RESUMO
PURPOSE: Fatigue stress fractures are a common overuse injury, frequently associated with high load-bearing endurance activities such as running, military training and aerobic exercise. While these fractures can arise at any site, sacral stress fractures are poorly studied with evidence consisting mainly of case reports and limited case series. This review aims to analyze and summarize all reports published to date describing cases of sacral stress fracture in athletes. METHODS: PubMed, Embase, Web of Science and the Cochrane Database were systematically searched for studies reporting on Stress Fractures of the Sacrum. Insufficiency fractures of the elderly were excluded. RESULTS: The literature review revealed 49 studies reporting on 124 cases of sacral stress fractures. Seventy-six patients (61%) were professional or collegiate level athletes, and 37 (30%) were military recruits or police officers in training. Seventeen female athletes were identified as suffering from low bone mineral density (25%), 9 of which reported menstrual irregularities. Thirteen female patients (19%) had a history of eating disorders. CONCLUSION: While most sacral stress fractures occur in normal bones exposed to abnormal repetitive loads, the high percentage of lower bone mineral density can blur the lines between fatigue fractures and insufficiency fractures. The causes of these fractures are multifactorial. High endurance sports and the features of the female athlete triad were found in high percentage of the cases. Conservative treatment is the mainstay of treatment, consisting of ceasing of training and a period of rehabilitation and gradual return to training and competition.
Assuntos
Fraturas de Estresse , Corrida , Fraturas da Coluna Vertebral , Atletas , Feminino , Fraturas de Estresse/epidemiologia , Fraturas de Estresse/etiologia , Humanos , Corrida/lesões , Sacro/lesões , Fraturas da Coluna Vertebral/complicaçõesRESUMO
BACKGROUND: Failure to accurately replicate the native anatomy and biomechanics of the knee has been suggested to contribute to dissatisfaction after TKA. Custom implants promise a personalized surgical approach, with the aim of improving patient satisfaction and pain as well as lowering revision rates. However, some published research on custom TKA implants has found no clinically important improvements in postoperative validated outcomes scores, risks of revision or reoperation, and implant alignment. In the interest of helping to settle this controversy, a systematic review seems warranted. QUESTION/PURPOSE: In this systematic review, we asked whether custom implants result in clinically important improvements over conventional off-the-shelf implants for anatomically uncomplicated primary TKA in terms of (1) validated outcomes scores, (2) the risk of revision or reoperation, and (3) implant alignment. METHODS: The US National Library of Medicine (PubMed/Medline), Embase, Web of Science, and Cochrane Database of Systematic Reviews were systematically searched to identify publications from the past 10 years relevant to this review. Publications that compared the clinical outcome measures, number of revisions and reoperations, and radiological assessment of implant alignment of custom and standard implants with validated endpoints were eligible for inclusion. In the interest of capturing as much potentially relevant information as possible, we applied no requirement for minimum follow-up duration. Clinical outcomes were assessed using patient-reported outcome (PROM) scores including the Knee Society Score (KSS), Forgotten Joint Score, and Knee Injury and Osteoarthritis Outcome Score. The risk for revision or reoperation were evaluated by the number of early and late manipulations, debridement procedures, and replacement of one or more components. Implant alignment was compared using postoperative deviation from the neutral (0°) mechanical axis of the limb and each component and the posterior tibial slope. All qualified studies were retrospective, and all compared custom implants with standard implants. Data on 1510 patients were reviewed (749 with custom implants and 761 with off-the-shelf implants). The mean follow-up time ranged from 12 to 33 months. RESULTS: There was no apparent advantage to custom implants in terms of PROM scores. Of the five studies evaluating clinical outcomes, only one reported better KSS-Function scores at 3 months; two reported no difference, and two found inferior KSS scores. In several studies, custom implants were associated with more frequent reoperations than standard implants. Although in general there were no differences between custom and standard implants in terms of mean coronal plane limb alignment, one of seven studies found that the proportion of patients whose alignment was outside ± 3° from the neutral axis in the coronal plane was lower in the custom group than in the standard group. CONCLUSION: With generally poorer outcomes scores for pain and function, generally higher risks of reoperation and reintervention, and no overall benefit to alignment, custom implants for primary TKA for the general population currently appear to be inferior to standard implants. Whether the slight reduction in the proportion of patients with alignment outliers observed in a minority of studies will result in a substantial reduction in revision risk over time must be addressed by future studies. However, until or unless such a reduction is proven, we recommend against the routine use of custom implants in practice because of increased costs and the risks associated with their novelty. LEVEL OF EVIDENCE: Level III, therapeutic study.