RESUMO
Intravascular triggered drug delivery systems (IV-DDS) for local drug delivery include various stimuli-responsive nanoparticles that release the associated agent in response to internal (e.g., pH, enzymes) or external stimuli (e.g., temperature, light, ultrasound, electromagnetic fields, X-rays). We developed a computational model to simulate IV-DDS drug delivery, for which we quantified all model parameters in vivo in rodent tumors. The model was validated via quantitative intravital microscopy studies with unencapsulated fluorescent dye, and with two formulations of temperature-sensitive liposomes (slow, and fast release) encapsulating a fluorescent dye as example IV-DDS. Tumor intra- and extravascular dye concentration dynamics were extracted from the intravital microscopy data by quantitative image processing, and were compared to computer model results. Via this computer model we explain IV-DDS delivery kinetics and identify parameters of IV-DDS, of drug, and of target tissue for optimal delivery. Two parameter ratios were identified that exclusively dictate how much drug can be delivered with IV-DDS, indicating the importance of IV-DDS with fast drug release (~sec) and choice of a drug with rapid tissue uptake (i.e., high first-pass extraction fraction). The computational model thus enables engineering of improved future IV-DDS based on tissue parameters that can be quantified by imaging.
Assuntos
Sistemas de Liberação de Medicamentos/métodos , Desenvolvimento de Medicamentos/métodos , Neoplasias/tratamento farmacológico , Corantes Fluorescentes/química , Cinética , Lipossomos/química , Nanopartículas/metabolismo , TemperaturaRESUMO
PURPOSE: To investigate the feasibility, safety, and absorbed-dose distribution of prostatic artery radioembolization (RE) in a canine model. MATERIALS AND METHODS: Fourteen male castrated beagles received dihydroandrosterone/estradiol to induce prostatic hyperplasia for the duration of the study. Each dog underwent fluoroscopic prostatic artery catheterization. Yttrium-90 (90Y) microspheres (TheraSphere; Boston Scientific, Marlborough, Massachusetts) were delivered to 1 prostatic hemigland (dose escalation from 60 to 200 Gy), with the contralateral side serving as a control. Assessments for adverse events were performed throughout the follow-up (Common Terminology Criteria for Adverse Events v5.0). Positron emission tomography/magnetic resonance (MR) imaging provided a confirmation after the delivery of absorbed-dose distribution. MR imaging was performed before and 3, 20, and 40 days after RE. Tissue harvest of the prostate, rectum, bladder, urethra, penis, and neurovascular bundles was performed 60 days after RE. RESULTS: All the animals successfully underwent RE. Positron emission tomography/MR imaging demonstrated localization to and good coverage of only the treated hemigland. No adverse events occurred. The MR imaging showed a significant dose-dependent decrease in the treated hemigland size at 40 days (25%-60%, P < .001). No extraprostatic radiographic changes were observed. Necropsy demonstrated no gross rectal, urethral, penile, or bladder changes. Histology revealed RE-induced changes in the treated prostatic tissues of the highest dose group, with gland atrophy and focal necrosis. No extraprostatic RE-related histologic findings were observed. CONCLUSIONS: Prostate 90Y RE is safe and feasible in a canine model and leads to focal dose-dependent changes in the gland without inducing unwanted extraprostatic effects. These results suggest that an investigation of nonoperative prostate cancer is warranted.
Assuntos
Braquiterapia , Embolização Terapêutica , Neoplasias da Próstata , Animais , Cães , Humanos , Masculino , Próstata , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radioisótopos de ÍtrioRESUMO
An amendment to this paper has been published and can be accessed via the original article.
RESUMO
PURPOSE: To evaluate the safety, feasibility, and preliminary efficacy of yttrium-90 (90Y) radioembolization (RE) as a minimally invasive treatment in a canine model with presumed spontaneous brain cancers. MATERIALS: Three healthy research dogs (R1-R3) and five patient dogs with spontaneous intra-axial brain masses (P1-P5) underwent cerebral artery RE with 90Y glass microspheres (TheraSphere). 90Y-RE was performed on research dogs from the unilateral internal carotid artery (ICA), middle cerebral artery (MCA), and posterior cerebral artery (PCA) while animals with brain masses were treated from the ICA. Post-treatment 90Y PET/CT was performed along with serial neurological exams by a veterinary neurologist. One month after treatment, research dogs were euthanized and the brains were extracted and sent for microdosimetric and histopathologic analyses. Patient dogs received post-treatment MRI at 1-, 3-, and 6-month intervals with long-term veterinary follow-up. RESULTS: The average absorbed dose to treated tissue in R1-R3 was 14.0, 30.9, and 73.2 Gy, respectively, with maximum doses exceeding 1000 Gy. One month after treatment, research dog pathologic analysis revealed no evidence of cortical atrophy and rare foci consistent with chronic infarcts, e.g., < 2-mm diameter. Absorbed doses to masses in P1-P5 were 45.5, 57.6, 58.1, 45.4, and 64.1 Gy while the dose to uninvolved brain tissue was 15.4, 27.6, 19.2, 16.7, and 33.3 G, respectively. Among both research and patient animals, 6 developed acute neurologic deficits following treatment. However, in all surviving dogs, the deficits were transient resolving between 7 and 33 days post-therapy. At 1 month post-therapy, patient animals showed a 24-94% reduction in mass volume with partial response in P1, P3, and P4 at 6 months post-treatment. While P2 initially showed a response, by 5 months, the mass had advanced beyond pre-treatment size, and the dog was euthanized. CONCLUSION: This proof of concept demonstrates the technical feasibility and safety of 90Y-RE in dogs, while preliminary, initial data on the efficacy of 90Y-RE as a potential treatment for brain cancer is encouraging.
RESUMO
PURPOSE: To evaluate the combination of 90Y radioembolization (Y90) and drug-eluting bead irinotecan (DEBIRI) microspheres in the VX2 rabbit model. MATERIALS AND METHODS: An initial dose finding study was performed in 6 White New Zealand rabbits to identify a therapeutic but subcurative dose of Y90. In total, 29 rabbits were used in four groups: Y90 treatment (n = 8), DEBIRI treatment (n = 6), Y90 + DEBIRI treatment (n = 7), and an untreated control group (n = 8). Hepatic toxicity was evaluated at baseline, 24 h, 72 h, 1 week, and 2 weeks. MRI tumor volume (TV) and enhancing tumor volume were assessed baseline and 2 weeks. Tumor area and necrosis were evaluated on H&E for pathology. RESULTS: Infused activities of 84.0-94.4 MBq (corresponding to 55.1-72.7 Gy) were selected based on the initial dose finding study. Infusion of DEBIRI after Y90 was technically feasible in all cases (7/7). Overall, 21/29 animals survived to 2 weeks, and the remaining animals had extrahepatic disease on necropsy. Liver transaminases were elevated with Y90, DEBIRI, and Y90 + DEBIRI compared to control at 24 h, 72 h, and 1 week post-treatment and returned to baseline by 2 weeks. By TV, Y90 + DEBIRI was the only treatment to show statistically significant reduction at 2 weeks compared to the control group (p = 0.012). The change in tumor volume (week 2-baseline) for both Y90 + DEBIRI versus control (p = 0.002) and Y90 versus control (p = 0.014) was significantly decreased. There were no statistically significant differences among groups on pathology. CONCLUSION: Intra-arterial Y90 + DEBIRI was safe and demonstrated enhanced antitumor activity in rabbit VX2 tumors. This combined approach warrants further investigation.
Assuntos
Antineoplásicos/administração & dosagem , Quimioembolização Terapêutica , Irinotecano/administração & dosagem , Neoplasias Hepáticas Experimentais/terapia , Microesferas , Radioisótopos de Ítrio/administração & dosagem , Animais , Antineoplásicos/efeitos adversos , Quimioembolização Terapêutica/efeitos adversos , Modelos Animais de Doenças , Relação Dose-Resposta a Droga , Estudos de Viabilidade , Irinotecano/efeitos adversos , Neoplasias Hepáticas Experimentais/diagnóstico por imagem , Imageamento por Ressonância Magnética , Necrose , Coelhos , Radioisótopos de Ítrio/efeitos adversosRESUMO
PURPOSE: In Y90 radioembolization, the number of microspheres infused varies by more than a factor of 20 over the shelf-life of the glass radioembolization device. We investigated the effect of the number of Y90 microspheres on normal liver tissue. METHOD: Healthy pigs received lobar radioembolization with glass Y90 microspheres at 4, 8, 12, and 16 days post-calibration, representing a > 20× range in the number of microspheres deposited per milliliter in tissue. Animals were survived for 1-month post-treatment and the livers were explanted and scanned on a micro CT system to fully characterize the microscopic distribution of individual microspheres. A complete 3D microdosimetric evaluation of each liver was performed with a spatially correlated analysis of histopathologic effect. RESULTS: Through whole-lobe microscopic identification of each microsphere, a consistent number of microspheres per sphere cluster was found at 4, 8, and 12 days postcalibration, despite an 8-fold increase in total microspheres infused from days 4 to 12. The additional microspheres instead resulted in more clusters formed and, therefore, a more homogeneous microscopic absorbed dose. The increased absorbed-dose homogeneity resulted in a greater volume fraction of the liver receiving a potentially toxic absorbed dose based on radiobiologic models. Histopathologic findings in the animals support a possible increase in normal liver toxicity in later treatments with more spheres (i.e., ≥ day 12) compared to early treatments with less spheres (i.e., ≤ day 8). CONCLUSION: The microdosimetric evidence presented supports a recommendation of caution when treating large volumes (e.g., right lobe) using glass 90Y microspheres at more than 8 days post-calibration, i.e., after "2nd week" Monday. The favorable normal tissue microscopic distribution and associated low toxicity of first week therapies may encourage opportunities for dose escalation with glass microspheres and could also be considered for patients with decreased hepatic reserve.
Assuntos
Braquiterapia , Embolização Terapêutica , Neoplasias Hepáticas , Exposição à Radiação , Animais , Embolização Terapêutica/efeitos adversos , Neoplasias Hepáticas/radioterapia , Microesferas , Suínos , Radioisótopos de Ítrio/efeitos adversosRESUMO
This review describes the historical development of an imageable spherical embolic agent and focuses on work performed in collaboration between Biocompatibles UK Ltd (a BTG International group company) and the NIH to demonstrate radiopaque bead utility and bring a commercial offering to market that meets a clinical need. Various chemistries have been investigated and multiple prototypes evaluated in search of an optimized product with the right balance of handling and imaging properties. Herein, we describe the steps taken in the development of DC Bead LUMI™, the first commercially available radiopaque drug-eluting bead, ultimately leading to the first human experience of this novel embolic agent in the treatment of liver tumors.
Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/administração & dosagem , Quimioembolização Terapêutica/métodos , Portadores de Fármacos/química , Desenvolvimento de Medicamentos , Neoplasias Hepáticas/terapia , Animais , Quimioembolização Terapêutica/instrumentação , Meios de Contraste/química , Modelos Animais de Doenças , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Microesferas , Tomografia Computadorizada por Raios X , Resultado do TratamentoRESUMO
The purpose of this study was to evaluate LC Bead LUMI™ (40-90µm and 70-150µm) in order to determine if their increased resistance to compression influences microsphere penetration and distribution compared to more compressible commercial microspheres. LC Bead LUMI™ 40-90µm and 70-150µm, LC BeadM1® 70-150µm, Embozene™ 40µm and Embozene™ 100µm size and distributions were measured using optical microscopy. Penetration in vitro was evaluated using an established 'plate model', consisting of a calibrated tapered gap between a glass plate and plastic housing to allow visual observation of microsphere penetration depth. Behaviour in vivo was assessed using a rabbit renal embolization model with histopathologic confirmation of vessel penetration depth. Penetration behaviour in vitro was reproducible and commensurate with the measured microsphere size, the smaller the microsphere the deeper the penetration. Comparison of the microsphere diameter measured on the 2D plate model versus the corresponding average microsphere size measured by histopathology in the kidney showed no significant differences (p = > 0.05 Mann-Whitney, demonstrating good in vitro - in vivo predictive capabilities of the plate model) confirming predictable performance for LC Bead LUMI™ (40-90µm and 70-150µm) based on microsphere size, their increased rigidity having no bearing on their depth of penetration and distribution. An assessment of a LC Bead LUMI™ (40-90µm and 70-150µm) has shown that despite having greater resistance to compression, these microspheres behave in a predictable manner within in vitro and in vivo models comparable with more compressible microspheres of similar sizes.
Assuntos
Força Compressiva , Microesferas , Animais , Transporte Biológico , Embolização Terapêutica , Vidro/química , Rim/citologia , Rim/metabolismo , Teste de Materiais , CoelhosRESUMO
PURPOSE: Current release assays have inadequate temporal resolution ( â¼ 10 s) to characterise temperature sensitive liposomes (TSL) designed for intravascular triggered drug release, where release within the first few seconds is relevant for drug delivery. MATERIALS AND METHODS: We developed a novel release assay based on a millifluidic device. A 500 µm capillary tube was heated by a temperature-controlled Peltier element. A TSL solution encapsulating a fluorescent compound was pumped through the tube, producing a fluorescence gradient along the tube due to TSL release. Release kinetics were measured by analysing fluorescence images of the tube. We measured three TSL formulations: traditional TSL (DPPC:DSPC:DSPE-PEF2000,80:15:5), MSPC-LTSL (DPPC:MSPC:DSPE-PEG2000,85:10:5) and MPPC-LTSL (DPPC:MMPC:PEF2000,86:10:4). TSL were loaded with either carboxyfluorescein (CF), Calcein, tetramethylrhodamine (TMR) or doxorubicin (Dox). TSL were diluted in one of the four buffers: phosphate buffered saline (PBS), 10% bovine serum albumin (BSA) solution, foetal bovine serum (FBS) or human plasma. Release was measured between 37-45 °C. RESULTS: The millifluidic device allowed measurement of release kinetics within the first few seconds at â¼5 ms temporal resolution. Dox had the fastest release and highest release %, followed by CF, Calcein and TMR. Of the four buffers, release was fastest in human plasma, followed by FBS, BSA and PBS. CONCLUSIONS: The millifluidic device allows measurement of TSL release at unprecedented temporal resolution, thus allowing adequate characterisation of TSL release at time scales relevant for intravascular triggered drug release. The type of buffer and encapsulated compound significantly affect release kinetics and need to be considered when designing and evaluating novel TSL-drug combinations.
Assuntos
Sistemas de Liberação de Medicamentos/métodos , Liberação Controlada de Fármacos/efeitos dos fármacos , Hipertermia Induzida/métodos , Lipossomos/química , Microfluídica/métodos , Humanos , TemperaturaRESUMO
We have developed a straightforward and efficient method of introducing radiopacity into Polyvinyl alcohol (PVA)-2-Acrylamido-2-methylpropane sulfonic acid (AMPS) hydrogel beads (DC Bead™) that are currently used in the clinic to treat liver malignancies. Coupling of 2,3,5-triiodobenzaldehyde to the PVA backbone of pre-formed beads yields a uniformly distributed level of iodine attached throughout the bead structure (~150mg/mL) which is sufficient to be imaged under standard fluoroscopy and computed tomography (CT) imaging modalities used in treatment procedures (DC Bead LUMI™). Despite the chemical modification increasing the density of the beads to ~1.3g/cm3 and the compressive modulus by two orders of magnitude, they remain easily suspended, handled and administered through standard microcatheters. As the core chemistry of DC Bead LUMI™ is the same as DC Bead™, it interacts with drugs using ion-exchange between sulfonic acid groups on the polymer and the positively charged amine groups of the drugs. Both doxorubicin (Dox) and irinotecan (Iri) elution kinetics for all bead sizes evaluated were within the parameters already investigated within the clinic for DC Bead™. Drug loading did not affect the radiopacity and there was a direct relationship between bead attenuation and Dox concentration. The ability (Dox)-loaded DC Bead LUMI™ to be visualized in vivo was demonstrated by the administration of into hepatic arteries of a VX2 tumor-bearing rabbit under fluoroscopy, followed by subsequent CT imaging.
Assuntos
Antineoplásicos/administração & dosagem , Camptotecina/análogos & derivados , Doxorrubicina/administração & dosagem , Animais , Antineoplásicos/química , Benzaldeídos/química , Camptotecina/administração & dosagem , Camptotecina/química , Linhagem Celular Tumoral , Quimioembolização Terapêutica , Preparações de Ação Retardada , Doxorrubicina/química , Portadores de Fármacos , Liberação Controlada de Fármacos , Feminino , Humanos , Iodobenzenos/química , Troca Iônica , Irinotecano , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Microesferas , Imagem Óptica , Tamanho da Partícula , Álcool de Polivinil/química , Coelhos , Propriedades de Superfície , Tomografia Computadorizada por Raios XRESUMO
Therapeutic embolotherapy is the deliberate occlusion of a blood vessel within the body, which can be for the prevention of internal bleeding, stemming of flow through an arteriovenous malformation, or occlusion of blood vessels feeding a tumor. This is achieved using a wide selection of embolic devices such as balloons, coils, gels, glues, and particles. Particulate embolization is often favored for blocking smaller vessels, particularly within hypervascularized tumors, as they are available in calibrated sizes and can be delivered distally via microcatheters for precise occlusion with associated locoregional drug delivery. Embolic performance has been traditionally evaluated using animal models, but with increasing interest in the 3R's (replacement, reduction, refinement), manufacturers, regulators, and clinicians have shown interest in the development of more sophisticated in vitro methods for evaluation and prediction of in vivo performance. Herein the current progress in developing bespoke techniques incorporating physical handling, fluid dynamics, occlusive behavior, and sustained drug elution kinetics within vascular systems is reviewed. While it is necessary to continue to validate the safety of such devices in vivo, great strides have been made in the development of bench tests that better predict the behavior of these products aligned with the principles of the 3R's.
Assuntos
Embolização Terapêutica/métodos , Microesferas , Animais , HumanosRESUMO
PURPOSE: To evaluate whether technetium-99 (99mTc)-labeled macroaggregated albumin (MAA) can predict subsequent yttrium-90 (90Y) distribution and imaging response in patients with hepatocellular carcinoma (HCC). MATERIALS: Retrospective review was performed of records of 83 patients with HCC who underwent 90Y glass microsphere radioembolization with 99mTc-MAA single photon emission computed tomography (SPECT) and 90Y positron emission tomography (PET)/CT between January 2013 and December 2014. Images were fused to segment the whole liver normal tissue (WLNT) and the largest tumors. Fused images were reviewed and analyzed for comparison of absorbed dose (AD) to tumors and WLNT as calculated from 99mTc-MAA SPECT and from 90Y PET/CT, subjective imaging comparison of 99mTc-MAA SPECT and 90Y PET for tumors and WLNT, and correlation of tumoral AD with response on follow-up CT. RESULTS: Final analysis included 73 and 63 patients for WLNT and tumor 99mTc-MAA/90Y correlation, respectively, and 62 patients for AD vs response. 99mTc-MAA/90Y limit of agreement for each reviewer was viewed as clinically acceptable only for WLNT (-15 to 15 Gy). AD interreviewer variability was clinically acceptable for WLNT but was too broad for tumor. Mean tumor AD for objective response (78%) was 313 Gy vs 234 Gy for nonresponders. No threshold was found between tumor AD and response (P > .1). Catheter mismatch between 99mTc-MAA and 90Y had a direct impact on AD mismatch between the 2 image sets. CONCLUSIONS: 99mTc-MAA was found to be a poor surrogate to quantitatively predict subsequent 90Y AD to hepatocellular tumors. 99mTc-MAA distribution correlated with 90Y distribution in the normal hepatic parenchyma.
Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos/farmacocinética , Agregado de Albumina Marcado com Tecnécio Tc 99m/farmacocinética , Tomografia Computadorizada de Emissão de Fóton Único , Radioisótopos de Ítrio/farmacocinética , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Microesferas , Pessoa de Meia-Idade , Estudos Retrospectivos , Distribuição TecidualRESUMO
PURPOSE: To investigate material density, flow, and viscosity effects on microsphere distribution within an in vitro model designed to simulate hepatic arteries. MATERIALS AND METHODS: A vascular flow model was used to compare distribution of glass and resin surrogates in a clinically derived flow range (60-120 mL/min). Blood-mimicking fluid (BMF) composed of glycerol and water (20%-50% vol/vol) was used to simulate a range of blood viscosities. Microsphere distribution was quantified gravimetrically, and injectate solution was dyed to enable quantification by UV spectrophotometry. Microsphere injection rate (5-30 mL/min) and the influence of contrast agent dilution of injection solution (0%-60% vol/vol) were also investigated. RESULTS: No significant differences in behavior were observed between the glass and resin surrogate materials under any tested flow conditions (P = .182; n = 144 injections). Microspheres tend to align more consistently with the saline injection solution (r2 = 0.5712; n = 144) compared with total BMF flow distribution (r2 = 0.0104; n = 144). The most predictable injectate distribution (ie, greatest alignment with BMF flow, < 5% variation) was demonstrated with > 10-mL/min injection rates of pure saline solution, although < 20% variation with glass microsphere distribution was observed with injection solution containing as much as 30% contrast medium when injected at > 20 mL/min. CONCLUSIONS: Glass and resin yttrium-90 surrogates demonstrated similar distribution in a range of clinically relevant flow conditions, suggesting that microsphere density does not have a significant influence on microsphere distribution. Injection parameters that enhanced the mixing of the spheres with the BMF resulted in the most predictable distribution.
Assuntos
Embolização Terapêutica/métodos , Vidro/química , Artéria Hepática/fisiopatologia , Circulação Hepática , Neoplasias Hepáticas/terapia , Modelos Anatômicos , Modelos Cardiovasculares , Compostos Radiofarmacêuticos/administração & dosagem , Resinas Sintéticas/química , Radioisótopos de Ítrio/administração & dosagem , Velocidade do Fluxo Sanguíneo , Viscosidade Sanguínea , Glicerol/química , Artéria Hepática/patologia , Humanos , Neoplasias Hepáticas/irrigação sanguínea , Microesferas , Fluxo Sanguíneo Regional , Técnicas de Réplica , Água/químicaRESUMO
The objective of this study was to undertake a comprehensive long-term biocompatibility and imaging assessment of a new intrinsically radiopaque bead (LC Bead LUMI™) for use in transarterial embolization. The sterilized device and its extracts were subjected to the raft of ISO10993 biocompatibility tests that demonstrated safety with respect to cytotoxicity, mutagenicity, blood contact, irritation, sensitization, systemic toxicity and tissue reaction. Intra-arterial administration was performed in a swine model of hepatic arterial embolization in which 0.22-1 mL of sedimented bead volume was administered to the targeted lobe(s) of the liver. The beads could be visualized during the embolization procedure with fluoroscopy, DSA and single X-ray snapshot imaging modalities. CT imaging was performed before and 1 h after embolization and then again at 7, 14, 30 and 90 days. LC Bead LUMI™ could be clearly visualized in the hepatic arteries with or without administration of IV contrast and appeared more dense than soluble contrast agent. The CT density of the beads did not deteriorate during the 90 day evaluation period. The beads embolized predictably and effectively, resulting in areas devoid of contrast enhancement on CT imaging suggesting ischaemia-induced necrosis nearby the sites of occlusion. Instances of off target embolization were easily detected on imaging and confirmed pathologically. Histopathology revealed a classic foreign body response at 14 days, which resolved over time leading to fibrosis and eventual integration of the beads into the tissue, demonstrating excellent long-term tissue compatibility.
Assuntos
Embolização Terapêutica/métodos , Hemostáticos/uso terapêutico , Nanopartículas/uso terapêutico , Radiografia Intervencionista/métodos , Animais , Materiais Biocompatíveis/efeitos adversos , Materiais Biocompatíveis/síntese química , Meios de Contraste/efeitos adversos , Meios de Contraste/síntese química , Embolização Terapêutica/efeitos adversos , Hemostáticos/efeitos adversos , Hemostáticos/química , Nanopartículas/efeitos adversos , Nanopartículas/ultraestrutura , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos , Nanomedicina Teranóstica/métodosRESUMO
PURPOSE: Low temperature sensitive liposome (LTSL) encapsulated docetaxel were combined with mild hyperthermia (40-42°C) to investigate in vivo biodistribution and efficacy against a castrate resistant prostate cancer. METHOD: Female athymic nude mice with human prostate PC-3 M-luciferase cells grown subcutaneously into the right hind leg were randomized into six groups: saline (+/- heat), free docetaxel (+/- heat), and LTSL docetaxel (+/- heat). Treatment (15 mg docetaxel/kg) was administered via tail vein once tumors reached a size of 200-300 mm(3). Mice tumor volumes and body weights were recorded for up to 60 days. Docetaxel concentrations of harvested tumor and organ/tissue homogenates were determined by LC-MS. Histological evaluation (Mean vessel density, Ki67 proliferation, Caspase-3 apoptosis) of saline, free Docetaxel and LTSL docetaxel (+/- heat n = 3-5) was performed to determine molecular mechanism responsible for tumor cell killing. RESULT: LTSL/heat resulted in significantly higher tumor docetaxel concentrations (4.7-fold greater compared to free docetaxel). Adding heat to LTSL Docetaxel or free docetaxel treatment resulted in significantly greater survival and growth delay compared to other treatments (p < 0.05). Differences in body weight between all Docetaxel treatments were not reduced by >10% and were not statistically different from each other. Molecular markers such as caspase-3 were upregulated, and Ki67 expression was significantly decreased in the chemo-hyperthermia group. Vessel density was similar post treatment, but the heated group had reduced vessel area, suggesting thermal enhancement in efficacy by reduction in functional perfusion. CONCLUSION: This technique of hyperthermia sensitization and enhanced docetaxel delivery has potential for clinical translation for prostate cancer treatment.
Assuntos
Antineoplásicos/metabolismo , Modelos Animais de Doenças , Hipertermia Induzida/métodos , Neoplasias da Próstata/metabolismo , Taxoides/metabolismo , Animais , Antineoplásicos/administração & dosagem , Linhagem Celular Tumoral , Docetaxel , Sistemas de Liberação de Medicamentos/métodos , Feminino , Humanos , Lipossomos , Masculino , Camundongos , Camundongos Nus , Neoplasias da Próstata/tratamento farmacológico , Neoplasias da Próstata/mortalidade , Distribuição Aleatória , Taxa de Sobrevida/tendências , Taxoides/administração & dosagem , Temperatura , Distribuição Tecidual/efeitos dos fármacos , Distribuição Tecidual/fisiologia , Ensaios Antitumorais Modelo de Xenoenxerto/métodosRESUMO
PURPOSE: To describe first clinical experience with a directly image-able, inherently radio-opaque microspherical embolic agent for transarterial embolization of liver tumors. METHODOLOGY: LC Bead LUMI™ is a new product based upon sulfonate-modified polyvinyl alcohol hydrogel microbeads with covalently bound iodine (~260 mg I/ml). 70-150 µ LC Bead LUMI™ iodinated microbeads were injected selectively via a 2.8 Fr microcatheter to near complete flow stasis into hepatic arteries in three patients with hepatocellular carcinoma, carcinoid, or neuroendocrine tumor. A custom imaging platform tuned for LC LUMI™ microbead conspicuity using a cone beam CT (CBCT)/angiographic C-arm system (Allura Clarity FD20, Philips) was used along with CBCT embolization treatment planning software (EmboGuide, Philips). RESULTS: LC Bead LUMI™ image-able microbeads were easily delivered and monitored during the procedure using fluoroscopy, single-shot radiography (SSD), digital subtraction angiography (DSA), dual-phase enhanced and unenhanced CBCT, and unenhanced conventional CT obtained 48 h after the procedure. Intra-procedural imaging demonstrated tumor at risk for potential under-treatment, defined as paucity of image-able microbeads within a portion of the tumor which was confirmed at 48 h CT imaging. Fusion of pre- and post-embolization CBCT identified vessels without beads that corresponded to enhancing tumor tissue in the same location on follow-up imaging (48 h post). CONCLUSION: LC Bead LUMI™ image-able microbeads provide real-time feedback and geographic localization of treatment in real time during treatment. The distribution and density of image-able beads within a tumor need further evaluation as an additional endpoint for embolization.
Assuntos
Carcinoma Hepatocelular/terapia , Embolização Terapêutica/métodos , Neoplasias Hepáticas/terapia , Resinas Acrílicas/uso terapêutico , Idoso de 80 Anos ou mais , Angiografia Digital , Carcinoma Hepatocelular/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Fluoroscopia , Humanos , Fígado/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Microesferas , Pessoa de Meia-Idade , Álcool de Polivinil/uso terapêutico , Resultado do TratamentoRESUMO
PURPOSE: Embolotherapy using microshperes is currently performed with soluble contrast to aid in visualization. However, administered payload visibility dimishes soon after delivery due to soluble contrast washout, leaving the radiolucent bead's location unknown. The objective of our study was to characterize inherently radiopaque beads (RO Beads) in terms of physicomechanical properties, deliverability and imaging visibility in a rabbit VX2 liver tumor model. MATERIALS AND METHODS: RO Beads, which are based on LC Bead® platform, were compared to LC Bead. Bead size (light microscopy), equilibrium water content (EWC), density, X-ray attenuation and iodine distribution (micro-CT), suspension (settling times), deliverability and in vitro penetration were investigated. Fifteen rabbits were embolized with either LC Bead or RO Beads + soluble contrast (iodixanol-320), or RO Beads+dextrose. Appearance was evaluated with fluoroscopy, X-ray single shot, cone-beam CT (CBCT). RESULTS: Both bead types had a similar size distribution. RO Beads had lower EWC (60-72%) and higher density (1.21-1.36 g/cc) with a homogeneous iodine distribution within the bead's interior. RO Beads suspension time was shorter than LC Bead, with durable suspension (>5 min) in 100% iodixanol. RO Beads ≤300 µm were deliverable through a 2.3-Fr microcatheter. Both bead types showed similar penetration. Soluble contrast could identify target and non-target embolization on fluoroscopy during administration. However, the imaging appearance vanished quickly for LC Bead as contrast washed-out. RO Beads+contrast significantly increased visibility on X-ray single shot compared to LC Bead+contrast in target and non-target arteries (P=0.0043). Similarly, RO beads demonstrated better visibility on CBCT in target arteries (P=0.0238) with a trend in non-target arteries (P=0.0519). RO Beads+dextrose were not sufficiently visible to monitor embolization using fluoroscopy. CONCLUSION: RO Beads provide better conspicuity to determine target and non-target embolization compared to LC Bead which may improve intra-procedural monitoring and post-procedural evaluation of transarterial embolization.
Assuntos
Embolização Terapêutica/métodos , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/terapia , Microesferas , Radiografia/métodos , Coloração e Rotulagem/métodos , Animais , Modelos Animais de Doenças , Avaliação Pré-Clínica de Medicamentos , Fluoroscopia , Neoplasias Hepáticas/diagnóstico por imagem , CoelhosRESUMO
PURPOSE: To develop a simple method to produce radiopaque drug-eluting microspheres (drug-eluting beads [DEBs]) that could be incorporated into the current clinical transcatheter arterial chemoembolization workflow and evaluate their performance in vitro and in vivo. MATERIALS AND METHODS: An ethiodized oil (Lipiodol; Guerbet, Villepinte, France) and ethanol solution was added to a lyophilized 100-300 µm bead before loading with doxorubicin. These radiopaque drug-eluting beads (DEBs; Biocompatibles UK Ltd, Farnham, United Kingdom) were evaluated in vitro for x-ray attenuation, composition, size, drug loading and elution, and correlation between attenuation and doxorubicin concentration. In vivo conspicuity was evaluated in a VX2 tumor model. RESULTS: Lipiodol was loaded into lyophilized beads using two glass syringes and a three-way stopcock. Maximum bead attenuation was achieved within 30 minutes. X-ray attenuation of radiopaque beads increased linearly (21-867 HU) with the amount of beads (0.4-12.5 vol%; R(2) = 0.9989). Doxorubicin loading efficiency and total amount eluted were similar to DC Bead (Biocompatibles UK Ltd); however, the elution rate was slower for radiopaque DEBs (P < .05). Doxorubicin concentration linearly correlated with x-ray attenuation of radiopaque DEBs (R(2) = 0. 99). Radiopaque DEBs were seen in tumor feeding arteries after administration by fluoroscopy, computed tomography, and micro-computed tomography, and their location was confirmed by histology. CONCLUSIONS: A simple, rapid method to produce radiopaque DEBs was developed. These radiopaque DEBs provided sufficient conspicuity to be visualized with x-ray imaging techniques.
Assuntos
Quimioembolização Terapêutica/instrumentação , Portadores de Fármacos , Neoplasias Hepáticas Experimentais/terapia , Microesferas , Animais , Modelos Animais de Doenças , Doxorrubicina/administração & dosagem , Óleo Etiodado/administração & dosagem , Fígado/diagnóstico por imagem , Neoplasias Hepáticas Experimentais/diagnóstico por imagem , Imagens de Fantasmas , Coelhos , Microtomografia por Raio-XRESUMO
PURPOSE: To quantify changes in tumor microvascular (< 1 mm) perfusion relative to commonly used angiographic endpoints. MATERIALS AND METHODS: Rabbit Vx2 liver tumors were embolized with 100-300-µm LC Bead particles to endpoints of substasis or complete stasis (controls were not embolized). Microvascular perfusion was evaluated by delivering two different fluorophore-conjugated perfusion markers (ie, lectins) through the catheter before embolization and 5 min after reaching the desired angiographic endpoint. Tumor microvasculature was labeled with an anti-CD31 antibody and analyzed with fluorescence microscopy for perfusion marker overlap/mismatch. Data were analyzed by analysis of variance and post hoc test (n = 3-5 per group; 18 total). RESULTS: Mean microvascular density was 70 vessels/mm(2) ± 17 (standard error of the mean), and 81% ± 1 of microvasculature (ie, CD31(+) structures) was functionally perfused within viable Vx2 tumor regions. Embolization to the extent of substasis eliminated perfusion in 37% ± 9 of perfused microvessels (P > .05 vs baseline), whereas embolization to the extent of angiographic stasis eliminated perfusion in 56% ± 8 of perfused microvessels. Persistent microvascular perfusion following embolization was predominantly found in the tumor periphery, adjacent to normal tissue. Newly perfused microvasculature was evident following embolization to substasis but not when embolization was performed to complete angiographic stasis. CONCLUSIONS: Nearly half of tumor microvasculature remained patent despite embolization to complete angiographic stasis. The observed preservation of tumor microvasculature perfusion with angiographic endpoints of substasis and stasis may have implications for tumor response to embolotherapy.
Assuntos
Embolização Terapêutica , Neoplasias Hepáticas Experimentais/irrigação sanguínea , Neoplasias Hepáticas Experimentais/terapia , Microvasos , Análise de Variância , Animais , Microscopia de Fluorescência , CoelhosRESUMO
Purpose To assess the visibility of radiopaque microspheres during transarterial embolization (TAE) in the VX2 rabbit liver tumor model by using multimodality imaging, including single-snapshot radiography, cone-beam computed tomography (CT), multidetector CT, and micro-CT. Materials and Methods The study was approved by the institutional animal care and use committee. Fifteen VX2-tumor-bearing rabbits were assigned to three groups depending on the type of embolic agent injected: 70-150-µm radiopaque microspheres in saline (radiopaque microsphere group), 70-150-µm radiopaque microspheres in contrast material (radiopaque microsphere plus contrast material group), and 70-150-µm radiolucent microspheres in contrast material (nonradiopaque microsphere plus contrast material group). Rabbits were imaged with single-snapshot radiography, cone-beam CT, and multidetector CT. Three to 5 weeks after sacrifice, excised livers were imaged with micro-CT and histologic analysis was performed. The visibility of the embolic agent was assessed with all modalities before and after embolization by using a qualitative three-point scale score reading study and a quantitative assessment of the signal-to-noise ratio (SNR) change in various regions of interest, including the tumor and its feeding arteries. The Kruskal-Wallis test was used to compare the rabbit characteristics across groups, and the Wilcoxon signed rank test was used to compare SNR measurements before and after embolization. Results Radiopaque microspheres were qualitatively visualized within tumor feeding arteries and targeted tissue with all imaging modalities (P < .05), and their presence was confirmed with histologic examination. SNRs of radiopaque microsphere deposition increased after TAE on multidetector CT, cone-beam CT, and micro-CT images (P < .05). Similar results were obtained when contrast material was added to radiopaque microspheres, except for additional image attenuation due to tumor enhancement. For the group with nonradiopaque microspheres and contrast material, retained tumoral contrast remained qualitatively visible with all modalities except for micro-CT, which demonstrated soluble contrast material washout over time. Conclusion Radiopaque microspheres were visible with all imaging modalities and helped increase conspicuity of the tumor as well as its feeding arteries after TAE in a rabbit VX2 liver tumor model. (©) RSNA, 2015.