Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Disaster Mil Med ; 3: 1, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28265453

RESUMO

BACKGROUND: Hemorrhagic shock is the leading cause of trauma-related death in the military setting. Definitive surgical treatment of a combat casualty can be delayed and life-saving fluid resuscitation might be necessary in the field. Therefore, improved resuscitation strategies are critically needed for prolonged field and en route care. We developed an automated closed-loop control system capable of titrating fluid infusion to a target endpoint. We used the system to compare the performance of a decision table algorithm (DT) and a fuzzy logic controller (FL) to rescue and maintain the mean arterial pressure (MAP) at a target level during hemorrhages. Fuzzy logic empowered the control algorithm to emulate human expertise. We hypothesized that the FL controller would be more effective and more efficient than the DT algorithm by responding in a more rigid, structured way. METHODS: Ten conscious sheep were submitted to a hemorrhagic protocol of 25 ml/kg over three separate bleeds. Automated resuscitation with lactated Ringer's was initiated 30 min after the first hemorrhage started. The endpoint target was MAP. Group differences were assessed by two-tailed t test and alpha of 0.05. RESULTS: Both groups maintained MAP at similar levels throughout the study. However, the DT group required significantly more fluid than the FL group, 1745 ± 552 ml (42 ± 11 ml/kg) versus 978 ± 397 ml (26 ± 11 ml/kg), respectively (p = 0.03). CONCLUSION: The FL controller was more efficient than the DT algorithm and may provide a means to reduce fluid loading. Effectiveness was not different between the two strategies. Automated closed-loop resuscitation can restore and maintain blood pressure in a multi-hemorrhage model of shock.

2.
Prehosp Emerg Care ; 20(4): 485-92, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27158860

RESUMO

OBJECTIVE: Exposure to nerve agents requires prompt treatment. We hypothesized that intraosseous (IO) injections of drug antidotes into the vascularized bone marrow will provide a more rapid and effective means to treat exposure to nerve agents than standard intramuscular (IM) injections. We compared the pharmacokinetics of IM and IO administration of pralidoxime chloride (2-PAM Cl) during normovolemia and hypovolemia, as well as their combined administration during normovolemia in swine. METHODS: Ten normovolemic swine were randomly administered 2 mL, 660 mg 2-PAM Cl via the IM or IO route and monitored for 180 minutes. IM versus IO also was compared in 8 hypovolemic swine bled to a mean arterial pressure of 50 mmHg. In a combined group, an IO injection was administered followed by an IM injection 60 minutes later. Blood samples were collected at times over a 180-minute period to calculate standard pharmacokinetic variables to compare the 2 routes of administration. RESULTS: In the normovolemic swine, IM injection achieved therapeutic levels (4 µg/mL) in 2 minutes, whereas IO infusion achieved these levels in less than 15 seconds. 2-PAM-Cl concentrations fell below these levels at 60 minutes post-injection in both groups. In the hypovolemic swine, IM injection achieved therapeutic levels in 4 minutes compared to less than 15 seconds in the IO group. 2-PAM-Cl concentrations fell below therapeutic levels at 12 and 90 minutes post-injection in the IM and IO groups, respectively. In the combined IO-IM treatment, plasma levels remained above therapeutic levels for the entire experiment and had two concentration peaks that corresponded to IO and IM injections. CONCLUSIONS: The IO route for the delivery of 2-PAM Cl provides a significant time and high initial blood concentrations advantage compared to the IM route for the prehospital treatment of nerve agent exposure even under hypovolemic conditions. The initial concentration peak associated with IO, but not IM, may provide greater initial therapy at the most critical time.


Assuntos
Antídotos/administração & dosagem , Infusões Intraósseas , Injeções Intramusculares , Compostos de Pralidoxima/administração & dosagem , Animais , Vias de Administração de Medicamentos , Agentes Neurotóxicos , Distribuição Aleatória , Suínos
3.
Shock ; 38(6): 671-6, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23160521

RESUMO

More than 20,000 burn injury victims suffer from smoke inhalation injury in the United States annually. In an ovine model of acute lung injury, γ-tocopherol had a beneficial effect when nebulized into the airway. We hypothesize that γ-tocopherol scavenges reactive oxygen species (ROS) and reactive nitrogen species resulting from burn and smoke inhalation injury and that these ROS/reactive nitrogen species activate the arginase pathway, leading to increased collagen deposition and decreased pulmonary function. To test this hypothesis, ewes were operatively prepared for chronic study, then they were randomly divided into groups (n = 8): uninjured, injured, or injured with nebulization (γ-tocopherol [950 mg/g] and α-tocopherol [40 mg/g] from hours 3 to 48 after the injury). The injury, under deep anesthesia, consisted of a 20% total body surface burn and 36 breaths of cotton smoke; all animals were killed after 3 weeks. Treatment increased lung γ-tocopherol at 3 weeks after γ-tocopherol nebulization compared with injured sheep (1.75 ± 0.62 nmol/g vs. 0.45 ± 0.06, P < 0.05). The expression of dimethylarginine dimethylaminohydrolase-2, which degrades asymmetrical dimethylarginine, a nitric oxide synthase inhibitor, significantly increases with γ-tocopherol treatment compared with injured sheep (P < 0.05). Arginase activity (0.15 ± 0.02 µM urea/µg protein vs. 0.24 ± 0.009, P < 0.05), ornithine aminotransferase (11,720 ± 888 vs. 13,170 ± 1,775), and collagen deposition (0.62 ± 0.12 µM hydroxyproline/µg protein vs. 1.02 ± 0.13, P < 0.05) significantly decrease with γ-tocopherol compared with injured animals without γ-tocopherol. The decreases in arginase and collagen with γ-tocopherol are associated with significantly increased diffusion capacity (P < 0.05) and decreased lung wet-to-dry ratio (P < 0.05). Smoke-induced chronic pulmonary dysfunction is mediated through the ROS/asymmetrical dimethylarginine/arginase pathway, and ROS scavengers such as γ-tocopherol may be a potential therapeutic management of burn patients with inhalation injury.


Assuntos
Antioxidantes/farmacologia , Arginase/metabolismo , Queimaduras/metabolismo , Colágeno/metabolismo , Estresse Oxidativo/efeitos dos fármacos , Lesão por Inalação de Fumaça/metabolismo , gama-Tocoferol/farmacologia , Lesão Pulmonar Aguda/complicações , Lesão Pulmonar Aguda/tratamento farmacológico , Lesão Pulmonar Aguda/metabolismo , Animais , Queimaduras/complicações , Queimaduras/tratamento farmacológico , Feminino , Espécies Reativas de Oxigênio/metabolismo , Ovinos , Lesão por Inalação de Fumaça/complicações , Lesão por Inalação de Fumaça/tratamento farmacológico
4.
Burns ; 38(6): 908-16, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22459154

RESUMO

UNLABELLED: Smoke inhalation injury frequently increases the risk of pneumonia and mortality in burn patients. The pathophysiology of acute lung injury secondary to burn and smoke inhalation is well studied, but long-term pulmonary function, especially the process of lung tissue healing following burn and smoke inhalation, has not been fully investigated. By contrast, early burn excision has become the standard of care in the management of major burn injury. While many clinical studies and small-animal experiments support the concept of early burn wound excision, and show improved survival and infectious outcomes, we have developed a new chronic ovine model of burn and smoke inhalation injury with early excision and skin grafting that can be used to investigate lung pathophysiology over a period of 3 weeks. MATERIALS AND METHODS: Eighteen female sheep were surgically prepared for this study under isoflurane anesthesia. The animals were divided into three groups: an Early Excision group (20% TBSA, third-degree cutaneous burn and 36 breaths of cotton smoke followed by early excision and skin autografting at 24h after injury, n=6), a Control group (20% TBSA, third-degree cutaneous burn and 36 breaths of cotton smoke without early excision, n=6) and a Sham group (no injury, no early excision, n=6). After induced injury, all sheep were placed on a ventilator and fluid-resuscitated with Lactated Ringers solution (4 mL/% TBS/kg). At 24h post-injury, early excision was carried out to fascia, and skin grafting with meshed autografts (20/1000 in., 1:4 ratio) was performed under isoflurane anesthesia. At 48 h post-injury, weaning from ventilator was begun if PaO(2)/FiO(2) was above 250 and sheep were monitored for 3 weeks. RESULTS: At 96 h post-injury, all animals were weaned from ventilator. There are no significant differences in PaO(2)/FiO(2) between Early Excision and Control groups at any points. All animals were survived for 3 weeks without infectious complication in Early Excision and Sham groups, whereas two out of six animals in the Control group had abscess in lung. The percentage of the wound healed surviving area (mean ± SD) was 74.7 ± 7.8% on 17 days post-surgery in the Early Excision group. Lung wet-to-dry weight ratio (mean ± SD) was significantly increased in the Early Excision group vs. Sham group (p<0.05). The calculated net fluid balance significantly increased in the early excision compared to those seen in the Sham and Control groups. Plasma protein, oncotic pressure, hematocrit of % baseline, hemoglobin of % baseline, white blood cell and neutrophil were significantly decreased in the Early Excision group vs. Control group. CONCLUSIONS: The early excision model closely resembles practice in a clinical setting and allows long-term observations of pulmonary function following burn and smoke inhalation injury. Further studies are warranted to assess lung tissue scarring and measuring collagen deposition, lung compliance and diffusion capacity.


Assuntos
Queimaduras/cirurgia , Modelos Animais de Doenças , Transplante de Pele/métodos , Lesão por Inalação de Fumaça/fisiopatologia , Análise de Variância , Animais , Doença Crônica , Feminino , Hematócrito , Troca Gasosa Pulmonar/fisiologia , Ovinos , Fatores de Tempo , Resistência Vascular/fisiologia
5.
Toxicol Mech Methods ; 20(4): 197-203, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20201741

RESUMO

The recently developed murine model of smoke inhalation and burn (SB) injury was used to study the effect of the substance-P antagonist CP96345. C57BL/6 mice were pre-treated with an i.v. dose of a specific NK-1 receptor antagonist, CP9635, or its inactive enantiomer, CP96344, (10 mg/Kg) 1 h prior to SB injury per protocol (n = 5). Mice were anesthetized and exposed to cooled cotton smoke, 2X 30 s, followed by a 40% total body surface area flame burn per protocol. At 48 h after SB injury Evans Blue (EB) dye and myeloperoxidase (MPO) were measured in lung after vascular perfusion. Lungs were also analyzed for hemoglobin (Hb) and wet/dry weight ratio. In the current study, CP96345 pre-treatment caused a significant decrease in wet/dry weight ratio (23%, p = 0.048), EB (31%, p = 0.047), Hb (46%, p = 0.002), and MPO (54%, p = 0.037) levels following SB injury compared to animals with SB injury alone. CP-96344 pre-treatment caused an insignificant decrease in wet/dry weight ratio (14%, p = 0.18), EB (16%, p = 0.134), Hb (9%, p = 0.39), and an insignificant increase in MPO (4%, p = 0.79) as compared to mice that received SB injury alone. As expected, levels of EB, Hb, MPO, and wet/dry weight ratios were all significantly (p < 0.05) increased 48 h following SB injury alone compared to respective sham animals. In conclusion, the current study indicates that pre-treatment with a specific NK-1R antagonist CP-96345 attenuates the lung injury and inflammation induced by SB injury in mice.


Assuntos
Anti-Inflamatórios não Esteroides/farmacologia , Compostos de Bifenilo/farmacologia , Fumaça/efeitos adversos , Substância P/antagonistas & inibidores , Animais , Modelos Animais de Doenças , Camundongos , Estereoisomerismo
6.
Toxicol Mech Methods ; 19(3): 191-6, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19727335

RESUMO

The effects of neutral endopeptidase (NEP) in acute inflammation in the lung were studied using a newly developed murine model of smoke and burn (SB) injury. C57BL/6 mice were pretreated with an i.v. dose of a specific NEP antagonist CGS-24592 (10 mg/Kg) 1 h prior to SB injury (n = 5-8/group). Mice were anesthetized with i.p. ketamine/xylazine, intubated, and exposed to cooled cotton smoke (2 x 30 s). After s.c. injection of 1 ml 0.9% saline, each received a 40% total body surface area (TBSA) flame burn. Buprenorphene (2 mg/kg) was given i.p. and resuscitated by saline. Evans Blue dye (EB) was injected i.v. 15 min before sacrifice. Lung wet/dry weight ratio was measured. After vascular perfusion, lungs were analyzed for their levels of EB dye and myeloperoxidase (MPO). In mice pretreated with CGS-24592 followed by SB injury the EB levels were significantly higher (61%, p = 0.043) than those with SB injury alone. There was a significant increase (144%, p = 0.035) in EB dye in animals with SB injury alone as compared to shams. In mice pretreated with CGS-24592 prior to SB injury wet/dry weight ratios were significantly (27%, p = 0.042) higher compared to animals with SB injury alone. CGS-24592 pretreatment also caused a significant increase in MPO (29%, p = 0.026) as compared to mice with SB injury alone. In conclusion the current study indicates that specific NEP inhibitor CGS 24592 exacerbates the SB-induced lung injury and inflammation in mice.


Assuntos
Queimaduras/fisiopatologia , Neprilisina/metabolismo , Edema Pulmonar/fisiopatologia , Lesão por Inalação de Fumaça/fisiopatologia , Animais , Queimaduras/enzimologia , Modelos Animais de Doenças , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Neprilisina/antagonistas & inibidores , Organofosfonatos/farmacologia , Fenilalanina/análogos & derivados , Fenilalanina/farmacologia , Inibidores de Proteases/farmacologia , Edema Pulmonar/enzimologia , Lesão por Inalação de Fumaça/enzimologia
7.
J Appl Physiol (1985) ; 105(2): 678-84, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18436699

RESUMO

The morbidity and mortality of burn victims increase when burn injury is combined with smoke inhalation. The goal of the present study was to develop a murine model of burn and smoke inhalation injury to more precisely reveal the mechanistic aspects of these pathological changes. The burn injury mouse group received a 40% total body surface area third-degree burn alone, the smoke inhalation injury mouse group received two 30-s exposures of cotton smoke alone, and the combined burn and smoke inhalation injury mouse group received both the burn and the smoke inhalation injury. Animal survival was monitored for 120 h. Survival rates in the burn injury group, the smoke inhalation injury group, and the combined injury group were 70%, 60%, and 30%, respectively. Mice that received combined burn and smoke injury developed greater lung damage as evidenced by histological changes (septal thickening and interstitial edema) and higher lung water content. These mice also displayed more severely impaired pulmonary gas exchange [arterial PO2 (PaO2)/inspired O2 fraction (FiO2)<200]. Lung myeloperoxidase activity was significantly higher in burn and smoke-injured animals compared with the other three experimental groups. Plasma NO2-/NO3-, lung inducible nitric oxide synthase (iNOS) activity, and iNOS mRNA increased with injury; however, the burn and smoke injury group exhibited a higher response. Severity of burn and smoke inhalation injury was associated with more pronounced production of nitric oxide and accumulation of activated leukocytes in lung tissue. The murine model of burn and smoke inhalation injury allows us to better understand pathophysiological mechanisms underlying cardiopulmonary morbidity secondary to burn and smoke inhalation injury.


Assuntos
Queimaduras/fisiopatologia , Pulmão/fisiopatologia , Lesão por Inalação de Fumaça/fisiopatologia , Animais , Queimaduras/patologia , Feminino , Gliceraldeído-3-Fosfato Desidrogenases/metabolismo , Pulmão/patologia , Camundongos , Camundongos Endogâmicos C57BL , Óxido Nítrico/sangue , Óxido Nítrico Sintase Tipo II/biossíntese , Óxido Nítrico Sintase Tipo II/genética , Óxido Nítrico Sintase Tipo II/metabolismo , Tamanho do Órgão , Peroxidase/metabolismo , Troca Gasosa Pulmonar , RNA Mensageiro/biossíntese , RNA Mensageiro/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Lesão por Inalação de Fumaça/patologia
8.
Toxicol Mech Methods ; 18(7): 551-9, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20020853

RESUMO

ABSTRACT To test concepts developed in our ovine model of acute respiratory distress syndrome, specifically the roles of neuropeptides and other peptide mediators, a recently developed murine model of combined smoke inhalation and burn (SB) injury was extended by applying methods for quantitative assessment of acute inflammation in the lung. Mice received SB injury per protocol, n = 5 to 7 per group. Mice were anesthetized with i.p. ketamine/xylazine, endotracheally intubated, and exposed to cooled cotton smoke (4 x 30 sec for Balb/C, 2 x 30 sec for C57BL/6). After s.c. injection of 1 mL 0.9% saline, each received a 40% total body surface area (TBSA) flame burn. Buprenorphine (0.1 mg/kg) was given i.p. for postoperative analgesia; 0.9% saline was given i.p. at 4 mL/kg per %TBSA burn. Evans Blue dye (EB) was injected i.v. 15 min before sacrifice. Lung wet/dry weight ratio was measured. In other animals, after vascular perfusion with buffered saline, lungs were sampled and analyzed for myeloperoxidase (MPO), using an EIA kit, and for their content of EB dye. There was a significant (p < 0.05) increase in EB dye content, wet/dry weight ratio, and MPO 24 h after injury in Balb/C mice. Similar increases were seen in C57BL/6 mice 48 h after SB injury, but not at 24 h. C57 mice tolerated less smoke inhalation than Balb/C mice, due to postexposure apnea, and required 48 h to show significant increases in these variables. Direct comparison between animals injured by 40% TBSA burn and 2 x 30 sec smoke exposure and sacrificed after 48 h showed significantly greater abnormality in the C57BL/6 mice. The mouse model can be used effectively to assess acute inflammation in the lung.

9.
Perfusion ; 22(2): 81-6, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17708156

RESUMO

INTRODUCTION: Our group has developed a paracorporeal artificial lung (PAL) attached in a pulmonary artery (PA) to PA in series configuration to address profound respiratory failure and serve as a bridge to transplant and/or recovery. We recently designed, developed and converted our passive pre-PAL compliance chamber to an active, synchronized, counterpulsating assist device to relieve right heart strain and offset increased work placed on the right ventricle when the PAL is attached. In this study, we evaluated the safety and performance of both a valved and non-valved optional active compliance chamber (OACC) in a PA-PA PAL for right heart assistance in normal adult sheep. METHODS: Eleven sheep (30-50 kg) were divided into non-valved OACC (n = 6) and valved (n = 5) OACC groups. To mimic pulmonary hypertension, a C-clamp was placed distal to the OACC-PAL and occluded until a 20% decrease in cardiac output (CO) was achieved. The OACC was activated, and right ventricular pressure (RVP), pulmonary artery pressure (PAP), mean arterial pressure (MAP) and CO were recorded. RESULTS: All eleven animals tolerated the implantation of the OACC PAL. Activation of the OACC resulted in a significant increase in CO. Systolic and diastolic right ventricular pressure decreased in both groups. Lastly, counterpulsation increased the mean PAP in all animals and peak PAP reached 89 mmHg. Despite providing right heart assistance, synchronizing the counterpulsation was technically difficult, and the high peak PA pressures resulted in anastomotic bleeding in all animals and anastomotic breakdown in 4/11 animals. CONCLUSIONS: An OACC PAL perfused by the right ventricle applied in series with the pulmonary circulation reduces ventricular load and improves cardiac efficiency. These preliminary data suggest the potential of an artificial lung in unloading the strained right ventricle and acting as a bridge to transplantation. The augmented peak PA pressures, resulting in bleeding and anastomotic breakdown, and complexity in synchronizing the cardiac cycle with the pulsations of the augmented OACC, compromise this configuration.


Assuntos
Órgãos Artificiais , Coração Auxiliar , Complacência Pulmonar , Pulmão , Disfunção Ventricular Direita/terapia , Animais , Desenho de Prótese , Artéria Pulmonar , Circulação Pulmonar , Pressão Propulsora Pulmonar , Ovinos
10.
J Burn Care Res ; 27(4): 463-71, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16819349

RESUMO

We undertook an assessment of high-frequency percussive ventilation (HFPV) and systemic heparin on survival in our LD100 sheep model of smoke/burn-induced acute respiratory distress syndrome (ARDS). This was a prospective controlled outcomes study in a large animal critical care laboratory. ARDS was induced in 13 sheep by a combination of 48 cotton smoke breaths and 40% full-thickness cutaneous burn (LD100) followed by mechanical ventilation (15 ml/kg tidal volume). After meeting ARDS criteria (PaO2/FiO2 < 200), the sheep were divided into high-frequency percussive ventilation (HFPV; n = 7) or volume-controlled mechanical ventilation (VCMV; n = 6) groups. Both groups received systemic heparin to achieve an ACT 180-300 seconds. HFPV was managed with the Volumetric Diffusive Respiration Ventilator (Percussionaire Corp., Sandpoint, ID). The VCMV group was managed with up to 10 ml/kg tidal volume. Arterial blood gases and ventilator settings were monitored every 6 hours after onset of ARDS. HFPV did not affect sheep hemodynamics. Survival 84 hours after smoke and burn injury was significantly greater in the HFPV (7/7, 100%) compared with the VCMV group (3/6, 50%, P < .05). PaCO2 was significantly greater in VCMV group at 36, 48, and 72 hours after smoke and burn injury. PaO2/FiO2 after 36 hours of smoke and burn injury in the HFPV group was improved compared with the VCMV group, but no statistical difference was found. In the VCMV group, peak airway pressure was decreased to 19.7 +/- 2.2 cm H2O at 36 hours from 29 +/- 2.8 at 24 hours as the tidal volume changed from 15 ml/kg to 10 ml/kg and then gradually increased to 39 +/- 5.6 cm H2O at 72 hours. In the HFPV group, peak inspiratory pressure kept constant at a level of 30 cmH2O. In our smoke/burn-induced LD100 sheep model of ARDS, volume-controlled mechanical ventilation with systemic heparin achieved a 50% survival whereas HFPV with systemic heparin achieved 100% survival at 60 hours after the onset of ARDS.


Assuntos
Anticoagulantes/uso terapêutico , Queimaduras/complicações , Heparina/uso terapêutico , Ventilação de Alta Frequência , Síndrome do Desconforto Respiratório/terapia , Lesão por Inalação de Fumaça/complicações , Animais , Terapia Combinada , Modelos Animais de Doenças , Síndrome do Desconforto Respiratório/etiologia , Ovinos , Resultado do Tratamento
11.
Crit Care Med ; 34(4): 1185-92, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16484921

RESUMO

OBJECTIVE: NaCl solutions (7.5%) have been reported to be effective for resuscitation in animals and trauma patients, but these solutions are not approved for use in the United States. We hypothesized that infusion of Food and Drug Administration-approved 3% NaCl provides superior cardiovascular and metabolic function while reducing the overall fluid requirement for resuscitation of hemorrhage. Our objective was to compare four groups, hypotensive and normotensive resuscitation of hemorrhage using 3% NaCl (HS) or lactated Ringer's (LR). DESIGN: Sheep were hemorrhaged in three separate bleeds, 25 mL/kg at T0 mins and 5 mL/kg at both T50 and T70 mins. SETTING: University laboratory. SUBJECTS: Instrumented conscious sheep. INTERVENTIONS: Resuscitation was started at T30 mins and continued until T180. Normotensive and hypotensive resuscitation to mean arterial pressures of 90 mm Hg and 65 mm Hg, respectively, was performed with LR or HS using a closed-loop resuscitation system. MEASUREMENTS AND MAIN RESULTS: All four groups were successfully resuscitated to near target levels. Two animals in the hypotensive treatment protocols died during the second and third bleeding, one with the LR65 group and one with the HS65 group. Mean infused volumes were 59.9 +/- 7.0 and 18.0 +/- 5.9 in the LR90 and LR65 groups, respectively, and were 19.6 +/- 2.2 mL/kg and 13.3 +/- 5.7 mL/kg in the HS90 and HS65 treatments (p < .05; LR90 vs. each of the groups). Cardiac indexes were significantly higher with normotensive vs. hypotensive treatment. However, there was no hemodynamic advantage apparent with HS vs. LR when compared with the normotensive or hypotensive treatments. Some animals had high lactate levels (>10 mmol) with both of the hypotensive treatments and also with the HS90 treatment, while not one of the 11 LR90 treatment animals had lactate levels >8 mmol. CONCLUSIONS: Volume sparing was apparent with HS, but no hemodynamic or metabolic advantage was apparent when used for either normotensive or hypotensive resuscitation. Trends toward lower base excess values and higher occurrences of deaths only in the hypotensive treatment protocols suggest that resuscitation to a target mean arterial pressure of 65 mm Hg may be too low.


Assuntos
Ressuscitação/métodos , Choque Hemorrágico/terapia , Cloreto de Sódio/administração & dosagem , Animais , Feminino , Ovinos
12.
Opt Lett ; 30(13): 1677-9, 2005 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-16075535

RESUMO

The optoacoustic technique is noninvasive, has high spatial resolution, and potentially can be used to measure the total hemoglobin concentration ([THb]) continuously and accurately. We performed in vitro measurements in blood and in vivo tests in healthy volunteers. Our clinical protocol included rapid infusion of intravenous saline to simulate rapid change in the [THb] during fluid therapy or surgery. Optoacoustic measurements were made from the wrist area overlying the radial artery for more than 1 h. The amplitude of the optoacoustic signal generated in the radial artery closely followed the [THb] measured directly in concurrently collected blood samples.


Assuntos
Acústica , Análise Química do Sangue/métodos , Hemoglobinas/análise , Lasers , Animais , Humanos , Óptica e Fotônica , Projetos Piloto , Ovinos
13.
Anesthesiology ; 102(1): 69-75, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15618789

RESUMO

BACKGROUND: Current, invasive cerebral oxygenation monitors require either retrograde jugular venous bulb cannulation or intraparenchymal probe insertion. There is no accurate, noninvasive, continuous monitor of cerebral blood oxygenation. METHODS: The authors designed, built, and tested novel optoacoustic instrumentation that continuously measures blood oxygenation in the superior sagittal sinus (SSS) in vivo in 12 anesthetized sheep. In this technique, laser pulses generate acoustic signals, the amplitudes and slopes of which are proportional to oxyhemoglobin saturation in the SSS. Optoacoustic signals from the SSS measured through the scalp and cranium were compared with directly measured oxyhemoglobin saturation in blood withdrawn from the cannulated SSS. RESULTS: In the first experiments (feasibility), FIO2 changes produced rapid corresponding changes in optoacoustic signals and arterial oxygen saturation. In the second experiments (validation), the authors correlated oxyhemoglobin saturation in the SSS with optoacoustic signals and developed quantifying algorithms. In eight of nine validation experiments, the authors quantified optoacoustic signals by subtracting the temporal profile at low FIO2 (0.08-0.1) from profiles at higher FIO2 and integrating those signals in the range from 3 to 5 micros. In each validation experiment, optoacoustic signals showed tight temporal association and good linear correlation with measured oxyhemoglobin saturation (r2 0.75 to 0.99 for eight individual experiments). CONCLUSIONS: The optoacoustic system detects signals induced in the SSS and optoacoustic signals from the SSS linearly correlate with oxyhemoglobin saturation. The data suggest that the optoacoustic technique merits clinical evaluation.


Assuntos
Circulação Cerebrovascular/fisiologia , Monitorização Fisiológica/instrumentação , Oxigênio/sangue , Ovinos/fisiologia , Estimulação Acústica , Algoritmos , Animais , Cateterismo , Lasers , Oxiemoglobinas/metabolismo , Ultrassom
14.
Shock ; 22(3): 262-9, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15316397

RESUMO

Hypotensive resuscitation has been advocated as a better means to perform field resuscitation of penetrating trauma. Our hypothesis is that hypotensive resuscitation using either crystalloid or colloid provides equivalent or improved metabolic function while reducing the overall fluid requirement for resuscitation of hemorrhage. We compared hypotensive and normotensive resuscitation of hemorrhage using lactated Ringer's (LR) with hypotensive resuscitation using Hextend (Hex), 6% hetastarch in isotonic buffered saline. Instrumented conscious sheep were hemorrhaged in three separate bleeds, 25 mL/kg at T0 and 5 mL/kg at both T50 and T70. Resuscitation was started at T30 and continued until T180. Hypotensive resuscitation to a mean arterial pressure (MAP) of 65 mmHg was performed with LR or Hex using a closed-loop resuscitation (CLR) system for a LR-65 and Hex-65 treatment protocol. A control treatment protocol was resuscitation with LR to a MAP target of 90 mmHg, LR-90. All treatment protocols were successfully resuscitated to near target levels. Two animals in the hypotensive treatment protocols died during the second and third bleedings, one in the LR-65 and one in the Hex-65 treatment protocol. Mean infused volumes were 61.4 +/- 11.3, 18.0 +/- 5.9, and 11.6 +/- 1.9 mL/kg in the LR-90, LR-65, and Hex-65 treatments, respectively (*P < 0.05 versus LR-90). Mean minimum base excess (BE) values were +1.9 +/- 1.4, -5.8 +/- 4.3, and -5.9 +/- 4.0 mEq/L in the LR-90, LR-65, and Hex-65 treatments, respectively. Hypotensive resuscitation with LR greatly reduced volume requirements as compared with normotensive resuscitation, and Hex achieved additional volume sparing. However, trends toward lower BE values and the occurrence of deaths only in the hypotensive treatment protocols suggest that resuscitation to a target MAP of 65 mmHg may be too low for optimal outcomes.


Assuntos
Hipotensão/fisiopatologia , Soluções para Reidratação/uso terapêutico , Ressuscitação/métodos , Choque Hemorrágico/terapia , Animais , Pressão Sanguínea , Débito Cardíaco , Coloides , Soluções Cristaloides , Modelos Animais de Doenças , Feminino , Frequência Cardíaca , Hemoglobinas/metabolismo , Hipotensão/sangue , Soluções Isotônicas , Substitutos do Plasma , Ovinos , Choque Hemorrágico/sangue , Choque Hemorrágico/fisiopatologia
15.
Appl Opt ; 43(17): 3401-7, 2004 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-15219019

RESUMO

Measurement of total hemoglobin concentration [Hgb] is a blood test that is widely used to evaluate outpatients, hospital inpatients, and surgical patients, especially those undergoing surgery associated with extensive blood loss, rapid fluid administration, and transfusion of packed red blood cells. Current techniques for measurement of [Hgb] are invasive (requiring blood sampling) and cannot provide real-time, continuous monitoring. We propose to use an optoacoustic technique for noninvasive and continuous monitoring of [Hgb]. The high resolution of the optoacoustic technique may provide accurate measurement of [Hgb] by detection and analysis of optoacoustic signals induced by short optical pulses in blood circulating in arteries or veins. We designed, built, and tested in vitro (in both tissue phantoms and in preliminary in vivo experiments) a portable optoacoustic system for the monitoring of [Hgb] in the radial artery. The system includes a nanosecond laser operating in the near-infrared spectral range and a sensitive optoacoustic probe designed to irradiate the radial artery through the skin and detect optoacoustic signals induced in blood. Results of our studies demonstrated that (1) the slope of optoacoustic waves induced in blood in the transmission mode is linearly dependent on [Hgb] in the range from 6.2 to 12.4 g/dl, (2) optoacoustic signals can be detected despite optical attenuation in turbid tissue phantoms with a thickness of 1 cm, and (3) the optoacoustic system detects signals induced in blood circulating in the radial artery. These data suggest that the optoacoustic system can be used for accurate, noninvasive, real-time, and continuous monitoring of [Hgb].


Assuntos
Acústica/instrumentação , Análise Química do Sangue/instrumentação , Análise Química do Sangue/métodos , Hemoglobinas/análise , Lasers , Artéria Radial/metabolismo , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ovinos , Ultrassonografia/instrumentação , Ultrassonografia/métodos
16.
Shock ; 21(1): 31-7, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14676681

RESUMO

Sepsis is among the leading causes of death in the critically ill, yet the pathophysiology of sepsis is incompletely understood. Genetically engineered mice offer a unique opportunity to explore the cellular and molecular pathogenesis of sepsis. However, the hemodynamic responses of mice during sepsis are not completely understood because of the difficulty in performing cardiovascular measurements in mice. We used a 1.4-F pressure and conductance catheter to measure hemodynamics in wild-type C57BL/6J mice during sepsis caused by cecal ligation and puncture. Septic mice exhibited significant hypothermia compared with the sham group. In addition, there was a progressive decrease in mean arterial blood pressure and systemic vascular resistance in septic mice as well as an increase in stroke volume and cardiac output. Sepsis also caused a significant time-dependent impairment of left ventricular function as indicated by decreased dp/dtmax and dp/dtmin. The slope of end systolic pressure volume relationship also decreased over time, as did the time varying maximum elastance and preload-recruitable stroke work of the left ventricle. In conclusion, septic mice exhibit hemodynamic alterations during sepsis that are similar to those observed in humans. The miniaturized conductance catheter allows for effective measurements of hemodynamic function in septic mice and provides measurements that cannot be obtained using other cardiovascular monitoring techniques.


Assuntos
Fenômenos Fisiológicos Cardiovasculares , Contração Miocárdica , Sepse/patologia , Animais , Pressão Sanguínea , Temperatura Corporal , Ceco/patologia , Modelos Animais de Doenças , Feminino , Temperatura Alta , Ligadura , Camundongos , Camundongos Endogâmicos C57BL , Miocárdio/patologia , Peritonite/patologia , Pressão , Punções , Fatores de Tempo , Função Ventricular Esquerda
17.
ASAIO J ; 49(6): 673-7, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14655733

RESUMO

A new perfluorocopolymer coating for micropore hollow fiber gas exchangers was developed to improve gas exchange, reduce plasma leakage, and reduce blood-surface interactions. The present authors evaluated gas exchanger performance using this new coating in a prospective, randomized, controlled, unblinded, large animal model of CO2 retention. Adult sheep (30-40 kg), under general anesthesia, underwent cannulation of the carotid artery (12 F) and jugular vein (14 F). The perfluorocopolymer coated (n = 5) and uncoated (n = 5) gas exchangers were attached to an arteriovenous CO2 removal (AVCO2R) circuit. Blood gases, CO2 removal, and hemodynamics were monitored throughout the 6 hour study. Average CO2 removal was 107.6 +/- 15.6 ml/min (coated) vs. 93.0 +/- 13.9 ml/min (uncoated; p < 0.01). PaCO2 and CO2 removal for both coated and uncoated did not deteriorate significantly over the study. Average AVCO2R blood flow was 1,130 +/- 25 ml/min (coated) versus 1,101 +/- 79 ml/min (uncoated; p = not significant). Likewise, cardiac output and AVCO2R blood flow did not change over the duration of the study. No significant differences in the pressure gradient or resistance between devices (coated, 6.89 +/- 1.14 mm Hg/L/min; uncoated, 6.42 +/- 0.23 mm Hg/L/min) was noted. The authors concluded that the new perfluorocopolymer coated gas exchanger improved CO2 removal without compromising hemodynamics in an acute performance evaluation.


Assuntos
Dióxido de Carbono/sangue , Materiais Revestidos Biocompatíveis/farmacologia , Oxigenação por Membrana Extracorpórea/métodos , Polímeros de Fluorcarboneto/farmacologia , Fluorocarbonos/farmacologia , Animais , Débito Cardíaco , Modelos Animais , Troca Gasosa Pulmonar , Distribuição Aleatória , Ovinos , Resistência Vascular
18.
ASAIO J ; 49(5): 564-7, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14524565

RESUMO

Extracorporeal arteriovenous carbon dioxide removal (AVCO2R) using percutaneous cannulae and a low resistance gas exchanger achieves near total CO2 removal, allowing lung rest and potentially improving survival. AVCO2R, redesigned to allow ambulation, has potential as treatment for severe chronic obstructive pulmonary disease or rehabilitation before lung transplant. The purposes of this study were to 1) determine the optimal ambulatory access for AVCO2 removal and 2) develop a prototype Ambulatory-AVCO2R gas exchanger. Initially, reinforced Gore-Tex 6 mm (two) and 8 mm (four) grafts were anastomosed to sheep carotid arteries and jugular veins as a loop in parallel to the cranial circulation to determine blood flow capabilities. Blood flow was 100-150 ml/min with a 14 gauge dialysis needle, and transected 6 mm Gore-Tex grafts achieved 500-900 ml blood flow, whereas transected 8 mm grafts achieved up to 2000 ml/min flow. The polytetrafluoroethylene (PTFE) loops were then connected to our newly developed ultra low resistance pumpless gas exchanger for ambulatory AVCO2R. The average pressure gradient across the prototype Ambulatory-AVCO2R gas exchangers (n = 5) was 2.8 +/- 0.8 mm Hg, and mean CO2 removal was 104.8 +/- 14.0 ml/min, with an average blood flow of 900 ml/min. We conclude that an 8 mm Gore-Tex reinforced graft arteriovenous loop supplies ample blood flow for our new ultra low resistance Ambulatory-AVCO2R to achieve near total CO2 removal.


Assuntos
Derivação Arteriovenosa Cirúrgica , Dióxido de Carbono/metabolismo , Oxigenação por Membrana Extracorpórea/instrumentação , Oxigenação por Membrana Extracorpórea/métodos , Animais , Atividade Motora , Projetos Piloto , Politetrafluoretileno , Ovinos
19.
Exp Brain Res ; 152(3): 329-34, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12904938

RESUMO

Lubeluzole [S-4-(2-benzothiazolylmethylamino)-alpha-((3,4-difluorophenoxy)methyl)-1-piperidineethanol] reduces the severity of cerebral injury in animal models of brain ischemia. Its beneficial effects may include decreased concentration of extracellular glutamate, blockade of sodium and calcium channels, and attenuation of nitric oxide-mediated neuronal death. Previous studies have shown that global cerebral ischemia in rabbits impaired the subsequent acquisition of a trace-conditioned eyeblink reflex. Here, we examined the effect of preischemic treatment with lubeluzole on the acquisition of a trace-conditioned eyeblink response after 6.5 min of global cerebral ischemia. Three groups of rabbits underwent cerebral ischemia: one group underwent ischemia alone (I) and two groups underwent ischemia and also received lubeluzole (L(1), 1.25 mg/kg, and L(2), 2.5 mg/kg). All animals were subsequently trained using classical trace conditioning. Each training session consisted of the presentation of the conditioned stimulus (an 85-dB, 6-kHz auditory tone lasting for 100 ms) followed by a trace interval (a period of 300 ms during which no external stimulus was delivered) followed finally by the delivery of the unconditioned stimulus (a 150-ms puff of air directed at the cornea). We found that animals receiving preischemic administration of 1.25 mg/kg of lubeluzole demonstrated a significantly improved acquisition of the trace-conditioned reflex as compared to animals that did not receive lubeluzole. This finding demonstrates improved long-term neurobehavioral outcome with preischemic administration of 1.25 mg/kg of lubeluzole.


Assuntos
Isquemia Encefálica/prevenção & controle , Condicionamento Psicológico/efeitos dos fármacos , Aprendizagem/efeitos dos fármacos , Piperidinas/farmacologia , Piperidinas/uso terapêutico , Tiazóis/farmacologia , Tiazóis/uso terapêutico , Animais , Isquemia Encefálica/fisiopatologia , Condicionamento Psicológico/fisiologia , Aprendizagem/fisiologia , Masculino , Coelhos
20.
J Invest Surg ; 16(3): 177-84, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12775434

RESUMO

An artificial lung may offer a bridge to recovery or transplant. Utilizing our recently developed paracorporeal artificial lung (PAL) in survival studies in sheep, we critically review our perioperative/anesthetic protocol. Adult Suffolk ewes (n = 15) underwent general anesthesia induced by ketamine (7-15 mg/kg, im) and isoflurane by mask, then intubated and maintained by 4.0-5.0% isoflurane titrated to mean arterial pressure (MAP) 70-110 mm Hg. After a latissimus-sparing thoracotomy and systemic heparinization (200 IU/kg), arterial grafts were anastomosed to the proximal and distal main pulmonary artery in an end-of-graft to side-of-artery fashion. A snare was passed around the pulmonary artery between anastomoses. When the snare was tightened, full pulmonary blood flow was diverted through the cannulae and immediately through the PAL. Perioperative crystalloids included a 500-mL prime, lactated Ringer's (LR) titrated to CVP 5-7 mm Hg, and a heparin infusion (activated clotting time [ACT] 250-300 s). Buprenorphine (0.3 mg im tid) controlled postoperative pain. Hemodynamic parameters, arterial blood gases (ABGs), and ACTs were measured every 6 h. Thirteen of 15 sheep survived the operation and were extubated in less than 20 min. Two groups were studied for up to 7-day survival. Both groups underwent immediate connection to the PAL diverting full pulmonary blood flow. Group 1 (n = 8) underwent immediate connection to a rigidly housed PAL, and 4 of 8 demonstrated immediate right heart failure. In Group 2 a compliance chamber was added to the PAL inflow, and 6 of 7 had stable hemodynamic function for the duration of the study. Incremental improvements in the PAL and our anesthetic and perioperative care have resulted in reliable survival in adult sheep allowing for artificial lung development.


Assuntos
Anestesia/métodos , Órgãos Artificiais , Pulmão , Algoritmos , Animais , Modelos Animais , Ovinos , Taxa de Sobrevida , Disfunção Ventricular Direita/mortalidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA