Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Rheumatol Int ; 39(4): 707-713, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30539275

RESUMO

The aim of this study was to evaluate the reliability of the outcome measures in rheumatology (OMERACT) definitions for ultrasound (US) elementary lesions in gout through an image reading exercise. Images from patients with gout (static images and videos) were collected. As an initial step, we carried out a image reading exercise within the experts of the Pan-American League of Associations for Rheumatology (PANLAR) US Study Group (n = 16). The following step consisted in a web-based exercise with the participation of larger number of sonographers (n = 63) from different centers. Images were rated evaluating the presence/absence of any US elementary lesion. Inter- and intra-reader reliabilities were analyzed using kappa coefficients. Participants were stratified according to their level of experience. In the first exercise, inter-reader kappa values were 0.45 for aggregates, 0.57 for tophus, 0.69 for erosions, and 0.90 for double contour (DC). Intra-reader kappa values were 0.86, 0.76, 0.80, and 0.90, respectively. The web-based exercise showed inter-reader kappa values for aggregates, tophus, erosions, and DC of 0.42, 0.49, 0.69, and 0.79, respectively. The intra-reader kappa values were 0.62, 0.69, 0.77, and 0.85, respectively. Reliability was not influenced by the sonographer's level of experience. The reliability of the new OMERACT US definitions for elementary lesions in gout ranged from moderate to excellent, depending on the type of lesion.


Assuntos
Gota/diagnóstico por imagem , Estudos Transversais , Humanos , Reprodutibilidade dos Testes , Ultrassonografia
2.
Ann Rheum Dis ; 77(8): 1194-1199, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29535120

RESUMO

OBJECTIVES: To assess the reliability of the OMERACT ultrasound (US) definitions for the identification of calcium pyrophosphate deposition disease (CPPD) at the metacarpal-phalangeal, triangular fibrocartilage of the wrist (TFC), acromioclavicular (AC) and hip joints. METHODS: A web-based exercise and subsequent patient-based exercise were carried out. A panel of 30 OMERACT members, participated at the web-based exercise by evaluating twice a set of US images for the presence/absence of CPPD. Afterwards, 19 members of the panel met in Siena, Italy, for the patient-based exercise. During the exercise, all sonographers examined twice eight patients for the presence/absence of CPPD at the same joints. Intraoberserver and interobserver kappa values were calculated for both exercises. RESULTS: The web-based exercise yielded high kappa values both in intraobserver and interobserver evaluation for all sites, while in the patient-based exercise, inter-reader agreement was acceptable for the TFC and the AC. TFC reached high interobserver and intraobserver k values in both exercises, ranging from 0.75 to 0.87 (good to excellent agreement). AC reached moderate kappa values, from 0.51 to 0.85 (moderate to excellent agreement) and can readily be used for US CPPD identification. CONCLUSIONS: Based on the results of our exercise, the OMERACT US definitions for the identification of CPPD demonstrated to be reliable when applied to the TFC and AC. Other sites reached good kappa values in the web-based exercise but failed to achieve good reproducibility at the patient-based exercise, meaning the scanning method must be further refined.


Assuntos
Condrocalcinose/diagnóstico por imagem , Ultrassonografia/normas , Articulação Acromioclavicular/diagnóstico por imagem , Idoso , Feminino , Articulação do Quadril/diagnóstico por imagem , Humanos , Cooperação Internacional , Internet , Masculino , Articulação Metacarpofalângica/diagnóstico por imagem , Pessoa de Meia-Idade , Variações Dependentes do Observador , Sistemas de Informação em Radiologia , Reprodutibilidade dos Testes , Ultrassonografia/métodos , Articulação do Punho/diagnóstico por imagem
3.
Acta méd. colomb ; 31(2): 83-91, abr.-jun. 2006. tab, graf
Artigo em Espanhol | LILACS | ID: lil-436712

RESUMO

La escleroderma es un desorden que afecta la piel y algunas vísceras, generando una alteración tanto a nivel inmunológico, vascular y de tejido conectivo, lo cual conlleva a la presencia de fibrosis y alteración sistémica; en la siguiente revisión se discute el estado del arte en las opciones de tratamiento disponibles hasta el momento, realizando un analisis sistemático de cada uno de los artículos que abordan el tema y que se encuentran referenciados en bases de datos como medline, lilacs y bireme, se dividen los tratamientos de acuerdo con el mecanismo fisiopatogénico especifico sobre el cual actúan en la resolución de la enfermedad, lo anterior con el fin de abordar ampliamente este tópico y dar pautas claras acerca del estado actual del tratamiento y las implicaciones clínicas de las nuevas opciones disponibles.


Assuntos
Fibrose , Esclerodermia Difusa , Escleroderma Sistêmico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA