Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
Eye (Lond) ; 2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39075263

RESUMO

BACKGROUND: To investigate the presence of silicone oil (SO)-emulsification on the anterior iris surface with anterior segment optical coherence tomography (AS-OCT). METHODS: In this single-center cross-sectional study, vitrectomized eyes with SO tamponade that underwent AS-OCT imaging and gonioscopy examination during the postoperative follow-up visits, were reviewed. RESULTS: 45 eyes of 42 consecutive patients were included. In 35.6% of the eyes (n = 16) emulsified SO droplets were detected in the anterior chamber (AC) angle by gonioscopy and in 55.6% (n = 25) on the anterior iris surface by AS-OCT imaging. The presence of SO emulsifications in the AC-angle correlated with the presence of SO emulsifications on the anterior iris surface (OR = 13.4, 95% CI [2.179-82.130]; p = 0.005). The accuracy of the AS-OCT predicting the presence of SO in the AC-angle was 71.0% and the sensitivity was 87.5%. No significant association between SO droplets in the AC and other clinical parameters including endotamponade-duration or type of silicone oil were found. The presence of emulsified SO droplets on the anterior iris surface detected by AS-OCT was significantly correlated to postoperative IOP rise (p = 0.027). CONCLUSION: AS-OCT is a suitable method for the detection of SO on the anterior iris surface. SO droplets on the iris surface correlate with elevated postoperative IOP and with the presence of SO in the AC detected by gonioscopy, therefore AS-OCT might be used as a screening method for the detection of SO migration into the AC. TRIAL REGISTRATION NUMBER: Institutional Review Board of the Hamburg Medical Chamber (Ethik-Kommission der Ärztekammer Hamburg): 2023-300372-WF.

2.
J Clin Med ; 13(13)2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38999540

RESUMO

Background: This pilot study aimed to evaluate the Retinal Function Imager (RFI) for visualizing retinal vasculature and assessment of blood flow characteristics in patients with retinal vasculitis. The RFI is a non-invasive imaging device measuring the blood flow velocity (BFV) in secondary and tertiary retinal vessels using hemoglobin as an intrinsic motion-contrast agent. Methods: To test the feasibility of the RFI for patients with retinal vasculitis, capillary perfusion maps (nCPMs) were generated from 15 eyes of eight patients (five females; mean age: 49 ± 12 years) with a mean uveitis duration of 74 ± 85 months. Five of these patients had birdshot chorioretinopathy, and three had primarily non-occlusive venous retinal vasculitis of unknown origin. To reflect that the BFV may be more reduced in patients with prolonged disease, patients were classified into a short-term (uveitis duration: 8-15 months) and a long-term uveitis group (uveitis duration: 60-264 months). Data were compared with healthy controls (16 eyes of 11 patients; mean age 45 ± 12 years; 8 females). Results: The mean BFV in the controls was 3.79 ± 0.50 mm/s in the retinal arteries and 2.35 ± 0.44 mm/s in the retinal veins, which was significantly higher compared to the retinal vasculitis group. Patients revealed an arterial BFV of 2.75 ± 0.74 mm/s (p < 0.001) and a venous BFV of 1.75 ± 0.51 mm/s (p = 0.016). In the short-term group, a trend towards a decreased venular and arteriolar BFV was seen, while a significant reduction was observed in the long-term group. The patients' microvasculature anatomy revealed by the nCPMs appeared unevenly distributed and a lower number of blood vessels were seen, along with a lower degree of complexity of their branching patterns, when compared with controls. Conclusions: This study demonstrated a reduction in venular and arteriolar BFVs in patients with retinal vasculitis. BFV alterations were already observed in early disease stages and became more pronounced in progressed disease. Additionally, we showed that retinal microvasculature changes may be observed by nCPMs. Retinal imaging with the RFI may serve as a diagnostic and quantifying tool in retinal vasculitis.

3.
Retina ; 44(8): 1422-1430, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38569211

RESUMO

PURPOSE: Pediatric traumatic retinal detachment (RD) resulting from open globe injuries (OGIs) or closed globe injuries (CGIs) presents unique challenges due to complexity often resulting in lifelong sequelae. This study compares pediatric traumatic RD outcomes and prognostic factors following OGI and CGI. METHODS: A retrospective analysis reviewed 47 cases of pediatric traumatic RD in children (age <18 years), who underwent RD surgery between 2002 and 2021. Among them, 25 cases were caused by CGI and 22 cases by OGI. Demographics, RD characteristics, surgical procedures, and anatomical and functional results were assessed. Predictive factors for visual outcomes were investigated. RESULTS: In the CGI group, mean (±SD) age was 11 years ± 4 years, and 10 years ± 5 years in the OGI group. Closed globe injury traumatic RD had significantly better preoperative (CGI: logarithm of the minimum angle of resolution 1.39 ± 0.19 (mean ± standard error); OGI: logarithm of the minimum angle of resolution 2.12 ± 0.20) and follow-up (CGI: logarithm of the minimum angle of resolution 0.94 ± 0.19; OGI: logarithm of the minimum angle of resolution 1.85 ± 0.20) best-corrected visual acuity (BCVA) ( P < 0.05). Initial BCVA improvement was observed in CGI only. In multivariable analysis, prognostic factors for favorable BCVA outcomes included higher preoperative BCVA, older age, and absence of proliferative vitreoretinopathy ( P < 0.05). CONCLUSION: Visual prognosis for pediatric traumatic RD remains limited, favoring CGI cases compared with OGI. Baseline BCVA emerged as a major determinant of final visual acuity. Tailored management approaches can optimize treatment results.


Assuntos
Ferimentos Oculares Penetrantes , Descolamento Retiniano , Acuidade Visual , Vitrectomia , Ferimentos não Penetrantes , Humanos , Criança , Descolamento Retiniano/cirurgia , Descolamento Retiniano/etiologia , Descolamento Retiniano/diagnóstico , Estudos Retrospectivos , Masculino , Feminino , Acuidade Visual/fisiologia , Ferimentos Oculares Penetrantes/cirurgia , Ferimentos Oculares Penetrantes/complicações , Ferimentos Oculares Penetrantes/fisiopatologia , Ferimentos Oculares Penetrantes/diagnóstico , Adolescente , Ferimentos não Penetrantes/complicações , Ferimentos não Penetrantes/diagnóstico , Pré-Escolar , Traumatismos Oculares/complicações , Traumatismos Oculares/cirurgia , Traumatismos Oculares/diagnóstico , Traumatismos Oculares/fisiopatologia , Seguimentos , Prognóstico
4.
Sci Rep ; 14(1): 1972, 2024 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-38263379

RESUMO

The purpose of this retrospective pseudonymised data analysis was to determine whether the patient's age has an influence on the safety, efficacy, and prediction accuracy of laser in situ keratomileusis (LASIK) treatment of myopic and hyperopic eyes. This study was performed at CARE Vision GmbH (Düsseldorf, Germany) and included two patient cohorts: an older group with patients > 55 years old and a younger group with patients 30-40 years old. Each patient had a single LASIK treatment. The safety, efficacy, and prediction accuracy of the refractive results were analysed. In total, 682 patients were analysed, with 341 patients in each patient group (one eye per patient). There were 570 myopic eyes and 112 hyperopic eyes. In myopic eyes, the efficacy was significantly influenced by the patient's age but only in myopic eyes (myopic: p ≤ 0.05; hyperopic: p = 0.085), while safety was not significantly influenced by the patient's age in hyperopic or myopic eyes (p = 0.204). We found that LASIK treatment at an older age (> 55 years) resulted in almost the same safety outcomes as a LASIK treatment at a younger age (30-40 years) but with a lower efficacy; the efficacy correlated with the patient's age. If the patient was hyperopic, their age did not influence safety or efficacy.


Assuntos
Hiperopia , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Humanos , Adulto , Pessoa de Meia-Idade , Estudos Retrospectivos , Olho , Lasers
5.
Eye Vis (Lond) ; 10(1): 48, 2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-38057874

RESUMO

BACKGROUND: To assess whether a trifocal intraocular lens (IOL) with neutral spherical aberration (SA) provides better visual and refractive outcomes than a trifocal IOL with negative SA after hyperopic corneal laser ablation. METHODS: This is a retrospective comparative study. Patients were classified according to the IOL implanted after cataract or clear lens phacoemulsification [group 1, PhysIOL FineVision Pod-F (negative SA); group 2, Rayner RayOne Trifocal (neutral SA)]. We evaluated uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), predictability, safety, efficacy, and satisfaction. RESULTS: 198 eyes of 119 patients met the inclusion criteria. Group 1 comprised 120 eyes and group 2 comprised 78 eyes. At completion, the refractive and predictability results were significantly better in group 1 than in group 2 for manifest refraction spherical equivalent (MRSE) (P < 0.001). Differences were not significant for UDVA (P = 0.647), CDVA (P = 0.343), UIVA (P = 0.059), UNVA (P = 0.382), binocular UIVA (P = 0.157), or binocular UNVA (P = 0.527). Safety and efficacy indices in refractive lens exchange (RLE) eyes were 0.96 and 0.91, and 0.89 and 0.93 in groups 1 and 2, respectively (P = 0.254 and 0.168). Patient satisfaction was similar in both groups (P > 0.05, all items). CONCLUSION: In eyes previously treated with hyperopic corneal ablation, implantation of a trifocal IOL with neutral SA provided better efficacy and safety outcomes but worse predictability outcomes than those obtained with a trifocal model with negative SA.

6.
Graefes Arch Clin Exp Ophthalmol ; 261(11): 3307-3313, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37294434

RESUMO

BACKGROUND: To investigate the changes in macular cystic schisis (MCS) and sensitivity during the day in X-linked retinoschisis (XLRS) patients. METHODS: Treatment-naïve patients with genetically verified XLRS underwent best-correlated visual acuity (BCVA) testing with ETDRS charts, spectral domain optical coherence tomography, and microperimetry (MP) twice a day, at 9 a.m. and 4 p.m., to measure changes in central retinal thickness (CRT), macular volume (MV), average threshold (AT), and fixation stability parameters (P1 and P2). RESULTS: At baseline, the BCVA of the 14 eyes of 8 patients amounted 0.73 (± 0.23) LogMAR. Between timepoints, the BCVA increased in 3.21 letters (p = .021), the AV improved in 1.84 dB (p = .03, 9.73%), the CRT decreased in 24.43 µm (p = .007, - 4.05%), and the MV dropped in 0.27 µm3 (p = .016, - 2.68%). P1 and P2 did not variate. The collapse of the MCS led to the reduction of macula thickness. CRT at baseline correlated with the decrease of CRT (Spearman's ρ: - 0.83 [p = .001]). Age and change of BCVA, CRT, and AV did not correlate among one another. Eyes with disrupted ellipsoid zone showed a more prominent change in CRT (p = .050). Photoreceptor outer segment length and integrity of the external limiting membrane and cone outer segment tips were not associated with BCVA, AT, or CRT variation. CONCLUSION: Eyes of treatment-naïve XLRS patients show diurnal macular thickness and function changes. Eyes with pronounced macular thickness show a greater reduction of the MCS. These results should be taken into consideration in upcoming clinical trials in XLRS. TRIAL REGISTRATION NUMBER: Institutional Review Board of the Hamburg Medical Chamber (Ethik-Kommission der Ärztekammer Hamburg): 2020-10,328.

7.
J Clin Med ; 12(11)2023 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-37297924

RESUMO

X-linked retinoschisis (XLRS) shows features also seen in patients with uveitis and is recognized as an uveitis masquerade syndrome. This retrospective study aimed to describe characteristics of XLRS patients with an initial uveitis diagnosis and to contrast these to patients with an initial XLRS diagnosis. Patients referred to a uveitis clinic, which turned out to have XLRS (n = 4), and patients referred to a clinic for inherited retinal diseases (n = 18) were included. All patients underwent comprehensive ophthalmic examinations, including retinal imaging with fundus photography, ultra-widefield fundus imaging, and optical coherence tomography (OCT). In patients with an initial diagnosis of uveitis, a macular cystoid schisis was always interpreted as an inflammatory macular edema; vitreous hemorrhages were commonly interpreted as intraocular inflammation. Patients with an initial diagnosis of XLRS rarely (2/18; p = 0.02) showed vitreous hemorrhages. No additional demographic, anamnestic, and anatomical differences were found. An increased awareness of XLRS as a uveitis masquerade syndrome may facilitate early diagnosis and may prevent unnecessary therapies.

8.
BMC Ophthalmol ; 23(1): 211, 2023 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-37170242

RESUMO

BACKGROUND: Cataract surgery induces corneal endothelial cell loss (ECL). This study investigates the relationship between bottle height (BH) and ECL induced due to irrigation and aspiration (I/A) in cataract surgery and quantifies protective effects of intraoperatively used ophthalmic viscoelastic substances. METHODS: Intermittent I/A without phacoemulsification was performed in porcine eyes for 10 min with varying BHs of 100 cm (BH100), 125 cm (BH125), 150 cm (BH150) or no treatment (control, no I/A). Additionally, in one group a dispersive ophthalmic viscoelastic substance was injected into the anterior eye chamber before treatment with I/A at a BH of 150 cm (BH150 + V). After exposure of the corneal endothelium to I/A, the corneas were prepared to split corneal buttons on day 0 and cultivated for 15 days. Endothelial cell density (ECD) was analyzed blinded on days 1, 8 and 15. RESULTS: Relative ECL significantly correlated with irrigation BH (control (n = 13): -9.69 ± 6.03% (average ± standard deviation); BH100 (n = 12): -9.69 ± 4.81%-p = 1.000; BH125 (n = 14): -19.44 ± 7.30% - p < 0.001; BH150 (n = 13): -21.99 ± 6.70%-p < 0.001). I/A-induced ECL was significantly decreased by the injection of ophthalmic viscoelastic, as BH150 + V (n = 14; -10.92 ± 4.09%-p = 1.000) showed a cell loss comparable to the control group. CONCLUSIONS: ECL is altered by I/A BH and reduced when viscoelastic substances are used.


Assuntos
Extração de Catarata , Catarata , Facoemulsificação , Animais , Suínos , Células Endoteliais , Endotélio Corneano , Contagem de Células
9.
PLoS One ; 18(4): e0283578, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37023053

RESUMO

PURPOSE: To study the influence of angle kappa (κ) on visual acuity after implantation of a multifocal intraocular lens (MIOL) and consecutive "touch-up" corneal refractive surgery with Laser-in-situ-Keratomileusis (LASIK). METHODS: This retrospective multicenter study included patients who underwent MIOL surgery and consecutive LASIK (= Bioptics) in the period from 2016 to 2020 at Care Vision Refractive Centers in Germany. Our study was approved by the local ethics committee at the University in Duesseldorf (approval date: 23.04.2021) and conducted according to the tenets of the Declaration of Helsinki and Good Clinical Practices Guidelines. The pre- and post-operative κ of 548 eyes were measured using a Scheimpflug-based imaging system. Corrected distance visual acuity (CDVA) and the safety index (SI) were analyzed in relation with κ. For a more detailed analysis, the cohort was divided into pre-operative hyperopic and myopic patients to show group-specific differences. RESULTS: There was a significant decrease (p<0.001) in the magnitude of κ after MIOL implantation and Bioptics. However, there was almost no significant correlation of κ on CDVA and SI, pre- and postoperatively. CONCLUSION: A large κ is not a significant risk factor for poor visual acuity. Therefore, it is not a suitable clinical predictor of postoperative outcomes after a Bioptic procedure.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Lentes Intraoculares Multifocais , Humanos , Córnea/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Refração Ocular , Estudos Retrospectivos
10.
J Ophthalmic Vis Res ; 18(1): 3-14, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36937201

RESUMO

Purpose: Currently, two major principles exist to create LASIK flaps: firstly, a strictly horizontal (2D) cut similar to the microkeratome-cut and secondly an angled cut with a "step-like" edge (3D). The strictly horizontal (2D) cut method can be performed using apparatus such as the low-energy FEMTO LDV Z8 laser and its predecessors which are specific to this type. Alternatively, the low-energy FEMTO LDV Z8 laser's 3D flap design creates an interlocking flap-interface surface which potentially contributes toward flap stability. In addition, the FEMTO LDV Z8 offers flap-position adjustments after docking (before flap-creation). The current study analyzed precision, safety, efficacy, as well as patient self-reported pain and comfort levels after applying two different types of LASIK flap morphologies which were created with a low-energy, high-frequency femtosecond (fs) laser device. Methods: A prospective, interventional, randomized, contralateral eye, single-center comparison study was conducted from November 2019 to March 2020 at the Hamburg vision clinic/ zentrumsehstärke, Hamburg, Germany. Eleven patients and 22 eyes received low-energy fs LASIK treatment for myopia or myopic astigmatism in both eyes. Before the treatment, the eyes were randomized (one eye was treated with the 2D, the other eye with the 3D method). Results: The mean central flap thickness one month after surgery was 110.7 ± 1.6 µm (2D) and 111.2 ± 1.7 µm (3D); P = 0.365 (2D vs 3D). Flap thickness measured at 13 different points resulted in no statistically significant differences between any of the measurement points within/between both groups; demonstrating good planarity of the flap was achieved using both methods. Despite not being statistically significant, the surgeons recognized an increase in the presence of an opaque bubble layer in the 3D flap eyes during surgery and some patients reported higher, yet not statistically significant, pain scores in the 3D flap eyes during the first hours after the treatment. Overall, safety- and efficacy indices were 1.03 and 1.03, respectively. Conclusion: In this prospective, randomized, contralateral eye study, the low-energy fs laser yielded predictable lamellar flap thicknesses and geometry at one-month follow-up. Based on these results, efficacy and safety of the corresponding laser application, that is, 2D vs 3D, are equivalent.

11.
BMC Ophthalmol ; 23(1): 73, 2023 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-36809995

RESUMO

BACKGROUND: This study was to compare the outcomes of 360° intra-operative laser retinopexy (ILR) and focal laser retinopexy in treating patients with pars plans vitrectomy (PPV) for primary rhegmatogenous retinal detachment (RRD). To identify other potential risk factors for retinal re-detachment after primary PPV. METHODS: This was a retrospective cohort study. Three hundred and forty-four consecutive cases of primary rhegmatogenous retinal detachment treated with PPV were included between July 2013 and July 2018. Clinical characteristics and surgical outcomes were compared between focal laser retinopexy and additional 360° intra-operative laser retinopexy groups. Both univariate and multiple variable analysis were used to identify potential risk factors for retinal re-detachment. RESULTS: Median follow-up was 6.2 months (Q1, Q3:2.0, 17.2). As estimated with survival analysis, the 360º ILR group had the incidence of 9.74% and focal laser 19.54% at 6 months postoperatively. At 12 months postoperatively the difference was 10.78% vs. 25.21%. The difference in survival rates was significant (p = 0.0021). In multivariate Cox regression, the risk factors for retinal re-detachment were without additional 360° ILR, diabetes and macula off before the primary surgery (relatively OR = 0.456, 95%-CI [0.245-0.848], p < 0.05; OR = 2.301, 95% CI [1.130-4.687], p < 0.05; OR = 2.243, 95% CI [1.212-4.149], p < 0.05). CONCLUSION: Additional 360° ILR group had a significantly lower rate of retinal re-detachment when compared with focal laser retinopexy group. Our study also elucidated that diabetes and macular off before the primary surgery might also be the potential risk factors for higher rate of retinal re-detachment outcome. TRIAL REGISTRATION: This was a retrospective cohort study.


Assuntos
Diabetes Mellitus , Descolamento Retiniano , Perfurações Retinianas , Humanos , Descolamento Retiniano/cirurgia , Vitrectomia/efeitos adversos , Estudos Retrospectivos , Perfurações Retinianas/cirurgia , Lasers , Resultado do Tratamento , Diabetes Mellitus/etiologia
12.
J Cataract Refract Surg ; 49(3): 272-277, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36730449

RESUMO

PURPOSE: To determine and compare the prevalence of rhegmatogenous retinal detachment (RRD) in myopic eyes operated of posterior chamber phakic implantable collamer lens (ICL) with a control group of nonoperated myopic eyes over 10 years of follow-up. SETTING: Clinica Baviera, Madrid, Spain. DESIGN: Retrospective cohort study. METHODS: There were 2 study cohorts: one with patients operated with ICL and a control group of nonoperated patients. The primary outcome of RRD was measured retrospectively, first through chart review of ICL-operated patients with at least 10 years of follow-up, then secondarily through telephone questionnaires and specialist verification for those with incomplete follow-up. Prevalence and incidence were calculated and compared, as well as their possible association with other risk factors. RESULTS: 58 operated patients completed follow-up in our clinic. A survey of 3849 more patients was conducted for a total of 252 operated with a mean spherical equivalent (SEQ) of -12.6 diopters (D) and 221 nonoperated with a mean SEQ of -10.5 D. 7 eyes developed an RRD in the operated vs 5 eyes among the nonoperated (prevalence 1.71% vs 1.25%, respectively, P = .773). The equivalence tests, the two one-sided test and the null hypothesis test between groups, were within the 0.02 limits, confirming the null hypothesis, and compared survival curves did not show significant differences ( P = .59). CONCLUSIONS: ICL implantation surgery for high myopia did not affect the prevalence of RRD in operated eyes compared with similar nonoperated eyes, in this long-term study.


Assuntos
Miopia , Lentes Intraoculares Fácicas , Descolamento Retiniano , Humanos , Descolamento Retiniano/cirurgia , Estudos Retrospectivos , Prevalência , Implante de Lente Intraocular/efeitos adversos , Lentes Intraoculares Fácicas/efeitos adversos , Seguimentos , Miopia/cirurgia , Refração Ocular
13.
Front Med (Lausanne) ; 9: 854288, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35872772

RESUMO

Purpose: To investigate inner retinal hyperreflectivity on optical coherence tomography (OCT) as a potential biomarker indicating acute central retinal artery occlusion (CRAO). Methods: A total of 56 patients at two university hospitals with acute CRAO (symptom onset ≤48 h) were included in this retrospective study. The optical intensity of the inner retinal layers was determined in both eyes and the relationship between symptom onset and inner retinal layer optical intensity in OCT scans compared to the unaffected fellow eye was analyzed. Several differential diagnoses [central retinal vein occlusion, anterior ischemic optic neuropathy, diabetic macular edema, and subretinal fibrosis/disciform scar (Junius-Kuhnt)] served as controls to validate optical intensity-based diagnosis of CRAO. Results: CRAO strongly correlated with an increased inner retinal layer hyperreflectivity in this cohort with acute CRAO with a time since symptom onset ranging from 1.1 to 48.0 h. Receiver operating characteristic (ROC) analysis showed an area under the curve of 0.99 to confirm CRAO with a true positive rate of 0.93 and a false positive rate of 0.02. No correlation between optical intensity and time since symptom onset was noticeable. None of the differential diagnoses did show an elevated optical intensity of the inner retinal layers as it was detectable in CRAO. Conclusion: OCT-based determination of inner retinal layer hyperreflectivity is a very promising biomarker for a prompt diagnosis of CRAO in an emergency setting. This may be of major interest to speed up the administration of a possible thrombolytic treatment.

14.
Clin Ophthalmol ; 16: 2079-2092, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35770247

RESUMO

Purpose: To analyze the impact of postoperative ocular residual astigmatism (ORA) on refraction, visual acuity and subjective satisfaction after myopic laser-in-situ-keratomileusis (LASIK) by a comprehensive analysis, which includes clinically relevant data and patient-reported outcomes. Material and Methods: To evaluate the influence of ORA, comparison groups were built following Archer et al. Myopic patients were subdivided by the fraction ORA/MRC (matched and not matched for MRC) (MRC = manifest refractive cylinder), ORA magnitude and CA magnitude in high ORA eyes (CA = corneal astigmatism). Refractive and visual data were analyzed via retrospective cross-sectional analysis for multiple parameters. The subjective satisfaction was analyzed retrospectively 3-4 years after having LASIK via patient reported outcome analysis. Results: Refractive outcome: Only when grouped by ORA magnitude only, high ORA eyes resulted in approximately twice as cylinder magnitude compared to eyes with preoperative lower ORA. Furthermore, there appeared to be no statistically significant differences in any case. Visual outcome: There appeared to be no statistically significant differences for visual acuity parameters (safety index, efficacy index). Patient reported outcome: When grouped by the rate of ORA/MRC not matching for MRC, there were statistically significant differences in the subjective satisfaction (p = 0.006) and the postoperative side effects (p = 0.001, p = 0.01, p = 0.006), those differences appeared less strong when matched for MRC treated and result better for a higher ratio of ORA/MRC. Conclusion: Patients with postoperatively high ORA report on higher satisfaction with treatment results than patients with postoperatively low ORA. This did not correlate with differences in the refractive nor visual outcome. As a matter of fact, there is a discrepancy between the objective analysis results and the subjective satisfaction of patients.

15.
PLoS One ; 17(5): e0268377, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35594273

RESUMO

PURPOSE: An increasing number of posterior segment disorders is routinely managed with pars plana vitrectomy (PPV). In older, phakic patients cataract formation is expected within the first two years after surgery. For younger patients its progression is individually fluctuating. This study uses an objective quantitative measurement for lens-status-monitoring after PPV with silicone oil to derive predictions for progression and severity of post-operative lens opacification evaluated in patients with rhegmatogenous retinal detachment (RRD). METHODS: Data acquisition was performed prospectively between March 2018 and March 2021. PentacamHR® Nucleus Staging mode (PNS) was used to objectively gather data about nuclear cataracts after PPV at different time points. Data was grouped into training and test sets for a mathematical prediction model. Via backward variable selection method a mathematical formula was set up by means of which predictions about lens densitometry (LD) can be calculated. RESULTS: 20 males [58.8%] and 14 females [41.2%] matched the inclusion criteria (mean age 50.6 years [23-75; ±12.3]). Average follow-up was 8.1 months (3,4-17.4; ±3.4). Mean baseline LD of the treated and fellow eye before surgery was 11.1% (7.7%-17.6%; ±2.0) and 11.2% (7.7%-14.8%; ±1.5), respectively. Predicted LD values by the model for five pre-selected patients closely match the observed data with an average deviation of 1.06%. CONCLUSIONS: Using an objective parameter like LD delivered by the PentacamHR® PNS mode additionally to the patient's age allows us to make an individual prediction for any time after PPV with silicone oil due to RRD for all ages. The accuracy of the model was stronger influenced by baseline LD as cofactor in the equation than patient's age. The application for the prediction lens opacification [which can be accessed for free under the following link (https://statisticarium.com/apps/sample-apps/LensDensityOil/)] can help vitreoretinal surgeons for patient consultation on the possibility to combine PPV with cataract surgery.


Assuntos
Catarata , Descolamento Retiniano , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Descolamento Retiniano/cirurgia , Estudos Retrospectivos , Óleos de Silicone/efeitos adversos , Acuidade Visual , Vitrectomia/efeitos adversos , Vitrectomia/métodos
16.
J Refract Surg ; 38(4): 270-276, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35412921

RESUMO

PURPOSE: To evaluate safety and efficacy in the management of flap displacement after laser in situ keratomileusis (LASIK) and subsequent complications. METHODS: This was a retrospective study performed using data recorded at the center's database from October 2002 to August 2021. Efficacy and safety were both converted to binary outcomes (loss of one or more lines and no change or gain in lines of visual acuity). The effects of time from surgery to complication and from complication to repair were assessed and the odds ratios and probabilities were calculated. The same procedure was applied to investigate the effect of these temporal variables on complications. RESULTS: A total of 66 eyes with late traumatic LASIK flap displacements were studied. Efficacy remained unchanged in 48 patients (64 eyes, 75%), and safety remained unchanged in 53 patients (59 eyes, 90%). Sixty-six patients (64 eyes, 100%) achieved visual acuity values of 20/40 and 45 patients (64 eyes, 70.3%) achieved values of 20/20. The flap displacement was resolved in the first 24 hours (SD ± 0.1 days). Surgery was performed in 58 patients (65 eyes, 90%). Epithelial ingrowth was the most frequent complication. Patients who underwent surgery tended not to lose lines (P = .05). The risk of developing epithelial ingrowth increases with time after LASIK surgery until traumatic flap displacement (odds ratio: 1.001; P < .001). The prevalence of dislocation during the study period was 0.012%. CONCLUSIONS: Visual safety values were favorable after resolution of the flap complication. Immediate surgical management leads to better visual efficacy, and the time between LASIK and trauma increases the risk of epithelial ingrowth after flap displacement. [J Refract Surg. 2022;38(4):270-276.].


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Substância Própria/cirurgia , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos , Retalhos Cirúrgicos , Resultado do Tratamento
17.
J Refract Surg ; 38(4): 222-228, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35412928

RESUMO

PURPOSE: To analyze corneal aberrations and factors affecting visual outcomes after implantation of a trifocal intraocular lens (IOL) in eyes previously treated with laser corneal refractive surgery. METHODS: This retrospective case series included 222 consecutive eyes implanted with the trifocal FineVision Micro-F IOL (PhysIOL) after laser corneal refractive surgery. The series was divided into two groups according to safety outcomes after lensectomy: eyes with loss of one or more lines of corrected distance visual acuity (CDVA) [n = 59, 26.5%]) (failed eyes group) and eyes with no loss or gain in CDVA lines (n = 163, 73.4%]) (successful eyes group). Distribution of tomographic corneal aberrations (spherical aberration [Z40], comatic and root mean square of higher order aberrations [RMS-HOA]), laser corneal refractive surgery error, kappa angle, and CDVA after laser corneal refractive surgery were compared among both groups. RESULTS: Mean CDVA after lensectomy was 0.15 ± 0.07 logMAR (range: 0.05 to 0.30 logMAR) versus 0.03 ± 0.04 logMAR (range: 0.00 to 0.15 logMAR) in the failed and successful eyes groups, respectively (P < .001). Comparison of both groups showed that failed eyes had a statistically significantly higher grade of hyperopic laser corneal refractive surgery than successful eyes measured as mean sphere (+0.71 ± 3.10 diopters [D] [range: -7.75 to +6.00 D] vs -0.46 ± 3.70 D [range: -10.75 to +6.00 D], P < .01), spherical equivalent (+0.27 ± 3.10 D [range: -8.00 to +5.50 D] vs -0.97 ± 3.60 D [range: -12.50 to +4.90 D], P < .05), and percentage of hyperopic laser corneal refractive surgery (64% vs 43.5%, P < .05). Corneal aberration analysis showed that mean Z40 values were significantly more negative in the failed eyes group than in the successful eyes group (+0.07 ± 0.40 mm [range: -0.82 to +0.65 mm] vs +0.18 ± 0.37 mm [range: -0.79 to +0.87 mm], P < .05). Laser corneal refractive surgery cylinder was distributed homogeneously between both groups, as well as coma and RMS-HOA, kappa angle, and CDVA after laser corneal refractive surgery that were not statistically significant. CONCLUSIONS: Surgeons should consider tomographic corneal spherical aberration after implantation of a trifocal IOL in eyes after keratorefractive surgery, particularly in eyes previously treated with hyperopic laser corneal refractive surgery, to prevent loss of lines of visual acuity after lensectomy. [J Refract Surg. 2022:38(4):222-228.].


Assuntos
Cirurgia da Córnea a Laser , Hiperopia , Lentes Intraoculares , Humanos , Hiperopia/cirurgia , Lasers , Refração Ocular , Estudos Retrospectivos
18.
Graefes Arch Clin Exp Ophthalmol ; 260(9): 2949-2958, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35396961

RESUMO

PURPOSE: The study aims to explore the intereye asymmetry in normal and keratoconic individuals and to evaluate the discriminant power of single and combined asymmetry parameters. METHODS: This is a retrospective designed study including 414 patients who had Pentacam Scheimpflug topographic and tomographic imaging in both eyes: 124 subjects with bilateral normal corneas evaluated for refractive surgery and 290 with keratoconus. All elevation-, pachymetric-, and volumetric-based data (56 parameters) were electronically retrieved and analyzed. Intereye asymmetry was determined by subtracting the lowest value from the highest value for each variable. The degree of asymmetry between each subject's eyes was calculated with intraclass correlation coefficients for all the parameters. Receiver operating characteristic curve was used to determine predictive accuracy and to identify optimal cutoffs of these values and combinations thereof. RESULTS: In the normal/keratoconus subjects the median intereye asymmetries were 0.30/3.45 for K2 (flat) meridian, 0.03/0.25 for BFS front, 1.00/15.00 for elevation back BFS apex, and 7.00/29.00 for pachy min. CONCLUSIONS: In addition to Rabinowitz's Kmax intereye asymmetry we propose pachymetric, elevation-based, and high-order corneal wavefront intereye asymmetry parameters to improve the diagnostic armamentarium of keratoconus.


Assuntos
Ceratocone , Córnea , Paquimetria Corneana , Topografia da Córnea , Humanos , Curva ROC , Estudos Retrospectivos , Tomografia
19.
BMC Ophthalmol ; 22(1): 39, 2022 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-35086499

RESUMO

BACKGROUND: Diffractive intraocular lenses (IOLs) could affect visual acuity in patients with macular pathologies such as epiretinal membrane (ERM) and could influence the results of pars plana vitrectomy (PPV) for ERM removal in pseudophakic eyes with these IOLs. The aim of this study is to evaluate the effect on visual outcomes of a diffractive trifocal IOL in PPV for ERM peeling. METHODS: This is a retrospective cohort study on 20 eyes with a single model of trifocal IOL that underwent PPV for removal of ERM between January 2015 and September 2018 in our clinics. Follow up was at least 1 year. Primary outcome measure was mean change in visual acuity. Secondary outcome measures were mean change in central macular thickness (CMT), recovery of the external retinal layers, and change in spherical equivalent (SE). RESULTS: Mean corrected distance visual acuity (CDVA) was 0.03 ± 0.03 logMAR after phacoemulsification; this worsened to 0.23 ± 0.10 logMAR with ERM, improving to 0.10 ± 0.04 log MAR 12 months after PPV (p = 0.001). Mean uncorrected near visual acuity (UNVA) was Jaeger 2.62 ± 0.51 after lensectomy. This worsened to Jaeger 5.46 ± 1.67 with ERM and improved to the initial Jaeger 2.69 ± 0.84 after PPV (p = 0.005). CMT decreased significantly, from 380.15 ± 60.50 µm with the ERM to 313.70 ± 36.98 µm after PPV. Mean SE after lensectomy was - 0.18 ± 0.38 D, which minimally changed to - 0.18 ± 0.47 D after PPV (p = 0.99). The only complication recorded after PPV was a case of cystoid macular edema. No difficulties in visualization due to IOL design were reported during PPV. CONCLUSION: PPV for ERM in eyes with this trifocal IOL seems to be safe and effective, and allows recovery of the loss of UNVA.


Assuntos
Membrana Epirretiniana , Lentes Intraoculares , Facoemulsificação , Membrana Epirretiniana/cirurgia , Humanos , Desenho de Prótese , Estudos Retrospectivos , Vitrectomia
20.
Eye Vis (Lond) ; 8(1): 39, 2021 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-34688308

RESUMO

PURPOSE: To dynamically assess variations in pupil diameter induced by changes in brightness in myopic eyes implanted with an implantable collamer lens (ICL, STAAR Surgical) with a central port. METHODS: This prospective, observational single-center case series study comprised 65 eyes from 65 consecutive patients undergoing ICL implant. A modified commercially available swept-source Fourier-domain anterior segment optical coherence tomography (AS-OCT) device was used for imaging and performing dynamic pupillometry under changing light conditions before and after a mean follow-up interval of four months after surgery. RESULTS: Preoperative mean pupil size under photopic conditions was 3.38 ± 0.64 mm; after surgery, this increased to 3.48 ± 0.61 mm. Mean pupil size under scotopic light conditions was 5.72 ± 0.79 mm before surgery and 5.84 ± 0.77 mm postoperatively. The differences between preoperative and postoperative pupil diameter in miosis and mydriasis were 0.10 ± 0.44 mm (P = 0.078) and 0.12 ± 0.58 mm (P = 0.098), respectively. The scotopic pupil exceeded the optic zone of the implanted lens in 39 eyes (60%). The mean central vault value was 412 ± 177 µm under maximum miosis and 506 ± 190 µm under maximum mydriasis. We found a positive correlation between vault and differences in pupil diameter under all light conditions (P < 0.05). CONCLUSION: Dynamic AS-OCT enables a very precise determination of the pupillary diameter in the iris plane. The changes in the pupil diameter under different light conditions after the implantation of an ICL are related to the postoperative vault.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA