Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(15)2024 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-39123940

RESUMO

Physical therapy is often essential for complete recovery after injury. However, a significant population of patients fail to adhere to prescribed exercise regimens. Lack of motivation and inconsistent in-person visits to physical therapy are major contributing factors to suboptimal exercise adherence, slowing the recovery process. With the advancement of virtual reality (VR), researchers have developed remote virtual rehabilitation systems with sensors such as inertial measurement units. A functional garment with an integrated wearable sensor can also be used for real-time sensory feedback in VR-based therapeutic exercise and offers affordable remote rehabilitation to patients. Sensors integrated into wearable garments offer the potential for a quantitative range of motion measurements during VR rehabilitation. In this research, we developed and validated a carbon nanocomposite-coated knit fabric-based sensor worn on a compression sleeve that can be integrated with upper-extremity virtual rehabilitation systems. The sensor was created by coating a commercially available weft knitted fabric consisting of polyester, nylon, and elastane fibers. A thin carbon nanotube composite coating applied to the fibers makes the fabric electrically conductive and functions as a piezoresistive sensor. The nanocomposite sensor, which is soft to the touch and breathable, demonstrated high sensitivity to stretching deformations, with an average gauge factor of ~35 in the warp direction of the fabric sensor. Multiple tests are performed with a Kinarm end point robot to validate the sensor for repeatable response with a change in elbow joint angle. A task was also created in a VR environment and replicated by the Kinarm. The wearable sensor can measure the change in elbow angle with more than 90% accuracy while performing these tasks, and the sensor shows a proportional resistance change with varying joint angles while performing different exercises. The potential use of wearable sensors in at-home virtual therapy/exercise was demonstrated using a Meta Quest 2 VR system with a virtual exercise program to show the potential for at-home measurements.


Assuntos
Articulação do Cotovelo , Nanocompostos , Realidade Virtual , Dispositivos Eletrônicos Vestíveis , Humanos , Nanocompostos/química , Articulação do Cotovelo/fisiologia , Robótica/instrumentação , Nanotubos de Carbono/química , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Amplitude de Movimento Articular/fisiologia , Carbono/química
2.
J Clin Med ; 13(8)2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38673591

RESUMO

Background: Concomitant atrial fibrillation (AF) is associated with an adverse prognosis in patients with acute myocardial infarction (MI). However, it remains unclear whether this is due to a causal effect of AF or whether AF acts as a surrogate marker for comorbidities in this population. Furthermore, there are limited data on whether coronary artery disease distribution impacts the risk of developing AF. Methods: Consecutive patients admitted with acute MI and treated using percutaneous coronary intervention (PCI) at a single centre were retrospectively identified. Associations between AF and major adverse cardiac and cerebrovascular events (MACCEs) over a median of five years of follow-up were assessed using Cox regression, with adjustment for confounding factors performed using both multivariable modelling and a propensity-score-matched analysis. Results: AF was identified in N = 65/1000 (6.5%) of cases; these patients were significantly older (mean: 73 vs. 65 years, p < 0.001), with lower creatinine clearance (p < 0.001), and were more likely to have a history of cerebrovascular disease (p = 0.011) than those without AF. In addition, patients with AF had a greater propensity for left main stem (p = 0.001) or left circumflex artery (p = 0.004) involvement. Long-term MACCE rates were significantly higher in the AF group than in the non-AF group (50.8% vs. 34.2% at five years), yielding an unadjusted hazard ratio (HR) of 1.86 (95% CI: 1.32-2.64, p < 0.001). However, after adjustment for confounding factors, AF was no longer independently associated with MACCEs, either on multivariable (adjusted HR: 1.25, 95% CI: 0.81-1.92, p = 0.319) or propensity-score-matched (HR: 1.04, 95% CI: 0.59-1.82, p = 0.886) analyses. Conclusions: AF is observed in 6.5% of patients admitted with acute MI, and those with AF are more likely to have significant diseases involving left main or circumflex arteries. Although unadjusted MACCE rates were significantly higher in patients with AF, this effect was not found to remain significant after adjustment for comorbidities. As such, this study provided no evidence to suggest that AF is independently associated with MACCEs.

3.
ACS Appl Mater Interfaces ; 16(2): 2692-2703, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38173339

RESUMO

As the need for high-speed electronics continues to rise rapidly, printed wiring board (PWB) requirements become ever-more demanding. A typical PWB is fabricated by bonding dielectric films such as polyimide to electrically conductive copper foil such as rolled annealed (RA) copper and is expected to become thinner, flexible, durable, and compatible with high-frequency 5G performance. Polyimide films inherently feature a higher coefficient of thermal expansion (CTE) than copper foils; this mismatch causes residual thermal stresses. To attenuate the mismatch, silica nanoparticles may be used to reduce the CTE of PI. A nodulated copper surface can be used to enhance the Cu/PI adhesion by additional bonding mechanisms that could include a type of mechanical bonding, which is a focus of this study. In this investigation, a 90° peel test was used to measure the peel strength in copper/polyimide/copper laminates containing nodulated copper and polyimide reinforced with 0, 20, and 40 wt % silica nanoparticles. The influence of silica nanoparticles on the peel strength was quantitatively evaluated. Laminates incorporating polyimide films lacking silica nanoparticles had a ∼3.75× higher peel strength compared with laminates reinforced with 40% silica. Their failure surfaces were analyzed by using scanning electron microscopy (SEM), energy-dispersive X-ray analysis (EDX), and X-ray photoelectron spectroscopy to identify the mode of failure and to understand bonding mechanisms. The key bonding mechanism, mechanical interlocking, was achieved when the polyimide surrounded or engulfed the copper nodules when the laminate was created. Post-testing failure surface analysis revealed the presence of copper on the polyimide side and polyimide on the copper side, indicating mixed mode failure. An analytical model was developed to determine the impact of applied pressure, temperature, and time on the polyimide penetration and mechanical interlocking around the copper nodules. The model was validated by measuring the peel strength on another set of specimens fabricated using increased temperature and pressure that showed a 3× increase in peel strength compared to lower temperature/pressure processing conditions. This enhanced adhesion resulted from the lower polymer material viscosity at higher temperatures, which fosters deeper and more complete penetration around the copper nodules during processing at higher pressures for longer durations. The methodology of combining peel testing, viscosity and CTE measurement, SEM/EDX, surface chemical analysis, and penetration depth calculation developed herein enables the calculation of the desired processing parameters to enhance functionality and improve adhesion.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA