Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Diabetes ; 67(12): 2657-2667, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30213823

RESUMO

Increasing evidence points to the fact that defects in the resolution of inflammatory pathways predisposes individuals to the development of chronic inflammatory diseases, including diabetic complications such as accelerated atherosclerosis. The resolution of inflammation is dynamically regulated by the production of endogenous modulators of inflammation, including lipoxin A4 (LXA4). Here, we explored the therapeutic potential of LXA4 and a synthetic LX analog (Benzo-LXA4) to modulate diabetic complications in the streptozotocin-induced diabetic ApoE-/- mouse and in human carotid plaque tissue ex vivo. The development of diabetes-induced aortic plaques and inflammatory responses of aortic tissue, including the expression of vcam-1, mcp-1, il-6, and il-1ß, was significantly attenuated by both LXA4 and Benzo-LXA4 in diabetic ApoE-/- mice. Importantly, in mice with established atherosclerosis, treatment with LXs for a 6-week period, initiated 10 weeks after diabetes onset, led to a significant reduction in aortic arch plaque development (19.22 ± 2.01% [diabetic]; 12.67 ± 1.68% [diabetic + LXA4]; 13.19 ± 1.97% [diabetic + Benzo-LXA4]). Secretome profiling of human carotid plaque explants treated with LXs indicated changes to proinflammatory cytokine release, including tumor necrosis factor-α and interleukin-1ß. LXs also inhibited platelet-derived growth factor-stimulated vascular smooth muscle cell proliferation and transmigration and endothelial cell inflammation. These data suggest that LXs may have therapeutic potential in the context of diabetes-associated vascular complications.


Assuntos
Anti-Inflamatórios não Esteroides/uso terapêutico , Aorta/efeitos dos fármacos , Aterosclerose/tratamento farmacológico , Diabetes Mellitus Experimental/tratamento farmacológico , Inflamação/tratamento farmacológico , Lipoxinas/uso terapêutico , Animais , Anti-Inflamatórios não Esteroides/farmacologia , Aterosclerose/etiologia , Quimiocina CCL2/metabolismo , Citocinas/metabolismo , Diabetes Mellitus Experimental/complicações , Humanos , Inflamação/etiologia , Interleucina-1beta/metabolismo , Interleucina-6/metabolismo , Lipoxinas/farmacologia , Camundongos , Molécula 1 de Adesão de Célula Vascular/metabolismo
2.
Vasc Endovascular Surg ; 51(5): 274-281, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28639918

RESUMO

PURPOSE: To assess rates of complications, secondary interventions, survival, and cause of death following endovascular abdominal aortic aneurysm (AAA) repair over a 10-year period. MATERIALS AND METHODS: Single-institution retrospective cohort study of all patients undergoing primary endovascular aortic aneurysm repair (EVAR) between July 2006 and June 2015. The population constituted 175 patients with 163 fusiform and 12 saccular AAAs. Of these, 149 (85%) were male, with mean age 75.4 (±7.1) years. Patients were followed up until June 30, 2016. Cause of death was determined from the national death register. RESULTS: Mean follow-up was 34.4 (±24.4) months. The secondary intervention rate was 9.7%, and there were 4 aneurysm ruptures (0.8% annual incidence). Thirty-day mortality was 0.6%. Survival at 1, 3, and 5 years was 93.1%, 84%, and 64.9%, respectively. Forty-eight patients died during follow-up, 3 secondary to rupture, leading to overall and aneurysm-related death rates of 9.7 and 0.6 per 100 person-years. All other deaths were due to nonaneurysm causes, most commonly cardiovascular (n = 15), pulmonary (n = 13), and malignancy (n = 9). Baseline renal impairment ( P < .001), ischemic heart disease ( P < .05), age greater than 75 years ( P < .05), and urgent/emergency EVAR were associated with inferior long-term survival. Type II endoleak negatively influenced fusiform aneurysm sac regression ( P = .02), but there was no association between survival and occurrence of any complication or secondary intervention. CONCLUSION: The majority of deaths during medium-term follow-up post-EVAR are due to nonaneurysm-related causes. Survival is determined by the following baseline factors: renal impairment, ischemic heart disease, advanced age, and the presence of a symptomatic/ruptured aneurysm.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Causas de Morte , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Irlanda , Estimativa de Kaplan-Meier , Masculino , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
J Vasc Surg ; 53(4): 942-9, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21345636

RESUMO

BACKGROUND: Proximal aortic dissections are life-threatening conditions that require immediate surgical intervention to avert an untreated mortality rate that approaches 50% at 48 hours. Advances in computed tomography (CT) imaging techniques have permitted increased characterization of aortic dissection that are necessary to assess the design and applicability of new treatment paradigms. METHODS: All patients presenting during a 2-year period with acute proximal aortic dissections who underwent CT scanning were reviewed in an effort to establish a detailed assessment of their aortic anatomy. Imaging studies were assessed in an effort to document the location of the primary proximal fenestration, the proximal and distal extent of the dissection, and numerous morphologic measurements pertaining to the aortic valve, root, and ascending aorta to determine the potential for an endovascular exclusion of the ascending aorta. RESULTS: During the study period, 162 patients presented with proximal aortic dissections. Digital high-resolution preoperative CT imaging was performed on 76 patients, and 59 scans (77%) were of adequate quality to allow assessment of anatomic suitability for treatment with an endograft. In all cases, the dissection plane was detectable, yet the primary intimal fenestration was identified in only 41% of the studies. Scans showed 24 patients (32%) appeared to be anatomically amenable to such a repair (absence of valvular involvement, appropriate length and diameter of proximal sealing regions, lack of need to occlude coronary vasculature). Of the 42 scans that were determined not to be favorable for endovascular repair, the most common exclusion finding was the absence of a proximal landing zone (n = 15; 36%). CONCLUSIONS: Appropriately protocoled CT imaging provides detailed anatomic information about the aortic root and ascending aorta, allowing the assessment of which dissections have proximal fenestrations that may be amenable to an endovascular repair.


Assuntos
Aneurisma Aórtico/diagnóstico por imagem , Dissecção Aórtica/diagnóstico por imagem , Aortografia/métodos , Implante de Prótese Vascular , Procedimentos Endovasculares , Seleção de Pacientes , Tomografia Computadorizada por Raios X , Idoso , Algoritmos , Dissecção Aórtica/cirurgia , Aneurisma Aórtico/cirurgia , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/instrumentação , Humanos , Pessoa de Meia-Idade , Ohio , Valor Preditivo dos Testes , Cuidados Pré-Operatórios , Interpretação de Imagem Radiográfica Assistida por Computador , Stents
5.
J Vasc Surg ; 47(3): 629-31, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18295115

RESUMO

Stent graft repair of aortic pathology involving the distal aortic arch requires precise device deployment based on excellent imaging and stable hemodynamics. An inadequate proximal seal may result in a type I endoleak, which may require an additional device or even conversion to open surgery to control. This case report describes transvenous rapid pacing, a safe and reproducible technique to allow precise deployment or balloon dilation of a stent graft in the distal arch or proximal thoracic aorta.


Assuntos
Aneurisma Aórtico/cirurgia , Coartação Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Estimulação Cardíaca Artificial , Cateterismo , Stents , Função Ventricular Direita , Idoso , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/fisiopatologia , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/fisiopatologia , Aortografia , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA