Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Cureus ; 15(3): e36329, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37077608

RESUMO

Introduction Limited guidance exists for primary and urgent care ultrasound applications. This study sought to identify the most useful applications for providers in these clinical settings, to create and implement a structured interdisciplinary point-of-care ultrasound (POCUS) curriculum, and to assess the effectiveness of the course.  Methods This prospective cohort study took place at an urban academic medical center. After a needs-based assessment of ultrasound applications in primary and urgent care, the Emergency Medicine ultrasound faculty and fellows were paired with a primary or urgent care provider (N = 6). The pairings met for scanning sessions in the emergency department to practice image acquisition, documentation, and incorporation of ultrasound into the workflow. Participants were given POCUS pre-work to review before each session. The final bedside session included a formal Objective Standard Clinical Examination (OSCE) to assess learner proficiency to be cleared for independent imaging. The program was assessed using pre- and post-training surveys.  Results The survey results demonstrated that renal, gallbladder, and soft tissue scans were the most interesting and useful to primary and urgent care providers after completion of the training course.  Conclusion The course was effective, and efficient, simple, high-yield POCUS applications should be included in future programs and organizational guidelines for primary and urgent care POCUS education.

2.
Clin Pract Cases Emerg Med ; 6(1): 1-7, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35226837

RESUMO

INTRODUCTION: The use of point-of care ultrasound (POCUS) in the evaluation of vascular emergencies including abdominal aortic aneurysm and deep vein thrombosis is well established. However, no current guidelines exist to outline the use of POCUS in the management of acute peripheral arterial pathology. CASE SERIES: Here, we present a case series that illustrates the utility of POCUS in the assessment of both traumatic and nontraumatic peripheral arterial disease. Direct visualization of the vasculature via B-mode, color Doppler, and pulsed-wave Doppler assisted in the diagnosis of the following: 1) an acute, post-catheterization thrombus of the proximal radial artery; 2) a complete, traumatic radial artery transection; 3) a forearm hematoma with active arterial extravasation; 4) a traumatic arteriovenous fistula; 5) an acute thrombosis of an artery bypass graft; and 6) an infected pseudoaneurysm. CONCLUSION: The incorporation of POCUS into patient care allowed for rapid identification of significant peripheral arterial pathology and led to changes in clinical management, expedited patient care, and circumvented potentially harmful complications.

3.
Am J Emerg Med ; 49: 393-398, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34325179

RESUMO

OBJECTIVES: Extended Focused Assessment with Sonography for Trauma (eFAST) ultrasound exams are central to the care of the unstable trauma patient. We examined six years of eFAST quality assurance data to identify the most common reasons for false positive and false negative eFAST exams. METHODS: This was an observational, retrospective cohort study of trauma activation patients evaluated in an urban, academic Level 1 trauma center. All eFAST exams that were identified as false positive or false negative exams compared with computed tomography (CT) imaging were included. RESULTS: 4860 eFAST exams were performed on trauma patients. 1450 (29.8%) were undocumented, technically limited, or incomplete (missing images). Of the 3410 remaining exams, 180 (5.27%) were true positive and 3128 (91.7%) were true negative. 27 (0.79%) exams were identified as false positive and 75 (2.19%) were identified as false negative. Of the false positive scans, 7 had no CT scan and 8 had correct real-time trauma paper documentation of eFAST exam results when compared to CT and were excluded, leaving 12 false positive scans. Of the false negative scans, 11 were excluded for concordant documentation in real-time trauma room paper documentation, 20 were excluded for no CT scan, and 2 were excluded as incomplete, leaving 42 false negative scans. Pelvic fluid, double-line sign, pericardial fat pad, and the thoracic portion of the eFAST exam were the most common source of errors. CONCLUSION: The eFAST exams in trauma activation patients are highly accurate. Unfortunately poor documentation and technically limited/incomplete studies represent 29.8% of our eFAST exams. Pelvic fluid, double-line sign, pericardial fat pad, and the thoracic portion of the eFAST exam are the most common source of errors.


Assuntos
Competência Clínica/normas , Avaliação Sonográfica Focada no Trauma/normas , Adulto , Competência Clínica/estatística & dados numéricos , Estudos de Coortes , Feminino , Avaliação Sonográfica Focada no Trauma/métodos , Avaliação Sonográfica Focada no Trauma/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Centros de Traumatologia/organização & administração , Centros de Traumatologia/normas , Centros de Traumatologia/estatística & dados numéricos , Ultrassonografia/métodos , Ultrassonografia/normas , Ultrassonografia/estatística & dados numéricos
4.
Ann Emerg Med ; 77(2): 281-282, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33487327
5.
J Clin Ultrasound ; 49(3): 205-211, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33225452

RESUMO

PURPOSE: Prior research has suggested an association of hepatic venous gas with mortality in cardiac arrest. As point of care ultrasound (POCUS) is frequently used in the context of resuscitation, we sought to evaluate if the presence of hepatic gas on POCUS had a similar mortality association. METHODS: A retrospective review was conducted of patients who experienced nontraumatic cardiac arrest. Archived ultrasound images were independently reviewed to determine the presence of gas in the hepatic parenchyma and vasculature. Electronic medical records were then reviewed to collect remaining clinical data. RESULTS: From 1 January 2017 through 16 June 2019, 87 patients met inclusion criteria. Among them, 68 (78.2%) patients died. Among those who died, 40 (58.8%) had hepatic gas, while 28 (41.2%) had none. Only a single survivor demonstrated hepatic venous gas (11%). While the difference in mortality with respect to presence of undifferentiated hepatic gas was not significant (P = .37), there was a significant difference with respect to the presence of venous gas (P = .004). CONCLUSION: Our study demonstrated that the incidence of postarrest hepatic gas on POCUS was common, and that the presence of hepatic venous gas during cardiac resuscitation was associated with increased mortality, while hepatic parenchymal gas alone was not.


Assuntos
Gases/metabolismo , Parada Cardíaca/diagnóstico por imagem , Parada Cardíaca/mortalidade , Fígado/metabolismo , Sistemas Automatizados de Assistência Junto ao Leito , Ultrassonografia/métodos , Reanimação Cardiopulmonar , Feminino , Parada Cardíaca/metabolismo , Parada Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
6.
West J Emerg Med ; 21(6): 276-283, 2020 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-33207177

RESUMO

INTRODUCTION: The American Heart Association Guidelines for Cardiopulmonary Resuscitation (CPR) recommend pulse checks of less than 10 seconds. We assessed the effect of video review-based educational feedback on pulse check duration with and without point-of-care ultrasound (POCUS). METHODS: Cameras recorded cases of CPR in the emergency department (ED). Investigators reviewed resuscitation videos for ultrasound use during pulse check, pulse check duration, and compression-fraction ratio. Investigators reviewed health records for patient outcomes. Providers received written feedback regarding pulse check duration and compression-fraction ratio. Researchers reviewed selected videos in multidisciplinary grand round presentations, with research team members facilitating discussion. These presentations highlighted strategies that include the following: limit on pulse check duration; emphasis on compressions; and use of "record, then review" method for pulse checks with POCUS. The primary endpoint was pulse check duration with and without POCUS. RESULTS: Over 19 months, investigators reviewed 70 resuscitations with a total of 325 pulse checks. The mean pulse check duration was 11.5 ± 8.8 seconds (n = 224) and 13.8 ± 8.6 seconds (n = 101) without and with POCUS, respectively. POCUS pulse checks were significantly longer than those without POCUS (P = 0.001). Mean pulse check duration per three-month block decreased statistically significantly from study onset to the final study period (from 17.2 to 10 seconds [P<0.0001]) overall; decreased from 16.6 to 10.5 seconds (P<0.0001) without POCUS; and with POCUS from 19.8 to 9.88 seconds (P<0.0001) with POCUS. Pulse check times decreased significantly over the study period of educational interventions. The strongest effect size was found in POCUS pulse check duration (P = -0.3640, P = 0.002). CONCLUSION: Consistent with previous studies, POCUS prolonged pulse checks. Educational interventions were associated with significantly decreased overall pulse-check duration, with an enhanced effect on pulse checks involving POCUS. Performance feedback and video review-based education can improve CPR by increasing chest compression-fraction ratio.


Assuntos
Reanimação Cardiopulmonar/educação , Educação de Pós-Graduação em Medicina/métodos , Serviço Hospitalar de Emergência , Frequência Cardíaca/fisiologia , Monitorização Fisiológica/métodos , Gravação em Vídeo/métodos , Idoso , American Heart Association , Reanimação Cardiopulmonar/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Ultrassonografia/métodos , Estados Unidos
7.
AEM Educ Train ; 4(4): 387-394, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33150281

RESUMO

BACKGROUND: Point-of-care ultrasound (POCUS) is important to the practice of emergency medicine (EM), but requires training to achieve competence. The purpose of this study was to describe the current state of POCUS practice and perceived barriers to the implementation in EM training programs in India. METHODS: A cross-sectional survey consisting of 28 questions was administered to 378 faculty and residents in postgraduate EM training programs across India. RESULTS: Data were collected from 159 physicians from 16 institutions; 76% of them were EM residents, with a response rate of 42%. Respondents overwhelmingly reported high interest (91%) in learning POCUS topics. Respondents identified highest levels of comfort with the performance and interpretation of trauma ultrasound (US) and echocardiography. Conversely, there was a scarce interest and low levels of competence in performing obstetric US, which may be a result of the practice of triaging these complaints to obstetricians and gynecologists. Lack of US equipment and dedicated training were the highest rated barriers by a significant margin, which 56% of respondents ranked as "very important." CONCLUSIONS: While significant interest in POCUS exists among the Indian EM physicians, comfort and competence were limited to trauma and echocardiography applications. Expansion of and comfort with POCUS use in these settings may be sought through improvement of access to US equipment and a dedicated US curriculum.

8.
J Emerg Med ; 53(2): 241-247, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28372830

RESUMO

BACKGROUND: Although air has traditionally been considered a barrier to sonographic imaging, when encountered in unusual settings it can serve as an important indicator of various pathologic states as well. Clinician recognition and thorough understanding of the characteristic pattern of artifacts generated by air are critical for making a number of important diagnoses. CASE SERIES: We present five emergency department cases in which air was visualized in a pathologic location. Pneumothorax, pneumoperitoneum, necrotizing fasciitis, or Fournier's gangrene, and subcutaneous emphysema and pneumomediastinum, can be rapidly and easily identified on ultrasound by the presence of air artifacts. The relevant sonographic findings are described and discussed in this article. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Due to its inherent impedance mismatch with other human tissues, air has a characteristic appearance on ultrasound that includes irregular hyperechoic structures, "dirty shadowing," A-lines, and decreased visualization of deeper structures. Knowledge of the sonographic appearance of air artifacts can assist the physician in making a diagnosis, selecting appropriate additional imaging, and enlisting specialist consultation.


Assuntos
Ar/análise , Ultrassonografia/métodos , Adulto , Idoso , Fasciite Necrosante/diagnóstico , Fasciite Necrosante/fisiopatologia , Feminino , Gangrena de Fournier/diagnóstico , Gangrena de Fournier/fisiopatologia , Humanos , Masculino , Enfisema Mediastínico/diagnóstico , Enfisema Mediastínico/fisiopatologia , Pessoa de Meia-Idade , Pneumoperitônio/diagnóstico , Pneumoperitônio/fisiopatologia , Pneumotórax/diagnóstico , Pneumotórax/fisiopatologia , Sistemas Automatizados de Assistência Junto ao Leito/tendências , Enfisema Subcutâneo/diagnóstico , Enfisema Subcutâneo/fisiopatologia
10.
J Emerg Med ; 53(1): 91-97, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28351511

RESUMO

BACKGROUND: Corrected flow time (FTc) measured via sonography of the carotid artery is a novel method that has shown promising results for predicting fluid responsiveness in shock states. It is a rapid and noninvasive examination that can be taught to emergency physicians with ease. However, its reliability has not been assessed, and the effects of several variables, including respiration and side of evaluation, are unclear. OBJECTIVES: The objectives were to compare carotid FTc during different phases of the respiratory cycle, (at end-inspiration and end-expiration), to compare FTc reproducibility among providers, and to compare FTc on the right and left sides in a given individual. METHODS: The FTc of both the right and left carotid arteries was measured in 16 healthy volunteers during an inspiratory hold and an expiratory hold. Examinations were completed by three sonographers blinded to previous results and were analyzed for reliability and reproducibility. RESULTS: Reliability and reproducibility were poor when comparing sonographers under all circumstances. No significant differences were found when comparing left vs. right sides of measurement regardless of respiratory phase. CONCLUSION: Although this method for predicting fluid responsiveness has many promising aspects, reproducibility between sonographers was found to be poor. No significant difference was found between the two sides of the body or respiratory phase.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Artérias Carótidas/patologia , Mecânica Respiratória/fisiologia , Artérias Carótidas/diagnóstico por imagem , Feminino , Lateralidade Funcional , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Ultrassonografia/métodos
11.
J Clin Ultrasound ; 45(9): 589-591, 2017 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-28186626

RESUMO

Injury to the penis resulting from zipper entrapment is a painful condition that presents a unique anesthetic challenge to the emergency physician and may even require procedural sedation for removal. In this case report, we describe successful removal of zipper entrapment from the penis of a 34-year-old patient after the application of an ultrasound-guided dorsal penile nerve block. We discuss the anatomy, sonographic features, and steps required for the nerve block procedure. © 2017 Wiley Periodicals, Inc. J Clin Ultrasound 45:589-591, 2017.


Assuntos
Prepúcio do Pênis/diagnóstico por imagem , Prepúcio do Pênis/lesões , Bloqueio Nervoso/métodos , Doenças do Pênis/patologia , Nervo Pudendo/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos , Adulto , Anestésicos Locais/administração & dosagem , Antibacterianos/uso terapêutico , Bacitracina/uso terapêutico , Prepúcio do Pênis/patologia , Humanos , Lidocaína/administração & dosagem , Masculino , Necrose , Doenças do Pênis/diagnóstico , Doenças do Pênis/tratamento farmacológico , Pênis/diagnóstico por imagem , Pênis/lesões , Pênis/inervação , Nervo Pudendo/efeitos dos fármacos
13.
Am J Emerg Med ; 34(9): 1779-82, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27324854

RESUMO

BACKGROUND: Point-of-care ultrasound may be used to facilitate foreign body (FB) localization and removal. We hypothesized that injection of normal saline adjacent to an FB may make it easier to detect. METHODS: The study was performed on one embalmed human cadaver. Potential FB sites were created of wood (24), metal (24), and null (24). Two sonographers evaluated each of the 72 sites both before and after a 25-gauge needle was inserted into each incision and 3 cc of normal saline was injected. Accuracy, sensitivity, and specificity were calculated both before and after injection of normal saline. Binomial tests were used to determine the statistical significance of FB detection before and after injection. A 2-tailed Student's t test was used to determine if there was a statistically significant difference between the 2 methods. RESULTS: Preinjection, 116 (81%) of the 144 interpretations (P≤ .001) were correct in their assessment of whether or not an FB was present, with a sensitivity of 81% (95% confidence interval [CI], 72%-88%) and a specificity of 79% (95% CI, 65%-90%). Postinjection, 119 (83%) of these 144 interpretations (P≤ .001) were correct in their assessment of whether or not an FB was present, with a sensitivity of 85% (95% CI, 77%-92%) and a specificity of 77% (95% CI, 63%-88%). This difference was not significant (P=.08; 95% CI, -0.04 to 0.01). DISCUSSION: Ultrasound was reasonably accurate, sensitive, and specific in identifying 1-cm metal and wood FBs. Although accuracy and sensitivity did improve after normal saline injection, this difference was not significant.


Assuntos
Corpos Estranhos/diagnóstico por imagem , Metais , Tela Subcutânea/diagnóstico por imagem , Ultrassonografia , Madeira , Cadáver , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos , Sensibilidade e Especificidade , Cloreto de Sódio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA