Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiothorac Surg ; 19(1): 204, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38615010

RESUMO

INTRODUCTION: There are enough cases of colorectal cancer with liver metastasis, but inferior vena cava infiltraion with dissemination to the right atrium is an infrequent event. PRESENTATION OF CASE: This is the first case of surgical treatment of recurrent liver metastasis with the infiltration to the inferior vena cava and to the right atrium of the heart, using a cryopreserved pulmonary homograft. DISCUSSION: The choice of a cryopreserved pulmonary homograft was preferred by the need for a radical and wide resection of tissues involved in the metastasis, as well as to potentially reduce the risk of thrombosis in the short- and long-term postoperative period. CONCLUSION: The use of a cryopreserved homograft in operation undergoing cardiopulmonary bypass allowed us to perform the required volume of radical resection and to replace an extended section of the inferior vena cava.


Assuntos
Ponte Cardiopulmonar , Neoplasias Hepáticas , Humanos , Seguimentos , Átrios do Coração/cirurgia , Aloenxertos
2.
Clin Med Insights Cardiol ; 16: 11795468221120088, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36046179

RESUMO

Aims: To investigate the potential of a signal processed by smartphone-case based on single lead electrocardiogram (ECG) for left ventricular diastolic dysfunction (LVDD) determination as a screening method. Methods and Results: We included 446 subjects for sample learning and 259 patients for sample test aged 39 to 74 years for testing with 2D-echocardiography, tissue Doppler imaging and ECG using a smartphone-case based single lead ECG monitor for the assessment of LVDD. Spectral analysis of ECG signals (spECG) has been used in combination with advanced signal processing and artificial intelligence methods. Wavelengths slope, time intervals between waves, amplitudes at different points of the ECG complexes, energy of the ECG signal and asymmetry indices were analyzed. The QTc interval indicated significant diastolic dysfunction with a sensitivity of 78% and a specificity of 65%, a Tpeak parameter >590 ms with 63% and 58%, a T value off >695 ms with 63% and 74%, and QRSfi > 674 ms with 74% and 57%, respectively. A combination of the threshold values from all 4 parameters increased sensitivity to 86% and specificity to 70%, respectively (OR 11.7 [2.7-50.9], P < .001). Algorithm approbation have shown: Sensitivity-95.6%, Specificity-97.7%, Diagnostic accuracy-96.5% and Repeatability-98.8%. Conclusion: Our results indicate a great potential of a smartphone-case based on single lead ECG as novel screening tool for LVDD if spECG is used in combination with advanced signal processing and machine learning technologies.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA