Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Biomicrofluidics ; 14(3): 034101, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32454925

RESUMO

Real-time observation and control of particle size and production rate in microfluidic devices are important capabilities for a number of applications, including the production, sorting, and manipulation of microbubbles and droplets. The production of microbubbles from flow-focusing microfluidic devices had been investigated in multiple studies, but each lacked an approach for on-chip measurement and control of microbubble diameter in real time. In this work, we implement a closed-loop feedback control system in a flow-focusing microfluidic device with integrated on-chip electrodes. Using our system, we measure and count microbubbles between 13 and 28 µ m in diameter and control their diameter using a proportional-integral controller. We validate our measurements against an optical benchmark with R 2 = 0.98 and achieve a maximum production rate of 1.4 × 10 5 /s. Using the feedback control system, the device enabled control in microbubble diameter over the range of 14-24 µ m.

2.
J Anesth Clin Res ; 10(2)2019.
Artigo em Inglês | MEDLINE | ID: mdl-31179158

RESUMO

BACKGROUND: This study evaluated the efficacy of spinal anesthesia administration by resident physicians when using an ultrasound system with automated neuraxial landmark detection capabilities. METHODS: 150 patients were enrolled in this trial. Anesthesiology residents placed spinals in subjects undergoing scheduled cesarean delivery using one of three techniques to identify neuraxial landmarks: palpation, ultrasound, or combined palpation and ultrasound. Ultrasound was performed using a handheld system that automatically identified neuraxial landmarks (e.g. midline, intervertebral spaces). All residents watched a 10-minute video and received 20 minutes of hands-on training prior to participating in the study. First insertion success rate was the primary end point. RESULTS: Among all patients, use of ultrasound resulted in a 11% greater first-insertion success rate (RR: 1.11 [0.85-1.47], p=0.431), a 15% reduction in needle insertions (RR: 0.85, p=0.052), and a 26% decrease in needle passes (RR: 0.74, p=0.070). In obese patients of BMI ≥ 30 kg/m2, use of ultrasound resulted in 26% greater first-insertion success rates (RR: 1.26, p=0.187), a 21% decrease in needle insertions (RR: 0.79, p=0.025), a 38% decrease in needle passes (RR: 0.62, p=0.030), and a 75% decrease in patients reporting neutral or low patient satisfaction with anesthesia administration (RR: 0.25, p=0.004). DISCUSSION: Resident anesthesiologists competently utilized the ultrasound system after receiving minimal training. Technical endpoints and patient satisfaction trended towards improvement when ultrasound was used prior to spinal placement, with stronger trends observed in obese patients. Additional study is required to fully characterize the impact of the ultrasound system on clinical efficacy.

3.
Lab Chip ; 19(10): 1887, 2019 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-31026008

RESUMO

Correction for 'A flow focusing microfluidic device with an integrated Coulter particle counter for production, counting and size characterization of monodisperse microbubbles' by J. M. Robert Rickel et al., Lab Chip, 2018, 18, 2653-2664.

4.
Ann Biomed Eng ; 47(4): 1012-1022, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30689066

RESUMO

Limitations of existing thrombolytic therapies for acute ischemic stroke have motivated the development of catheter-based approaches that utilize no or low doses of thrombolytic drugs combined with a mechanical action to either dissolve or extract the thrombus. Sonothrombolysis accelerates thrombus dissolution via the application of ultrasound combined with microbubble contrast agents and low doses of thrombolytics to mechanically disrupt the fibrin mesh. In this work, we studied the efficacy of catheter-directed sonothrombolysis in a rat model of ischemic stroke. Microbubbles of 10-20 µm diameter with a nitrogen gas core and a non-crosslinked albumin shell were produced by a flow-focusing microfluidic device in real time. The microbubbles were dispensed from a catheter located in the internal carotid artery for direct delivery to the thrombus-occluded middle cerebral artery, while ultrasound was administered through the skull and recombinant tissue plasminogen activator (rtPA) was infused via a tail vein catheter. The results of this study demonstrate that flow focusing microfluidic devices can be miniaturized to dimensions compatible with human catheterization and that large-diameter microbubbles comprised of high solubility gases can be safely administered intraarterially to deliver a sonothrombolytic therapy. Further, sonothrombolysis using intraarterial delivery of large microbubbles reduced cerebral infarct volumes by approximately 50% vs. no therapy, significantly improved functional neurological outcomes at 24 h, and permitted rtPA dose reduction of 3.3 (95% CI 1.8-3.8) fold when compared to therapy with intravenous rtPA alone.


Assuntos
Isquemia Encefálica/terapia , Microbolhas , Acidente Vascular Cerebral/terapia , Terapia Trombolítica , Ativador de Plasminogênio Tecidual/farmacologia , Terapia por Ultrassom , Animais , Isquemia Encefálica/patologia , Isquemia Encefálica/fisiopatologia , Modelos Animais de Doenças , Microfluídica , Ratos , Acidente Vascular Cerebral/patologia , Acidente Vascular Cerebral/fisiopatologia
5.
Lab Chip ; 18(17): 2653-2664, 2018 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-30070301

RESUMO

Flow focusing microfluidic devices (FFMDs) have been investigated for the production of monodisperse populations of microbubbles for chemical, biomedical and mechanical engineering applications. High-speed optical microscopy is commonly used to monitor FFMD microbubble production parameters, such as diameter and production rate, but this limits the scalability and portability of the approach. In this work, a novel FFMD design featuring integrated electronics for measuring microbubble diameters and production rates is presented. A micro Coulter particle counter (µCPC), using electrodes integrated within the expanding nozzle of an FFMD (FFMD-µCPC), was designed, fabricated and tested. Finite element analysis (FEA) of optimal electrode geometry was performed and validated with experimental data. Electrical data was collected for 8-20 µm diameter microbubbles at production rates up to 3.25 × 105 MB s-1 and compared to both high-speed microscopy data and FEA simulations. Within a valid operating regime, Coulter counts of microbubble production rates matched optical reference values. The Coulter method agreed with the optical reference method in evaluating the microbubble diameter to a coefficient of determination of R2 = 0.91.


Assuntos
Dispositivos Lab-On-A-Chip , Microbolhas , Análise de Elementos Finitos
6.
Ann Biomed Eng ; 46(2): 222-232, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29192346

RESUMO

Therapeutic approaches that enhance thrombolysis by combining recombinant tissue plasminogen activator (rtPA), ultrasound, and/or microbubbles (MBs) are known as sonothrombolysis techniques. To date, sonothrombolysis approaches have primarily utilized commercially available MB formulations (or derivatives thereof) with diameters in the range 1-4 µm and circulation lifetimes between 5 and 15 min. The present study evaluated the in vitro sonothrombolysis efficacy of large diameter MBs (d MB ≥ 10 µm) with much shorter lifetimes that were produced on demand and in close proximity to the blood clot using a flow-focusing microfluidic device. MBs with a N2 gas core and a non-crosslinked bovine serum albumin shell were produced with diameters between 10 and 20 µm at rates between 50 and 950 × 103 per second. Use of these large MBs resulted in approximately 4.0-8.8 fold increases in thrombolysis rates compared to a clinical rtPA dose and approximately 2.1-4.2 fold increases in thrombolysis rates compared to sonothrombolysis techniques using conventional MBs. The results of this study indicate that the large diameter microbubbles with transient stability are capable of significantly enhanced in vitro sonothrombolysis rates when delivered directly to the clot immediately following production by a flow focusing microfluidic device placed essentially in situ adjacent to the clot.


Assuntos
Dispositivos Lab-On-A-Chip , Microbolhas , Nitrogênio/química , Terapia Trombolítica , Ativador de Plasminogênio Tecidual/química , Animais , Bovinos , Humanos , Soroalbumina Bovina/química , Terapia Trombolítica/instrumentação , Terapia Trombolítica/métodos
7.
Invest Radiol ; 52(8): 447-455, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28230717

RESUMO

OBJECTIVES: The aim of this study was to evaluate the imaging performance of a handheld ultrasound system and the accuracy of an automated lumbar spine computer-aided detection (CAD) algorithm in the spines of human subjects. MATERIALS AND METHODS: This study was approved by the institutional review board of the University of Virginia. The authors designed a handheld ultrasound system with enhanced bone image quality and fully automated CAD of lumbar spine anatomy. The imaging performance was evaluated by imaging the lumbar spines of 68 volunteers with body mass index between 18.5 and 48 kg/m. The accuracy, sensitivity, and specificity of the lumbar spine CAD algorithm were assessed by comparing the algorithm's results to ground-truth segmentations of neuraxial anatomy provided by radiologists. RESULTS: The lumbar spine CAD algorithm detected the epidural space with a sensitivity of 94.2% (95% confidence interval [CI], 85.1%-98.1%) and a specificity of 85.5% (95% CI, 81.7%-88.6%) and measured its depth with an error of approximately ±0.5 cm compared with measurements obtained manually from the 2-dimensional ultrasound images. The spine midline was detected with a sensitivity of 93.9% (95% CI, 85.8%-97.7%) and specificity of 91.3% (95% CI, 83.6%-96.9%), and its lateral position within the ultrasound image was measured with an error of approximately ±0.3 cm. The bone enhancement imaging mode produced images with 5.1- to 10-fold enhanced bone contrast when compared with a comparable handheld ultrasound imaging system. CONCLUSIONS: The results of this study demonstrate the feasibility of CAD for assisting with real-time interpretation of ultrasound images of the lumbar spine at the bedside.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Vértebras Lombares/anatomia & histologia , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Adulto , Algoritmos , Estudos de Viabilidade , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Bioconjug Chem ; 27(2): 383-90, 2016 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-26603129

RESUMO

Magnetic resonance (MR) and photoacoustic (PA) imaging are currently being investigated as complementing strategies for applications requiring sensitive detection of cells in vivo. While combined MR/PAI detection of cells requires biocompatible cell labeling probes, water-based synthesis of dual-modality MR/PAI probes presents significant technical challenges. Here we describe facile synthesis and characterization of hybrid modular dextran-stabilized gold/iron oxide (Au-IO) multimetallic nanoparticles (NP) enabling multimodal imaging of cells. The stable association between the IO and gold NP was achieved by priming the surface of dextran-coated IO with silver NP resulting from silver(I) reduction by aldehyde groups, which are naturally present within the dextran coating of IO at the level of 19-23 groups/particle. The Au-IO NP formed in the presence of silver-primed Au-IO were stabilized by using partially thiolated MPEG5-gPLL graft copolymer carrying residual amino groups. This stabilizer served as a carrier of near-infrared fluorophores (e.g., IRDye 800RS) for multispectral PA imaging. Dual modality imaging experiments performed in capillary phantoms of purified Au-IO-800RS NPs showed that these NPs were detectible using 3T MRI at a concentration of 25 µM iron. PA imaging achieved approximately 2.5-times higher detection sensitivity due to strong PA signal emissions at 530 and 770 nm, corresponding to gold plasmons and IRDye integrated into the coating of the hybrid NPs, respectively, with no "bleaching" of PA signal. MDA-MB-231 cells prelabeled with Au-IO-800RS retained plasma membrane integrity and were detectable by using both MR and dual-wavelength PA at 49 ± 3 cells/imaging voxel. We believe that modular assembly of multimetallic NPs shows promise for imaging analysis of engineered cells and tissues with high resolution and sensitivity.


Assuntos
Meios de Contraste/química , Dextranos/química , Compostos Férricos/química , Ouro/química , Imageamento por Ressonância Magnética/métodos , Nanopartículas/química , Técnicas Fotoacústicas/métodos , Linhagem Celular Tumoral , Meios de Contraste/farmacocinética , Dextranos/farmacocinética , Compostos Férricos/farmacocinética , Ouro/farmacocinética , Humanos , Nanopartículas Metálicas , Imagem Multimodal/métodos
9.
Artigo em Inglês | MEDLINE | ID: mdl-26415129

RESUMO

Intravascular ultrasound (IVUS) provides radiation-free, real-time imaging and assessment of atherosclerotic disease in terms of anatomical, functional, and molecular composition. The primary clinical applications of IVUS imaging include assessment of luminal plaque volume and real-time image guidance for stent placement. When paired with microbubble contrast agents, IVUS technology may be extended to provide nonlinear imaging, molecular imaging, and therapeutic delivery modes. In this review, we discuss the development of emerging imaging and therapeutic applications that are enabled by the combination of IVUS imaging technology and microbubble contrast agents.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Microbolhas , Ultrassonografia de Intervenção/métodos , Animais , Artérias Carótidas/diagnóstico por imagem , Humanos , Coelhos , Suínos
10.
Opt Lett ; 40(6): 910-3, 2015 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-25768144

RESUMO

Capitalizing on the optical absorption of hemoglobin, photoacoustic microscopy (PAM) is uniquely capable of anatomical and functional characterization of the intact microcirculation in vivo. However, PAM of the metabolic rate of oxygen (MRO2) at the microscopic level remains an unmet challenge, mainly due to the inability to simultaneously quantify microvascular diameter, oxygen saturation of hemoglobin (sO2), and blood flow at the same spatial scale. To fill this technical gap, we have developed a multi-parametric PAM platform. By analyzing both the sO2-encoded spectral dependence and the flow-induced temporal decorrelation of photoacoustic signals generated by the raster-scanned mouse ear vasculature, we demonstrated-for the first time-simultaneous wide-field PAM of all three parameters down to the capillary level in vivo.


Assuntos
Microcirculação , Microscopia/métodos , Microvasos/anatomia & histologia , Microvasos/fisiologia , Oxigênio/metabolismo , Técnicas Fotoacústicas/métodos , Animais , Orelha/irrigação sanguínea , Hemoglobinas/metabolismo , Camundongos , Microscopia/instrumentação , Microvasos/metabolismo , Imagens de Fantasmas , Técnicas Fotoacústicas/instrumentação
11.
Biomed Microdevices ; 17(1): 23, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25663444

RESUMO

Microfluidics-based production of stable microbubbles for ultrasound contrast enhancement or drug/gene delivery allows for precise control over microbubble diameter but at the cost of a low production rate. In situ microfluidic production of microbubbles directly in the vasculature may eliminate the necessity for high microbubble production rates, long stability, or small diameters. Towards this goal, we investigated whether microfluidic-produced microbubbles directly administered into a mouse tail vein could provide sufficient ultrasound contrast. Microbubbles composed of nitrogen gas and stabilized with 3 % bovine serum albumin and 10 % dextrose were injected for 10 seconds into wild type C57BL/6 mice, via a tail-vein catheter. Short-axis images of the right and left ventricle were acquired at 12.5 MHz and image intensity over time was analyzed. Microbubbles were produced on the order of 10(5) microbubbles/s and were observed in both the right and left ventricles. The median rise time, duration, and decay time within the right ventricle were 2.9, 21.3, and 14.3 s, respectively. All mice survived the procedure with no observable respiratory or heart rate distress despite microbubble diameters as large as 19 µm.


Assuntos
Meios de Contraste , Microbolhas , Técnicas Analíticas Microfluídicas/métodos , Ultrassonografia/métodos , Animais , Bovinos , Meios de Contraste/química , Meios de Contraste/farmacologia , Camundongos , Nitrogênio/química , Nitrogênio/farmacologia , Soroalbumina Bovina/química , Soroalbumina Bovina/farmacologia
12.
Small ; 11(25): 3066-77, 2015 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-25703465

RESUMO

Microbubbles bearing plasmonic nanoparticles on their surface provide contrast enhancement for both photoacoustic and ultrasound imaging. In this work, the responses of microbubbles with surface-bound gold nanorods-termed AuMBs-to nanosecond pulsed laser excitation are studied using high-speed microscopy, photoacoustic imaging, and numerical modeling. In response to laser fluences below 5 mJ cm(-2) , AuMBs produce weak photoacoustic emissions and exhibit negligible microbubble wall motion. However, in reponse to fluences above 5 mJ cm(-2) , AuMBs undergo dramatically increased thermal expansion and emit nonlinear photoacoustic waves of over 10-fold greater amplitude than would be expected from freely dispersed gold nanorods. Numerical modeling suggests that AuMB photoacoustic responses to low laser fluences result from conductive heat transfer from the surface-bound nanorods to the microbubble gas core, whereas at higher fluences, explosive boiling may occur at the nanorod surface, producing vapor nanobubbles that contribute to rapid AuMB expansion. The results of this study indicate that AuMBs are capable of producing acoustic emissions of significantly higher amplitude than those produced by conventional sources of photoacoustic contrast. In vivo imaging performance of AuMBs in a murine kidney model suggests that AuMBs may be an effective alternative to existing contrast agents for noninvasive photoacoustic and ultrasound imaging applications.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Ouro/química , Nanopartículas Metálicas/química , Microbolhas , Técnicas Fotoacústicas/métodos , Ressonância de Plasmônio de Superfície/métodos , Materiais Revestidos Biocompatíveis/síntese química , Meios de Contraste/síntese química , Ouro/efeitos da radiação , Aumento da Imagem/métodos , Teste de Materiais , Nanopartículas Metálicas/efeitos da radiação , Nanopartículas Metálicas/ultraestrutura , Oscilometria/métodos
13.
Ultrasound Med Biol ; 40(2): 400-9, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24342914

RESUMO

We describe a method for synthesizing albumin-shelled, large-diameter (>10 µm), transiently stable microbubbles using a flow-focusing microfluidic device (FFMD). The microfluidic device enables microbubbles to be produced immediately before insonation, thus relaxing the requirements for stability. Both reconstituted fractionated bovine serum albumin (BSA) and fresh bovine blood plasma were investigated as shell stabilizers. Microbubble coalescence was inhibited by the addition of either dextrose or glycerol and propylene glycol. Microbubbles were observed to have an acoustic half-life of approximately 6 s. Microbubbles generated directly within a vessel phantom containing flowing blood produced a 6.5-dB increase in acoustic signal within the lumen. Microbubbles generated in real time upstream of in vitro rat aortic smooth muscle cells under physiologic flow conditions successfully permeabilized 58% of the cells on insonation at a peak negative pressure of 200 kPa. These results indicate that transiently stable microbubbles produced via flow-focusing microfluidic devices are capable of image enhancement and drug delivery. In addition, successful microbubble production with blood plasma suggests the potential to use blood as a stabilizing shell.


Assuntos
Meios de Contraste/síntese química , Microbolhas , Técnicas Analíticas Microfluídicas/instrumentação , Músculo Liso Vascular/diagnóstico por imagem , Miócitos de Músculo Liso/diagnóstico por imagem , Albumina Sérica/química , Ultrassonografia/instrumentação , Animais , Células Cultivadas , Materiais Revestidos Biocompatíveis/síntese química , Composição de Medicamentos/instrumentação , Estabilidade de Medicamentos , Desenho de Equipamento , Análise de Falha de Equipamento , Imagens de Fantasmas , Ratos
14.
Ultrasound Med Biol ; 39(7): 1267-76, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23643062

RESUMO

Focal drug delivery to a vessel wall facilitated by intravascular ultrasound and microbubbles holds promise as a potential therapy for atherosclerosis. Conventional methods of microbubble administration result in rapid clearance from the bloodstream and significant drug loss. To address these limitations, we evaluated whether drug delivery could be achieved with transiently stable microbubbles produced in real time and in close proximity to the therapeutic site. Rat aortic smooth muscle cells were placed in a flow chamber designed to simulate physiological flow conditions. A flow-focusing microfluidic device produced 8 µm diameter monodisperse microbubbles within the flow chamber, and ultrasound was applied to enhance uptake of a surrogate drug (calcein). Acoustic pressures up to 300 kPa and flow rates up to 18 mL/s were investigated. Microbubbles generated by the flow-focusing microfluidic device were stabilized with a polyethylene glycol-40 stearate shell and had either a perfluorobutane (PFB) or nitrogen gas core. The gas core composition affected stability, with PFB and nitrogen microbubbles exhibiting half-lives of 40.7 and 18.2 s, respectively. Calcein uptake was observed at lower acoustic pressures with nitrogen microbubbles (100 kPa) than with PFB microbubbles (200 kPa) (p < 0.05, n > 3). In addition, delivery was observed at all flow rates, with maximal delivery (>70% of cells) occurring at a flow rate of 9 mL/s. These results demonstrate the potential of transiently stable microbubbles produced in real time and in close proximity to the intended therapeutic site for enhancing localized drug delivery.


Assuntos
Sistemas de Liberação de Medicamentos/instrumentação , Fluoresceínas/farmacocinética , Microbolhas/uso terapêutico , Técnicas Analíticas Microfluídicas/instrumentação , Miócitos de Músculo Liso/metabolismo , Miócitos de Músculo Liso/efeitos da radiação , Sonicação/instrumentação , Animais , Células Cultivadas , Desenho de Equipamento , Análise de Falha de Equipamento , Ratos
15.
J Biomed Opt ; 18(5): 56009, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23698320

RESUMO

Intravascular near-infrared fluorescence (NIRF) imaging offers a new approach for characterizing atherosclerotic plaque, but random catheter positioning within the vessel lumen results in variable light attenuation and can yield inaccurate measurements. We hypothesized that NIRF measurements could be corrected for variable light attenuation through blood by tracking the location of the NIRF catheter with intravascular ultrasound (IVUS). In this study, a combined NIRF-IVUS catheter was designed to acquire coregistered NIRF and IVUS data, an automated image processing algorithm was developed to measure catheter-to-vessel wall distances, and depth-dependent attenuation of the fluorescent signal was corrected by an analytical light propagation model. Performance of the catheter sensing distance correction method was evaluated in coronary artery phantoms and ex vivo arteries. The correction method produced NIRF estimates of fluorophore concentrations, in coronary artery phantoms, with an average root mean square error of 17.5%. In addition, the correction method resulted in a statistically significant improvement in correlation between spatially resolved NIRF measurements and known fluorophore spatial distributions in ex vivo arteries (from r = 0.24 to 0.69, p < 0.01, n = 6). This work demonstrates that catheter-to-vessel wall distances, measured from IVUS images, can be employed to compensate for inaccuracies caused by variable intravascular NIRF sensing distances.


Assuntos
Catéteres , Processamento de Imagem Assistida por Computador/métodos , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Ultrassonografia de Intervenção/instrumentação , Ultrassonografia de Intervenção/métodos , Algoritmos , Animais , Sangue/diagnóstico por imagem , Bovinos , Vasos Coronários/diagnóstico por imagem , Imagens de Fantasmas , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA