Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 131
Filtrar
1.
Diagnostics (Basel) ; 13(21)2023 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-37958272

RESUMO

BACKGROUND: To describe longitudinal changes in patients with non-paraneoplastic autoimmune retinopathy (npAIR) by utilizing different diagnostic modalities/tests. METHODS: The index study is a retrospective longitudinal review of sixteen eyes of eight patients from a tertiary care eye hospital diagnosed with npAIR. Multiple diagnostic modalities such as wide-angle fundus photography (WAFP), WA fundus autofluorescence (WAFAF), spectral-domain optical coherence tomography (SD-OCT), Goldmann visual field (GVF) perimetry, microperimetry (MP), electrophysiologic testing, and adaptive optics scanning laser ophthalmoscopy (AOSLO) were reviewed and analyzed. RESULTS: At the baseline visits, anomalies were detected by multimodal diagnostic tests on all patients. Subjects were followed up for a median duration of 11.5 [3.0-18.7] months. Structural changes at the baseline were detected in 14 of 16 (87.5%) eyes on WAFP and WAFAF and 13 of 16 (81.2%) eyes on SD-OCT. Eight of the ten (80%) eyes that underwent AOSLO imaging depicted structural changes. Functional changes were detected in 14 of 16 (87.5%) eyes on GVF, 15 of 16 (93.7%) eyes on MP, and 11 of 16 (68.7%) eyes on full-field electroretinogram (ff-ERG). Multifocal electroretinogram (mf-ERG) and visual evoked potential (VEP) tests were performed in 14 eyes, of which 12 (85.7%) and 14 (100%) of the eyes demonstrated functional abnormalities, respectively, at baseline. Compared to all the other structural diagnostic tools, AOSLO had a better ability to demonstrate deterioration in retinal microstructures occurring at follow-ups. Functional deterioration at follow-up was detected on GVF in 8 of 10 (80%) eyes, mf-ERG in 4 of 8 (50%) eyes, and MP in 7 of 16 (43.7%) eyes. The ff-ERG and VEP were stable in the majority of cases at follow-up. CONCLUSIONS: The utilization of multimodal imaging/tests in the diagnosing and monitoring of npAIR patients can aid in identifying anomalous changes over time. Analysis of both the anatomical and functional aspects by these devices can be supportive of detecting the changes early in such patients. AOSLO shows promise as it enables the capture of high-resolution images demonstrating quantifiable changes to retinal microstructure.

2.
Opt Express ; 31(26): 44199-44211, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-38178497

RESUMO

Images captured with resonant scanners are affected by angular velocity fluctuations that result in image distortion and by poor synchronization between scanning and light detection that creates jitter between image rows. We previously demonstrated that both problems can be mitigated in post-processing by recording the scanner orientation in synchrony with the image capture, followed by data resampling [Opt. Express30, 112 (2022)10.1364/OE.446162]. Here we introduce more robust algorithms for estimation of both angular velocity fluctuation and jitter in the presence of random and deterministic noise. We also show linearization of the scanner oscillation model to reduce calculation times by two orders of magnitude, reaching 65,000 jitter estimations per second when using 2,800 samples per image row, and 500,000 when using only 500 samples, easily supporting real-time generation of jitter-corrected images.

3.
Ophthalmol Sci ; 2(4): 100196, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36531581

RESUMO

Purpose: Clinical OCT angiography (OCTA) of the retinal microvasculature offers a quantitative correlate to systemic disease burden and treatment efficacy in sickle cell disease (SCD). The purpose of this study was to use the higher resolution of adaptive optics scanning light ophthalmoscopy (AOSLO) to elucidate OCTA features of parafoveal microvascular compromise identified in SCD patients. Design: Case series of 11 SCD patients and 1 unaffected control. Participants: A total of 11 eyes of 11 SCD patients (mean age, 33 years; range, 23-44; 8 female, 3 male) and 1 eye of a 34-year-old unaffected control. Methods: Ten sequential 3 × 3 mm parafoveal OCTA full vascular slab scans were obtained per eye using a commercial spectral domain OCT system (Avanti RTVue-XR; Optovue). These were used to identify areas of compromised perfusion near the foveal avascular zone (FAZ), designated as regions of interest (ROIs). Immediately thereafter, AOSLO imaging was performed on these ROIs to examine the cellular details of abnormal perfusion. Each participant was imaged at a single cross-sectional time point. Additionally, 2 of the SCD patients were imaged prospectively 2 months after initial imaging to study compromised capillary segments across time and with treatment. Main Outcome Measures: Detection and characterization of parafoveal perfusion abnormalities identified using OCTA and resolved using AOSLO imaging. Results: We found evidence of abnormal blood flow on OCTA and AOSLO imaging among all 11 SCD patients with diverse systemic and ocular histories. Adaptive optics scanning light ophthalmoscopy imaging revealed a spectrum of phenomena, including capillaries with intermittent blood flow, blood cell stasis, and sites of thrombus formation. Adaptive optics scanning light ophthalmoscopy imaging was able to resolve single sickled red blood cells, rouleaux formations, and blood cell-vessel wall interactions. OCT angiography and AOSLO imaging were sensitive enough to document improved retinal perfusion in an SCD patient 2 months after initiation of oral hydroxyurea therapy. Conclusions: Adaptive optics scanning light ophthalmoscopy imaging was able to reveal the cellular details of perfusion abnormalities detected using clinical OCTA. The synergy between these clinical and laboratory imaging modalities presents a promising avenue in the management of SCD through the development of noninvasive ocular biomarkers to prognosticate progression and measure the response to systemic treatment.

4.
Commun Biol ; 5(1): 893, 2022 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-36100689

RESUMO

Choroideremia is an X-linked, blinding retinal degeneration with progressive loss of photoreceptors, retinal pigment epithelial (RPE) cells, and choriocapillaris. To study the extent to which these layers are disrupted in affected males and female carriers, we performed multimodal adaptive optics imaging to better visualize the in vivo pathogenesis of choroideremia in the living human eye. We demonstrate the presence of subclinical, widespread enlarged RPE cells present in all subjects imaged. In the fovea, the last area to be affected in choroideremia, we found greater disruption to the RPE than to either the photoreceptor or choriocapillaris layers. The unexpected finding of patches of photoreceptors that were fluorescently-labeled, but structurally and functionally normal, suggests that the RPE blood barrier function may be altered in choroideremia. Finally, we introduce a strategy for detecting enlarged cells using conventional ophthalmic imaging instrumentation. These findings establish that there is subclinical polymegathism of RPE cells in choroideremia.


Assuntos
Coroideremia , Degeneração Retiniana , Corioide/diagnóstico por imagem , Coroideremia/genética , Coroideremia/patologia , Feminino , Humanos , Masculino , Óptica e Fotônica , Células Fotorreceptoras Retinianas Cones , Degeneração Retiniana/patologia
5.
Biomed Opt Express ; 13(7): 3786-3808, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35991930

RESUMO

Retinal magnification factors (RMFs) allow the conversion of angles to lengths in retinal images. In this work, we propose paraxial and non-paraxial RMF calculation methods that incorporate the individual topography and separation of the anterior and posterior surfaces of the cornea and crystalline lens, assuming homogeneous ocular media. Across 34 eyes, the two RMF methods differ by 0.1% on average, due to surface tilt, decenter, and lack of rotational symmetry in the non-paraxial modeling, which results in up to 2.2% RMF variation with retinal meridian. Differences with widely used individualized RMF calculation methods are smallest for eyes with ∼24 mm axial length, and as large as 7.5% in a 29.7 mm long eye (15D myope). To better model the capture of retinal images, we propose the tracing of chief rays, instead of the scaling of posterior nodal or principal distances often used in RMF definitions. We also report that RMF scale change is approximately proportional to both refractive error and axial separation between the ophthalmoscope's exit pupil and the eye's entrance pupil, resulting in RMF changes as large as 13% for a 1cm displacement in a 15D myopic eye. Our biometry data shows weak correlation and statistical significance between surface radii and refractive error, as well as axial length, whether considering all eyes in the study, or just the high myopes, defined as those with refractive error sphere equivalent ≤ -4D. In contrast, vitreous thicknesses show a strong correlation (r ≤ -0.92) and significance (p ≤ 10-13) with refractive error when considering all eyes or just high myopes (r ≤ -0.95; p ≤ 10-5). We also found that potential RMF change with depth of cycloplegia and/or residual accommodation is smaller than 0.2%. Finally, we propose the reporting of individual ocular biometry data and a detailed RMF calculation method description in scientific publications to facilitate the comparison of retinal imaging biomarker data across studies.

6.
Invest Ophthalmol Vis Sci ; 63(8): 27, 2022 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-35900727

RESUMO

Purpose: To assess the structure of cone photoreceptors and retinal pigment epithelial (RPE) cells in vitelliform macular dystrophy (VMD) arising from various genetic etiologies. Methods: Multimodal adaptive optics (AO) imaging was performed in 11 patients with VMD using a custom-assembled instrument. Non-confocal split detection and AO-enhanced indocyanine green were used to visualize the cone photoreceptor and RPE mosaics, respectively. Cone and RPE densities were measured and compared across BEST1-, PRPH2-, IMPG1-, and IMPG2-related VMD. Results: Within macular lesions associated with VMD, both cone and RPE densities were reduced below normal, to 37% of normal cone density (eccentricity 0.2 mm) and to 8.4% of normal RPE density (eccentricity 0.5 mm). Outside of lesions, cone and RPE densities were slightly reduced (both to 92% of normal values), but with high degree of variability in the individual measurements. Comparison of juxtalesional cone and RPE measurements (<1 mm from the lesion edge) revealed significant differences in RPE density across the four genes (P < 0.05). Overall, cones were affected to a greater extent than RPE in patients with IMPG1 and IMPG2 pathogenic variants, but RPE was affected more than cones in BEST1 and PRPH2 VMD. This trend was observed even in contralateral eyes from a subset of five patients who presented with macular lesions in only one eye. Conclusions: Assessment of cones and RPE in retinal locations outside of the macular lesions reveals a pattern of cone and RPE disruption that appears to be gene dependent in VMD. These findings provide insight into the cellular pathogenesis of disease in VMD.


Assuntos
Distrofia Macular Viteliforme , Bestrofinas/genética , Proteínas da Matriz Extracelular/genética , Proteínas do Olho/química , Proteínas do Olho/genética , Humanos , Óptica e Fotônica , Proteoglicanas/genética , Células Fotorreceptoras Retinianas Cones/patologia , Epitélio Pigmentado da Retina/patologia , Tomografia de Coerência Óptica/métodos , Distrofia Macular Viteliforme/diagnóstico , Distrofia Macular Viteliforme/genética
7.
Am J Ophthalmol Case Rep ; 27: 101660, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35880207

RESUMO

Purpose: To describe the reflectance adaptive optics scanning laser ophthalmoscopy (AOSLO) findings in different stages of Vogt-Koyanagi-Harada (VKH) disease and correlate them to visual gain post treatment. Confocal (cAOSLO) and non-confocal split-detector AOSLO (sdAOSLO) were used to assess longitudinally the status of the photoreceptors in a patient with VKH managed on corticosteroid and immunomodulatory therapy. Observation: A 32-year-old Japanese American female presented with a 2-week history of blurred vision in both eyes (OU) and worsening headache previously diagnosed as a case of VKH and treated with high dose oral prednisone. At the time of presentation, though vision was improving, and frank serous retinal detachments were absent, spectral domain optical coherence tomography (SD-OCT) showed presence of residual subretinal fluid with disruption of the photoreceptor inner segments and outer segments (IS/OS) involving OU. The photoreceptor mosaic at the foveal center appeared very sparse with large areas devoid of visible photoreceptors on cAOSLO, in agreement with the SD-OCT data. sdAOSLO imaging over the same location shows a higher number of contiguous photoreceptors. After imaging, the patient was started on mycophenolate mofetil as steroid-sparing long-term therapy. Three months later, visual acuity improved to 20/20 OU, and SD-OCT showed almost complete resolution of subretinal fluid with significant improvement of the IS/OS SD-OCT signal, OU. cAOSLO imaging revealed a contiguous photoreceptor mosaic without gaps and of normal appearance. Conclusions and Importance: VKH patients may demonstrate transient photoreceptor abnormalities on SD-OCT and cAOSLO imaging. sdAOSLO imaging revealed intact photoreceptor segments in areas that appeared as voids on cAOSLO, which later showed structural recovery on SD-OCT and cAOSLO. Therefore, sdAOSLO may predict potential for improvement in patients wherein there appears to be photoreceptor loss in cAOSLO and/or SD-OCT.

8.
Biomed Opt Express ; 13(3): 1755-1773, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35414987

RESUMO

Vitreous cortex hyalocytes are resident macrophage cells that help maintain the transparency of the media, provide immunosurveillance, and respond to tissue injury and inflammation. In this study, we demonstrate the use of non-confocal quadrant-detection adaptive optics scanning light ophthalmoscopy (AOSLO) to non-invasively visualize the movement and morphological changes of the hyalocyte cell bodies and processes over 1-2 hour periods in the living human eye. The average velocity of the cells 0.52 ± 0.76 µm/min when sampled every 5 minutes and 0.23 ± 0.29 µm/min when sampled every 30 minutes, suggesting that the hyalocytes move in quick bursts. Understanding the behavior of these cells under normal physiological conditions may lead to their use as biomarkers or suitable targets for therapy in eye diseases such as diabetic retinopathy, preretinal fibrosis and glaucoma.

9.
Opt Express ; 30(1): 112-124, 2022 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-35201185

RESUMO

Optical scanners are widely used in high-resolution scientific, medical, and industrial devices. The accuracy and precision of these instruments are often limited by angular speed fluctuations due to rotational inertia and by poor synchronization between scanning and light detection, respectively. Here we demonstrate that both problems can be mitigated by recording scanner orientation in synchrony with light detection, followed by data resampling. This approach is illustrated with synthetic and experimental data from a point-scanning microscope with a resonant scanner and a non-resonant scanner. Fitting of the resonant scanner orientation data to a cosine model was used to correct image warping and sampling jitter, as well as to precisely interleave image lines collected during the clockwise and counterclockwise resonant scanner portions of the rotation cycle. Vertical scanner orientation data interpolation was used to correct image distortion due to angular speed fluctuations following abrupt control signal changes.

10.
Biomed Opt Express ; 12(10): 6496-6513, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34745752

RESUMO

An off-axis monocular pupil tracker designed for eventual integration in ophthalmoscopes for eye movement stabilization is described and demonstrated. The instrument consists of light-emitting diodes, a camera, a field-programmable gate array (FPGA) and a central processing unit (CPU). The raw camera image undergoes background subtraction, field-flattening, 1-dimensional low-pass filtering, thresholding and robust pupil edge detection on an FPGA pixel stream, followed by least-squares fitting of the pupil edge pixel coordinates to an ellipse in the CPU. Experimental data suggest that the proposed algorithms require raw images with a minimum of ∼32 gray levels to achieve sub-pixel pupil center accuracy. Tests with two different cameras operating at 575, 1250 and 5400 frames per second trained on a model pupil achieved 0.5-1.5 µm pupil center estimation precision with 0.6-2.1 ms combined image download, FPGA and CPU processing latency. Pupil tracking data from a fixating human subject show that the tracker operation only requires the adjustment of a single parameter, namely an image intensity threshold. The latency of the proposed pupil tracker is limited by camera download time (latency) and sensitivity (precision).

11.
Optica ; 8(3): 333-343, 2021 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-34504903

RESUMO

Adaptive optics scanning light ophthalmoscopy (AOSLO) allows non-invasive visualization of the living human eye at the microscopic scale; but even with correction of the ocular wavefront aberrations over a large pupil, the smallest cells in the photoreceptor mosaic cannot always be resolved. Here, we synergistically combine annular pupil illumination with sub-Airy disk confocal detection to demonstrate a 33% improvement in transverse resolution (from 2.36 to 1.58 µm) and a 13% axial resolution enhancement (from 37 to 32 µm), an important step towards the study of the complete photoreceptor mosaic in heath and disease. Interestingly, annular pupil illumination also enhanced the visualization of the photoreceptor mosaic in non-confocal detection schemes such as split detection AOSLO, providing a strategy for enhanced multimodal imaging of the cone and rod photoreceptor mosaic.

12.
Invest Ophthalmol Vis Sci ; 62(12): 27, 2021 09 02.
Artigo em Inglês | MEDLINE | ID: mdl-34581726

RESUMO

Purpose: To characterize scattering and hyperreflective features in the foveal avascular zone of people with multiple sclerosis (MS) using adaptive optics scanning laser ophthalmoscopy (AOSLO) and to evaluate their relationship with visual function and MS disease characteristics. Methods: Twenty subjects with MS underwent confocal reflectance and non-confocal split-detection AOSLO foveal imaging. Peripapillary retinal nerve fiber layer thickness was measured using optic nerve optical coherence tomography. Blood pressure, intraocular pressure (IOP), and best-corrected high-contrast visual acuity (HCVA) and low-contrast visual acuity (LCVA) were measured. AOSLO images were graded to determine the presence and characteristics of distinct structures. Results: Two distinct structures were seen in the avascular zone of the foveal pit. Hyperreflective puncta, present in 74% of eyes, were associated with IOP and blood pressure. Scattering features, observed in 58% of eyes, were associated with decreased HCVA and LCVA, as well as increased MS duration and disability, but were not associated with retinal nerve fiber layer thickness. Hyperreflective puncta and scattering features were simultaneously present in 53% of eyes. Conclusions: Hyperreflective puncta were associated with parameters affecting ophthalmic perfusion, but they were not associated with MS disease parameters. Scattering features were associated with parameters corresponding to advanced MS, suggesting that they may be related to disease progression. Scattering features were also correlated with reduced visual function independent from ganglion cell injury, suggesting the possibility of a novel ganglion cell-independent mechanism of impaired vision in people with MS.


Assuntos
Fóvea Central/patologia , Esclerose Múltipla/diagnóstico , Doenças Retinianas/diagnóstico , Transtornos da Visão/diagnóstico , Adulto , Idoso , Feminino , Fóvea Central/diagnóstico por imagem , Humanos , Masculino , Microscopia Confocal , Pessoa de Meia-Idade , Oftalmoscopia/métodos , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia
13.
Am J Ophthalmol Case Rep ; 22: 101090, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33981912

RESUMO

PURPOSE: Fundus albipunctatus is an inherited cause of congenital stationary night blindness. The objective of this report is to describe structural changes occurring in a macular phenotype of a novel RDH5 mutation producing fundus albipunctatus using high-resolution in vivo imaging. A 62-year-old male with longstanding night blindness underwent imaging and genetic evaluation. High-resolution images of the photoreceptor mosaic were compared to those of a healthy subject. Results of a comprehensive ophthalmic evaluation and genetic testing with imaging including fundus photography, spectral-domain optical coherence tomography (OCT), fluorescein angiography (FA), OCT angiography (OCT-A), and adaptive optics scanning light ophthalmoscopy (AOSLO) are described. OBSERVATIONS: The patient presented with visual acuity of 20/25 in both eyes and longstanding poor dark adaptation. Anterior segment examination was unremarkable. Fundoscopy revealed well circumscribed bilateral perifoveal mottling and atrophy in both eyes. Discrete white-yellow flecks were present beyond the vascular arcades extending to the far periphery. Genetic testing revealed a novel compound heterozygous RDH5 mutation (c.388C > T, p.Gln130*; c.665T > C, p.Leu222Pro). OCT demonstrated perifoveal photoreceptor and outer retinal irregularities, which corresponded to a window defect with late staining on FA. OCT-A demonstrated normal retinal vasculature with patchy areas of non-perfusion in the choriocapillaris. Macular abnormalities in both eyes were imaged using AOSLO to assess cone and rod photoreceptor architecture. While clinical features are consistent with a primary rod disorder, confocal AOSLO showed a paucity of normal cones with a small spared central island in both eyes. Rods appeared larger and more irregular throughout the macula. Non-confocal split detection AOSLO imaging revealed the presence of cone inner segments in dark regions of confocal imaging, indicating some degree of photoreceptor preservation. CONCLUSIONS AND IMPORTANCE: The AOSLO imaging of this particular macular phenotype of fundus albipunctatus demonstrates some of the structural photoreceptor abnormalities that occur in this condition, adding insight to the variable presentation of RDH5 retinopathy. The presence of preserved inner segment architecture suggests the possibility that gene therapy could play a future role in treating this condition.

14.
Biomed Opt Express ; 12(3): 1449-1466, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33796365

RESUMO

In vivo imaging of human retinal pigment epithelial (RPE) cells has been demonstrated through multiple adaptive optics (AO)-based modalities. However, whether consistent and complete information regarding the cellular structure of the RPE mosaic is obtained across these modalities remains uncertain due to limited comparisons performed in the same eye. Here, an imaging platform combining multimodal AO-scanning light ophthalmoscopy (AO-SLO) with AO-optical coherence tomography (AO-OCT) is developed to make a side-by-side comparison of the same RPE cells imaged across four modalities: AO-darkfield, AO-enhanced indocyanine green (AO-ICG), AO-infrared autofluorescence (AO-IRAF), and AO-OCT. Co-registered images were acquired in five subjects, including one patient with choroideremia. Multimodal imaging provided multiple perspectives of the RPE mosaic that were used to explore variations in RPE cell contrast in a subject-, location-, and even cell-dependent manner. Estimated cell-to-cell spacing and density were found to be consistent both across modalities and with normative data. Multimodal images from a patient with choroideremia illustrate the benefit of using multiple modalities to infer the cellular structure of the RPE mosaic in an affected eye, in which disruptions to the RPE mosaic may locally alter the signal strength, visibility of individual RPE cells, or even source of contrast in unpredictable ways.

15.
Opt Express ; 29(7): 10346-10363, 2021 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-33820171

RESUMO

The rapid oscillation of galvanometric resonant optical scanners introduces linear astigmatism that degrades transverse resolution, and in confocal systems, also reduces signal [V. Akondi et al., Optica 7, 1506, 2020]. Here, we demonstrate correction of this aberration by tilting reflective or refractive optical elements for a single vergence or a vergence range, with and without the use of an adaptive wavefront corrector such as a deformable mirror. The approach, based on nodal aberration theory, can generate any desired third order aberration that results from tilting or decentering optical surfaces.

16.
Opt Express ; 29(6): 8417-8429, 2021 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-33820289

RESUMO

The widely used lenslet-bound definition of the Shack-Hartmann wavefront sensor (SHWS) dynamic range is based on the permanent association between groups of pixels and individual lenslets. Here, we formalize an alternative definition that we term optical dynamic range, based on avoiding the overlap of lenslet images. The comparison of both definitions for Zernike polynomials up to the third order plus spherical aberration shows that the optical dynamic range is larger by a factor proportional to the number of lenslets across the SHWS pupil. Finally, a pre-centroiding algorithm to facilitate lenslet image location in the presence of defocus and astigmatism is proposed. This approach, based on the SHWS image periodicity, is demonstrated using optometric lenses that translate lenslet images outside the projected lenslet boundaries.

17.
Front Aging Neurosci ; 13: 629214, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33767618

RESUMO

Dark cone photoreceptors, defined as those with diminished or absent reflectivity when observed with adaptive optics (AO) ophthalmoscopy, are increasingly reported in retinal disorders. However, their structural and functional impact remain unclear. Here, we report a 3-year longitudinal study on a patient with oligocone trichromacy (OT) who presented with persistent, widespread dark cones within and near the macula. Diminished electroretinogram (ERG) cone but normal ERG rod responses together with normal color vision confirmed the OT diagnosis. In addition, the patient had normal to near normal visual acuity and retinal sensitivity. Occasional dark gaps in the photoreceptor layer were observed on optical coherence tomography, in agreement with reflectance AO scanning light ophthalmoscopy, which revealed that over 50% of the cones in the fovea were dark, increasing to 74% at 10° eccentricity. In addition, the cone density was 78% lower than normal histologic value at the fovea, and 20-40% lower at eccentricities of 5-15°. Interestingly, color vision testing was near normal at locations where cones were predominantly dark. These findings illustrate how a retina with predominant dark cones that persist over at least 3 years can support near normal central retinal function. Furthermore, this study adds to the growing evidence that cones can continue to survive under non-ideal conditions.

18.
Biomed Opt Express ; 12(2): 737-755, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33680539

RESUMO

Quadrant reflectance confocal and non-confocal scanning light ophthalmoscope images of the photoreceptor mosaic were recorded in a subject with congenital achromatopsia (ACHM) and a normal control. These images, captured with various circular and annular apertures, were used to calculate split-detection images, revealing two cone photoreceptor contrast mechanisms. The first contrast mechanism, maximal in the non-confocal 5.5-10 Airy disk diameter annular region, is unrelated to the cone reflectivity in confocal or flood illumination imaging. The second mechanism, maximal for confocal split-detection, is related to the cone reflectivity in confocal or flood illumination imaging that originates from the ellipsoid zone and/or inner-outer segment junction. Seeking to maximize image contrast, split-detection images were generated using various quadrant detector combinations, with opposite (diagonal) quadrant detectors producing the highest contrast. Split-detection generated with the addition of adjacent quadrant detector pairs, shows lower contrast, while azimuthal split-detection images, calculated from adjacent quadrant detectors, showed the lowest contrast. Finally, the integration of image pairs with orthogonal split directions was used to produce images in which the photoreceptor contrast does not change with direction.

19.
Biomed Opt Express ; 12(1): 409-432, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33520390

RESUMO

The Shack-Hartmann wavefront sensor (SHWS) is often operated under the assumption that the sensed light can be described by a single wavefront. In biological tissues and other multi-layered samples, secondary wavefronts from axially and/or transversely displaced regions can lead to artifactual aberrations. Here, we evaluate these artifactual aberrations in a simulated ophthalmic SHWS by modeling the beacons that would be generated by a two-layer retina in human and mouse eyes. Then, we propose formulae for calculating a minimum SHWS centroid integration area to mitigate these aberrations by an order of magnitude, potentially benefiting SHWS-based metrology and adaptive optics systems such as those used for retinal imaging and microscopy.

20.
Appl Opt ; 60(36): 11189-11195, 2021 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-35201107

RESUMO

Dynamic mirror deformation can substantially degrade the performance of optical instruments using resonant scanners. Here, we evaluate two scanners with resonant frequencies >12kHz with low dynamic distortion. First, we tested an existing galvanometric motor with a novel, to the best of our knowledge, mirror substrate material, silicon carbide, which resonates at 13.8 kHz. This material is stiffer than conventional optical glasses and has lower manufacturing toxicity than beryllium, the stiffest material currently used for this application. Then, we tested a biaxial microelectromechanical (MEMS) scanner with the resonant axis operating at 29.4 kHz. Dynamic deformation measurements show that wavefront aberrations in the galvanometric scanner are dominated by linear oblique astigmatism (90%), while wavefront aberrations in the MEMS scanner are dominated by horizontal coma (30%) and oblique trefoil (27%). In both scanners, distortion amplitude increases linearly with deflection angle, yielding diffraction-limited performance over half of the maximum possible deflection for wavelengths longer than 450 nm and over the full deflection range for wavelengths above 850 nm. Diffraction-limited performance for shorter wavelengths or over larger fractions of the deflection range can be achieved by reducing the beam diameter at the mirror surface. The small dynamic distortion of the MEMS scanner offers a promising alternative to galvanometric resonant scanners with desirable but currently unattainably high resonant frequencies.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA