Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Gastrointestin Liver Dis ; 32(4): 479-487, 2023 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-38147619

RESUMO

AIMS: To assess the value of using integrated parametric ultrasound software for contrast-enhanced ultrasonography (CEUS) of liver tumors. METHODS: 107 patients with liver tumors were studied. CEUS were performed to detect focal lesions. Parametric images were based on continuous CINE LOOPs, from the early-arterial phase (15 s) to the portal-venous phase (1 min) generated by perfusion software. The evaluations of the parametric images and their dignity for liver lesions were performed independently by an experienced and a less-experienced investigator. Computed tomography, magnetic resonance imaging scans or histological analysis were used as references. RESULTS: High parametric image quality were obtained in all patients. Among the patients, 44% lesions were benign, 56% were malignant. The experienced investigator correctly classified 46 of 47 (98%) as benign, and 60 of 60 (100%) as malignant tumors based on the parametric images. The less-experienced investigator correctly classified 39 of 47 (83%) as benign, and 49 of 60 (82%) malignant tumors, acheaving a high statistical accuracy of 98% with this type of diagnostic. CONCLUSION: Parametric imaging for grading the malignant degree of tumor may be a good complement to existing ultrasound techniques and was particularly helpful for improving the assessments of the less-experienced examiner.


Assuntos
Interpretação de Imagem Assistida por Computador , Neoplasias Hepáticas , Ultrassonografia , Humanos , Meios de Contraste , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Perfusão/métodos , Sensibilidade e Especificidade , Ultrassonografia/métodos , Software
2.
Chirurgie (Heidelb) ; 2023 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-38097850

RESUMO

BACKGROUND: The incidence of pilonidal sinus shows a steadily rising tendency, especially in the patient age group of up to 40 years. Treatment of this condition is often protracted involving lengthy sick leave and an increased risk of recurrence. The optimal treatment of pilonidal sinus remains open to debate, but it should focus on decreasing the length of hospitalization, promoting a rapid return to daily life, maintaining low pain levels, and keeping costs at a minimum. MATERIALS AND METHODS: In our study conducted between 2017 and 2021, we focused on treatment of pilonidal sinus. We performed 50 elastic ligature procedures with a median observation time of 30 months. The patients were divided into three groups according to the characteristics of pilonidal sinus: (1) acute primary abscess; (2) acute recurrent abscess; and (3) chronic fistula. RESULTS: Out of a total of 50 patients with a subsequent 30-month follow-up, we observed complete recovery in 47 patients and recurrence in three patients. Return to work was possible immediately after the operation, with an average total treatment time of 1 month for complete healing of the defect. CONCLUSION: The current results suggest that the technique of elastic ligature is a desirable solution for pilonidal sinus, because of the initial low costs, no need for hospitalization, and good patient tolerance.

3.
ASAIO J ; 69(4): e134-e141, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36780695

RESUMO

Antithrombogenic coatings of artificial surfaces within extracorporeal membrane oxygenation (ECMO) circuits improved its bio- and hemocompatibility. However, there is still a risk of thrombus formation in particular within the membrane oxygenator (MO). Since inflammatory cells are essential components within clots, the aim was to identify the extent of cellular accumulations on gas exchange capillaries from different ECMO systems. Thirty-four MOs (PLS, n = 27, Getinge; Hilite 7000 LT, n = 7, Fresenius Medical Care, Germany) were collected from adult patients. The extent of cellular deposits on gas exchange capillaries was classified using nuclear 4',6-diamidino-2-phenylindole staining and fluorescence microscopy. All Hilite oxygenators exhibited small cellular deposits. In contrast, the cellular distribution was heterogeneous on capillaries from PLS oxygenators: small deposits (34%), clusters (44%) and membrane-spanning cell structures (pseudomembranes) (22%). Overall, the median fluorescence intensity was significantly higher in the PLS group. Nevertheless, within 3 days before MO removal, there was no alteration in critical parameters ( d -dimer and fibrinogen levels, platelet counts, and pressure drop across the MO). In conclusion, despite the histological differences on the gas capillaries from different types of oxygenators, there was no further evidence of increased inflammation and coagulation parameters that indicate clot formation within oxygenators.


Assuntos
Oxigenação por Membrana Extracorpórea , Trombose , Adulto , Humanos , Oxigenadores de Membrana , Capilares/patologia , Coagulação Sanguínea , Testes de Coagulação Sanguínea , Trombose/etiologia , Trombose/patologia , Oxigenadores
4.
Artigo em Inglês | MEDLINE | ID: mdl-36502312

RESUMO

OBJECTIVE: The study aim was to investigate the use of a novel device, the Vscan Air™, for rapidly and effectively performing ultrasound in student teaching during the COVID-19 pandemic. MATERIAL AND METHODS: As part of the ultrasound practical course with integrated hands-on activity required by the regular medical curriculum, 100 medical students were instructed in the use of the Vscan Air™, including duplex mode. They then evaluated the quality of the ultrasound images obtained by the Vscan Air™ from previously selected organs. RESULTS: 100 students were interviewed (female n = 68, male n = 32; age >18 years n = 100). The rated image quality never fell below a mean of 3 for the examined organs and portal vein flow (liver 4,58; spleen 3,99; kidneys 4,29; aorta 4,16; Douglas/rectovesical space 4,14; portal vein 4,43; pancreas 3,53; Focused Assessment with Sonography for Trauma 4,38). Scores below 3 were found sporadically in ultrasounds of the spleen (n = 4), kidneys (n = 3), Douglas/rectovesical space (n = 2), and pancreas (n = 15). The liver was rated the lowest for 59 ratings. The portal vein was evaluated in 68 cases. The hepatic artery and hepatic veins could be also visualized in all 68 examinations. The aorta was evaluated in 62 cases. CONCLUSION: The Vscan Air™ technology offered adequate image quality and provided a new, fast and patient-oriented technique to support continuous ultrasound examinations and education of students, especially during a pandemic. Particularly noteworthy is the uncomplicated compliance with the required high level of hygiene.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA