Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
2.
J Endocrinol Invest ; 44(7): 1447-1456, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33067796

RESUMO

PURPOSE: Angiopoietin-like 8 (ANGPTL8) is a liver- and adipose tissue-produced protein that predicts non-alcoholic fatty liver disease (NAFLD) and altered metabolic homeostasis in the general population as well as in persons with common and genetic obesity, including the Prader-Willi syndrome (PWS). However, its metabolic correlate in paediatric patients with respect to PWS is unknown. METHODS: This cross-sectional study investigated circulating ANGPTL8 and adipocytokines levels in 28 PWS and 28 age-, sex- and BMI-matched children and adolescents (age, 7.0-17.8y) in relation to NAFLD and metabolic homeostasis assessed by OGTT, paediatric metabolic index (PMI) and fatty liver index (FLI), liver ultrasonography (US), as well as dual-energy X-ray absorptiometry (DEXA) for analysis of fat (FM) and fat-free mass (FFM). RESULTS: At the set level of significance, PWS children showed lower values of FFM (p < 0.01) but healthier insulin profiles (p < 0.01) and PMI values (p < 0.05) than matched controls. By US, the prevalence of NAFLD was similar between groups but less severe in PWS than controls. Analysis of ANGPTL8 levels showed no difference between groups, yet only in PWS ANGPTL8 levels were associated with ALT levels, FLI values and NAFLD. In stepwise multivariable regression analysis on merged data, ANGPTL8 levels were independently predicted by BMI SDS, leptin levels and NAFLD. CONCLUSION: ANGPTL8 levels are similar in PWS and controls and, overall, they are directly associated with the presence and severity of NAFLD in patients with PWS.


Assuntos
Proteína 8 Semelhante a Angiopoietina/sangue , Biomarcadores/sangue , Índice de Massa Corporal , Hepatopatia Gordurosa não Alcoólica/diagnóstico , Obesidade/fisiopatologia , Hormônios Peptídicos/sangue , Síndrome de Prader-Willi/complicações , Adolescente , Estudos de Casos e Controles , Criança , Estudos Transversais , Feminino , Seguimentos , Humanos , Masculino , Hepatopatia Gordurosa não Alcoólica/sangue , Hepatopatia Gordurosa não Alcoólica/etiologia , Hepatopatia Gordurosa não Alcoólica/patologia , Prognóstico
3.
Radiol Med ; 117(1): 54-71, 2012 Feb.
Artigo em Inglês, Italiano | MEDLINE | ID: mdl-21424318

RESUMO

PURPOSE: This study was undertaken to prospectively evaluate the diagnostic performance of colour Doppler ultrasonography (CDUS), first-pass (FP) and steady-state (SS) contrast-enhanced magnetic resonance angiography (MRA) and computed tomography angiography (CTA) of the carotid arteries using digital subtraction angiography (DSA) as the reference standard. MATERIALS AND METHODS: A total of 170 patients with previous cerebrovascular events and suspected carotid artery stenoses underwent CDUS, blood-pool MRA, CTA and DSA. Accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for CDUS, FP MRA, SS MRA and CTA. The McNemar and Wilcoxon tests and receiver operating characteristic (ROC) curve analysis were used to determine significant differences (p<0.05) between the diagnostic performances of the four modalities, and the degree of stenosis was compared using linear regression. RESULTS: A total of 336 carotid bifurcations were studied. The area under the curve (AUC) for degree of stenosis was: CDUS 0.85±0.02, FP MRA 0.982±0.005, SS MRA 0.994±0.002 and CTA 0.997±0.001. AUC analysis showed no statistically significant difference between CTA and MRA (p=0.0174) and a statistically significant difference between CDUS and the other techniques (p<0.001). Plaque morphology analysis showed no significant difference between CTA and SS MRA; a significant difference was seen between CTA and SS MRA versus FP MRA (p=0.04) and CDUS (p=0.038). Plaque ulceration analysis showed a statistically significant difference between MRA and CTA (0.04< p<0.046) versus CDUS (p=0.019). CONCLUSIONS: CTA is the most accurate technique for evaluating carotid stenoses, with a slightly better performance than MRA (97% vs. 95% for SS MRA and 92% for FP MRA) and a greater accuracy than CDUS (97% vs. 76%). Blood-pool contrast-enhanced SS sequences offer improved evaluation of degree of stenosis and plaque morphology with accuracy substantially identical to CTA.


Assuntos
Angiografia/métodos , Estenose das Carótidas/diagnóstico , Angiografia por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia Doppler em Cores/métodos , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Área Sob a Curva , Estenose das Carótidas/diagnóstico por imagem , Meios de Contraste , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade , Estatísticas não Paramétricas
4.
Radiol Med ; 115(4): 634-47, 2010 Jun.
Artigo em Inglês, Italiano | MEDLINE | ID: mdl-20177976

RESUMO

PURPOSE: The authors performed a preliminary study with blood-pool contrast-enhanced magnetic resonance angiography (MRA) in evaluating the degree of carotid artery stenosis and plaque morphology, comparing the diagnostic performance of first-pass (FP) and steady-state (SS) acquisitions with 64-slice computed tomography angiography (CTA) and using digital subtraction angiography (DSA) as the reference standard. MATERIALS AND METHODS: Twenty patients with >or=50% carotid artery stenosis at Doppler sonography underwent blood-pool contrast-enhanced MRA, CTA and DSA. Two independent radiologists evaluated MRA and CTA examinations to assess the degree of stenosis and characterise plaque morphology. Accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for FP, SS and CTA. The McNemar and Wilcoxon tests were used to determine significant differences (p<0.05) between the diagnostic performance of the three modalities. RESULTS: Forty carotid bifurcations were studied. For stenosis grading, accuracy, sensitivity, specificity, PPV and NPV were 90%, 89%, 90%, 89% and 90%, respectively, at FP; 95%, 95%, 95%, 95% and 95%, respectively, at SS; and 97.5%, 95%, 100%, 100% and 95%, respectively, at CTA. SS and CTA were superior to FP for evaluating the degree of stenosis (p<0.05). For evaluating plaque morphology, accuracy, sensitivity, specificity, PPV and NPV were 87.5%, 89%, 86%, 85% and 90%, respectively, at FP; 97.5%, 100%, 95%, 95% and 100%, respectively, at SS; and 100%, 100%, 100%, 100% and 100%, respectively, at CTA. There were no significant differences between FP, SS and CTA for plaque assessment (p>0.05). CONCLUSIONS: Blood-pool contrast-enhanced MRA with SS sequences allow improved diagnostic evaluation of the degree of carotid stenosis and plaque morphology compared with FP and is substantially equal to CTA and DSA.


Assuntos
Estenose das Carótidas/diagnóstico por imagem , Meios de Contraste , Gadolínio , Angiografia por Ressonância Magnética , Compostos Organometálicos , Angiografia/métodos , Angiografia Digital , Estenose das Carótidas/patologia , Humanos , Tomografia Computadorizada por Raios X
5.
Radiol Med ; 114(7): 1065-79, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19774440

RESUMO

PURPOSE: This study was undertaken to compare the accuracy of magnetic resonance (MR) imaging and 64-slice multidetector computed tomography (64-MDCT) in the T staging of gastric carcinoma in comparison with histopathology. MATERIALS AND METHODS: Forty patients with an endoscopic diagnosis of gastric carcinoma underwent preoperative MR imaging and 64-MDCT, both of which were performed after i.v. injection of scopolamine and water distension of the stomach. In the MR imaging protocol, we acquired T2-weighted turbo spin-echo (TSE) sequences, true fast imaging steady-state free precession (true-FISP) and gadolinium-enhanced T1-weighted volumetric interpolated breath-hold examination (VIBE) 3D sequences. Contrastenhanced CT scans were obtained in the arterial and venous phases. Two groups of radiologists independently reviewed the MR and 64-MDCT images. The results were compared with pathology findings. RESULTS: In the evaluation of T stage, 64-MDCT had 82.5% and MR imaging had 80% sensitivity. Accuracy of MR imaging was slightly higher than that of 64-MDCT in identifying T1 lesions (50% vs 37.5%), whereas the accuracy of 64-MDCT was higher in differentiating T2 lesions (81.2% vs 68.7%). The accuracy of MR imaging and 64-MDCT did not differ significantly in the evaluation of T3-T4 lesions (p>0.05). Understaging was observed in 20% of cases with MR imaging and in 17.5% with 64-MDCT. CONCLUSIONS: MR imaging and 64-MDCT accuracy levels did not differ in advanced stages of disease, whereas MR imaging was superior in identifying early stages of gastric cancer and can be considered a valid alternative to MDCT in clinical practice.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/patologia , Tomografia Computadorizada por Raios X , Biópsia , Meios de Contraste , Feminino , Gastroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Sensibilidade e Especificidade
6.
Radiol Med ; 114(4): 538-52, 2009 Jun.
Artigo em Inglês, Italiano | MEDLINE | ID: mdl-19430733

RESUMO

PURPOSE: This study was performed to validate a high-resolution whole-body magnetic resonance angiography (MRA) protocol with parallel imaging and biphasic administration of a single bolus of contrast agent in the preliminary assessment of systemic atherosclerotic burden in patients referred for endovascular procedures. MATERIALS AND METHODS: Forty patients referred for endovascular treatment of atherosclerotic disease of the carotid arteries (n=23), peripheral vessels (n=14) or aorta (n=3) on the basis of previous clinical and diagnostic examinations underwent high-resolution whole-body MRA at 1.5 T with 3D spoiled gradient recalled echo (GRE) sequences, featuring parallel imaging acquisition technique with x2 acceleration factor. Sixty-eight surface coil elements and a four-station imaging protocol were employed. Biphasic intravenous administration of a paramagnetic contrast agent [gadolinium benzyloxyproprionic-tetraacetic acid (Gd-BOPTA)] was performed with the following protocol: 10 ml at a speed of 1 ml/s followed by further 10 ml at a speed of 0.5 ml/s. For image analysis, the arterial system was divided into 42 segments for evaluation. The presence or absence of atherosclerotic lesions was evaluated by two observers in consensus; segments were classified as having clinically significant disease (>or=50% stenosis or an aneurysmal dilatation) or no significant disease (<50% stenosis). The presence of stenoocclusive disease, determined at all segments, was compared with findings on digital subtraction angiography (DSA), which were interpreted by a third independent reader. Sensitivity, specificity and concordance of whole-body MRA findings with DSA were calculated, and receiver operating characteristic (ROC) analysis was performed for all vascular territories. RESULTS: A total of 1,680 arterial segments was evaluated; 138 (8.3%) were affected by atherosclerotic alterations. Carotid lesions were confirmed in 23 patients (34 segments), involvement of peripheral vessels in 14 (57 segments) and abdominal aneurysms in three. Sensitivity and specificity of whole-body MRA were, respectively, 95%-97% for head and neck vessels, 100%-100% for thoracoabdominal vessels, 98%-97% for thigh vessels and 84%-88% for calf vessels; concordance with the DSA findings was significant (p<0.05). Subclinical atherosclerotic lesions were evidenced in 25 patients, involving carotid arteries (12 segments), peripheral vessels (21 segments) and abdominal aorta (one segment). All these lesions were confirmed by a second modality, and ten of these patients required further care. CONCLUSIONS: High-resolution whole-body MRA with Gd-BOPTA may be considered a reliable modality for imaging systemic atherosclerosis in candidates for endovascular procedures. The subclinical detection of the total atherosclerotic burden has potential implications for secondary care in this population.


Assuntos
Aterosclerose/diagnóstico , Meios de Contraste , Angiografia por Ressonância Magnética , Meglumina/análogos & derivados , Compostos Organometálicos , Procedimentos Cirúrgicos Vasculares , Imagem Corporal Total/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Aorta/patologia , Arteriopatias Oclusivas/diagnóstico , Aterosclerose/cirurgia , Estenose das Carótidas/diagnóstico , Protocolos Clínicos , Feminino , Humanos , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Doenças Vasculares Periféricas/diagnóstico , Valor Preditivo dos Testes , Cuidados Pré-Operatórios , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/métodos
7.
Radiol Med ; 113(6): 799-816, 2008 Sep.
Artigo em Inglês, Italiano | MEDLINE | ID: mdl-18594763

RESUMO

PURPOSE: The aim of this study was to validate a 64-row multidetector computed tomography (64-MDCT) acquisition protocol with biphasic administration of contrast medium for comprehensive assessment of the coronary and systemic arterial tree in a single examination. MATERIALS AND METHODS: The scanning protocol comprised two acquisitions: an electrocardiograph (ECG)-gated scan at the level of the heart, followed by a total-body, low-dose scan of the systemic arterial circulation. Twenty patients were evaluated using two different strategies for contrast administration. In ten patients, the delay between the two acquisitions was set at 40 s, whereas in the remaining patients, it varied between 45 s and 65 s. For both strategies, the degree of systemic arterial opacification and the attenuation gradient between arterial and venous structures were quantitatively assessed at six extracoronary locations. Two observers evaluated in consensus the presence or absence of atherosclerosis and the degree of stenosis of arterial segments. RESULTS: Three hundred coronary segments were analysed. Arterial-wall changes were depicted in 155 (51%) segments, and in 35 (23%), the degree of stenosis was > 50%. Of the 640 extracoronary arterial segments, 250 (39%) presented atherosclerotic wall alterations, in 50 (20%), the degree of stenosis was > 50% and five were affected by aneurysmal dilatation. The magnitude of arterial opacification values and attenuation gradients between arterial and venous structures were significantly higher in patients scanned with the 40-s fixed-delay strategy. CONCLUSIONS: Whole-body CT angiography with biphasic administration of contrast agent and fixed scan delay has been shown to be a feasible and reproducible technique. Comprehensive data on the global atherosclerotic burden potentially offer important therapeutic options for subclinical, high-risk segments.


Assuntos
Angiografia/métodos , Aterosclerose/diagnóstico por imagem , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos , Idoso , Circulação Sanguínea , Índice de Massa Corporal , Protocolos Clínicos , Meios de Contraste , Doença das Coronárias/genética , Interpretação Estatística de Dados , Eletrocardiografia , Estudos de Viabilidade , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica
8.
Minerva Cardioangiol ; 55(3): 291-301, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17534247

RESUMO

AIM: Recently whole-body 3D MR angiography (MRA) with blood-pool contrast agent has become available. The purpose of this study was to introduce and evaluate this technique to demonstrate arterial steno-occlusive involvement in systemic atherosclerosis and to compare blood-pool enhanced MRA results with those of CT angiography (CTA) as reference modality. METHODS: Twenty patients with clinically and US documented carotid occlusive disease underwent whole-body MRA on a 1.5 T scanner and CTA on a 64-MDCT unit. Ten milliliters of a blood-pool agent (MS-235 Gadofosveset Trisodium, VASOVIST, Schering, Berlin, Germany) were administered intravenously and four 3-D MRA stations were acquired successively through automatic table moving. Images were reviewed by two observers. Overall image quality of each arterial segment was assessed and rated for both MRA and CTA examinations; MRA sensitivity, MRA specificity interobserver and intermodality agreement were calculated. RESULTS: Whole-body MRA with blood-pool contrast agent was well tolerated by all patients. It yielded a detailed display of the arterial system with a short examination time. In 14 out of 20 patients there was extensive involvement of the arterial bed by steno-occlusive atherosclerotic disease; for the identification and characterization of vessel damage in the various vascular districts MRA sensitivity was 92-100%, MRA specificity was 95-100%; in 2 cases MRA underestimated the degree of peripheral vessel stenosis. Interobserver agreement calculated with K value was 0.63, intermodality agreement with CTA was 93% (P<0.01). CONCLUSION: The whole-body MRA technique is a valuable tool for comprehensive evaluation of arterial steno-occlusive involvement in systemic arterial atherosclerosis; there is a good agreement between blood-pool enhanced MRA results and CTA, used as modality of reference.


Assuntos
Aterosclerose/diagnóstico , Meios de Contraste/administração & dosagem , Angiografia por Ressonância Magnética , Imagem Corporal Total/métodos , Idoso , Feminino , Humanos , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
9.
Boll Soc Ital Biol Sper ; 70(8-9): 193-8, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-7893476

RESUMO

Blood hormonal levels and lymphocyte beta-adrenoceptor characteristics have been studied in subjects exposed to acute noise stress. Cortisol and DHEAS show a peak at 15 min after the beginning of the stimulus. Catecholamine levels show an increase in 4 out of 8 subjects. However, no statistically significant changes have been observed in beta-adrenoceptor characteristics.


Assuntos
Catecolaminas/sangue , Linfócitos/metabolismo , Ruído , Receptores Adrenérgicos/metabolismo , Feminino , Hormônios/metabolismo , Humanos , Masculino , Estresse Fisiológico/metabolismo
11.
Laryngol Rhinol Otol (Stuttg) ; 59(3): 198-206, 1980 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-7442404

RESUMO

Authors observed in cases of kryptogenetic diseases of cranial nerves V, VII and VIII a significant higher frequency of well pneumatized petrous portion of the temporal bone than in normal population. They suppose that, parallel to the symptoms of Eustachian tube occlusion in the middle ear region, the "Vacuum Petrosum" causes these disturbances of cranial nerve functions and try to interpret the mechanism in the particular cases.


Assuntos
Doenças dos Nervos Cranianos/patologia , Osso Petroso/patologia , Doenças dos Nervos Cranianos/diagnóstico por imagem , Tuba Auditiva/patologia , Nervo Facial/patologia , Humanos , Osso Petroso/diagnóstico por imagem , Radiografia , Nervo Trigêmeo/patologia , Nervo Vestibulococlear/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA