Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
PLoS One ; 15(8): e0237179, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32760149

RESUMO

Percutaneous osseointegrated (OI) implants are increasingly viable as an alternative to socket suspension of prosthetic limbs. Upper extremity prostheses have also become more complex to better replicate hand and arm function and attempt to recreate pre-amputation functional levels. With more functionality comes heavier devices that put more stress on the bone-implant interface, which could be an issue for implant stability. This study quantified transhumeral loading at defined amputation levels using four simulated prosthetic limb-types: (1) body powered hook, (2) myoelectric hook, (3) myoelectric hand, and (4) advanced prosthetic limb. Computational models were constructed to replicate the weight distribution of each prosthesis type, then applied to motion capture data collected during Advanced Activities of Daily Living (AADLs). For activities that did not include a handheld weight, the body powered prosthesis bending moments were 13-33% (range of means for each activity across amputation levels) of the intact arm moments (reference 100%), torsional moments were 12-15%, and axial pullout forces were 30-40% of the intact case (p≤0.001). The myoelectric hook and hand bending moments were 60-99%, torsional moments were 44-97%, and axial pullout forces were 62-101% of the intact case. The advanced prosthesis bending moments were 177-201%, torsional moments were 164-326%, and axial pullout forces were 133-185% of the intact case (p≤0.001). The addition of a handheld weight for briefcase carry and jug lift activities reduced the overall impact of the prosthetic model itself, where the body powered forces and moments were much closer to those of the intact model, and more complex prostheses further increased forces and moments beyond the intact arm levels. These results reveal a ranked order in loading magnitude according to complexity of the prosthetic device, and highlight the importance of considering the patient's desired terminal device when planning post-operative percutaneous OI rehabilitation and training.


Assuntos
Membros Artificiais/normas , Osseointegração , Torção Mecânica , Suporte de Carga , Membros Artificiais/efeitos adversos , Membros Artificiais/classificação , Fenômenos Biomecânicos , Interface Osso-Implante/fisiologia , Interface Osso-Implante/fisiopatologia , Humanos , Úmero/fisiologia , Úmero/fisiopatologia
2.
Clin Biomech (Bristol, Avon) ; 72: 108-114, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31862604

RESUMO

BACKGROUND: Percutaneous osseointegrated devices for skeletal fixation of prosthetic limbs have the potential to improve clinical outcomes in the transhumeral amputee population. Initial endoprosthesis stability is paramount for long-term osseointegration and safe clinical introduction of this technology. We evaluated an endoprosthetic design featuring a distally porous coated titanium stem with proximal slots for placement of bicortical interlocking screws. METHODS: Yield load, ultimate failure load, and construct stiffness were measured in 18 pairs of fresh-frozen and thawed cadaver humeri, at distal and proximal amputation levels, without and with screws, under axial pull-out, torsion, and bending loads. Paired statistical comparisons were performed without screws at the two resection levels, and at distal and proximal levels with and without screws. FINDINGS: Without screws, the location of the amputation influenced the stability only in torsional yield (p = 0.032) and torsional ultimate failure (p = 0.033). Proximally, the torsional yield and the torsional ultimate failure were 44% and 47% of that distally. Screws improved stability. In axial pull-out, screws increased the distal ultimate failure 3.2 times (p = 0.003). In torsion, screws increased the yield at the proximal level 1.9 times (p = 0.035), distal ultimate failure load 3.3 times (p = 0.016) and proximal ultimate failure 6.4 times (p = 0.013). In bending, screws increased ultimate failure at the proximal level 1.6 times (p = 0.026). INTERPRETATION: Proximal slots and bicortical interlocking screws may find application in percutaneous osseointegrated devices for patients with amputations, especially in the less stable proximal bone of a short residual limb.


Assuntos
Amputados , Parafusos Ósseos , Úmero/cirurgia , Fenômenos Mecânicos , Osseointegração , Fenômenos Biomecânicos , Placas Ósseas , Feminino , Humanos , Masculino
3.
Anat Rec (Hoboken) ; 302(10): 1709-1717, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30989818

RESUMO

Percutaneous osseointegrated (OI) prosthetic limb attachment holds promise for transhumeral amputees. Understanding humeral medullary morphology is necessary for informed design of upper extremity OI systems, and is beneficial to the field of megaprosthetic reconstruction of the distal humerus where diaphyseal fixation is desired. The purpose of this study was to quantify the sex and laterality differences in humerus morphology, specifically over the diaphysis. Three-dimensional surface reconstructions of 58 pairs of cadaveric humeri (43 male, 15 female) were generated from CT data. Measures describing periosteal and medullary morphology were collected relative to an anatomic coordinate system. Sex and laterality differences in biomechanical length (BML) were observed (P ≤ 0.001 and 0.022, respectively). Head radius was larger in males than females (P ≤ 0.001). Retroversion was increased in right humeri relative to left (P ≤ 0.001). Canal orientation exhibited a conformational shift from anteversion to retroversion distally at approximately 65% BML. Right humeri exhibited larger medullary diameters than left in the 1st and 2nd principal directions (P ≤ 0.024). Males displayed larger diameter medullary canals proximally (P ≤ 0.029) and an increased rate of divergence of the endosteal cortex in the proximal diaphysis (P ≤ 0.009). Females exhibited higher canal aspect ratios at mid-shaft (P ≤ 0.014) and lower mean cortical thickness (P ≤ 0.001). Human humeral diaphysis morphology exhibits sex and laterality differences, which are dependent on position along the diaphysis. Understanding humeral morphology is necessary to achieve adequate primary stability and bone apposition in design of endoprosthetic stems for percutaneous OI implants, and distal humerus replacement. Anat Rec, 302:1709-1717, 2019. © 2019 The Authors. The Anatomical Record published by Wiley Periodicals, Inc. on behalf of American Association for Anatomy.


Assuntos
Úmero/anatomia & histologia , Imageamento Tridimensional , Adolescente , Adulto , Braço , Membros Artificiais , Prótese Ancorada no Osso , Cadáver , Feminino , Humanos , Úmero/diagnóstico por imagem , Úmero/cirurgia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fatores Sexuais , Articulação do Ombro/anatomia & histologia , Tomografia Computadorizada por Raios X , Adulto Jovem
4.
J Shoulder Elbow Surg ; 27(1): 36-43, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28739298

RESUMO

BACKGROUND: The humeral subluxation index (HSI) is frequently assessed on computed tomography (CT) scans in conditions of the shoulder characterized by humeral displacement. An arbitrarily set HSI cutoff value of 45% for anterior subluxation and 55% for posterior subluxation has been widely accepted. We studied whether mean values and thresholds of humeral subluxation, in relation to the glenoid and scapula, were influenced by different imaging modalities. METHODS: The HSIs referenced to the scapula (SHSI) and glenoid (GHSI) were compared between conventional CT scans, CT scans reoriented into the corresponding reference plane (ie, scapular plane for the SHSI and glenoid center plane for the GHSI), and 3-dimensional (3D) CT reconstructions of 120 healthy shoulders. The 95% normal range determined the cutoff values of humeral subluxation. RESULTS: The SHSI thresholds for conventional, reoriented, and 3D CT scans were 33%-61%, 44%-68%, and 49%-61%, respectively. A different mean SHSI was found for each imaging modality (conventional, 47%; reoriented, 56%; 3D, 55%; P ≤ .014), with the conventional SHSI showing an underestimation in 89% of the cases. GHSI thresholds for conventional, reoriented, and 3D CT scans were 40%-61%, 44%-56%, and 46%-54%, respectively. The mean GHSI did not differ between each imaging modality (conventional, 51%; reoriented, 50%; 3D, 50%; P = .146). CONCLUSIONS: The SHSI and GHSI are susceptible to different imaging modalities with consequently different cutoff values. The redefined HSI cutoff values guide physicians in the evaluation of humeral subluxation in conditions characterized by humeral displacement, depending on the available image data.


Assuntos
Cavidade Glenoide/diagnóstico por imagem , Imageamento Tridimensional , Luxação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Escápula/diagnóstico por imagem , Adulto Jovem
5.
PLoS One ; 12(12): e0189418, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29261703

RESUMO

Percutaneous osseointegrated (OI) implants for direct skeletal attachment of upper extremity prosthetics represent an alternative to traditional socket suspension that may yield improved patient function and satisfaction. This is especially true in high-level, transhumeral amputees where prosthetic fitting is challenging and abandonment rates remain high. However, maintaining mechanical integrity of the bone-implant interface is crucial for safe clinical introduction of this technology. The collection of population data on the transhumeral loading environment will aid in the design of compliance and overload protection devices that mitigate the risk of periprosthetic fracture. We collected marker-based upper extremity kinematic data from non-amputee volunteers during advanced activities of daily living (AADLs) that applied dynamic loading to the humerus. Inverse dynamic analysis was applied to calculate the axial force, bending and torsional moments at three virtual amputation levels representing 25, 50, and 75% residual humeral length. The influences of amputation level, elbow flexion constraint, gender and anthropometric scaling were assessed. Results indicate that the proximal (25%) amputation level experienced significantly higher axial forces and bending moments across all subjects when compared to distal amputation levels (p≤0.030). Constraining elbow flexion had a limited influence on peak transhumeral loads. Male subjects experienced higher axial forces during all evaluated activities (p≤0.023). Peak axial force for all activities occurred during jumping jacks (174.5N). Peak bending (57.6Nm) and torsional (57.2Nm) moments occurred during jumping jacks and rapid internal humeral rotation, respectively. Calculated loads fall within the range of implant fixation failure loads reported in cadaveric investigations of humeral stem fixation; indicating that periprosthetic fracture may occur during non-contact AADLs. These kinematic data, collected over a range of AADLs, will aid in the development of overload protection devices and appropriate post-operative rehabilitation protocols that balance return to an active lifestyle with patient safety.


Assuntos
Atividades Cotidianas , Mãos/fisiologia , Úmero/fisiologia , Adolescente , Adulto , Amputação Cirúrgica , Antropometria , Fenômenos Biomecânicos , Demografia , Cotovelo/fisiologia , Feminino , Humanos , Úmero/cirurgia , Locomoção , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Torção Mecânica , Suporte de Carga , Adulto Jovem
6.
J Magn Reson Imaging ; 42(5): 1329-38, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25851109

RESUMO

PURPOSE: To deploy and quantify the accuracy of 3D dual echo steady state (DESS) MR arthrography with hip traction to image acetabular cartilage. Clinical magnetic resonance imaging (MRI) sequences used to image hip cartilage often have reduced out-of-plane resolution and may lack adequate signal-to-noise to image cartilage. MATERIALS AND METHODS: Saline was injected into four cadaver hips placed under traction. 3D DESS MRI scans were obtained before and after cores of cartilage were harvested from the acetabulum; the two MRIs were spatially aligned to reference core positions. The thickness of cartilage cores was measured under microscopy to serve as the reference standard. 3D reconstructions of cartilage and subchondral bone were generated using automatic and semiautomatic image segmentation. Cartilage thickness estimated from the 3D reconstructions was compared to physical measurements using Bland-Altman plots. RESULTS: As revealed by the automatic segmentation mask, saline imbibed the joint space throughout the articulating surface, with the exception of the posteroinferior region in two hips. Locations where air bubbles were introduced and regions of suspected low density bone disrupted an otherwise smooth automatic segmentation mask. Automatic and semiautomatic segmentation yielded a bias ± repeatability coefficient (95% limits of agreement) of 0.10 ± 0.51 mm (-0.41 to 0.61 mm) and 0.06 ± 0.43 mm (-0.37 to 0.49 mm), respectively. CONCLUSION: Cartilage thickness can be estimated to within ∼0.5 mm of the physical value with 95% confidence using 3D reconstructions of 3D DESS MR arthrography images. Manual correction of the automatic segmentation mask may improve reconstruction accuracy.


Assuntos
Acetábulo/anatomia & histologia , Artrografia/métodos , Cartilagem Articular/anatomia & histologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Cadáver , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA