1.
Science ; 359(6378): 908-911, 2018 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-29472482

RESUMO

Ocean acidification refers to the lowering of the ocean's pH due to the uptake of anthropogenic CO2 from the atmosphere. Coral reef calcification is expected to decrease as the oceans become more acidic. Dissolving calcium carbonate (CaCO3) sands could greatly exacerbate reef loss associated with reduced calcification but is presently poorly constrained. Here we show that CaCO3 dissolution in reef sediments across five globally distributed sites is negatively correlated with the aragonite saturation state (Ωar) of overlying seawater and that CaCO3 sediment dissolution is 10-fold more sensitive to ocean acidification than coral calcification. Consequently, reef sediments globally will transition from net precipitation to net dissolution when seawater Ωar reaches 2.92 ± 0.16 (expected circa 2050 CE). Notably, some reefs are already experiencing net sediment dissolution.


Assuntos
Antozoários/crescimento & desenvolvimento , Carbonato de Cálcio/química , Recifes de Corais , Água do Mar/química , Ácidos/química , Animais , Calcificação Fisiológica , Concentração de Íons de Hidrogênio
2.
Environ Sci Technol ; 48(16): 9573-81, 2014 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-25051401

RESUMO

Total alkalinity (AT) is an important parameter for describing the marine inorganic carbon system and understanding the effects of atmospheric CO2 on the oceans. Measurements of AT are limited, however, because of the laborious process of collecting and analyzing samples. In this work we evaluate the performance of an autonomous instrument for high temporal resolution measurements of seawater AT. The Submersible Autonomous Moored Instrument for alkalinity (SAMI-alk) uses a novel tracer monitored titration method where a colorimetric pH indicator quantifies both pH and relative volumes of sample and titrant, circumventing the need for gravimetric or volumetric measurements. The SAMI-alk performance was validated in the laboratory and in situ during two field studies. Overall in situ accuracy was -2.2 ± 13.1 µmol kg(-1) (n = 86), on the basis of comparison to discrete samples. Precision on duplicate analyses of a carbonate standard was ±4.7 µmol kg(-1) (n = 22). This prototype instrument can measure in situ AT hourly for one month, limited by consumption of reagent and standard solutions.


Assuntos
Monitoramento Ambiental/instrumentação , Monitoramento Ambiental/métodos , Água do Mar/análise , Água do Mar/química , Carbono/análise , Dióxido de Carbono/análise , Colorimetria/métodos , Havaí , Concentração de Íons de Hidrogênio , Oceanos e Mares , Oregon , Reprodutibilidade dos Testes