Phys Med Biol ; 68(2)2023 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-36595327

RESUMO

Objective.Mapping of dose delivery in proton beam therapy can potentially be performed by analyzing thermoacoustic emissions measured by ultrasound arrays. Here, a method is derived and demonstrated for spatial mapping of thermoacoustic sources using numerical time reversal, simulating re-transmission of measured emissions into the medium.Approach.Spatial distributions of thermoacoustic emission sources are shown to be approximated by the analytic-signal form of the time-reversed acoustic field, evaluated at the time of the initial proton pulse. Given calibration of the array sensitivity and knowledge of tissue properties, this approach approximately reconstructs the acoustic source amplitude, equal to the product of the time derivative of the radiation dose rate, mass density, and Grüneisen parameter. This approach was implemented using two models for acoustic fields of the array elements, one modeling elements as line sources and the other as rectangular radiators. Thermoacoustic source reconstructions employed previously reported measurements of emissions from proton energy deposition in tissue-mimicking phantoms. For a phantom incorporating a bone layer, reconstructions accounted for the higher sound speed in bone. Dependence of reconstruction quality on array aperture size and signal-to-noise ratio was consistent with previous acoustic simulation studies.Main results.Thermoacoustic source distributions were successfully reconstructed from acoustic emissions measured by a linear ultrasound array. Spatial resolution of reconstructions was significantly improved in the azimuthal (array) direction by incorporation of array element diffraction. Source localization agreed well with Monte Carlo simulations of energy deposition, and was improved by incorporating effects of inhomogeneous sound speed.Significance.The presented numerical time reversal approach reconstructs thermoacoustic sources from proton beam radiation, based on straightforward processing of acoustic emissions measured by ultrasound arrays. This approach may be useful for ranging and dosimetry of clinical proton beams, if acoustic emissions of sufficient amplitude and bandwidth can be generated by therapeutic proton sources.


Assuntos
Terapia com Prótons , Prótons , Terapia com Prótons/métodos , Acústica , Som , Radiação Ionizante , Imagens de Fantasmas , Método de Monte Carlo
2.
J Neurosci Methods ; 382: 109728, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36244524

RESUMO

BACKGROUND: A device for moving the head during MR imaging, called a Weighted Head Accelerator Mechanism (WHAM), rotates the head of a supine subject within programmable rotation limits and acceleration profiles. The WHAM can be used with custom MRI sequences to visualize the deformation and recoil of in vivo brain parenchyma with high temporal resolution, allowing element-wise calculation of strain and shear forces in the brain. Unlike previous devices, the WHAM can be configured to provide a wide range of motion and acceleration profiles. NEW METHOD: The WHAM was calibrated using a high-speed camera on a laboratory bench and in 1.5 Tesla and 3.0 Tesla MRI scanners using gel phantoms and human subjects. The MR imaging studies employed a spatial spin-saturation tagging sub-sequence, followed by serial image acquisition. In these studies, 256 images were acquired with a temporal resolution of 2.56 ms. Deformation of the brain was quantified by following the spatial tags in the images. RESULTS: MR imaging showed that the WHAM drove quantifiable brain motions using g forces less than those typically observed in day-to-day activities, with peak accelerations of ∼250 rad/sec2. COMPARISON WITH EXISTING METHODS: The peak pre-contact accelerations and velocities achieved by the WHAM device in this study are both higher than devices used in previous studies, while also allowing for modification of these factors. CONCLUSIONS: MR imaging performed with the WHAM provides a direct method to visualize and quantify "brain slosh" in response to rotational acceleration. Consequently, this approach might find utility in evaluating strategies to protect the brain from mild traumatic brain injury (mTBI).


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Cabeça , Aceleração , Reologia
3.
Magn Reson Med ; 87(6): 2885-2900, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35142398

RESUMO

PURPOSE: Develop a deflectable intracardiac MR imaging (ICMRI) guiding-sheath to accelerate imaging during MR-guided electrophysiological (EP) interventions for radiofrequency (500 kHz) ablation (RFA) of arrythmia. Requirements include imaging at three to five times surface-coil SNR in cardiac chambers, vascular insertion, steerable-active-navigation into cardiac chambers, operation with ablation catheters, and safe levels of MR-induced heating. METHODS: ICMRI's 6 mm outer-diameter (OD) metallic-braided shaft had a 2.6 mm OD internal lumen for ablation-catheter insertion. Miniature-Baluns (MBaluns) on ICMRI's 1 m shaft reduced body-coil-induced heating. Distal section was a folded "star"-shaped imaging-coil mounted on an expandable frame, with an integrated miniature low-noise-amplifier overcoming cable losses. A handle-activated movable-shaft expanded imaging-coil to 35 mm OD for imaging within cardiac-chambers. Four MR-tracking micro-coils enabled navigation and motion-compensation, assuming a tetrahedron-shape when expanded. A second handle-lever enabled distal-tip deflection. ICMRI with a protruding deflectable EP catheter were used for MR-tracked navigation and RFA using a dedicated 3D-slicer user-interface. ICMRI was tested at 3T and 1.5T in swine to evaluate (a) heating, (b) cardiac-chamber access, (c) imaging field-of-view and SNR, and (d) intraprocedural RFA lesion monitoring. RESULTS: The 3T and 1.5T imaging SNR demonstrated >400% SNR boost over a 4 × 4 × 4 cm3 FOV in the heart, relative to body and spine arrays. ICMRI with MBaluns met ASTM/IEC heating limits during navigation. Tip-deflection allowed navigating ICMRI and EP catheter into atria and ventricles. Acute-lesion long-inversion-time-T1-weighted 3D-imaging (TWILITE) ablation-monitoring using ICMRI required 5:30 min, half the time needed with surface arrays alone. CONCLUSION: ICMRI assisted EP-catheter navigation to difficult targets and accelerated RFA monitoring.


Assuntos
Ablação por Cateter , Imageamento por Ressonância Magnética , Animais , Arritmias Cardíacas , Ablação por Cateter/métodos , Desenho de Equipamento , Átrios do Coração , Imageamento por Ressonância Magnética/métodos , Suínos
4.
PLoS One ; 16(8): e0256460, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34411195

RESUMO

Computational fluid dynamics (CFD) simulations of respiratory airflow have the potential to change the clinical assessment of regional airway function in health and disease, in pulmonary medicine and otolaryngology. For example, in diseases where multiple sites of airway obstruction occur, such as obstructive sleep apnea (OSA), CFD simulations can identify which sites of obstruction contribute most to airway resistance and may therefore be candidate sites for airway surgery. The main barrier to clinical uptake of respiratory CFD to date has been the difficulty in validating CFD results against a clinical gold standard. Invasive instrumentation of the upper airway to measure respiratory airflow velocity or pressure can disrupt the airflow and alter the subject's natural breathing patterns. Therefore, in this study, we instead propose phase contrast (PC) velocimetry magnetic resonance imaging (MRI) of inhaled hyperpolarized 129Xe gas as a non-invasive reference to which airflow velocities calculated via CFD can be compared. To that end, we performed subject-specific CFD simulations in airway models derived from 1H MRI, and using respiratory flowrate measurements acquired synchronously with MRI. Airflow velocity vectors calculated by CFD simulations were then qualitatively and quantitatively compared to velocity maps derived from PC velocimetry MRI of inhaled hyperpolarized 129Xe gas. The results show both techniques produce similar spatial distributions of high velocity regions in the anterior-posterior and foot-head directions, indicating good qualitative agreement. Statistically significant correlations and low Bland-Altman bias between the local velocity values produced by the two techniques indicates quantitative agreement. This preliminary in vivo comparison of respiratory airway CFD and PC MRI of hyperpolarized 129Xe gas demonstrates the feasibility of PC MRI as a technique to validate respiratory CFD and forms the basis for further comprehensive validation studies. This study is therefore a first step in the pathway towards clinical adoption of respiratory CFD.


Assuntos
Isótopos de Xenônio , Humanos , Hidrodinâmica , Imageamento por Ressonância Magnética , Traqueia
5.
Radiographics ; 41(4): E138-E139, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34197248

RESUMO

The Society for Magnetic Resonance Angiography (SMRA) is a group of researchers and clinicians who are passionate about the benefits of MR angiography (MRA) but understand its challenges. Their mission is to study MRA, continually improve and innovate for the benefit of patients, and most important, educate the medical community so they can take full advantage of the benefits of MRA and overcome its challenges. In support of that mission, the authors have created a series of self-learning modules on behalf of the SMRA to demystify MRA protocols and help the reader perform patient-friendly high-quality MRA on a routine basis in clinical practice. The full digital presentation is available online. ©RSNA, 2021.


Assuntos
Meios de Contraste , Angiografia por Ressonância Magnética , Angiografia Digital , Humanos , Sensibilidade e Especificidade
6.
Magn Reson Med ; 85(3): 1552-1560, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32936497

RESUMO

PURPOSE: To design a new 2D gradient recalled echo MR elastography (MRE) pulse sequence with inflow saturation for measuring liver stiffness in half the breath-hold time compared to standard of care (SC) 2D GRE MRE sequences. METHODS: FASTWALTZ (fusing acceleration and saturation techniques with wave amplitude labeling of time-shifted zeniths) MRE employs an interleaved dual TR strategy with wave amplitude labeling and compressed SENSE undersampling to reduce breath-hold time while incorporating inflow saturation to suppress flow artifacts. The sequence was implemented and compared with SC MRE both in phantoms and in vivo in 5 asymptomatic volunteers. Stiffness values, region of interest size, and breath-hold times were compared between sequences. RESULTS: Stiffness values were comparable between FASTWALTZ and SC MRE for both phantoms and in-vivo data. In volunteers, the group mean stiffness values at 60 Hz and region of interest size were 1.96 ± 0.30 kilopascals and 2279 ± 516 mm2 for SC MRE, and 1.95 ± 0.29 kilopascals and 2061 ± 464 mm2 for FASTWALTZ. Breath-hold duration for FASTWALTZ was 6.3 s compared to 13.3 s for SC MRE. CONCLUSION: FASTWALTZ provides comparable stiffness values in half the breath-hold time compared to SC MRE and may have clinical benefits in patients with limited breath-holding capacity.


Assuntos
Técnicas de Imagem por Elasticidade , Aceleração , Imagem Ecoplanar , Humanos , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes
7.
IEEE Trans Biomed Eng ; 67(6): 1616-1627, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31535979

RESUMO

OBJECTIVE: Cardiovascular interventional devices typically have long metallic braids or backbones to aid in steerability and pushability. However, electromagnetic coupling of metallic-based cardiovascular interventional devices with the radiofrequency (RF) fields present during Magnetic Resonance Imaging (MRI) can make a device unsafe for use in an MRI scanner. We aimed to develop MRI conditional actively-tracked cardiovascular interventional devices by sufficiently attenuating induced currents on the metallic braid/tube and internal-cabling using miniaturized resonant floating RF traps (MBaluns). METHOD: MBaluns were designed for placement at multiple locations along a conducting cardiovascular device to prevent the establishment of standing waves and to dissipate RF-induced energy. The MBaluns were constructed with loosely-wound solenoids to be sensitive to transverse magnetic fields created by both surface currents on the device's metallic backbone and common-mode currents on internal cables. Electromagnetic simulations were used to optimize MBalun parameters. Following optimization, two different MBalun designs were applied to MR-actively-tracked metallic guidewires and metallic-braided electrophysiology ablation catheters. Control-devices were constructed without MBaluns. MBalun performance was validated using network-analyzer quantification of current attenuation, electromagnetic Specific-Absorption-Rate (SAR) analysis, thermal tests during high SAR pulse sequences, and MRI-guided cardiovascular navigation in swine. RESULTS: Electromagnetic SAR simulations resulted in ≈20 dB attenuation at the tip of the wire using six successive MBaluns. Network-analyzer tests confirmed ∼17 dB/MBalun surface-current attenuation. Thermal tests indicated temperature decreases of 5.9 °C in the MBalun-equipped guidewire tip. Both devices allowed rapid vascular navigation resulting from good torquability and MR-Tracking visibility. CONCLUSION: MBaluns increased device diameter by 20%, relative to conventional devices, providing a spatially-efficient means to prevent heating during MRI. SIGNIFICANCE: MBaluns allow use of long metallic components, which improves mechanical performance in active MR-guided interventional devices.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Animais , Catéteres , Eletrofisiologia , Desenho de Equipamento , Imagens de Fantasmas , Suínos
8.
Magn Reson Med ; 82(1): 367-376, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30847967

RESUMO

PURPOSE: Hyperpolarized (HP) media enable biomedical imaging applications that cannot be achieved with conventional MRI contrast agents. Unfortunately, quantifying HP images is challenging, because relaxation and radio-frequency pulsing generate spatially varying signal decay during acquisition. We demonstrate that, by combining center-out k-space sampling with postacquisition keyhole reconstruction, voxel-by-voxel maps of regional HP magnetization decay can be generated with no additional data collection. THEORY AND METHODS: Digital phantom, HP 129 Xe phantom, and in vivo 129 Xe human (N = 4 healthy; N = 2 with cystic fibrosis) imaging was performed using radial sampling. Datasets were reconstructed using a postacquisition keyhole approach in which 2 temporally resolved images were created and used to generate maps of regional magnetization decay following a simple analytical model. RESULTS: Mean, keyhole-derived decay terms showed excellent agreement with the decay used in simulations (R2 = 0.996) and with global attenuation terms in HP 129 Xe phantom imaging (R2 > 0.97). Mean regional decay from in vivo imaging agreed well with global decay values and displayed spatial heterogeneity that matched expected variations in flip angle and oxygen partial pressure. Moreover, these maps could be used to correct variable signal decay across the image volume. CONCLUSIONS: We have demonstrated that center-out trajectories combined with keyhole reconstruction can be used to map regional HP signal decay and to quantitatively correct images. This approach may be used to improve the accuracy of quantitative measures obtained from hyperpolarized media. Although validated with gaseous HP 129 Xe in this work, this technique can be generalized to any hyperpolarized agent.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Adolescente , Adulto , Criança , Pré-Escolar , Meios de Contraste , Fibrose Cística/diagnóstico por imagem , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Imagens de Fantasmas , Isótopos de Xenônio
9.
Magn Reson Imaging Clin N Am ; 27(2): 341-371, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30910102

RESUMO

Pediatric musculoskeletal tumors comprise approximately 10% of childhood neoplasms, and MR imaging has been used as the imaging evaluation standard for these tumors. The role of MR imaging in these cases includes identification of tumor origin, tissue characterization, and definition of tumor extent and relationship to adjacent structures as well as therapeutic response in posttreatment surveillance. Technical advances have enabled quantitative evaluation of biochemical changes in tumors. This article reviews recent updates to MR imaging of pediatric musculoskeletal tumors, focusing on advanced MR imaging techniques and providing information on the relevant physics of these techniques, clinical applications, and pitfalls.


Assuntos
Imageamento por Ressonância Magnética/métodos , Doenças Musculoesqueléticas/diagnóstico por imagem , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Sistema Musculoesquelético/diagnóstico por imagem
10.
Clin Biomech (Bristol, Avon) ; 66: 88-96, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-29079097

RESUMO

BACKGROUND: Computational fluid dynamics simulations of respiratory airflow in the upper airway reveal clinically relevant information, including sites of local resistance, inhaled particle deposition, and the effect of pathological constrictions. Unlike previous simulations, which have been performed on rigid anatomical models from static medical imaging, this work utilises ciné imaging during respiration to create dynamic models and more closely represent airway physiology. METHODS: Airway movement maps were obtained from non-rigid image registration of fast-cine MRI and applied to high-spatial-resolution airway surface models. Breathing flowrates were recorded simultaneously with imaging. These data formed the boundary conditions for large eddy simulation computations of the airflow from exterior mask to bronchi. Simulations with rigid geometries were performed to demonstrate the resulting airflow differences between airflow simulations in rigid and dynamic airways. FINDINGS: In the analysed rapid breathing manoeuvre, incorporating airway movement significantly changed the findings of the CFD simulations. Peak resistance increased by 19.8% and occurred earlier in the breath. Overall pressure loss decreased by 19.2%, and the proportion of flow in the mouth increased by 13.0%. Airway wall motion was out-of-phase with the air pressure force, demonstrating the presence of neuromuscular motion. In total, the anatomy did 25.2% more work on the air than vice versa. INTERPRETATIONS: Realistic movement of the airway is incorporated into CFD simulations of airflow in the upper airway for the first time. This motion is vital to producing clinically relevant computational models of respiratory airflow and will allow novel analysis of dynamic conditions, such as sleep apnoea.


Assuntos
Hidrodinâmica , Pulmão/fisiopatologia , Movimento , Respiração , Traqueia/fisiopatologia , Adulto , Simulação por Computador , Humanos , Imageamento por Ressonância Magnética , Masculino , Modelos Anatômicos , Modelos Biológicos , Movimento (Física)
11.
J Magn Reson Imaging ; 50(2): 391-396, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30584687

RESUMO

BACKGROUND: Magnetic resonance elastography (MRE) has proven to be useful for assessing chronic liver disease. However, MRE images are acquired with breath-holding (BH) to limit respiratory motion artifacts, which may be difficult in some patients. PURPOSE: To implement a respiratory-triggered (RT) spin-echo echo-planar imaging (SE-EPI) MRE technique and to validate its performance through comparison to a BH SE-EPI MRE technique. STUDY TYPE: Prospective feasibility study. SUBJECTS: Twenty-three adult volunteers (18 without and 5 with liver disease). FIELD STRENGTH/SEQUENCES: 1.5 T Philips Ingenia MR scanner; RT and BH SE-EPI MRE sequences. ASSESSMENT: Four axial images were obtained through the middle of the liver with each technique. Liver stiffness measurements (in kPa) were made from elastograms, with 95% confidence maps overlaid, for both MRE sequences. STATISTICAL TESTS: Liver stiffness measurements were compared using the paired t-test (two-sided). Absolute agreement between the two techniques was evaluated using Lin's concordance coefficient (rc ). Bland-Altman analysis was used to assess the mean bias between the techniques and 95% limits of agreement, using BH MRE as the reference standard. RESULTS: There was excellent agreement (rc = 0.98; 95% confidence interval: 0.96-0.99) between RT and BH SE-EPI MRE. Mean (±SD) stiffness values from BH and RT SE-EPI MRE techniques were 2.40 ± 1.15 kPa and 2.37 ± 1.06 kPa, respectively, with no significant difference (P = 0.54) and no significant bias (mean bias of +0.03 kPa; 95% limits of agreement: -0.39 to 0.45 kPa). Measurable regions of interest in the liver were slightly smaller with the RT technique (mean difference of 1.91 cm2 ; P = 0.04). DATA CONCLUSION: RT SE-EPI MRE is feasible and yields comparable results to BH SE-EPI MRE. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:391-396.


Assuntos
Imagem Ecoplanar/métodos , Técnicas de Imagem por Elasticidade/métodos , Hepatopatias/diagnóstico por imagem , Fígado/diagnóstico por imagem , Adulto , Artefatos , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Estudos Prospectivos , Reprodutibilidade dos Testes , Respiração , Adulto Jovem
12.
Int J Numer Method Biomed Eng ; 34(12): e3144, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30133165

RESUMO

Computational fluid dynamics (CFD) simulations of airflow in the human airways have the potential to provide a great deal of information that can aid clinicians in case management and surgical decision making, such as airway resistance, energy expenditure, airflow distribution, heat and moisture transfer, and particle deposition, as well as the change in each of these due to surgical interventions. However, the clinical relevance of CFD simulations has been limited to date, as previous models either did not incorporate neuromuscular motion or any motion at all. Many common airway pathologies, such as obstructive sleep apnea (OSA) and tracheomalacia, involve large movements of the structures surrounding the airway, such as the tongue and soft palate. Airway wall motion may be due to many factors including neuromuscular motion, internal aerodynamic forces, and external forces such as gravity. Therefore, to realistically model these airway diseases, a method is required to derive the airway wall motion, whatever the cause, and apply it as a boundary condition to CFD simulations. This paper presents and validates a novel method of capturing in vivo motion of airway walls from magnetic resonance images with high spatiotemporal resolution, through a novel combination of non-rigid image, surface, and surface-normal-vector registration. Coupled with image-synchronous pneumotachography, this technique provides the necessary boundary conditions for dynamic CFD simulations of breathing, allowing the effect of the airway's complex motion to be calculated for the first time, in both normal subjects and those with conditions such as OSA.


Assuntos
Simulação por Computador , Imageamento por Ressonância Magnética , Modelos Biológicos , Movimento , Sistema Respiratório , Apneia Obstrutiva do Sono , Adulto , Criança , Humanos , Masculino , Mecânica Respiratória , Sistema Respiratório/diagnóstico por imagem , Sistema Respiratório/fisiopatologia , Apneia Obstrutiva do Sono/diagnóstico por imagem , Apneia Obstrutiva do Sono/fisiopatologia
13.
Int J Radiat Oncol Biol Phys ; 99(3): 618-626, 2017 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-28843373

RESUMO

PURPOSE: We designed and built dedicated active magnetic resonance (MR)-tracked (MRTR) stylets. We explored the role of MRTR in a prospective clinical trial. METHODS AND MATERIALS: Eleven gynecologic cancer patients underwent MRTR to rapidly optimize interstitial catheter placement. MRTR catheter tip location and orientation were computed and overlaid on images displayed on in-room monitors at rates of 6 to 16 frames per second. Three modes of actively tracked navigation were analyzed: coarse navigation to the approximate region around the tumor; fine-tuning, bringing the stylets to the desired location; and pullback, with MRTR stylets rapidly withdrawn from within the catheters, providing catheter trajectories for radiation treatment planning (RTP). Catheters with conventional stylets were inserted, forming baseline locations. MRTR stylets were substituted, and catheter navigation was performed by a clinician working inside the MRI bore, using monitor feedback. RESULTS: Coarse navigation allowed repositioning of the MRTR catheters tips by 16 mm (mean), relative to baseline, in 14 ± 5 s/catheter (mean ± standard deviation [SD]). The fine-tuning mode repositioned the catheter tips by a further 12 mm, in 24 ± 17 s/catheter. Pullback mode provided catheter trajectories with RTP point resolution of ∼1.5 mm, in 1 to 9 s/catheter. CONCLUSIONS: MRTR-based navigation resulted in rapid and optimal placement of interstitial brachytherapy catheters. Catheters were repositioned compared with the initial insertion without tracking. In pullback mode, catheter trajectories matched computed tomographic precision, enabling their use for RTP.


Assuntos
Braquiterapia/instrumentação , Neoplasias dos Genitais Femininos/radioterapia , Imagem por Ressonância Magnética Intervencionista/instrumentação , Radioterapia Guiada por Imagem/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Braquiterapia/métodos , Catéteres , Feminino , Neoplasias dos Genitais Femininos/diagnóstico por imagem , Neoplasias dos Genitais Femininos/patologia , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Radioterapia Guiada por Imagem/instrumentação
14.
Pediatr Radiol ; 47(8): 1001-1011, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28470389

RESUMO

With its soft-tissue definition, multiplanar capabilities and advanced imaging techniques, magnetic resonance imaging (MRI) for neonatal care can provide better understanding of pathology, allowing for improved care and counseling to families. However, MR imaging in neonates is often difficult due to patient instability and the complex support necessary for survival. In our institution, we have installed a small footprint magnet in the neonatal intensive care unit (NICU) to minimize patient risks and provide the ability to perform MR imaging safely in this population. With this system, we have been able to provide more information with regard to central nervous system disorders, abdominal pathology, and pulmonary and airway abnormalities, and have performed postmortem imaging as an alternative or supplement to pathological autopsy. In our experience, an MR scanner situated within the NICU has allowed for safer and more expedited imaging of this vulnerable population.


Assuntos
Doenças do Recém-Nascido/diagnóstico por imagem , Imageamento por Ressonância Magnética/instrumentação , Desenho de Equipamento , Feminino , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Masculino
15.
Magn Reson Med ; 75(5): 2204-16, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26101951

RESUMO

PURPOSE: To restore 12-lead electrocardiographic (ECG) signal fidelity inside MRI by removing magnetic field gradient-induced voltages during high gradient duty cycle sequences. THEORY AND METHODS: A theoretical equation was derived to provide first- and second-order electrical fields induced at individual ECG electrodes as a function of gradient fields. Experiments were performed at 3T on healthy volunteers using a customized acquisition system that captured the full amplitude and frequency response of ECGs, or a commercial recording system. The 19 equation coefficients were derived via linear regression of data from accelerated sequences and were used to compute induced voltages in real-time during full resolution sequences to remove ECG artifacts. Restored traces were evaluated relative to ones acquired without imaging. RESULTS: Measured induced voltages were 0.7 V peak-to-peak during balanced steady state free precession (bSSFP) with the heart at the isocenter. Applying the equation during gradient echo sequencing, three-dimensional fast spin echo, and multislice bSSFP imaging restored nonsaturated traces and second-order concomitant terms showed larger contributions in electrodes further from the magnet isocenter. Equation coefficients are evaluated with high repeatability (ρ = 0.996) and are dependent on subject, sequence, and slice orientation. CONCLUSION: Close agreement between theoretical and measured gradient-induced voltages allowed for real-time removal. Prospective estimation of sequence periods in which large induced voltages occur may allow hardware removal of these signals.


Assuntos
Eletrocardiografia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Adulto , Algoritmos , Artefatos , Técnicas de Imagem de Sincronização Cardíaca , Eletrodos , Voluntários Saudáveis , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Reprodutibilidade dos Testes
16.
Med Phys ; 42(12): 7114-21, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26632065

RESUMO

PURPOSE: In gynecologic cancers, magnetic resonance (MR) imaging is the modality of choice for visualizing tumors and their surroundings because of superior soft-tissue contrast. Real-time MR guidance of catheter placement in interstitial brachytherapy facilitates target coverage, and would be further improved by providing intraprocedural estimates of dosimetric coverage. A major obstacle to intraprocedural dosimetry is the time needed for catheter trajectory reconstruction. Herein the authors evaluate an active MR tracking (MRTR) system which provides rapid catheter tip localization and trajectory reconstruction. The authors assess the reliability and spatial accuracy of the MRTR system in comparison to standard catheter digitization using magnetic resonance imaging (MRI) and CT. METHODS: The MRTR system includes a stylet with microcoils mounted on its shaft, which can be inserted into brachytherapy catheters and tracked by a dedicated MRTR sequence. Catheter tip localization errors of the MRTR system and their dependence on catheter locations and orientation inside the MR scanner were quantified with a water phantom. The distances between the tracked tip positions of the MRTR stylet and the predefined ground-truth tip positions were calculated for measurements performed at seven locations and with nine orientations. To evaluate catheter trajectory reconstruction, fifteen brachytherapy catheters were placed into a gel phantom with an embedded catheter fixation framework, with parallel or crossed paths. The MRTR stylet was then inserted sequentially into each catheter. During the removal of the MRTR stylet from within each catheter, a MRTR measurement was performed at 40 Hz to acquire the instantaneous stylet tip position, resulting in a series of three-dimensional (3D) positions along the catheter's trajectory. A 3D polynomial curve was fit to the tracked positions for each catheter, and equally spaced dwell points were then generated along the curve. High-resolution 3D MRI of the phantom was performed followed by catheter digitization based on the catheter's imaging artifacts. The catheter trajectory error was characterized in terms of the mean distance between corresponding dwell points in MRTR-generated catheter trajectory and MRI-based catheter digitization. The MRTR-based catheter trajectory reconstruction process was also performed on three gynecologic cancer patients, and then compared with catheter digitization based on MRI and CT. RESULTS: The catheter tip localization error increased as the MRTR stylet moved further off-center and as the stylet's orientation deviated from the main magnetic field direction. Fifteen catheters' trajectories were reconstructed by MRTR. Compared with MRI-based digitization, the mean 3D error of MRTR-generated trajectories was 1.5 ± 0.5 mm with an in-plane error of 0.7 ± 0.2 mm and a tip error of 1.7 ± 0.5 mm. MRTR resolved ambiguity in catheter assignment due to crossed catheter paths, which is a common problem in image-based catheter digitization. In the patient studies, the MRTR-generated catheter trajectory was consistent with digitization based on both MRI and CT. CONCLUSIONS: The MRTR system provides accurate catheter tip localization and trajectory reconstruction in the MR environment. Relative to the image-based methods, it improves the speed, safety, and reliability of the catheter trajectory reconstruction in interstitial brachytherapy. MRTR may enable in-procedural dosimetric evaluation of implant target coverage.


Assuntos
Braquiterapia/instrumentação , Braquiterapia/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Radioterapia Guiada por Imagem/instrumentação , Radioterapia Guiada por Imagem/métodos , Adenocarcinoma/patologia , Adenocarcinoma/radioterapia , Algoritmos , Artefatos , Catéteres , Feminino , Humanos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Imagens de Fantasmas , Estudos Prospectivos , Radiometria/instrumentação , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Neoplasias Uterinas/patologia , Neoplasias Uterinas/radioterapia , Água
17.
Artigo em Inglês | MEDLINE | ID: mdl-26457072

RESUMO

MRI acoustic exposure has the potential to elicit physiological distress and impact development in preterm and term infants. To mitigate this risk, a novel acoustically quiet coil was developed to reduce the sound pressure level experienced by neonates during MR procedures. The new coil has a conventional high-pass birdcage RF design, but is built on a framework of sound abating material. We evaluated the acoustic and MR imaging performance of the quiet coil and a conventional body coil on two small footprint NICU MRI systems. Sound pressure level and frequency response measurements were made for six standard clinical MR imaging protocols. The average sound pressure level, reported for all six imaging pulse sequences, was 82.2 dBA for the acoustically quiet coil, and 91.1 dBA for the conventional body coil. The sound pressure level values measured for the acoustically quiet coil were consistently lower, 9 dBA (range 6-10 dBA) quieter on average. The acoustic frequency response of the two coils showed a similar harmonic profile for all imaging sequences. However, the amplitude was lower for the quiet coil, by as much as 20 dBA.

18.
Magn Reson Med ; 73(5): 1803-11, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-24903165

RESUMO

PURPOSE: To develop an active MR-tracking system to guide placement of metallic devices for radiation therapy. METHODS: An actively tracked metallic stylet for brachytherapy was constructed by adding printed-circuit micro-coils to a commercial stylet. The coil design was optimized by electromagnetic simulation, and has a radio-frequency lobe pattern extending ∼5 mm beyond the strong B0 inhomogeneity region near the metal surface. An MR-tracking sequence with phase-field dithering was used to overcome residual effects of B0 and B1 inhomogeneities caused by the metal, as well as from inductive coupling to surrounding metallic stylets. The tracking system was integrated with a graphical workstation for real-time visualization. The 3 Tesla MRI catheter-insertion procedures were tested in phantoms and ex vivo animal tissue, and then performed in three patients during interstitial brachytherapy. RESULTS: The tracking system provided high-resolution (0.6 × 0.6 × 0.6 mm(3) ) and rapid (16 to 40 frames per second, with three to one phase-field dithering directions) catheter localization in phantoms, animals, and three gynecologic cancer patients. CONCLUSION: This is the first demonstration of active tracking of the shaft of metallic stylet in MR-guided brachytherapy. It holds the promise of assisting physicians to achieve better targeting and improving outcomes in interstitial brachytherapy.


Assuntos
Artefatos , Braquiterapia/instrumentação , Braquiterapia/métodos , Marcadores Fiduciais , Neoplasias dos Genitais Femininos/radioterapia , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Metais , Radioterapia Assistida por Computador/instrumentação , Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/instrumentação , Radioterapia Guiada por Imagem/métodos , Animais , Galinhas , Gráficos por Computador , Simulação por Computador , Campos Eletromagnéticos , Desenho de Equipamento , Feminino , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Imagens de Fantasmas , Software
19.
Pediatr Radiol ; 44(8): 1011-9, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24595878

RESUMO

BACKGROUND: To eliminate the medical risks and logistical challenges of transporting infants from the neonatal intensive care unit (NICU) to the radiology department for magnetic resonance imaging, a small-footprint 1.5-T MRI scanner has been developed for neonatal imaging within the NICU. MRI is known to be noisy, and exposure to excessive acoustic noise has the potential to elicit physiological distress and impact development in the term and preterm infant. OBJECTIVE: To measure and compare the acoustic noise properties of the NICU MRI system against those of a conventional 1.5-T MRI system. MATERIALS AND METHODS: We performed sound pressure level measurements in the NICU MRI scanner and in a conventional adult-size whole-body 1.5-T MRI system. Sound pressure level measurements were made for six standard clinical MR imaging protocols. RESULTS: The average sound pressure level value, reported in unweighted (dB) and A-weighted (dBA) decibels for all six imaging pulse sequences, was 73.8 dB and 88 dBA for the NICU scanner, and 87 dB and 98.4 dBA for the conventional MRI scanner. The sound pressure level values measured on the NICU scanner for each of the six MR imaging pulse sequences were consistently and significantly (P = 0.03) lower, with an average difference of 14.2 dB (range 10-21 dB) and 11 dBA (range 5-18 dBA). The sound pressure level frequency response of the two MR systems showed a similar harmonic structure above 200 Hz for all imaging sequences. The amplitude, however, was appreciably lower for the NICU scanner, by as much as 30 dB, for frequencies below 200 Hz. CONCLUSION: The NICU MRI system is quieter than conventional MRI scanners, improving safety for the neonate and facilitating siting of the unit within the NICU.


Assuntos
Unidades de Terapia Intensiva Neonatal , Imageamento por Ressonância Magnética/instrumentação , Ruído , Acústica , Desenho de Equipamento
20.
Magn Reson Med ; 71(3): 1336-47, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23580148

RESUMO

PURPOSE: High-fidelity 12-lead electrocardiogram (ECG) is important for physiological monitoring of patients during MR-guided intervention and cardiac MRI. Issues in obtaining noncorrupted ECGs inside MRI include a superimposed magneto-hydro-dynamic voltage, gradient switching-induced voltages, and radiofrequency heating. These problems increase with magnetic field. The aim of this study is to develop and clinically validate a 1.5T MRI-conditional 12-lead ECG system. METHODS: The system was constructed with transmission lines to reduce radiofrequency induction and switching circuits to remove induced voltages. Adaptive filters, trained by 12-lead measurements outside MRI and in two orientations inside MRI, were used to remove the magneto-hydro-dynamic voltage. The system was tested on 10 (one exercising) volunteers and four arrhythmia patients. RESULTS: Switching circuits removed most imaging-induced voltages (residual noise <3% of the R-wave). Magneto-hydro-dynamic voltage removal provided intra-MRI ECGs that varied by <3.8% from those outside the MRI, preserving the true S-wave to T-wave segment. In premature ventricular contraction (PVC) patients, clean ECGs separated premature ventricular contraction and sinus rhythm beats. Measured heating was <1.5°C. The system reliably acquired multiphase (steady-state free precession) wall-motion-cine and phase-contrast-cine scans, including subjects in whom 4-lead gating failed. The system required a minimum repetition time of 4 ms to allow robust ECG processing. CONCLUSION: High-fidelity intra-MRI 12-lead ECG is possible.


Assuntos
Fibrilação Atrial/cirurgia , Técnicas de Imagem de Sincronização Cardíaca/instrumentação , Eletrocardiografia/instrumentação , Imagem por Ressonância Magnética Intervencionista/instrumentação , Cirurgia Assistida por Computador/instrumentação , Idoso , Animais , Fibrilação Atrial/diagnóstico , Procedimentos Cirúrgicos Cardiovasculares/instrumentação , Eletrodos , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos , Resultado do Tratamento