Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Materials (Basel) ; 17(10)2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38793304

RESUMO

The results of an experimental and mathematical study into the MmNi4.2Mn0.8 compound's hydrogen storage properties are presented in the present research. Plotting and discussion of the experimental isotherms (P-C-T) for different starting temperatures (288 K, 298 K, 308 K, and 318 K) were carried out first. Then, the enthalpy and entropy of formation (ΔH0, ΔS0) were deduced from the plot of van't Hoff. Following that, the P-C-T were contrasted with a mathematical model developed via statistical physics modeling. The steric and energetic parameters, such as the number of the receiving sites (n1, n2), their densities (Nm1, Nm2), and the energy parameters (P1, P2) of the system, were calculated thanks to the excellent agreement between the numerical and experimental results. Therefore, plotting and discussing these parameters in relation to temperature preceded their application in determining the amount of hydrogen in each type of site per unit of metal ([H/M]1, [H/M]2) as well as for the entire system [H/M] versus temperature and pressure besides the absorption energies associated with each kind of site (ΔE1, ΔE2) and the thermodynamic functions (free energy, Gibbs energy, and entropy) that control the absorption reaction.

2.
Heliyon ; 9(10): e20311, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37767487

RESUMO

A study of the magnetic properties of LaNi5 intermetallic compoundand and their effect on desorption reaction was carried out as a function of temperature. A Vibrating Sample Magnetometer (VSM) was used for the magnetic measurements and a Metal Hydrogen Reactor (MHR) supplied by a constant current through a coil was used for the hydrogen desorption reaction under the action of a magnetostatic field. Then, the hysteresis cycle, the first magnetization curve, the thermo-magnetization curves and the desorbed hydrogen mass were determined. The results showed that the application of a magnetic field corresponding to the magnetization at saturation Ms at a given temperature improved the hydrogen desorption reaction by the LaNi5.

3.
RSC Adv ; 13(26): 17750-17764, 2023 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-37323437

RESUMO

Recently, double perovskites have shown excellent potential considering the instability and toxicity problems of lead halide perovskites in optoelectronic devices. Here, the double perovskites Cs2MBiCl6 (M = Ag, Cu) were successfully synthesized via the slow evaporation solution growth technique. The cubic phase of these double perovskite materials was verified through the X-ray diffraction pattern. The investigation of Cs2CuBiCl6 and Cs2AgBiCl6 utilizing optical analysis showed that their respective indirect band-gap values were 1.31 and 2.92 eV, respectively. These materials, which are double perovskites, were examined using the impedance spectroscopy technique within the 10-1 to 106 Hz frequency and 300-400 K temperature ranges. Jonncher's power law was utilized to describe AC conductivity. The outcomes of the study on charge transportation in Cs2MBiCl6 (where M = Ag, Cu) suggest that the non-overlapping small polaron tunneling mechanism was present in Cs2CuBiCl6, whereas the overlapping large polaron tunneling mechanism was present in Cs2AgBiCl6.

4.
RSC Adv ; 11(35): 21767-21780, 2021 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-35478791

RESUMO

In the field of commercialization, lead-free metal halide perovskite materials are becoming more popular these days because of their prospective use in solar cells and also in other optoelectronic applications. In this paper, a non-toxic CsSnCl3 metal halide is successfully synthesized via the slow evaporation solution growth technique. Such systematic characterizations as differential scanning calorimetry (DSC) measurements, dielectric measurements, and variable-temperature structural analyses indicate that CsSnCl3 goes through a reversible phase transformation at T = 391/393 K from the monoclinic to the cubic system. Optical measurements of CsSnCl3 reveal a direct band-gap value of about 3.04 eV. The study of the charge transfer mechanism of CsSnCl3 is carried out based on Elliott's theory. The conduction mechanism in CsSnCl3 is interpreted through the following two approaches: the non-overlapping small polaron tunneling (NSPT) model (monoclinic phase) and the overlapping large polaron tunneling (OLPT) model (cubic phase). Moreover, the high dielectric constant of CsSnCl3 which is associated with a low dielectric loss makes it a possible candidate for energy harvesting devices.

5.
Diagn Microbiol Infect Dis ; 76(3): 306-8, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23632250

RESUMO

The objective of the study is to compare the performance of conventional fluorescence microscopy (CFM) and light-emitting diode (LED) fluorescence microscopy (FM) for detection of acid-fast bacilli (AFB) in clinical samples. We included AFB smears, stained using the auramine O method and blindly examined with both CFM and LED-FM. Culture results were used as reference for evaluating the reliability of the FM. We included 180 culture positive specimens and an equal number of culture negative specimens. Sensitivities for the CFM and LED-FM were 79.4% and 82.2%, respectively. Both microscopes had a high specificity (97.2%). The negative-positive (>1 cross) inter-reader agreement of LED-FM and CFM was excellent. Therefore, detection of scanty AFB was higher with LED-FM. Both microscopes were equivalent with respect to time required to read smears. Although it was not faster than CFM, the higher detection of scanty AFB smears combined with ease of use supports the consideration of LED microscopy by all tuberculosis diagnostic laboratories, as a replacement for conventional fluorescence microscopes.


Assuntos
Mycobacterium tuberculosis/crescimento & desenvolvimento , Tuberculose Pulmonar/diagnóstico , Estudos de Casos e Controles , Técnicas de Cultura , Humanos , Incidência , Luz , Microscopia de Fluorescência/instrumentação , Microscopia de Fluorescência/normas , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tuberculose Pulmonar/epidemiologia , Tuberculose Pulmonar/microbiologia , Tunísia/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA