1.
Phys Med Biol ; 69(1)2023 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-38041870

RESUMO

Objective. X-ray spectral computed tomography (CT) allows for material decomposition (MD). This study compared a one-step material decomposition MD algorithm with a two-step reconstruction MD algorithm using acquisitions of a prototype CT scanner with a photon-counting detector (PCD).Approach. MD and CT reconstruction may be done in two successive steps, i.e. decompose the data in material sinograms which are then reconstructed in material CT images, or jointly in a one-step algorithm. The one-step algorithm reconstructed material CT images by maximizing their Poisson log-likelihood in the projection domain with a spatial regularization in the image domain. The two-step algorithm maximized first the Poisson log-likelihood without regularization to decompose the data in material sinograms. These sinograms were then reconstructed into material CT images by least squares minimization, with the same spatial regularization as the one step algorithm. A phantom simulating the CT angiography clinical task was scanned and the data used to measure noise and spatial resolution properties. Low dose carotid CT angiographies of 4 patients were also reconstructed with both algorithms and analyzed by a radiologist. The image quality and diagnostic clinical task were evaluated with a clinical score.Main results. The phantom data processing demonstrated that the one-step algorithm had a better spatial resolution at the same noise level or a decreased noise value at matching spatial resolution. Regularization parameters leading to a fair comparison were selected for the patient data reconstruction. On the patient images, the one-step images received higher scores compared to the two-step algorithm for image quality and diagnostic.Significance. Both phantom and patient data demonstrated how a one-step algorithm improves spectral CT image quality over the implemented two-step algorithm but requires a longer computation time. At a low radiation dose, the one-step algorithm presented good to excellent clinical scores for all the spectral CT images.


Assuntos
Melhoria de Qualidade , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Tomógrafos Computadorizados , Algoritmos , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador/métodos
3.
Radiology ; 309(1): e222432, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37787672

RESUMO

CT systems equipped with photon-counting detectors (PCDs), referred to as photon-counting CT (PCCT), are beginning to change imaging in several subspecialties, such as cardiac, vascular, thoracic, and musculoskeletal radiology. Evidence has been building in the literature underpinning the many advantages of PCCT for different clinical applications. These benefits derive from the distinct features of PCDs, which are made of semiconductor materials capable of converting photons directly into electric signal. PCCT advancements include, among the most important, improved spatial resolution, noise reduction, and spectral properties. PCCT spatial resolution on the order of 0.25 mm allows for the improved visualization of small structures (eg, small vessels, arterial walls, distal bronchi, and bone trabeculations) and their pathologies, as well as the identification of previously undetectable anomalies. In addition, blooming artifacts from calcifications, stents, and other dense structures are reduced. The benefits of the spectral capabilities of PCCT are broad and include reducing radiation and contrast material dose for patients. In addition, multiple types of information can be extracted from a single data set (ie, multiparametric imaging), including quantitative data often regarded as surrogates of functional information (eg, lung perfusion). PCCT also allows for a novel type of CT imaging, K-edge imaging. This technique, combined with new contrast materials specifically designed for this modality, opens the door to new applications for imaging in the future.


Assuntos
Artérias , Tomografia Computadorizada por Raios X , Humanos , Artefatos , Brônquios , Meios de Contraste
4.
Diagn Interv Imaging ; 104(10): 490-499, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37248095

RESUMO

PURPOSE: The purpose of this study was to investigate the feasibility of gadolinium-K-edge-angiography (angio-Gd-K-edge) with gadolinium-based contrast agents (GBCAs) as obtained with spectral photon counting CT (SPCCT) in atherosclerotic rabbits. MATERIALS AND METHODS: Seven atherosclerotic rabbits underwent angio-SPCCT acquisitions with two GBCAs, with similar intravenous injection protocol. Conventional and angio-Gd-K-edge images were reconstructed with the same parameters. Regions of interest were traced in different locations of the aorta and its branches. Hounsfield unit values, Gd concentrations, signal-to-noise (SNR) and contrast-to-noise (CNR) were calculated and compared. The maximum diameter and the diameter of the aorta in regard to atherosclerotic plaques were measured by two observers. Images were subjectively evaluated regarding vessels' enhancement, artefacts, border sharpness and overall image quality. RESULTS: In the analyzable six rabbits, Gd-K-edge allowed visualization of target vessels and no other structures. HU values and Gd concentrations were greatest in the largest artery (descending aorta, 5.6 ± 0.8 [SD] mm), and lowest in the smallest (renal arteries, 2.1 ± 0.3 mm). While greater for conventional images, CNR and SNR were satisfactory for both images (all P < 0.001). For one observer there were no statistically significant differences in either maximum or plaque-diameters (P = 0.45 and all P > 0.05 in post-hoc analysis, respectively). For the second observer, there were no significant differences for images reconstructed with the same parameters (all P < 0.05). All subjective criteria scored higher for conventional images compared to K-edge (all P < 0.01), with the highest scores for enhancement (4.3-4.4 vs. 3.1-3.4). CONCLUSION: With SPCCT, angio-Gd-K-edge after injection of GBCAs in atherosclerotic rabbits is feasible and allows for angiography-like visualization of small arteries and for the reliable measurement of their diameters.


Assuntos
Gadolínio , Tomografia Computadorizada por Raios X , Animais , Coelhos , Tomografia Computadorizada por Raios X/métodos , Angiografia , Meios de Contraste , Abdome
5.
Eur Radiol ; 33(8): 5476-5488, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36920517

RESUMO

OBJECTIVES: To evaluate the quality of virtual monochromatic images (VMIs) from spectral photon-counting CT (SPCCT) and two energy-integrating detector dual-energy CT (EID-DECT) scanners from the same manufacturer, for the coronary lumen. METHODS: A 21-cm section of the Mercury v4.0 phantom was scanned using a cardiac CT protocol. VMIs from 40 to 90 keV were reconstructed using high-resolution (HR) parameters for EID-DECT and SPCCT (CB and HRB kernels at 0.67 mm slice thickness, respectively). Ultra-high-resolution (UHR) parameters were used in addition to SPCCT (detailed-2 kernel, 0.43 mm slice thickness). Noise-power-spectrum (NPS), task-based transfer function (TTF), and detectability index (d') were computed for 2-mm-diameter lumen detection. In consensus, two radiologists analyzed the quality of the images from 8 patients who underwent coronary CTA on both CT systems. RESULTS: For all keV images, fpeak, f50, and d' were higher with SPCCT. The fpeak and f50 were higher with UHR-SPCCT with greater noise and lower d' compared to those of the HR-SPCCT images. Noise magnitude was constant for all energy levels (keV) with both systems, and lower with HR images, and d' decreased as keV decreased. Subjective analysis showed greater lumen sharpness and overall quality for HR and UHR-SPCCT images using all keV, with a greater difference at low keV compared to HR-EID-DECT images. CONCLUSION: HR and UHR-SPCCT images gave greater detectability of the coronary lumen for 40 to 90 keV VMIs compared to two EID-DECT systems, with benefits of higher lumen sharpness and overall quality. KEY POINTS: • Compared with 2 dual-energy CT systems, spectral photon-counting CT (SPCCT) improved spatial resolution, noise texture, noise magnitude, and detectability of the coronary lumen. • Use of ultra-high-resolution parameters with SPCCT improved spatial resolution and noise texture and provided high detectability of the coronary lumen, despite an increase in noise magnitude. • In eight patients, radiologists found greater overall image quality with SPCCT for all virtual monochromatic images with a greater difference at low keV, compared with dual-energy CT systems.


Assuntos
Vasos Coronários , Tomografia Computadorizada por Raios X , Humanos , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Coração , Fótons
6.
Invest Radiol ; 58(7): 459-471, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-36822663

RESUMO

ABSTRACT: Spectral photon-counting computed tomography (SPCCT) technology holds great promise for becoming the next generation of computed tomography (CT) systems. Its technical characteristics have many advantages over conventional CT imaging. For example, SPCCT provides better spatial resolution, greater dose efficiency for ultra-low-dose and low-dose protocols, and tissue contrast superior to that of conventional CT. In addition, SPCCT takes advantage of several known approaches in the field of spectral CT imaging, such as virtual monochromatic imaging and material decomposition imaging. In addition, SPCCT takes advantage of a new approach in this field, known as K-edge imaging, which allows specific and quantitative imaging of a heavy atom-based contrast agent. Hence, the high potential of SPCCT systems supports their ongoing investigation in clinical research settings. In this review, we propose an overview of our clinical research experience of a whole-body SPCCT clinical prototype, to give an insight into the potential benefits for clinical human imaging on image quality, diagnostic confidence, and new approaches in spectral CT imaging.


Assuntos
Fótons , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Tomógrafos Computadorizados
7.
Radiology ; 303(2): 303-313, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35166583

RESUMO

Background Spatial resolution, soft-tissue contrast, and dose-efficient capabilities of photon-counting CT (PCCT) potentially allow a better quality and diagnostic confidence of coronary CT angiography (CCTA) in comparison to conventional CT. Purpose To compare the quality of CCTA scans obtained with a clinical prototype PCCT system and an energy-integrating detector (EID) dual-layer CT (DLCT) system. Materials and Methods In this prospective board-approved study with informed consent, participants with coronary artery disease underwent retrospective electrocardiographically gated CCTA with both systems after injection of 65-75 mL of 400 mg/mL iodinated contrast agent at 5 mL/sec. A prior phantom task-based quality assessment of the detectability index of coronary lesions was performed. Ultra-high-resolution parameters were used for PCCT (1024 matrix, 0.25-mm section thickness) and EID DLCT (512 matrix, 0.67-mm section thickness). Three cardiac radiologists independently performed a blinded analysis using a five-point quality score (1 = insufficient, 5 = excellent) for overall image quality, diagnostic confidence, and diagnostic quality of calcifications, stents, and noncalcified plaques. A logistic regression model, adjusted for radiologists, was used to evaluate the proportion of improvement in scores with the best method. Results Fourteen consecutive participants (12 men; mean age, 61 years ± 17) were enrolled. Scores of overall quality and diagnostic confidence were higher with PCCT images with a median of 5 (interquartile range [IQR], 2) and 5 (IQR, 1) versus 4 (IQR, 1) and 4 (IQR, 3) with EID DLCT images, using a mean tube current of 255 mAs ± 0 versus 349 mAs ± 111 for EID DLCT images (P < .01). Proportions of improvement with PCCT images for quality of calcification, stent, and noncalcified plaque were 100%, 92% (95% CI: 71, 98), and 45% (95% CI: 28, 63), respectively. In the phantom study, detectability indexes were 2.3-fold higher for lumen and 2.9-fold higher for noncalcified plaques with PCCT images. Conclusion Coronary CT angiography with a photon-counting CT system demonstrated in humans an improved image quality and diagnostic confidence compared with an energy-integrating dual-layer CT. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Sandfort and Bluemke in this issue.


Assuntos
Angiografia por Tomografia Computadorizada , Fótons , Angiografia por Tomografia Computadorizada/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
8.
Invest Radiol ; 57(4): 212-221, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-34711766

RESUMO

OBJECTIVES: The aim of this study is to compare the image quality of in vivo coronary stents between an energy integrating detectors dual-layer computed tomography (EID-DLCT) and a clinical prototype of spectral photon counting computed tomography (SPCCT). MATERIALS AND METHODS: In January to June 2021, consecutive patients with coronary stents were prospectively enrolled to undergo a coronary computed tomography (CT) with an EID-DLCT (IQon, Philips) and an SPCCT (Philips). The study was approved by the local ethical committee and patients signed an informed consent. A retrospectively electrocardiogram-gated acquisition was performed with optimized matching parameters on the 2 scanners (EID-DLCT: collimation, 64 × 0.625 mm; kVp, 120, automatic exposure control with target current at 255 mAs; rotation time, 0.27 seconds; SPCCT: collimation, 64 × 0.275 mm; kVp, 120; mAs, 255; rotation time, 0.33 seconds). The injection protocol was the same on both scanners: 65 to 75 mL of Iomeron (Bracco) at 5 mL/s. Images were reconstructed with slice thickness of 0.67 mm, 512 matrix, XCB (Xres cardiac standard) and XCD (Xres cardiac detailed) kernel, iDose 3 for EID-DLCT and 0.25-mm slice thickness, 1024 matrix, Detailed 2 and Sharp kernel, and iDose 6 for SPCCT. Two experienced observers measured the proximal and distal external and internal diameters of the stents to quantify blooming artifacts. Regions of interest were drawn in the lumen of the stent and of the upstream coronary artery. The difference (Δ S-C) between the respective attenuation values was calculated as a quantification of stent-induced artifacts on intrastent image quality. For subjective image quality, 3 experienced observers graded with a 4-point scale the image quality of different parameters: coronary wall before the stent, stent lumen, stent structure, calcifications surrounding the stent, and beam-hardening artifacts. RESULTS: Eight patients (age, 68 years [interquartile range, 8]; all men; body mass index, 26.2 kg/m2 [interquartile range, 4.2]) with 16 stents were scanned. Five stents were not evaluable owing to motion artifacts on the SPCCT. Of the remaining, all were drug eluting stents, of which 6 were platinum-chromium, 3 were cobalt-platinum-iridium, and 1 was stainless steel. For 1 stent, no information could be retrieved. Radiation dose was lower with the SPCCT (fixed CT dose index of 25.7 mGy for SPCCT vs median CT dose index of 35.7 [IQ = 13.6] mGy; P = 0.02). For 1 stent, the internal diameter was not assessable on EID-DLCT. External diameters were smaller and internal diameters were larger with SPCCT (all P < 0.05). Consequently, blooming artifacts were reduced on SPCCT (P < 0.05). Whereas Hounsfield unit values within the coronary arteries on the 2 scanners were similar, the Δ S-C was lower for SPCCT-Sharp as compared with EID-DLCT-XCD and SPCCT-Detailed 2 (P < 0.05). The SPCCT received higher subjective scores than EID-DLCT for stent lumen, stent structure, surrounding calcifications and beam-hardening for both Detailed 2 and Sharp (all P ≤ 0.05). The SPCCT-Sharp was judged better for stent structure and beam-hardening assessment as compared with SPCCT-Detailed 2. CONCLUSION: Spectral photon counting CT demonstrated improved objective and subjective image quality as compared with EID-DLCT for the evaluation of coronary stents even with a reduced radiation dose.


Assuntos
Angiografia por Tomografia Computadorizada , Platina , Idoso , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Humanos , Masculino , Imagens de Fantasmas , Fótons , Estudos Retrospectivos , Stents , Tomografia Computadorizada por Raios X/métodos
9.
Diagnostics (Basel) ; 11(12)2021 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-34943611

RESUMO

AIMS: To evaluate spectral photon-counting CT's (SPCCT) objective image quality characteristics in vitro, compared with standard-of-care energy-integrating-detector (EID) CT. METHODS: We scanned a thorax phantom with a coronary artery module at 10 mGy on a prototype SPCCT and a clinical dual-layer EID-CT under various conditions of simulated patient size (small, medium, and large). We used filtered back-projection with a soft-tissue kernel. We assessed noise and contrast-dependent spatial resolution with noise power spectra (NPS) and target transfer functions (TTF), respectively. Detectability indices (d') of simulated non-calcified and lipid-rich atherosclerotic plaques were computed using the non-pre-whitening with eye filter model observer. RESULTS: SPCCT provided lower noise magnitude (9-38% lower NPS amplitude) and higher noise frequency peaks (sharper noise texture). Furthermore, SPCCT provided consistently higher spatial resolution (30-33% better TTF10). In the detectability analysis, SPCCT outperformed EID-CT in all investigated conditions, providing superior d'. SPCCT reached almost perfect detectability (AUC ≈ 95%) for simulated 0.5-mm-thick non-calcified plaques (for large-sized patients), whereas EID-CT had lower d' (AUC ≈ 75%). For lipid-rich atherosclerotic plaques, SPCCT achieved 85% AUC vs. 77.5% with EID-CT. CONCLUSIONS: SPCCT outperformed EID-CT in detecting simulated coronary atherosclerosis and might enhance diagnostic accuracy by providing lower noise magnitude, markedly improved spatial resolution, and superior lipid core detectability.

11.
Radiology ; 300(1): 98-107, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33944628

RESUMO

Background Macrophage burden is a major factor in the risk of atherosclerotic plaque rupture, and its evaluation remains challenging with molecular noninvasive imaging approaches. Photon-counting CT (PCCT) with k-edge imaging aims to allow for the specific detection of macrophages using gold nanoparticles. Purpose To perform k-edge imaging in combination with gold nanoparticles to detect and quantify the macrophage burden within the atherosclerotic aortas of rabbits. Materials and Methods Atherosclerotic and control New Zealand white rabbits were imaged before and at several time points up to 2 days after intravenous injection of gold nanoparticles (3.5 mL/kg, 65 mg gold per milliliter). Aortic CT angiography was performed at the end of the follow-up using an intravenous injection of an iodinated contrast material. Gold k-edge and conventional CT images were reconstructed for qualitative and quantitative assessment of the macrophage burden. PCCT imaging results were compared with findings at histologic examination, quantitative histomorphometry, transmission electron microscopy, and quantitative inductively coupled plasma optical emission spectrometry. Pearson correlations between the macrophage area measured in immunostained sections and the concentration of gold and attenuation measured in the corresponding PCCT sections were calculated. Results Seven rabbits with atherosclerosis and four control rabbits without atherosclerosis were analyzed. In atherosclerotic rabbits, calcifications were observed along the aortic wall before injection. At 2 days after injection of gold nanoparticles, only gold k-edge images allowed for the distinction of plaque enhancement within calcifications and for lumen enhancement during angiography. A good correlation was observed between the gold concentration measured within the wall and the macrophage area in 35 plaques (five per rabbit) (r = 0.82; 95% CI: 0.67, 0.91; P < .001), which was higher than that observed on conventional CT images (r = 0.41; 95% CI: 0.09, 0.65; P = .01). Transmission electron microscopy and inductively coupled plasma optical emission spectrometry analyses confirmed the gold k-edge imaging findings. Conclusion Photon-counting CT with gold nanoparticles allowed for the noninvasive evaluation of both molecular and anatomic information in vivo in rabbits with atherosclerotic plaques. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Leiner in this issue.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Placa Aterosclerótica/diagnóstico por imagem , Animais , Aorta/diagnóstico por imagem , Modelos Animais de Doenças , Ouro , Macrófagos , Nanopartículas Metálicas , Fótons , Coelhos
12.
Eur Radiol ; 31(9): 7132-7142, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33740093

RESUMO

OBJECTIVES: To quantitatively evaluate the impact of virtual monochromatic images (VMI) on reduced-iodine-dose dual-energy coronary computed tomography angiography (CCTA) in terms of coronary lumen segmentation in vitro, and secondly to assess the image quality in vivo, compared with conventional CT obtained with regular iodine dose. MATERIALS AND METHODS: A phantom simulating regular and reduced iodine injection was used to determine the accuracy and precision of lumen area segmentation for various VMI energy levels. We retrospectively included 203 patients from December 2017 to August 2018 (mean age, 51.7 ± 16.8 years) who underwent CCTA using either standard (group A, n = 103) or reduced (group B, n = 100) iodine doses. Conventional images (group A) were qualitatively and quantitatively compared with 55-keV VMI (group B). We recorded the location of venous catheters. RESULTS: In vitro, VMI outperformed conventional CT, with a segmentation accuracy of 0.998 vs. 1.684 mm2, respectively (p < 0.001), and a precision of 0.982 vs. 1.229 mm2, respectively (p < 0.001), in simulated overweight adult subjects. In vivo, the rate of diagnostic CCTA in groups A and B was 88.4% (n = 91/103) vs. 89% (n = 89/100), respectively, and noninferiority of protocol B was inferred. Contrast-to-noise ratios (CNR) of lumen versus fat and muscle were higher in group B (p < 0.001) and comparable for lumen versus calcium (p = 0.423). Venous catheters were more often placed on the forearm or hand in group B (p < 0.001). CONCLUSION: In vitro, low-keV VMI improve vessel area segmentation. In vivo, low-keV VMI allows for a 40% iodine dose and injection rate reduction while maintaining diagnostic image quality and improves the CNR between lumen versus fat and muscle. KEY POINTS: • Dual-energy coronary CT angiography is becoming increasingly available and might help improve patient management. • Compared with regular-iodine-dose coronary CT angiography, reduced-iodine-dose dual-energy CT with low-keV monochromatic image reconstructions performed better in phantom-based vessel cross-sectional segmentation and proved to be noninferior in vivo. • Patients receiving reduced-iodine-dose dual-energy coronary CT angiography often had the venous catheter placed on the forearm or wrist without compromising image quality.


Assuntos
Iodo , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Adulto , Idoso , Angiografia por Tomografia Computadorizada , Meios de Contraste , Relação Dose-Resposta a Droga , Humanos , Iodo/administração & dosagem , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X
13.
Eur Radiol ; 30(1): 425-431, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31332557

RESUMO

OBJECTIVES: To assess the capability of a newly developed material decomposition method from contrast-enhanced dual-energy CT images, aiming to better visualize the aortic wall and aortic intramural hematoma (IMH), compared with true non-contrast (TNC) CT. MATERIALS AND METHODS: Twenty-two patients (11 women; mean age, 61 ± 20 years) with acute chest pain underwent 25 dual-layer non-contrast and contrast-enhanced CT. CT-angiography images were retrospectively processed using two-material decomposition analysis, where we defined the first material as the content of a region of interest placed in the ascending aorta for each patient, and the second material as water. Two independent radiologists assessed the images from the second material termed "dark-blood" images and the TNC images regarding contrast-to-noise ratio (CNR) between the wall and the lumen, diagnostic quality regarding the presence of aortic wall thickening, and the inner/outer vessel wall conspicuity. RESULTS: Diagnostic quality scores in normal aortic segments were 0.9 ± 0.3 and 2.7 ± 0.6 (p < 0.001) and wall conspicuity scores were 0.7 ± 0.5 and 1.8 ± 0.3 (p < 0.001) on TNC and dark-blood images, respectively. In aortic segments with IMH, diagnostic quality scores were 1.7 ± 0.5 and 2.4 ± 0.6 (p < 0.001) and wall conspicuity scores were 0.7 ± 0.7 and 1.8 ± 0.3 (p < 0.001) on TNC and dark-blood images, respectively. In normal aortic segments, CNRs were 0.3 ± 0.2 and 2.8 ± 0.9 on TNC and dark-blood images, respectively (p < 0.001). In aortic segments with IMH, CNRs were 0.3 ± 0.2 and 4.0 ± 1.0 on TNC and dark-blood images, respectively (p < 0.001). CONCLUSIONS: Compared with true non-contrast CT, dark-blood material decomposition maps enhance quantitative and qualitative image quality for the assessment of normal aortic wall and IMH. KEY POINTS: • Current dual-energy CT-angiography provides virtual non-contrast and bright-blood images. • Dark-blood images represent a new way to assess the vascular wall structure with dual-energy CT and can improve the lumen-to-wall contrast compared with true non-contrast CT. • This dual-energy CT material decomposition method is likely to improve contrast resolution in other applications as well, taking advantage of the high spatial resolution of CT.


Assuntos
Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Hematoma/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
14.
Eur Radiol ; 28(8): 3355-3361, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29468341

RESUMO

OBJECTIVES: Endovascular renal denervation (RDN) using catheter-based radiofrequency (RF) ablation has emerged as a potential treatment option for drug-resistant hypertension. Its efficacy is currently under debate. We aimed to evaluate the capability of contrast-enhanced magnetic resonance imaging (MRI) to assess the effects of RDN on the renal arterial wall in patients presenting with drug-resistant hypertension. METHODS: Patients were included prospectively following institutional review board approval and written informed consent. Renal arteries were imaged using a two-dimensional T1-weighted TSE sequence pre- and post-administration of a gadolinium-based contrast agent, before (D0), 2 days (D2) and 6 months (M6) after RDN. Mean enhancement of the wall (mENH) and mean wall thickness (mWT) were compared across time using an ANOVA with repeated measures and post-hoc paired t-test. RESULTS: Follow-up was completed for 23 patients (median age, 57 years; 16 men). The mENH at D2 (96.3 ± 36.0 %) was significantly higher than at D0 (61.1 ± 26.3%, p < 0.001) and M6 (66.1±22.7%, p < 0.001). Similarly, mWT was significantly higher at D2 (3.1 ± 0.4 m) than at D0 (2.7 ± 0.4mm, p < 0.001) and M6 (2.9 ± 0. 5 mm, p = 0.002). CONCLUSIONS: MRI demonstrated abnormalities of the arterial wall 2 days after RDN that had resolved at 6 months. KEY POINTS: • Contrast-enhanced MRI provides anatomic evidence of renal artery RF ablation • Temperature increase related to RF ablation induces transient arterial wall inflammation • Morphological effects observed 2 days post RF ablation are not visible after 6 months.


Assuntos
Ablação por Cateter/efeitos adversos , Hipertensão/cirurgia , Complicações Intraoperatórias/diagnóstico , Artéria Renal/lesões , Simpatectomia/efeitos adversos , Idoso , Análise de Variância , Anti-Hipertensivos/uso terapêutico , Ablação por Cateter/métodos , Resistência a Medicamentos , Feminino , Humanos , Hipertensão/tratamento farmacológico , Hipertensão/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Simpatectomia/métodos
15.
J Vasc Surg ; 57(4): 1046-1051.e2, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23375613

RESUMO

OBJECTIVE: Carotid magnetic resonance imaging (MRI) may be a useful tool in characterizing carotid plaque vulnerability, but large studies are still lacking. The purpose of this study was to assess carotid MRI features of vulnerable plaque in a large study and the changes in carotid plaque morphology with respect to time since the neurological event. METHODS: We included 161 patients with carotid plaque more than 3 mm thick. All patients underwent carotid MRI to obtain 3-T high-resolution magnetic resonance sequences. Large lipid core, intraplaque hemorrhage (IPH), fibrous cap rupture (FCR), and gadolinium enhancement (GE) were assessed and classified as present or absent. Prevalences of these features were then compared between symptomatic and asymptomatic patients and time since stroke. RESULTS: Seven patients were excluded because of poor image quality. Of the remaining 154 patients, 52 were symptomatic and 102 were asymptomatic. The prevalences of IPH (39 vs 16%; P = .002), FCR (30 vs 9%; P = .001), and GE (75 vs 55%; P = .015) were significantly higher in symptomatic than asymptomatic patients. After multivariate analysis, the prevalences of IPH (odds ratio, 2.6; P = .023) and FCR (odds ratio, 2.8; P = .038) were still significantly higher. The prevalence of IPH was significantly higher in symptomatic patients with plaque regardless of the time since the neurological event. For FCR, the difference between symptomatic and asymptomatic patients was significant only during the first 15 days after the neurological event. CONCLUSIONS: Carotid MRI can identify plaque features that are associated with symptomatic presentation and may be indicative of plaque vulnerability. These features may ultimately be used in the management of extracranial carotid stenosis.


Assuntos
Artérias Carótidas/patologia , Doenças das Artérias Carótidas/diagnóstico , Angiografia por Ressonância Magnética , Placa Aterosclerótica , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Assintomáticas , Artérias Carótidas/química , Doenças das Artérias Carótidas/complicações , Doenças das Artérias Carótidas/metabolismo , Doenças das Artérias Carótidas/patologia , Distribuição de Qui-Quadrado , Meios de Contraste , Feminino , Fibrose , Hemorragia/patologia , Humanos , Ataque Isquêmico Transitório/etiologia , Lipídeos/análise , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Valor Preditivo dos Testes , Prognóstico , Ruptura Espontânea , Acidente Vascular Cerebral/etiologia , Fatores de Tempo
16.
Radiology ; 258(1): 206-12, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21062925

RESUMO

PURPOSE: To assess the potential of a single-session multidetector computed tomography (CT) protocol, as compared with established methods, for the etiologic work-up of acute ischemic stroke. MATERIALS AND METHODS: Patients found to have recently experienced an ischemic stroke were recruited for this prospective study after institutional review board approval was obtained. Each patient was scheduled for two evaluation strategies: (a) a standard approach involving transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE), duplex ultrasonography (US) of the neck vessels, and magnetic resonance (MR) angiography of the neck and brain vessels; and (b) a protocol involving single-session multidetector CT of the heart, neck, and brain vessels. The authors sought to determine the major etiologic factors of stroke, including cardiac sources of embolism and atheroma of the aortic arch and the extra- and intracranial vessels, by using both strategies. RESULTS: Multidetector CT, MR imaging, and duplex US were performed in 46 patients, 39 of whom also underwent TEE. The sensitivity and specificity of multidetector CT were 72% (18 of 25 cases) and 95% (20 of 21 cases), respectively, for detection of cardiac sources and 100% (24 of 24 cases) and 91% (20 of 22 cases), respectively, for detection of major arterial atheroma. For the 46 cases of stroke, the final etiologic classifications determined by using the standard combination approach were cardiac sources in 20 (44%) cases, major arterial atheroma in nine (20%), multiple sources in four (9%), and cryptogenic sources in 13 (28%). Multidetector CT facilitated correct etiologic classification for 38 (83%) of the 46 patients. CONCLUSION: Multidetector CT is a promising tool for etiologic assessment of ischemic stroke, although the identification of minor cardiac sources with this examination requires the establishment of robust criteria.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/etiologia , Artérias Cerebrais/diagnóstico por imagem , Artérias Cerebrais/patologia , Circulação Cerebrovascular , Meios de Contraste , Trombose Coronária/complicações , Trombose Coronária/diagnóstico , Ecocardiografia/métodos , Eletrocardiografia , Feminino , Humanos , Iopamidol/análogos & derivados , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Placa Aterosclerótica/complicações , Placa Aterosclerótica/diagnóstico , Estudos Prospectivos , Fatores de Risco , Sensibilidade e Especificidade , Estatísticas não Paramétricas , Acidente Vascular Cerebral/etiologia , Ultrassonografia Doppler Dupla
17.
Radiology ; 252(2): 401-9, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19703881

RESUMO

PURPOSE: To evaluate the use of a recently developed fast-clearing ultrasmall superparamagnetic iron oxide (USPIO) for detection of vascular inflammation in atherosclerotic plaque. MATERIALS AND METHODS: The study protocol was approved by the animal experimentation ethics committee. A recently introduced USPIO, P904, and a reference-standard USPIO, ferumoxtran-10, were tested in a rabbit model of induced aortic atherosclerosis. In vivo magnetic resonance (MR) angiography and T2*-weighted plaque MR imaging were performed at baseline and after administration of P904 and ferumoxtran-10 (administered dose for both, 1000 micromol of iron per kilogram of body weight) in 26 hyperlipidemic New Zealand white rabbits. The variation in vessel wall area over time was evaluated with nonparametric testing. Ex vivo MR imaging findings were compared with iron content at linear regression analysis. RESULTS: With in vivo MR imaging, plaque analysis was possible as early as 24 hours after P904 injection. The authors observed a 27.75% increase in vessel wall area due to susceptibility artifacts on day 2 (P = .04) and a 38.81% increase on day 3 (P = .04) after P904 administration compared with a 44.5% increase in vessel wall area on day 7 (P = .04) and a 34.8% increase on day 10 (P = .22) after ferumoxtran-10 administration. These susceptibility artifacts were correlated with intraplaque iron uptake in the corresponding histologic slices. The number of pixels with signal loss on the ex vivo MR images was linearly correlated with the logarithm of the iron concentration (P = .0001; R(2) = 0.93). CONCLUSION: Plaque inflammation in rabbits can be detected earlier with P904 than with ferumoxtran-10 owing to the faster blood pharmacokinetics and the early uptake of P904 in the reticuloendothelial system. SUPPLEMENTAL MATERIAL: http://radiology.rsnajnls.org/cgi/content/full/252/2/401/DC1.


Assuntos
Aortite/metabolismo , Aortite/patologia , Aterosclerose/metabolismo , Aterosclerose/patologia , Ferro/farmacocinética , Angiografia por Ressonância Magnética/métodos , Óxidos/farmacocinética , Animais , Meios de Contraste/farmacocinética , Dextranos , Modelos Animais de Doenças , Óxido Ferroso-Férrico , Humanos , Nanopartículas de Magnetita , Taxa de Depuração Metabólica , Projetos Piloto , Coelhos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Radiology ; 247(1): 273-85, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18372471

RESUMO

PURPOSE: To prospectively determine diagnostic performance and safety of contrast material-enhanced (CE) magnetic resonance (MR) angiography with 0.1 mmol per kilogram of body weight gadobenate dimeglumine for depiction of significant steno-occlusive disease (> or =51% stenosis) of renal arteries, with digital subtraction angiography (DSA) as reference standard. MATERIALS AND METHODS: This multicenter study was approved by local institutional review boards; all patients provided written informed consent. Patient enrollment and examination at centers in the United States complied with HIPAA. Two hundred ninety-three patients (154 men, 139 women; mean age, 61.0 years) with severe hypertension (82.2%), progressive renal failure (11.3%), and suspected renal artery stenosis (6.5%) underwent CE MR angiography with three-dimensional spoiled gradient-echo sequences after administration of 0.1 mmol/kg gadobenate dimeglumine at 2 mL/sec. Anteroposterior and oblique DSA was performed in 268 (91.5%) patients. Three independent blinded reviewers evaluated CE MR angiographic images. Sensitivity, specificity, and accuracy of CE MR angiography for detection of significant steno-occlusive disease (> or =51% vessel lumen narrowing) were determined at segment (main renal artery) and patient levels. Positive and negative predictive values and positive and negative likelihood ratios were determined. Interobserver agreement was analyzed with generalized kappa statistics. A safety evaluation (clinical examination, electrocardiogram, blood and urine analysis, monitoring for adverse events) was performed. RESULTS: Of 268 patients, 178 who were evaluated with MR angiography and DSA had significant steno-occlusive disease of renal arteries at DSA. Sensitivity, specificity, and accuracy of CE MR angiography for detection of 51% or greater stenosis or occlusion were 60.1%-84.1%, 89.4%-94.7%, and 80.4%-86.9%, respectively, at segment level. Similar values were obtained for predictive values and for patient-level analyses. Few CE MR angiographic examinations (1.9%-2.8%) were technically inadequate. Interobserver agreement for detection of significant steno-occlusive disease was good (79.9% agreement; kappa = 0.69). No safety concerns were noted. CONCLUSION: CE MR angiography performed with 0.1 mmol/kg gadobenate dimeglumine, compared with DSA, is safe and provides good sensitivity, specificity, and accuracy for detection of significant renal artery steno-occlusive disease.


Assuntos
Angiografia Digital , Meios de Contraste , Angiografia por Ressonância Magnética , Meglumina/análogos & derivados , Compostos Organometálicos , Obstrução da Artéria Renal/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Artéria Renal/diagnóstico por imagem , Artéria Renal/patologia , Obstrução da Artéria Renal/diagnóstico por imagem , Sensibilidade e Especificidade
19.
Eur Radiol ; 15 Suppl 5: E17-23, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18637227

RESUMO

Magnetic resonance angiography (MRA) is a cost effective technique able to detect and quantify stenoses, provide sub-millimeter resolution with full arterial coverage, and show true vessel delineation without artifacts.The quality of images obtained with gadolinium-enhanced MRA depends on the gradient system, coil, sequence design, and contrast agent (volume, dose and injection rate). MRA protocols are evolving from standard k-space sampling (linear from the periphery or the center) to elliptic centric view ordering and to time-resolved MRA. Finally, the gadolinium-based contrast agent Gd-BOPTA (gadobenate dimeglumine, MultiHance; Bracco Imaging, Milan, Italy) offers considerably greater imaging efficacy compared to conventional gadolinium chelates,because identical results can be obtained at lower doses. In conclusion, MRA of the peripheral vasculature is a simple and fast technique, which permits evaluation of a large field of view without risk of radiation exposure.