Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
J Clin Med ; 13(12)2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38929994

RESUMO

Background: Heart failure (HF) patients experience reduced functional fitness level (determining the performance of routine, daily activities) and diminished exercise capacity (linked to more effortful activities). Aim: The aim of the study is to assess this relationship using functional fitness tests compared to peak VO2 and VE/VCO2 slope in the context of exercise capacity and ventilatory response to exercise. Methods: A total of 382 men with stable HFrEF (age: 61 ± 10, NYHA class I/II/III/IV: 16/50/32/2%, LVEF: 30.5 ± 8.3%) underwent cardiopulmonary exercise testing (CPX) and a Senior Fitness Test (SFT). Afterwards, the patients were divided according to the 2capacity with peak VO2 ≥ 18 mL/kg/min, those with higher or lower ventilatory responses (VE/VCO2 slope ≥ 35 vs. <35) to the exercise were compared. Results: Patients who covered shorter distances in the 6 min walking test showed worse results in the functional tests ('stand up and go', 'chair stand' and 'arm curl') and CPX (lower peak VO2, shorter exercise time and higher VE/VCO2 slope). Subjects classified into Class D demonstrated the worst results in all elements of SFT; those in Class A demonstrated the best results. Significant differences that were analogous occurred also between classes B and C. Among the participants who reached peak VO2 ≥ 18 mL/kg/min (n = 170), those with VE/VCO2 slope ≥ 35 were characterized by worse physical fitness as compared to those with VE/VCO2 < 35. Conclusion: Reduced exercise tolerance led to worsening physical function in patients with HFrEF. Moreover, limitations in physical fitness seem to be distinctive for those patients showing excessive ventilatory response to exercise slope VE/VCO2 (≥35). The Senior Fitness Test may be considered as a useful tool for assessing comprehensive functional and clinical status and risk stratification in patients with HFrEF, especially those with extremely low exercise capacity.

2.
Talanta ; 274: 125914, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38537356

RESUMO

Progress in medical sciences aims for tailored therapy of civilization diseases like diabetes. Preclinical screening of new medicines superior to insulin should include the verification of their affinity to the membrane receptors naturally stimulated by this hormone: insulin receptor isoforms A and B and insulin-like growth factor receptor. Considering that the affinity constants obtained using different experimental conditions are incomparable, it is essential to develop a robust and reliable method to analyze these interactions. The versatile SPR platform developed in this study enables the evaluation of the bioactivity of hypoglycaemic molecules. Thanks to the comprehensive characterization of miscellaneous aspects of the analytical platform, including the design of the SPR biosensor receptor layer, ensuring interaction specificity, as well as the quality control of the standards used (human insulin, HI; long-acting insulin analog: glargine, Gla), the feasibility of the method of equilibrium and kinetic constants determination for insulin-like targets was confirmed. SPR assays constructed in the direct format using IR-A, IR-B, and IGF1-R receptor proteins show high sensitivities and low detection limits towards insulin and glargine detection in the range of 18.3-53.3 nM with no signs of mass transport limitations. The improved analytical performance and stability of SPR biosensors favor the acquisition of good-quality kinetic data, while preservation of receptors activity after binding to long-chain carboxymethyldextran, combined with spontaneous regeneration, results in stability and long shelf life of the biosensor, which makes it useful for label-free insulin analogs biosensing and thus extensive screening in diabetic drugs discovery.


Assuntos
Ensaios de Triagem em Larga Escala , Hipoglicemiantes , Receptor de Insulina , Ressonância de Plasmônio de Superfície , Humanos , Hipoglicemiantes/química , Ressonância de Plasmônio de Superfície/métodos , Receptor de Insulina/metabolismo , Ensaios de Triagem em Larga Escala/métodos , Insulina Glargina/química , Técnicas Biossensoriais/métodos , Insulina/metabolismo , Insulina/análise , Receptor IGF Tipo 1/metabolismo
3.
Biosensors (Basel) ; 14(3)2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38534243

RESUMO

Protein-based microarrays are important tools for high-throughput medical diagnostics, offering versatile platforms for multiplex immunodetection. However, challenges arise in protein microarrays due to the heterogeneous nature of proteins and, thus, differences in their immobilization conditions. This article advocates DNA-directed immobilization (DDI) as a solution, emphasizing its rapid and cost-effective fabrication of biosensing platforms. Thiolated single-stranded DNA and its analogues, such as ZNA® and PNA probes, were used to immobilize model proteins (anti-CRP antibodies and SARS-CoV nucleoprotein). The study explores factors influencing DDI-based immunosensor performance, including the purity of protein-DNA conjugates and the stability of their duplexes with DNA and analogues. It also provides insight into backfilling agent type and probe surface density. The research reveals that single-component monolayers lack protection against protein adsorption, while mixing the probes with long-chain ligands may hinder DNA-protein conjugate anchoring. Conventional DNA probes offer slightly higher surface density, while ZNA® probes exhibit better binding efficiency. Despite no enhanced stability in different ionic strength media, the cost-effectiveness of DNA probes led to their preference. The findings contribute to advancing microarray technology, paving the way for new generations of DDI-based multiplex platforms for rapid and robust diagnostics.


Assuntos
Técnicas Biossensoriais , Imunoensaio , DNA , Sondas de DNA , Proteínas , Antígenos , Biologia
4.
Mikrochim Acta ; 191(2): 95, 2024 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-38224352

RESUMO

A "chemical tongue" is proposed based on thiomalic acid-capped quantum dots (QDs) with signal enrichment provided by excitation-emission matrix (EEM) fluorescence spectroscopy for the determination of close structural analogs-short-length amyloid ß (Aß) peptides related to Alzheimer's disease. Excellent discrimination is obtained by principal component analysis (PCA) for seven derivatives: Aß1-16, Aß4-16, Aß4-9, Aß5-16, Aß5-12, Aß5-9, Aß12-16. Detection of Aß4-16, Aß4-16, and Aß5-9 in binary and ternary mixtures performed by QDs-based chemical tongue using partial least squares-discriminant analysis (PLS-DA) provided perfect 100% accuracy for the two studied peptides (Aß4-16 and Aß4-16), while for the third one (Aß5-9) it was slightly lower (97.9%). Successful detection of Aß4-16 at 1 pmol/mL (1.6 ng/mL) suggests that the detection limit of the proposed method for short-length Aß peptides can span nanomolar concentrations. This result is highly promising for the development of simple and efficient methods for sequence recognition in short-length peptides and better understanding of mechanisms at the QD-analyte interface.


Assuntos
Doença de Alzheimer , Pontos Quânticos , Humanos , Doença de Alzheimer/diagnóstico , Peptídeos beta-Amiloides , Análise Discriminante
5.
Int J Mol Sci ; 24(22)2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-38003267

RESUMO

The aim of this study was to investigate the process of attachment of saccharide particles differing in degree of complexity to cell receptors responsible for transport of glucose across the cell membrane (GLUT proteins). This phenomenon is currently considered when designing modern medicines, e.g., peptide drugs to which glucose residues are attached, enabling drugs to cross the barrier of cell membranes and act inside cells. This study aims to help us understand the process of assimilation of polysaccharide nanoparticles by tumour cells. In this study, the interactions between simple saccharides (glucose and sucrose) and dextran nanoparticles with two species of GLUT proteins (GLUT1 and GLUT4) were measured using the surface plasmon resonance technique. We managed to observe the interactions of glucose and sucrose with both applied proteins. The lowest concentration that resulted in the detection of interaction was 4 mM of glucose on GLUT1. Nanoparticles were measured using the same proteins with a detection limit of 40 mM. These results indicate that polysaccharide nanoparticles interact with GLUT proteins. The measured strengths of interactions differ between proteins; thus, this study can suggest which protein is preferable when considering it as a mean of nanoparticle carrier transport.


Assuntos
Glucose , Ressonância de Plasmônio de Superfície , Glucose/metabolismo , Transportador de Glucose Tipo 1 , Carboidratos , Proteínas Facilitadoras de Transporte de Glucose , Sacarose , Transportador de Glucose Tipo 4
6.
Cardiol J ; 2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37853824

RESUMO

BACKGROUND: Skeletal muscle dysfunction is a feature of heart failure (HF). Iron deficiency (ID) is prevalent in patients with HF associated with exercise intolerance and poor quality of life. Intravenous iron in iron deficient patients with HF has attenuated HF symptoms, however the pathomechanisms remain unclear. The aim of study was to assess whether intravenous iron supplementation as compared to placebo improves energy metabolism of skeletal muscles in patients with HF. METHODS: Men with heart failure with reduced ejection fraction (HFrEF) and ID were randomised in 1:1 ratio to either intravenous ferric carboxymaltose (IV FCM) or placebo. In vivo reduction of lactates by exercising skeletal muscles of forearm was analyzed. A change in lactate production between week 0 and 24 was considered as a primary endpoint of the study. RESULTS: There were two study arms: the placebo and the IV FCM (12 and 11 male patients with HFrEF). At baseline, there were no differences between these two study arms. IV FCM therapy as compared to placebo reduced the exertional production of lactates in exercising skeletal muscles. These effects were accompanied by a significant increase in both serum ferritin and transferrin saturation in the IV FCM arm which was not demonstrated in the placebo arm. CONCLUSIONS: Intravenous iron supplementation in iron deficient men with HFrEF improves the functioning of skeletal muscles via an improvement in energy metabolism in exercising skeletal muscles, limiting the contribution of anaerobic reactions generating ATP as reflected by a lower in vivo lactate production in exercising muscles in patients with repleted iron stores.

7.
Biosens Bioelectron ; 237: 115511, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37429147

RESUMO

Scientific interest in the investigation and application of multifunctional nanomaterials in medical diagnostics has been increasing. The employment of magnetocatalytic immunoconjugates as both analyte-capturing agents and enzyme-like catalytic labels may enable rapid preconcentration and determination of relevant antigens. In this work, we synthesized and comprehensively characterized two types of noble metal-decorated magnetic nanocubes (MDMCs) which were subsequently applied in the one-step, sandwich nanozyme-linked immunosorbent assay (NLISA). Magnetic cores allow for rapid separation from complex samples of biological origin. The catalytically active shell composed of Au-decorated Pt or Ru can effectively mimic the activity of horseradish peroxididase, retaining at the same time the ability to form stable bioconstructs through self-assembly of thiolated ligands. As a result, hybrid multifunctional nanoparticles were synthesized and used to detect C-reactive protein (CRP) in serum samples. We have also paid considerable attention to the mechanistic studies of the formation of sandwich immunocomplexes with nanoparticle labels by means of immunoenzymatic methods and surface plasmon resonance. Analytical parameters of the Pt-MDMCs-labeled NLISA (detection limit LOD = 0.336 ng mL-1, recovery = 98.0%, linear response window covering two logarithmic units) turned out to be superior to the classical, one-step ELISA based on a horseradish peroxidase. In addition, our method offers further possibility of sensitivity adjustment by changing the parameters of magnetic preconcentration, together with good long-term stability of MDMCs conjugates and their good resistance to common interferences. We believe that the proposed simple synthetic protocol will guide a new approach to applying metal-decorated magnetic nanozymes as versatile and multifunctional labels for application in subsequent pre-analytical analyte concentration and immunoassays towards clinical applications.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Proteína C-Reativa , Colorimetria , Técnicas Biossensoriais/métodos , Imunoensaio/métodos , Ouro , Fenômenos Magnéticos
8.
Sensors (Basel) ; 23(8)2023 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-37112287

RESUMO

Methods based on nucleic acid detection are currently the most commonly used technique in COVID-19 diagnostics. Although generally considered adequate, these methods are characterised by quite a long time-to-result and the necessity to prepare the material taken from the examined person-RNA isolation. For this reason, new detection methods are being sought, especially those characterised by the high speed of the analysis process from the moment of sampling to the result. Currently, serological methods of detecting antibodies against the virus in the patient's blood plasma have attracted much attention. Although they are less precise in determining the current infection, such methods shorten the analysis time to several minutes, making it possible to consider them a promising method for screening tests in people with suspected infection. The described study investigated the feasibility of a surface plasmon resonance (SPR)-based detection system for on-site COVID-19 diagnostics. A simple-to-use portable device was proposed for the fast detection of anti-SARS-CoV-2 antibodies in human plasma. SARS-CoV-2-positive and -negative patient blood plasma samples were investigated and compared with the ELISA test. The receptor-binding domain (RBD) of spike protein from SARS-CoV-2 was selected as a binding molecule for the study. Then, the process of antibody detection using this peptide was examined under laboratory conditions on a commercially available SPR device. The portable device was prepared and tested on plasma samples from humans. The results were compared with those obtained in the same patients using the reference diagnostic method. The detection system is effective in the detection of anti-SARS-CoV-2 with the detection limit of 40 ng/mL. It was shown that it is a portable device that can correctly examine human plasma samples within a 10 min timeframe.


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2 , Ressonância de Plasmônio de Superfície , Teste para COVID-19 , Anticorpos Antivirais
9.
Bioelectrochemistry ; 150: 108363, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36608369

RESUMO

The abnormal concentration of microRNAs (miRNAs) can be associated with occurrence of various diseases including cancer, cardiovascular and neurodegenerative, hence they can be considered as potential biomarkers. An attractive approach could be the application of electrochemical methods, particularly where hybridization event between single-stranded deoxyribonucleic acid (ssDNA) or peptide-nucleic acid (PNA) with miRNA strand happens. Recently, the use of various nanomaterials such as gold nanoparticles, graphene oxide, quantum dots as well as catalyzed hairpin assembly or hybridization chain reaction were proposed to further enhance the performance of elaborated sensors. Herein, we present the studies on selection of receptor layer composition for detection of miRNA 141. The possibility of formation of receptor layer and further duplex monolayer between ssDNA or PNA with miRNA was analyzed by atomic force microscopy (AFM) technique. The interaction of ssDNA and PNA probes with miRNA was further verified using surface plasmon resonance (SPR) and quartz - crystal microbalance (QCM) techniques. On the basis of impedance spectroscopy it was shown that the use of unlabelled ssDNA as receptor layer provided 0.1 pM detection limit. This shows that proposed biosensor that is simple in preparation and use is an attractive alternative to other recently presented approaches.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , MicroRNAs , Ácidos Nucleicos Peptídicos , Ácidos Nucleicos Peptídicos/química , DNA de Cadeia Simples , Ouro/química , Técnicas Biossensoriais/métodos , Hibridização de Ácido Nucleico , Limite de Detecção , Sondas de DNA
10.
Molecules ; 27(23)2022 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-36500533

RESUMO

The growing interest in superparamagnetic iron oxide nanoparticles (SPIONs) as potential theranostic agents is related to their unique properties and the broad range of possibilities for their surface functionalization. However, despite the rapidly expanding list of novel SPIONs with potential biomedical applications, there is still a lack of methodologies that would allow in-depth investigation of the interactions of those nanoparticles with biological compounds in human serum. Herein, we present attempts to employ capillary electrophoresis-inductively coupled plasma tandem mass spectrometry (CE-ICP-MS/MS) for this purpose and various obstacles and limitations noticed during the research. The CE and ICP-MS/MS parameters were optimized, and the developed method was used to study the interactions of two different proteins (albumin and transferrin) with various synthesized SPIONs. While the satisfactory resolution between proteins was obtained and the method was applied to examine individual reagents, it was revealed that the conjugates formed during the incubation of the proteins with SPIONs were not stable under the conditions of electrophoretic separation.


Assuntos
Compostos Férricos , Espectrometria de Massas em Tandem , Humanos , Compostos Férricos/química , Proteínas Sanguíneas/metabolismo , Fenômenos Magnéticos
11.
Int J Mol Sci ; 23(16)2022 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-36012139

RESUMO

Nucleic acid extraction and purification are crucial steps in sample preparation for multiple diagnostic procedures. Routine methodologies of DNA isolation require benchtop equipment (e.g., centrifuges) and labor-intensive steps. Magnetic nanoparticles (MNPs) as solid-phase sorbents could simplify this procedure. A wide range of surface coatings employs various molecular interactions between dsDNA and magnetic nano-sorbents. However, a reliable, comparative evaluation of their performance is complex. In this work, selected Fe3O4 modifications, i.e., polyethyleneimine, gold, silica, and graphene derivatives, were comprehensively evaluated for applications in dsDNA extraction. A family of single batch nanoparticles was compared in terms of morphology (STEM), composition (ICP-MS/MS and elemental analysis), surface coating (UV-Vis, TGA, FTIR), and MNP charge (ζ-potential). ICP-MS/MS was also used to unify MNPs concentration allowing a reliable assessment of individual coatings on DNA extraction. Moreover, studies on adsorption medium (monovalent vs. divalent ions) and extraction buffer composition were carried out. As a result, essential relationships between nanoparticle coatings and DNA adsorption efficiencies have been noticed. Fe3O4@PEI MNPs turned out to be the most efficient nano sorbents. The optimized composition of the extraction buffer (medium containing 0.1 mM EDTA) helped avoid problems with Fe3+ stripping, which improved the validity of the spectroscopic determination of DNA recovery.


Assuntos
Nanopartículas de Magnetita , Ácidos Nucleicos , Adsorção , Fenômenos Magnéticos , Nanopartículas de Magnetita/química , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem
12.
Adv Colloid Interface Sci ; 304: 102656, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35367856

RESUMO

Interactions of proteins with nanomaterials draw attention of many research groups interested in fundamental phenomena. However, alongside with valuable information regarding physicochemical aspects of such processes and their mechanisms, they more and more often prove to be useful from a point of view of bioanalytics. Deliberate use of processes based on adsorption of proteins on nanoparticles (or vice versa) allows for a development of new analytical methods and improvement of the existing ones. It also leads to obtaining of nanoparticles of desired properties and functionalities, which can be used as elements of analytical tools for various applications. Due to interactions with nanoparticles, proteins can also gain new functionalities or lose their interfering potential, which from perspective of bioanalytics seems to be very inviting and attractive. In the framework of this article we will discuss the bioanalytical potential of interactions of proteins with a chosen group of nanoparticles, and implementation of so driven processes for biosensing. Moreover, we will show both positive and negative (opportunities and challenges) aspects resulting from the presence of proteins in media/samples containing metal-based nanoparticles or their precursors.


Assuntos
Nanopartículas Metálicas , Nanopartículas , Nanoestruturas , Adsorção , Nanopartículas/química , Nanoestruturas/química , Proteínas/química
13.
Int J Mol Sci ; 23(7)2022 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-35409130

RESUMO

Laser toners appear as attractive materials for barriers and easily laminated interphases for Lab-on-a-Foil microfluidics, due to the excellent adhesion to paper and various membranes or foils. This work shows for the first time a comprehensive study on the adsorption of antibodies on toner-covered poly(ethylene terephthalate) (PET@toner) substrates, together with assessment of such platforms in rapid prototyping of disposable microdevices and microarrays for immunodiagnostics. In the framework of presented research, the surface properties and antibody binding capacity of PET substrates with varying levels of toner coverage (0-100%) were characterized in detail. It was proven that polystyrene-acrylate copolymer-based toner offers higher antibody adsorption efficiency compared with unmodified polystyrene and PET as well as faster adsorption kinetics. Comparative studies of the influence of pH on the effectiveness of antibodies immobilization as well as measurements of surface ζ-potential of PET, toner, and polystyrene confirmed the dominant role of hydrophobic interactions in adsorption mechanism. The applicability of PET@toner substrates as removable masks for protection of foil against permanent hydrophilization was also shown. It opens up the possibility of precise tuning of wettability and antibody binding capacity. Therefore, PET@toner foils are presented as useful platforms in the construction of immunoarrays or components of microfluidic systems.


Assuntos
Poliésteres , Poliestirenos , Adsorção , Anticorpos , Lasers , Microfluídica , Poliésteres/química
14.
Int J Mol Sci ; 23(4)2022 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-35216438

RESUMO

Spherical gold nanoparticles (GNPs), whose unique properties regarding biomedical applications were broadly investigated, are an object of interest as nanocarriers in drug targeted delivery systems (DTDSs). The possibility of surface functionalization, especially in enabling longer half-life in the bloodstream and enhancing cellular uptake, provides an opportunity to overcome the limitations of popular anticancer drugs (such as cisplatin) that cause severe side effects due to their nonselective transportation. Herein, we present investigations of gold nanoparticle-cisplatin systems formation (regarding reaction kinetics and equilibrium) in which it was proved that the formation efficiency and stability strongly depend on the nanoparticle surface functionalization. In this study, the capillary electrophoresis hyphenated with inductively coupled plasma tandem mass spectrometry (CE-ICP-MS/MS) was used for the first time to monitor gold-drug nanoconjugates formation. The research included optimizing CE separation conditions and determining reaction kinetics using the CE-ICP-MS/MS developed method. To characterize nanocarriers and portray changes in their physicochemical properties induced by the surface's processes, additional hydrodynamic size and ζ-potential by dynamic light scattering (DLS) measurements were carried out. The examinations of three types of functionalized GNPs (GNP-PEG-COOH, GNP-PEG-OCH3, and GNP-PEG-biotin) distinguished the essential differences in drug binding efficiency and nanoconjugate stability.


Assuntos
Cisplatino/química , Portadores de Fármacos/química , Ouro/química , Nanopartículas Metálicas/química , Antineoplásicos/química , Difusão Dinâmica da Luz/métodos , Eletroforese Capilar/métodos , Nanoconjugados/química , Tamanho da Partícula , Espectrometria de Massas em Tandem/métodos
15.
Mikrochim Acta ; 188(10): 343, 2021 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-34524529

RESUMO

The presented work concerns pattern-based sensing with quantum dots for the identification and quantification of neurotransmitters by means of excitation-emission fluorescence spectroscopy (2D fluorescence). In the framework of this study, glutathione capped CdSeS/ZnS nanocrystals were used as non-specific nanoreceptors capable of differentiated interaction with neurotransmitters. The pattern-based sensing with QDs was realized by using excitation-emission fluorescence spectroscopy to provide analyte-specific multidimensional optical information. These characteristic fluorescent response patterns were processed by unfolded partial least squares-discriminant analysis, showing that satisfactory identification of all investigated neurotransmitters: dopamine, norepinephrine, epinephrine, serotonin, GABA, and acetylcholine, can be achieved through the proposed sensing strategy. The impact of the considered fluorescence signal (datum, i.e. zeroth-order data acquired per sample; spectrum, i.e. first-order data acquired per sample; excitation-emission matrix, i.e. second-order data acquired per sample) on the sensing capability of glutathione capped QDs was also verified. The best performance parameters such as accuracy, precision, sensitivity, and specificity were obtained using excitation-emission matrices (88.9-93.3%, 0.93-0.95, 0.89-0.93, and 0.99-1.00, respectively). Thus, it was revealed that excitation-emission fluorescence spectroscopy may improve the recognition of neurotransmitters while using only one type of nanoreceptor. Furthermore, is was demonstrated that the proposed excitation-emission fluorescence spectroscopy assisted QD assay coupled with unfolded partial least squares regression can be successfully utilized for quantitative determination of catecholamine neurotransmitters at the micromolar concentration range with R2 in the range 0.916-0.987. Consequently, the proposed sensing strategy has the potential to significantly simplify the sensing element and to expand the pool of bioanalytes so far detectable with the use of QDs.


Assuntos
Compostos de Cádmio/química , Glutationa/química , Nanopartículas/química , Neurotransmissores/análise , Ácido Oleico/química , Pontos Quânticos/química , Compostos de Selênio/química , Sulfetos/química , Compostos de Zinco/química , Quimiometria , Fluorescência , Neurotransmissores/química
16.
Sensors (Basel) ; 21(11)2021 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-34072572

RESUMO

The rapid progress in the development of surface plasmon resonance-based immunosensing platforms offers wide application possibilities in medical diagnostics as a label-free alternative to enzyme immunoassays. The early diagnosis of diseases or metabolic changes through the detection of biomarkers in body fluids requires methods characterized by a very good sensitivity and selectivity. In the case of the SPR technique, as well as other surface-sensitive detection strategies, the quality of the transducer-immunoreceptor interphase is crucial for maintaining the analytical reliability of an assay. In this work, an overview of general approaches to the design of functional SPR-immunoassays is presented. It covers both immunosensors, the design of which utilizes well-known and often commercially available substrates, as well as the latest solutions developed in-house. Various approaches employing chemical and passive binding, affinity-based antibody immobilization, and the introduction of nanomaterial-based surfaces are discussed. The essence of their influence on the improvement of the main analytical parameters of a given immunosensor is explained. Particular attention is paid to solutions compatible with the latest trends in the development of label-free immunosensors, such as platforms dedicated to real-time monitoring in a quasi-continuous mode, the use of in situ-generated receptor layers (elimination of the regeneration step), and biosensors using recombinant and labelled protein receptors.


Assuntos
Técnicas Biossensoriais , Nanoestruturas , Imunoensaio , Reprodutibilidade dos Testes , Ressonância de Plasmônio de Superfície
17.
Eur J Heart Fail ; 23(10): 1677-1686, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34050579

RESUMO

AIMS: Abnormal endogenous erythropoietin (EPO) constitutes an important cause of anaemia in chronic diseases. We analysed the relationships between iron deficiency (ID) and the adequacy of endogenous EPO in anaemic heart failure (HF) patients, and the impact of abnormal EPO on 12-month mortality. METHODS AND RESULTS: We investigated 435 anaemic HF patients (age: 74 ± 10 years; males: 60%; New York Heart Association class I or II: 39%; left ventricular ejection fraction: 43 ± 17%). Patients with EPO higher than expected for a given haemoglobin were considered EPO-resistant whereas those with EPO lower than expected - EPO-deficient. ID was defined as serum ferritin <100 µg/L or 100-299 µg/L with transferrin saturation <20%. EPO-resistant patients (22%) had more advanced HF whereas those with EPO deficiency (57%) were more frequently females and had worse renal function. Lower serum ferritin (indicating depleted body iron stores) was related to higher EPO observed/predicted ratio when adjusted for significant clinical confounders, including C-reactive protein. One year all-cause mortality was 28% in patients with EPO resistance compared to 17% in patients with EPO deficiency and 10% in patients with adequate EPO (log-rank test for the comparison EPO resistance vs. adequate EPO: P = 0.02). When adjusted for other prognosticators, there was still a trend towards increased 12-month mortality in patients with higher EPO level. CONCLUSION: Anaemic HF patients with endogenous EPO deficiency vs. resistance have different clinical and laboratory characteristics. In such patients, ID contributes to EPO resistance independently of inflammation.


Assuntos
Anemia Ferropriva , Anemia , Eritropoetina , Insuficiência Cardíaca , Deficiências de Ferro , Idoso , Idoso de 80 Anos ou mais , Feminino , Hemoglobinas/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade
18.
Cells ; 10(4)2021 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-33917391

RESUMO

Cardiac fibroblasts and cardiomyocytes are the main cells involved in the pathophysiology of myocarditis (MCD). These cells are especially sensitive to changes in iron homeostasis, which is extremely important for the optimal maintenance of crucial cellular processes. However, the exact role of iron status in the pathophysiology of MCD remains unknown. We cultured primary human cardiomyocytes (hCM) and cardiofibroblasts (hCF) with sera from acute MCD patients and healthy controls to mimic the effects of systemic inflammation on these cells. Next, we performed an initial small-scale (n = 3 per group) RNA sequencing experiment to investigate the global cellular response to the exposure on sera. In both cell lines, transcriptomic data analysis revealed many alterations in gene expression, which are related to disturbed canonical pathways and the progression of cardiac diseases. Moreover, hCM exhibited changes in the iron homeostasis pathway. To further investigate these alterations in sera-treated cells, we performed a larger-scale (n = 10 for controls, n = 18 for MCD) follow-up study and evaluated the expression of genes involved in iron metabolism. In both cell lines, we demonstrated an increased expression of transferrin receptor 1 (TFR1) and ferritin in MCD serum-treated cells as compared to controls, suggesting increased iron demand. Furthermore, we related TFR1 expression with the clinical profile of patients and showed that greater iron demand in sera-treated cells was associated with higher inflammation score (interleukin 6 (IL-6), C-reactive protein (CRP)) and advanced neurohormonal activation (NT-proBNP) in patients. Collectively, our data suggest that the malfunctioning of cardiomyocytes and cardiofibroblasts in the course of MCD might be related to alterations in the iron homeostasis.


Assuntos
Fibroblastos/metabolismo , Regulação da Expressão Gênica , Ferro/metabolismo , Miocardite/sangue , Miócitos Cardíacos/metabolismo , Doença Aguda , Adulto , Estudos de Casos e Controles , Sobrevivência Celular , Células Cultivadas , Regulação para Baixo/genética , Feminino , Ferritinas/sangue , Perfilação da Expressão Gênica , Humanos , Inflamação/genética , Inflamação/patologia , Masculino , Pessoa de Meia-Idade , Miocardite/genética , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Receptores da Transferrina/genética , Receptores da Transferrina/metabolismo , Resultado do Tratamento , Regulação para Cima/genética
19.
Nanotechnology ; 32(5): 055704, 2021 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-33059340

RESUMO

Reactive oxygen species (ROS) play an important role in various physiological processes of living organisms. However, their increased concentration is usually considered as a threat for our health. Plants, invertebrates, and vertebrates including humans have various enzymatic and non-enzymatic defence systems against ROS. Unfortunately, both bad condition of surrounding environment and unhealthy lifestyle can interfere with an activity of enzymes responsible for a regulation of ROS levels. Therefore, it is important to look for alternative ROS scavengers, which could be administrated to chosen tissues to prevent pathological processes such as distortion of DNA or RNA structures and oxidation of proteins and lipids. One of the most recently proposed solutions is the application of nanozymes, which could mimic the activity of essential enzymes and prevent excessive activity of ROS. In this work, nanoparticles of Au, Pt, Pd, Ru and Rh were synthesized and studied in this regard. Peroxidase-, catalase (CAT)- and superoxide dismutase (SOD)-like activity of obtained nanoparticles were tested and compared using different methods. The influence of bovine and human albumins on CAT- and peroxidase-like activity was examined. Moreover, in the case of CAT-like activity, an influence of pH and temperature was examined and compared. Determination of SOD-like activity using the methods described for the examination of the activity of native enzyme was not fully successful. Moreover, cytotoxicity of chosen nanoparticles was studied on both regular and tumor cells.

20.
Cardiol J ; 28(3): 391-401, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33140393

RESUMO

BACKGROUND: Metabolic derangements related to tissue energetics constitute an important pathophysiological feature of heart failure. We investigated whether iron deficiency and catabolic/anabolic imbalance contribute to decreased skeletal muscle performance in men with heart failure with reduced ejection fraction (HFrEF), and whether these pathologies are related to each other. METHODS: We comprehensively examined 23 men with stable HFrEF (median age [interquartile range]: 63 [59-66] years; left ventricular ejection fraction: 28 [25-35]%; New York Heart Association class I/II/III: 17/43/39%). We analyzed clinical characteristics, iron status, hormones, strength and fatigability of forearm flexors and quadriceps (surface electromyography), and exercise capacity (6-minute walking test). RESULTS: None of the patients had anemia whereas 8 were iron-deficient. Flexor carpi radialis fatigability correlated with lower reticulocyte hemoglobin content (CHR, p < 0.05), and there was a trend towards greater fatigability in patients with higher body mass index and lower serum ferritin (both p < 0.1). Flexor carpi ulnaris fatigability correlated with lower serum iron and CHR (both p < 0.05). Vastus medialis fatigability was related to lower free and bioavailable testosterone (FT and BT, respectively, both p < 0.05), and 6-minute walking test distance was shorter in patients with higher cortisol/FT and cortisol/BT ratio (both p < 0.05). Lower ferritin and transferrin saturation correlated with lower percentage of FT and BT. Men with HFrEF and iron deficiency had higher total testosterone, but lower percentage of FT and BT. CONCLUSIONS: Iron deficiency correlates with lower bioactive testosterone in men with HFrEF. These two pathologies can both contribute to decreased skeletal muscle performance in such patients.


Assuntos
Insuficiência Cardíaca , Tolerância ao Exercício , Insuficiência Cardíaca/diagnóstico , Humanos , Ferro , Masculino , Pessoa de Meia-Idade , Músculo Esquelético , Volume Sistólico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA