RESUMO
An older woman developed dyspnea after instrumented lumbar spinal fusion surgery. During clinical work-up, a chest radiography revealed a U-shaped object within the cardiac silhouette. Further imaging confirmed that the object was entrapped in the tricuspid subvalvular apparatus. Surgery was performed for removal of the object, which was later identified as cement (polymethyl methacrylate). Cement extravasation and embolism are well-known but rarely clinically significant complications after spinal surgery.
RESUMO
Cardiac implantable electronic devices (CIEDs) are essential tools in cardiology for tackling rhythm disturbances and have come a long way over the last decades. Technology is shifting toward leadless devices that spare the complications and limitations of traditional intravascular CIEDs. Herein, we report the simultaneous implantation of a leadless pacemaker (LP) and a subcutaneous implantable cardioverter-defibrillator (S-ICD) in two patients with hypertrophic cardiomyopathy, as well as their 2-year follow-up results, while explaining the preventive measures taken to steer around unwanted device interaction. Implantation of an S-ICD with an LP is reserved for unique cases but is a feasible approach when there is a contraindication for intravascular CIED implantation. Furthermore, this technique may be used in younger patients with cardiomyopathies in whom multiple generator replacements are expected, along with their known adverse effects.
RESUMO
PURPOSE: Syncope remains a common medical problem. Recently, the role of dedicated syncope units and implantable loop recorders has emerged in the investigation of unexplained syncope. This study aims to investigate the possibilities for a more rational and targeted use of various diagnostic tools. METHODS: In this retrospective single-center study, 196 patients with unexplained syncope were included between March 2019 and February 2023. Various diagnostic tools were utilized during the investigation, according to clinical judgement. Patients were retrospectively allocated into Group A (including those who, among other tests, underwent loop recorder insertion) and Group B (including patients investigated without loop recorder implantation). Data were compared with Group C, including patients assessed prior to syncope unit establishment. RESULTS: There was no difference between Group A (n = 133) and Group B (n = 63) in the diagnostic yield (74% vs. 76%, p = 0.22). There were significant differences between Groups A and B regarding age (67.3 ± 16.9 years vs. 48.3 ± 19.1 years, p < 0.001) and cause of syncope (cardiogenic in 69% of Group A, reflex syncope in 77% of Group B, p < 0.001). Electrocardiography-based diagnosis occurred in 55% and 19% of Groups A and B, respectively (p < 0.001). The time to diagnosis was 4.2 ± 2.7 months in Group A and 7.5 ± 5.6 months in Group B (p < 0.001). In Group C, the diagnostic yield was 57.9% and the electrocardiography-based diagnostic yield was 18.3%. CONCLUSIONS: A selective use of loop recorders according to clinical and electrocardiographic characteristics increases the effectiveness of the structured syncope unit approach and further preserves financial resources.
RESUMO
Testing for myocardial ischemia in patients presenting with sustained monomorphic Ventricular Tachycardia(VT) even without evidence of acute myocardial infarction is a tempting strategy that is frequently utilized in clinical practice. Monomorphic VT is mainly caused by re-entry around chronic myocardial scar and active ischemia has no role in its pathogenesis, thus making testing for ischemia futile, at least in theory. This systematic literature review sought to address the usefulness of ischemia testing (mainly coronary angiography) in patients presenting with monomorphic VT through 8 selected studies after evaluating a total of 130 published manuscripts. Particularly, we sought to unveil whether coronary angiography and possibly concomitant revascularization leads to lesser tachycardia recurrence. Our conclusion can be summarized as follows: this approach whether combined with revascularization or not, does not seem to reduce VT recurrence nor does it affect mortality in such patients. Even though most of the published literature points at this direction, validation from randomized controlled trials is imperative.
Assuntos
Angiografia Coronária , Isquemia Miocárdica , Revascularização Miocárdica , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Revascularização Miocárdica/métodos , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/fisiopatologia , Angiografia Coronária/métodosRESUMO
Risk stratification for sudden cardiac death in dilated cardiomyopathy is a field of constant debate, and the currently proposed criteria have been widely questioned due to their low positive and negative predictive value. In this study, we conducted a systematic review of the literature utilizing the PubMed and Cochrane library platforms, in order to gain insight about dilated cardiomyopathy and its arrhythmic risk stratification utilizing noninvasive risk markers derived mainly from 24 h electrocardiographic monitoring. The obtained articles were reviewed in order to register the various electrocardiographic noninvasive risk factors used, their prevalence, and their prognostic significance in dilated cardiomyopathy. Premature ventricular complexes, nonsustained ventricular tachycardia, late potentials on Signal averaged electrocardiography, T wave alternans, heart rate variability and deceleration capacity of the heart rate, all have both some positive and negative predictive value to identify patients in higher likelihood for ventricular arrhythmias and sudden cardiac death. Corrected QT, QT dispersion, and turbulence slope-turbulence onset of heart rate have yet to establish a predictive correlation in the literature. Although ambulatory electrocardiographic monitoring is frequently used in clinical practice in DCM patients, no single risk marker can be used for the selection of patients at high-risk for malignant ventricular arrhythmic events and sudden cardiac death who could benefit from the implantation of a defibrillator. More studies are needed in order to establish a risk score or a combination of risk factors with the purpose of selecting high-risk patients for ICD implantation in the context of primary prevention.