Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Cardiothorac Surg ; 11(1): 89, 2016 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-27245321

RESUMO

BACKGROUND: External wrapping is a surgical technique used in patients with dilated ascending aorta. To date, there is no available data describing the radiographic features of the aorta subjected to external wrapping using a straight corrugated Dacron vascular prosthesis. The aim of this study was to find distinctive radiographic features of an externally constricted aorta. METHODS: Preoperative and early postoperative (7th postoperative day) CT angiography images of ten patients who underwent wrapping procedures were assessed and compared. The images were analyzed in order to find characteristic features of CT angiography images of the ascending aorta subjected to external wrapping. RESULTS: The CT-angiography images showed that the aortic wall deformed significantly (the wall plicated) after the wrapping procedure in one patient, whose aortic diameter was decreased by 47 %. The remaining nine patients did not have significant aortic wall deformations. All patients presented with a periaortic mass. This was a collection of blood clots and pericardial fluid that filled the empty space in the pericardium following a decrease in the diameter of the ascending aorta. A very thin (<1 mm) crescent-shaped uncontrasted layer was noticed between the aorta and the periaortic area in all patients. This, in turn, was an empty space between the aorta and the corrugated vascular prosthesis. CONCLUSIONS: The CT-angiography images of the aorta subjected to external wrapping may have unique features that are not observed after other operations on the ascending aorta. The knowledge about the details of this surgical procedure helps to correctly assess these images.


Assuntos
Aneurisma da Aorta Torácica/diagnóstico por imagem , Prótese Vascular , Angiografia por Tomografia Computadorizada , Idoso , Aneurisma da Aorta Torácica/cirurgia , Feminino , Humanos , Masculino , Polietilenotereftalatos , Período Pós-Operatório , Resultado do Tratamento
3.
J Cardiothorac Surg ; 10: 168, 2015 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-26589143

RESUMO

BACKGROUND: External wrapping is a surgical technique performed in patients with a dilated ascending aorta. The aim of this study is to present the mid-term results of wrapping of the dilated ascending aorta. METHODS: 34 patients (mean age: 64.4 ± 10.8 years, 21 males) with a dilated ascending aorta were operated on at a single cardiac surgery center using a wrapping technique. The aortas were wrapped with 32-36 mm straight Dacron vascular prostheses. The aortic wall was not excised in any of the patients. Wrapping was performed concomitant to other cardiac surgery procedures in 30 patients (88 %), which involved surgery on the aortic valve in 28 patients (82 %). RESULTS: The mean follow-up time was 19.5 ± 8.3 months (median: 18 months, range: 12-36 months). None of the patients died or had aortic complications during the hospital stay and the follow-up period. A rethoracotomy had to be performed due to excessive postoperative bleeding in two patients. One patient was diagnosed with a transient ischemic attack on the 4th postoperative day, while another had respiratory failure requiring prolonged intubation. No redilatation of the ascending aorta or dislocation of the wrap was noticed in any of the patients. CONCLUSIONS: According to our study, external wrapping of the ascending aorta has good short-term results and may be regarded as a safe surgical option for patients with a moderately dilated ascending aorta.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Resultado do Tratamento
4.
J Cardiothorac Surg ; 10: 106, 2015 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-26231405

RESUMO

BACKGROUND: External wrapping is a surgical method performed to prevent the dilatation of the aorta and to decrease the risk of its dissection and rupture. However, it is also believed to cause degeneration of the aortic wall. A biomechanical analysis was thus performed to assess the stress of the aortic wall subjected to external wrapping. METHODS: A stress analysis using the finite elements method was carried out on three models: a non-dilated aorta, a moderately dilated aorta and a wrapped aorta. The models were subjected to a pulsatile flow (120/80 mmHg) and a systolic aortic annulus motion of 11 mm. RESULTS: The finite elements analysis showed that the stress exerted on the outer surface of the ascending aorta in the wrapping model (0.05-0.8 MPa) was similar to that observed in the normal aorta (0.03-0.7 MPa) and was lower than in the model of a moderately dilated aorta (0.06-1.4 MPa). The stress on the inner surface of the ascending aorta ranged from 0.2 MPa to 0.4 MPa in the model of the normal aorta, from 0.3 to 1.3 MPa in the model of the dilated aorta and from 0.05 MPa to 0.4 MPa in the wrapping model. CONCLUSIONS: The results of this study suggest that the aortic wall is subjected to similar stress following a wrapping procedure to the one present in the normal aorta.


Assuntos
Aorta/fisiopatologia , Aneurisma da Aorta Torácica/fisiopatologia , Simulação por Computador , Fenômenos Biomecânicos , Humanos
5.
Ann Thorac Surg ; 99(4): 1464-6, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25841843

RESUMO

We present our preliminary experience with beating-heart aortic root remodeling using an external "corset," which we performed in 2 patients with aortic insufficiency and aortic root dilatation. Standard extracorporeal circulation (ECC) was used. After a meticulous dissection of the aortic root and ascending aorta, the bespoke vascular prosthesis was placed around the vessel to decrease its diameter and restore aortic valve function. Postoperative angiographic computed tomography (CT) showed a significant decrease in the diameter of the wrapped aorta. Echocardiography performed 12 months after the operation showed normal aortic valve function with trivial regurgitation and stable aortic diameter in both patients.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Circulação Extracorpórea/métodos , Idoso , Angiografia/métodos , Insuficiência da Valva Aórtica/diagnóstico por imagem , Ecocardiografia Doppler , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco , Estudos de Amostragem , Esternotomia/métodos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
6.
Kardiochir Torakochirurgia Pol ; 11(2): 216-9, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26336425

RESUMO

A 24-year-old pregnant woman (29.4 weeks of gestation) with A (H1N1) influenza-associated adult respiratory distress syndrome was admitted to the intensive care unit. The patient was connected to femoral-jugular veno-venous extracorporeal membrane oxygenation (ECMO) 8 hours after admission. On the 7(th) day of ECMO support, due to the increasing threat to the life of the mother and the fetus, a decision was made to carry out a cesarean section (CS) without discontinuing the ECMO support. The CS was performed uneventfully under general anesthesia, 5 hours after the discontinuation of heparin infusion. A live, premature 1200 g female neonate was delivered. No complications occurred in the perioperative period. On the 17(th) day, the patient was successfully weaned off the ECMO and discharged 10 days later. The newborn was discharged from the hospital in good health 41 days after the delivery.

7.
Kardiol Pol ; 68(10): 1150-3; discussion 1153, 2010 Oct.
Artigo em Polonês | MEDLINE | ID: mdl-20967713

RESUMO

A case of a 58 year-old male with renal failure and recurrent cardiac tamponade is presented. In spite of extensive work-up, aetiology of pericardial effusion remained unknown. Diagnostic difficulties in this setting are discussed.


Assuntos
Tamponamento Cardíaco/complicações , Tamponamento Cardíaco/diagnóstico , Falência Renal Crônica/complicações , Falência Renal Crônica/diagnóstico , Derrame Pericárdico/complicações , Derrame Pericárdico/diagnóstico , Tamponamento Cardíaco/terapia , Humanos , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Derrame Pericárdico/terapia , Recidiva , Diálise Renal
8.
Folia Histochem Cytobiol ; 48(2): 202-7, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20675275

RESUMO

Oxidative stress markers and apoptosis were estimated during elective surgical heart revascularization. Eight patients with good ejection fraction underwent coronary artery bypass grafting (CABG) with the use of warm blood cardioplegia. Two right atrium auricle biopsy specimens were collected before and after the operation. Specimens underwent immunocytochemical analysis of mitochondrial manganese superoxide dismutase (MnSOD) expression and apoptosis estimation by the TUNEL method. Ultrastructure analysis under electron microscope was made. Satisfactory results of the operation were obtained. After CABG the MnSOD expression increase in sections of auricles was observed through the increase of stain intensity and the percentage of cells with positive stain (from 30 to 80%). The apoptotic cells percentage remained at approximately the same level. Under the electron microscope insignificant pathological changes were observed. On this basis one may assume that in the case of cardiosurgical procedures with short aorta cross-clamping time and low operation risk level the application of cardioplegia sufficiently prevents reactive oxygen forms (ROF) cytotoxic activity although it does not inhibit the expression of oxidative stress (OS) markers. In our opinion the method of examining right atrium sections is safe and provides results comparable with other publications. It may also be a voice in the discussion on new methods of heart protection during cardiac surgery procedures.


Assuntos
Apoptose/fisiologia , Apêndice Atrial , Biomarcadores/metabolismo , Parada Cardíaca Induzida/métodos , Átrios do Coração , Revascularização Miocárdica/métodos , Miócitos Cardíacos/metabolismo , Estresse Oxidativo , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/citologia , Apêndice Atrial/metabolismo , Apêndice Atrial/cirurgia , Soluções Cardioplégicas/metabolismo , Ponte de Artéria Coronária/métodos , Feminino , Átrios do Coração/citologia , Átrios do Coração/metabolismo , Átrios do Coração/cirurgia , Humanos , Marcação In Situ das Extremidades Cortadas , Masculino , Pessoa de Meia-Idade , Miócitos Cardíacos/ultraestrutura , Superóxido Dismutase/metabolismo
9.
In Vivo ; 21(5): 785-9, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18019412

RESUMO

The aim of this study was to evaluate the influence of pressure applied while assessing the graft's tightness on the expression of adhesion molecules. Another goal was to find a correlation between the type of fluid (heparynized blood or saline) used during preparation of the conduit and the expression of the adhesion molecules. Saphenous vein fragments were obtained from 48 patients who had undergone coronary artery surgery. Expression of the following particles was evaluated: CD 31, ICAM 1, VCAM 1 and P-selectin. Expression of the CD 31 molecule was described as a percentage of the inner surface of the vessel showing positive immunocytochemical reaction. Expression of the remaining molecules (ICAM 1, VCAM 1, P-selectin) was assessed as the percentage of the surface, determined by CD 31 positive reaction. The expression of the adhesion molecules (ICAM 1, VCAM 1, P-selectin) was higher in the fragments of the vein exposed to pressure. In reference to VCAM 1 the difference, as compared with the control group, was: 250% in the fragments infused with blood and 270% in the fragments infused with saline, respectively. The differences for the ICAM 1 were approximately 300% in both experimental groups and 450% for the P-selectin with subtle differences between the two experimental groups. The loss of the endothelial surface (determined by the expression of the CD 31 antigen) was similar in the specimens flushed either with blood or saline, which indicates that the major cause of damage of the endothelium is influence of pressure on the conduit's wall. Mechanical widening of vessels results in the increased expression of the adhesion molecules on the surface of the endothelial cells, and, as a consequence, leads to rise in the leukocyte adhesion and loss of the functional properties of the transplanted veins.


Assuntos
Ponte de Artéria Coronária , Veia Safena/metabolismo , Idoso , Endotélio/metabolismo , Endotélio/cirurgia , Feminino , Humanos , Imuno-Histoquímica , Molécula 1 de Adesão Intercelular/metabolismo , Masculino , Selectina-P/metabolismo , Molécula-1 de Adesão Celular Endotelial a Plaquetas/metabolismo , Pressão , Veia Safena/cirurgia , Molécula 1 de Adesão de Célula Vascular/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA