12.4% and 10.5% for the IR and OR groups, respectively, during the late follow-up (P = .4354). The mean cost of port placement per patient was $4,509 and $5,247 for the IR and OR groups, respectively. The difference in per-patient cost of port placement was $1,170 greater for the OR group (P = .0074). CONCLUSIONS: The similar rates of adverse events and follow-up procedures and significant differences in insertion cost suggest that IR TIVAD placement may be more cost effective than surgical placement without affecting the quality.


Assuntos
Cateterismo Venoso Central , Cateterismo Venoso Central/efeitos adversos , Cateteres de Demora/efeitos adversos , Humanos , Salas Cirúrgicas , Radiologistas , Radiologia Intervencionista , Estudos Retrospectivos
8.
J Vasc Interv Radiol ; 33(6): 695-701, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35311666

RESUMO

PURPOSE: To assess the utility of the radius, exophytic/endophytic, nearness to collecting system or sinus, anterior/posterior, and location relative to polar lines (RENAL) nephrometry scoring system at predicting adverse events and outcomes in percutaneous microwave ablation (MWA) of renal tumors. MATERIALS AND METHODS: A retrospective review of 116 patients who underwent MWA from 2004 to 2018 at 2 large university hospitals was conducted. Patient demographics and tumor characteristics were collected. The RENAL nephrometry scores were calculated, and procedure-related adverse events were stratified into minor and major (the Society of Interventional Radiology classification of class C or higher). Technical and oncologic outcomes were based on follow-up magnetic resonance imaging and computed tomography scans after ablation. RESULTS: The mean RENAL score was 6.6 (range, 4-11), and the mean tumor size was 24 mm. Follow-up ranged between 16 and 161 weeks (median, 50 weeks; mean, 65 weeks). Oncologic control was achieved in 96% (n = 111) of patients. The major and minor adverse event rates were 8.6% (n = 10) and 17% (n = 19), respectively. The mean RENAL score for patients with recurrent and/or residual tumor (8.2 ± 2.7) was higher than that for patients without disease recurrence (6.5 ± 3.5, P = .05). However, in a multivariate analysis, the RENAL score was not found to be an independent predictor of oncologic outcomes (odds ratio, 1.548; P = .092). CONCLUSIONS: The RENAL nephrometry score has minimal utility for predicting outcomes and adverse events in MWA of renal tumors. The inconsistent nature of RENAL nephrometry scoring in percutaneous ablation procedures underscores the need for an ablation-specific risk stratification system.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Carcinoma de Células Renais/cirurgia , Humanos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/etiologia , Neoplasias Renais/cirurgia , Micro-Ondas/efeitos adversos , Recidiva Local de Neoplasia/cirurgia , Nefrectomia/efeitos adversos , Estudos Retrospectivos
10.
Am J Forensic Med Pathol ; 43(1): 76-80, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34510054

RESUMO

ABSTRACT: This case report describes fatal exsanguination due to splenic artery hemorrhage into a pancreatic pseudocyst with cystogastrostomy in a 46-year-old woman. The decedent had a complicated medical history including necrotizing pancreatitis, giant pseudocyst formation after cystogastrostomy procedure, and coiling of a hemorrhagic splenic artery. While hospitalized, she underwent embolization of a ruptured splenic artery pseudoaneurysm. Weeks later, she went into hemorrhagic shock and was ultimately pronounced at the hospital. Doctors suspected an upper gastrointestinal (GI) bleed as the cause of death; however, the patient was too unstable to undergo interventional radiology at the time.At autopsy, the pancreas was hemorrhagic and included a 15 × 15 × 15-cm pseudocyst, which contained a metallic stent from a cystogastrostomy. This case describes a unique co-occurrence of numerous common complications of chronic pancreatitis. There are multiple ways by which pancreatitis can cause upper and lower GI bleeds. In this case, the presence of a cystogastrostomy stent allowed for a ruptured pseudoaneurysm to hemorrhage through the pancreatic pseudocyst and into the stomach and duodenum, mimicking the presentation of a more common upper GI bleed. The pseudocyst then ruptured causing abdominal hemorrhage. The passage of hemorrhage through a cystogastrostomy stent is not described in other literature.


Assuntos
Falso Aneurisma , Pseudocisto Pancreático , Falso Aneurisma/etiologia , Feminino , Hemorragia Gastrointestinal/etiologia , Humanos , Pessoa de Meia-Idade , Pâncreas , Artéria Esplênica
11.
J Vasc Interv Radiol ; 32(8): 1241.e1-1241.e12, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34332724

RESUMO

PURPOSE: To state the Society of Interventional Radiology's position on the use of image-guided thermal ablation for the treatment of early stage non-small cell lung cancer, recurrent lung cancer, and metastatic disease to the lung. MATERIALS AND METHODS: A multidisciplinary writing group, with expertise in treating lung cancer, conducted a comprehensive literature search to identify studies on the topic of interest. Recommendations were drafted and graded according to the updated SIR evidence grading system. A modified Delphi technique was used to achieve consensus agreement on the recommendation statements. RESULTS: A total of 63 studies, including existing systematic reviews and meta-analysis, retrospective cohort studies, and single-arm trials were identified. The expert writing group developed and agreed on 7 recommendations on the use of image-guided thermal ablation in the lung. CONCLUSION: SIR considers image-guided thermal ablation to be an acceptable treatment option for patients with inoperable Stage I NSCLC, those with recurrent NSCLC, as well as patients with metastatic lung disease.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Ablação por Cateter , Neoplasias Pulmonares , Canadá , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Humanos , Pulmão , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Recidiva Local de Neoplasia , Radiologia Intervencionista , Estudos Retrospectivos
12.
Cancer Imaging ; 21(1): 43, 2021 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-34162439

RESUMO

BACKGROUND: Performing Response Evaluation Criteria in Solid Tumor (RECISTS) measurement is a non-trivial task requiring much expertise and time. A deep learning-based algorithm has the potential to assist with rapid and consistent lesion measurement. PURPOSE: The aim of this study is to develop and evaluate deep learning (DL) algorithm for semi-automated unidirectional CT measurement of lung lesions. METHODS: This retrospective study included 1617 lung CT images from 8 publicly open datasets. A convolutional neural network was trained using 1373 training and validation images annotated by two radiologists. Performance of the DL algorithm was evaluated 244 test images annotated by one radiologist. DL algorithm's measurement consistency with human radiologist was evaluated using Intraclass Correlation Coefficient (ICC) and Bland-Altman plotting. Bonferroni's method was used to analyze difference in their diagnostic behavior, attributed by tumor characteristics. Statistical significance was set at p < 0.05. RESULTS: The DL algorithm yielded ICC score of 0.959 with human radiologist. Bland-Altman plotting suggested 240 (98.4 %) measurements realized within the upper and lower limits of agreement (LOA). Some measurements outside the LOA revealed difference in clinical reasoning between DL algorithm and human radiologist. Overall, the algorithm marginally overestimated the size of lesion by 2.97 % compared to human radiologists. Further investigation indicated tumor characteristics may be associated with the DL algorithm's diagnostic behavior of over or underestimating the lesion size compared to human radiologist. CONCLUSIONS: The DL algorithm for unidirectional measurement of lung tumor size demonstrated excellent agreement with human radiologist.


Assuntos
Aprendizado Profundo/normas , Neoplasias Pulmonares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Estudos Retrospectivos
13.
J Vasc Interv Radiol ; 32(8): 1242.e1-1242.e10, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34000388

RESUMO

PURPOSE: To provide guidance on quality improvement thresholds for outcomes and complications of image-guided thermal ablation for the treatment of early stage non-small cell lung cancer, recurrent lung cancer, and metastatic disease. MATERIALS AND METHODS: A multidisciplinary writing group conducted a comprehensive literature search to identify studies on the topic of interest. Data were extracted from relevant studies and thresholds were derived from a calculation of 2 standard deviations from the weighted mean of each outcome. A modified Delphi technique was used to achieve consensus agreement on the thresholds. RESULTS: Data from 29 studies, including systematic reviews and meta-analyses, retrospective cohort studies, and single-arm trials were extracted for calculation of the thresholds. The expert writing group agreed on thresholds for local control, overall survival and adverse events associated with image-guided thermal ablation. CONCLUSION: SIR recommends utilizing the indicator thresholds to review and assess the efficacy of ongoing quality improvement programs. When performance falls above or below specific thresholds, consideration of a review of policies and procedures to assess for potential causes, and to implement changes in practices, may be warranted.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Ablação por Cateter , Neoplasias Pulmonares , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Humanos , Pulmão , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Recidiva Local de Neoplasia , Melhoria de Qualidade , Radiologia Intervencionista , Estudos Retrospectivos
15.
Curr Probl Diagn Radiol ; 50(3): 321-327, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32014355

RESUMO

While a growing number of research studies have reported the inter-observer variability in computed tomographic (CT) measurements, there are very few interventional studies performed. We aimed to assess whether a peer benchmarking intervention tool may have an influence on reducing interobserver variability in CT measurements and identify possible barriers to the intervention. In this retrospective study, 13 board-certified radiologists repeatedly reviewed 10 CT image sets of lung lesions and hepatic metastases during 3 noncontiguous time periods (T1, T2, T3). Each preselected case contained normal anatomy cephalad and caudal to the lesion of interest. Lesion size measurement under RECISTS 1.1 guidelines, choice of CT slice, and time spent on measurement were captured. Prior to their final measurements, the participants were exposed to the intervention designed to reduce the number of measurements deviating from the median. Chi-square test was performed to identify radiologist-dependent factors associated with the variability. The percent of deviating measurements during T1 and T2 were 20.0% and 23.1%, respectively. There was no statistically significant change in the number of deviating measurements upon the presentation of the intervention despite the decrease in percent from 23.1% to 17.7%. The identified barriers to the intervention include clinical disagreements among radiologists. Specifically, the inter-observer variability was associated with the controversy over the choice of CT image slice (P = 0.045) and selection of start-point, axis, and end-point (P = 0.011). Clinical disagreements rather than random errors were barriers to reducing interobserver variability in CT measurement among experienced radiologists. Future interventions could aim to resolve the disagreement in an interactive approach.


Assuntos
Neoplasias Hepáticas , Tomografia Computadorizada por Raios X , Humanos , Variações Dependentes do Observador , Radiologistas , Reprodutibilidade dos Testes , Estudos Retrospectivos
16.
Clin Imaging ; 71: 121-125, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33197725

RESUMO

BACKGROUND: Accessory liver lobes and other congenital liver abnormalities are rare and most often asymptomatic. However, these abnormalities can result in liver torsion, requiring surgical resection. CASE REPORT: We report a case of a 72-year-old woman with hepatic lobe torsion. She presented with an acute onset of chest pain and was discovered to have hypoperfusion of the left lobe of the liver on contrast-enhanced abdominal computed tomography (CT) scan. An exploratory laparotomy revealed left hepatic lobe torsion with irreversible ischemic changes requiring left hepatic lobe resection. CONCLUSION: Even though hepatic torsion is rare, it should be considered in the differential diagnosis for abdominal pain and appropriately imaged so that surgical teams can prepare for the complex surgical procedure.


Assuntos
Hepatopatias , Doenças Raras , Dor Abdominal/etiologia , Idoso , Feminino , Humanos , Hepatopatias/diagnóstico por imagem , Hepatopatias/cirurgia , Doenças Raras/diagnóstico por imagem , Anormalidade Torcional/diagnóstico por imagem , Anormalidade Torcional/cirurgia
17.
BMJ Open ; 10(11): e040096, 2020 11 14.
Artigo em Inglês | MEDLINE | ID: mdl-33191265

RESUMO

BACKGROUND: A growing number of research studies have reported inter-observer variability in sizes of tumours measured from CT scans. It remains unclear whether the conventional statistical measures correctly evaluate the CT measurement consistency for optimal treatment management and decision-making. We compared and evaluated the existing measures for evaluating inter-observer variability in CT measurement of cancer lesions. METHODS: 13 board-certified radiologists repeatedly reviewed 10 CT image sets of lung lesions and hepatic metastases selected through a randomisation process. A total of 130 measurements under RECIST 1.1 (Response Evaluation Criteria in Solid Tumors) guidelines were collected for the demonstration. Intraclass correlation coefficient (ICC), Bland-Altman plotting and outlier counting methods were selected for the comparison. The each selected measure was used to evaluate three cases with observed, increased and decreased inter-observer variability. RESULTS: The ICC score yielded a weak detection when evaluating different levels of the inter-observer variability among radiologists (increased: 0.912; observed: 0.962; decreased: 0.990). The outlier counting method using Bland-Altman plotting with 2SD yielded no detection at all with its number of outliers unchanging regardless of level of inter-observer variability. Outlier counting based on domain knowledge was more sensitised to different levels of the inter-observer variability compared with the conventional measures (increased: 0.756; observed: 0.923; improved: 1.000). Visualisation of pairwise Bland-Altman bias was also sensitised to the inter-observer variability with its pattern rapidly changing in response to different levels of the inter-observer variability. CONCLUSIONS: Conventional measures may yield weak or no detection when evaluating different levels of the inter-observer variability among radiologists. We observed that the outlier counting based on domain knowledge was sensitised to the inter-observer variability in CT measurement of cancer lesions. Our study demonstrated that, under certain circumstances, the use of standard statistical correlation coefficients may be misleading and result in a sense of false security related to the consistency of measurement for optimal treatment management and decision-making.


Assuntos
Neoplasias Hepáticas , Tomografia Computadorizada por Raios X , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos
20.
AJR Am J Roentgenol ; 213(5): 1152-1156, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31216197

RESUMO

OBJECTIVE. The purpose of this study was to evaluate the safety and technical feasibility of inferior vena cava filter (IVCF) removal when filter elements penetrate adjacent bowel. MATERIALS AND METHODS. A multicenter retrospective review of IVCF retrievals between 2008 and 2018 was performed. Adult patients with either CT or endoscopic evidence of filter elements penetrating bowel before retrieval were included. Technical success of IVCF retrieval was recorded. Patient records were assessed for immediate, 30-day, and 90-day complications after retrieval. RESULTS. Thirty-nine consecutive adult patients (11 men and 28 women; mean age, 51.2 years; age range, 18-81 years) qualified for inclusion. Filter dwell time was a median of 148 days (range, 32-5395 days). No IVCFs were known to have migrated or caused iliocaval thrombosis. Five IVCFs (12.8%) had more than 15° tilt relative to the inferior vena cava (IVC) before retrieval. Three IVCFs (7.7%) had fractured elements identified at the time of retrieval. Mean international normalized ratio (INR) was 1.24 ± 0.53 (SD), and mean platelet count was 262 ± 139 × 103/µL. Ten patients (25.6%) were on antibiotics at the time of retrieval. All 39 IVCFs were successfully retrieved (technical success = 100%). Two patients experienced minor complications in the immediate postprocedural period, which resulted in a minor complication rate of 5.1%. There were no complications (major or minor) identified in any patient at 30 or 90 days after retrieval. The overall major complication rate was 0%. CONCLUSION. Endovascular retrieval of IVCFs with CT evidence of filter elements that have penetrated adjacent bowel is both safe and technically feasible.


Assuntos
Remoção de Dispositivo/métodos , Perfuração Intestinal/diagnóstico por imagem , Perfuração Intestinal/etiologia , Filtros de Veia Cava/efeitos adversos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Endoscopia Gastrointestinal , Estudos de Viabilidade , Feminino , Humanos , Coeficiente Internacional Normatizado , Masculino , Pessoa de Meia-Idade , Contagem de Plaquetas , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA