1.
Biomedicines ; 9(6)2021 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-34205548

RESUMO

Heparins, unfractionated or low molecular weight, are permanently in the spotlight of both clinical indications and laboratory monitoring. An accurate drug dosage is necessary for an efficient and safe therapy. The one-stage kinetic anti-FXa assays are the most widely and universally used with full automation for large series, without needing exogenous antithrombin. The WHO International Standards are available for UFH and LMWH, but external quality assessment surveys still report a high inter-assay variability. This heterogeneity results from the following: assay formulation, designed without or with dextran sulfate to measure all heparin in blood circulation; calibrators for testing UFH or LMWH with the same curve; and automation parameters. In this study, various factors which impact heparin measurements are reviewed, and we share our experience to optimize assays for testing all heparin anticoagulant activities in plasma. Evidence is provided on the usefulness of low molecular weight dextran sulfate to completely mobilize all of the drug present in blood circulation. Other key factors concern the adjustment of assay conditions to obtain fully superimposable calibration curves for UFH and LMWH, calibrators' formulations, and automation parameters. In this study, we illustrate the performances of different anti-FXa assays used for testing heparin on UFH or LMWH treated patients' plasmas and obtained using citrate or CTAD anticoagulants. Comparable results are obtained only when the CTAD anticoagulant is used. Using citrate as an anticoagulant, UFH is underestimated in the absence of dextran sulfate. Heparin calibrators, adjustment of automation parameters, and data treatment contribute to other smaller differences.

2.
Int J Lab Hematol ; 43(4): 771-778, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33974363

RESUMO

BACKGROUND: Lupus anticoagulants (LA) are detected by prolongation of clotting times for dilute Russell's viper venom time (dRVVT) and activated partial thromboplastin time (APTT) screening tests. Direct oral anticoagulants (DOACs) can interfere with both screening and confirmatory tests. The present study aimed to investigate the influence of direct factor Xa inhibitors (DiXaIs) on screen, confirm and mixing tests and establish a method for differentiation from other sample types. MATERIALS AND METHODS: A total of 257 samples including nonanticoagulated LA positive, LA positive with DiXaIs, factor deficiency, FVIII inhibitors, warfarin and non-APS DiXaIs were tested. APTT reagents Cephen LS/Cephen and dRVVT reagents LA1/LA2 were used, respectively, to screen/confirm the study group. Index of circulating anticoagulant (ICA) was calculated from clotting times based on the following formula as ICA screening and ICA confirmation. ICA= (1:1 Mix sample - Normal pooled plasma) / Screen patient x 100. An ICA matrix was established which suggested the presence of a DiXaI when both ICA screening and confirmation were above the cut-off. When only ICA screening is elevated, LA is suspected. RESULTS: Sensitivity and specificity of the ICA matrix were 52.2% and 92.8% for DiXaIs and 38.1% and 96.7% for LA in APTT, and 61.2% and 92.9% for DiXaIs and 22.2% and 88.4% for LA in dRVVT, respectively. CONCLUSION: The ICA matrix achieved high specificity with a lower apparent sensitivity for DiXaI samples comparatively to other devices but due only to less interferences: the matrix could contribute to differentiating DiXaIs from LA in samples where anticoagulation status is unknown.


Assuntos
Inibidores do Fator Xa/sangue , Inibidor de Coagulação do Lúpus/sangue , Coagulação Sanguínea/efeitos dos fármacos , Testes de Coagulação Sanguínea/métodos , Inibidores do Fator Xa/farmacologia , Humanos , Inibidor de Coagulação do Lúpus/farmacologia , Tempo de Tromboplastina Parcial/métodos , Tempo de Protrombina/métodos
3.
Biomedicines ; 9(5)2021 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-33919121

RESUMO

The introduction of direct oral anticoagulants (DOACs), such as dabigatran, rivaroxaban, apixaban, edoxaban, and betrixaban, provides safe and effective alternative to previous anticoagulant therapies. DOACs directly, selectively, and reversibly inhibit factors IIa or Xa. The coagulation effect follows the plasma concentration-time profile of the respective anticoagulant. The short half-life of a DOAC constrains the daily oral intake. Because DOACs have predictable pharmacokinetic and pharmacodynamic responses at a fixed dose, they do not require monitoring. However in specific clinical situations and for particular patient populations, testing may be helpful for patient management. The effect of DOACs on the screening coagulation assays such as prothrombin time (PT), activated partial thromboplastin time (APTT), and thrombin time (TT) is directly linked to reagent composition, and clotting time can be different from reagent to reagent, depending on the DOAC's reagent sensitivity. Liquid chromatography-mass spectrometry (LC-MS/MS) is considered the gold standard method for DOAC measurement, but it is time consuming and requires expensive equipment. The general consensus for the assessment of a DOAC is clotting or chromogenic assays using specific standard calibrators and controls. This review provides a short summary of DOAC properties and an update on laboratory methods for measuring DOACs.

4.
Int J Lab Hematol ; 41(1): 60-68, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30248243

RESUMO

INTRODUCTION: A prolonged activated partial thromboplastin time (APTT) may be indicative of a specific or multiple factor deficiency, therapeutic anticoagulation, presence of a nonspecific factor inhibitor, or lupus anticoagulant (LA). Recently, pairing of the LA-sensitive APTT and standard APTT reagents, Cephen LS and Cephen, respectively, has been shown to be effective in LA detection. The present study aimed to evaluate the usefulness of this reagent pair for discriminating between causes of APTT elevation and the detection of LA in conjunction with dilute Russell's viper venom time (dRVVT). METHODS: Plasma samples from 50 normal and 105 non-anticoagulated LA-positive patients in routine dRVVT and/or dilute APTT (dAPTT) via the percent correction formula were employed. Cephen LS/Cephen and dRVVT reagents LA1/LA2 were used to screen/confirm, respectively. Thirty-four symptomatic LA-negative, 25 warfarinised non-antiphospholipid syndrome, 6 coagulation inhibitors, 17 samples with hereditary elevated APTT, and 24 FVIII/IX/XI/XII and 17 FII/V/X artificial single deficiency plasmas were used. RESULTS: Thirty-three samples out of 105 (31%) were LA-positive in Cephen LS/Cephen. The total percent positivity in Cephen LS/Cephen and LA1/LA2 pairs was 89.1% against samples with the routine dRVVT/dAPTT double positive. The percent corrections of Cephen LS/Cephen in the routine dAPTT/dRVVT positive group were significantly higher than those in all other groups. CONCLUSIONS: The percent correction of the APTT reagent pair showed higher values in LA-positive samples. The combination will be useful with respect to differentiating LA from other abnormal samples and is effective in LA detection when paired with dRVVT.


Assuntos
Inibidor de Coagulação do Lúpus/sangue , Tempo de Tromboplastina Parcial/métodos , Tempo de Protrombina , Anticorpos Antifosfolipídeos , Síndrome Antifosfolipídica , Estudos de Casos e Controles , Diagnóstico Diferencial , Humanos
5.
Platelets ; 29(1): 95-97, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28960123

RESUMO

BACKGROUND: Light transmission aggregometry (LTA) is considered as the gold standard for testing platelet function in the setting of both platelet disorders suspicion and response to antiplatelet therapy evaluation. LTA requires however specialized equipment, substantial blood sample volumes, is technically challenging and time-consuming. AIM: To evaluate an automated platelet aggregation method performed on a routine coagulation analyzer Sysmex CS-2000i. METHODS: 46 patients presenting a bleeding syndrome and 62 patients with acute coronary syndrome receiving dual antiplatelet therapy were studied in total. Platelet aggregations were performed on CS-2000i equipped with a dedicated software and on APACT-4004 (Elitech, France) as the reference instrument. Aggregation was measured by monitoring the changes in light absorbance occurring in response to ADP 2.5, 5 and 10µM, collagen 3.3 µg/mL, epinephrin 10µM, ristocetin 1.25 mg/mL and arachidonic acid 0.5 mg/mL in platelet rich plasma (PRP). PRP were tested simultaneously on both CS-2000i and APACT-4004 devices. Platelet stirred speed were 800 rpm for both instruments. RESULTS: Significant correlations were observed between CS-2000i and LTA after all stimulations (p< 0.001). Patients presenting a bleeding syndrome had similar aggregation profiles with both methods. A single patient presented a severe platelet disorder (Glanzmann Thrombasthenia) and its PRP showed defective aggregation in response to all agonists except ristocetin with both instruments. Finally, the inter-agreement rates for CS-2000i and APACT-4004 to detect low responders to thienopyridines or aspirine were strong (weighted kappa> 0.70). CONCLUSION: Platelet aggregation on the routine coagulation analyzer CS-2000i is an easily accessible, handy, reliable, standardized, and rapid tool to assess platelet function which allows to skirt most of the LTA limitations.


Assuntos
Testes de Coagulação Sanguínea/métodos , Testes de Função Plaquetária/métodos , Biomarcadores/sangue , Testes de Coagulação Sanguínea/instrumentação , Transtornos Plaquetários/sangue , Transtornos Plaquetários/diagnóstico , Transtornos Plaquetários/tratamento farmacológico , Plaquetas/efeitos dos fármacos , Plaquetas/metabolismo , Humanos , Agregação Plaquetária/efeitos dos fármacos , Inibidores da Agregação Plaquetária/farmacologia , Inibidores da Agregação Plaquetária/uso terapêutico , Testes de Função Plaquetária/instrumentação , Reprodutibilidade dos Testes
6.
Transfus Apher Sci ; 56(4): 612-625, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28803708

RESUMO

Anti-phospholipid syndrome is a complex and severe clinical situation, associated with symptoms such as recurrent thrombosis, arterial or venous, at any site, pregnancy loss, and other related syndromes. These clinical burdens, are highly variable from patient to patient, and are associated with biological abnormalities, such as the presence of the Lupus Anticoagulant or phospholipid dependent antibodies, confirmed on two occasions at least 12 weeks apart. From the diagnosis standpoint, both, functional (clotting) or immunological assays, are difficult to standardize and to optimize, due to the absence of reference material, or a characteristic clinical group, and international reference preparations. Large cohort studies are necessary for defining the usefulness of each assay, in terms of specificity, sensitivity, accuracy and for following-up the disease evolution. Clotting assays are based on Activated Partial Thromboplastin Time (APTT) and diluted Russell Viper Venom Time (dRVVT), performed at low and high phospholipid concentration, or on 1:1 mixtures of tested sample and a normal plasma pool. They allow evaluation of the paradoxal effects of LAs, which are pro-thrombotic in vivo, and anticoagulant in vivo. Use of synthetic phospholipids improves assay specificities and sensitivities, especially in patients treated with anticoagulants. Immunoassays can also be used for testing phospholipid dependent antibodies, first identified and measured as anti-cardiolipin antibodies, but now characterized as targeted to phospholipid cofactor proteins: mainly ß2GP1 (which exposes cryptic epitopes upon binding to phospholipids), and in some cases prothrombin, and more rarely Protein S, Factor XIII, Protein Z or Annexin V. Use of optimized assays designed with well-characterized anionic phospholipids, then complexed with highly purified phospholipid cofactor protein (mainly ß2GP1), offers a better link between reactivity and clinical associations, than the former assays which were empirically designed with cardiolipin. Standardization also remains complicated due to the absence of international standards and harmonized quantitation units. Validation on large cohorts of negative and positive patients remains the key approach for defining assay performance and clinical usefulness. Laboratory practice for all these methods is now greatly facilitated thanks to the use of automated instruments and dedicated software. Along with clinical criteria, laboratory assays are of great usefulness for identification and confirmation of the anti-phospholipid syndrome and they allow disease follow-up when appropriate patient management is in place.


Assuntos
Síndrome Antifosfolipídica/sangue , Síndrome Antifosfolipídica/diagnóstico , Anexina A5/metabolismo , Anticorpos Anticardiolipina/sangue , Síndrome Antifosfolipídica/terapia , Proteínas Sanguíneas/metabolismo , Fator XIII/metabolismo , Humanos , Inibidor de Coagulação do Lúpus/sangue , Tempo de Tromboplastina Parcial/métodos , Proteína S/metabolismo , Protrombina/metabolismo , Tempo de Protrombina/métodos
7.
Platelets ; 28(3): 235-241, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28102740

RESUMO

Functional and genetic assays for measuring platelet microvesicles (PMVs) are presented and discussed. Functional assays concern two groups of methods: a) homogeneous assays using the cofactor activity of phospholipids (PPLs) contained in PMVs and present in assayed plasmas, and a coagulation or a thrombin generation assay (TGA) as "end points"; b) capture-based assays, in which PMVs bind to an immobilized ligand, such as Annexin V in the presence of calcium, or monoclonal antibodies (MoAbs) specific for membrane proteins. Genetic assays aim to detect micro-RNA (miRNA) present in PMVs: miRNA must be extracted from plasma, and the expression pattern can be determined by various methods such as quantitative real-time PCR, microarray or sequencing. All these technical approaches introduce new exploration tools for measuring or quantitating PMVs or their associated activities, as biomarkers for disease evolution, their diagnosis or prognosis, and for monitoring of some antithrombotic or anti-inflammatory therapies. They offer invaluable analytical tools for research, drug discovery and epidemiological studies and have a strong potential as diagnostic tests.


Assuntos
Bioensaio/normas , Testes de Coagulação Sanguínea/normas , Plaquetas/metabolismo , Vesículas Extracelulares/metabolismo , Trombina/metabolismo , Anexina A5/química , Biomarcadores/metabolismo , Coagulação Sanguínea/fisiologia , Plaquetas/citologia , Comunicação Celular , Endocitose , Células Endoteliais/citologia , Células Endoteliais/metabolismo , Ensaio de Imunoadsorção Enzimática , Vesículas Extracelulares/química , Humanos , MicroRNAs/genética , MicroRNAs/metabolismo , Ativação Plaquetária , Reação em Cadeia da Polimerase em Tempo Real
8.
Transfus Apher Sci ; 56(1): 91-97, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28089408

RESUMO

The key coagulation factor FVII, and its activated form FVIIa, present a major interest for their role at the initiation phase of blood coagulation, and because they can activate all blood coagulation cascade, through the extrinsic, but also the intrinsic pathway. Blood activation initiated through FVII is first presented, as it is understood nowadays. Measurement of FVII and FVIIa were of main interest for epidemiological studies, but FVIIa contribution to assay results was only deduced. The introduction of specific FVIIa assays, functional or immunoassays, allowed measuring directly FVIIa without any interference of non-activated FVII, or other coagulation factors or their activated forms. The various methods available, and their characteristics are presented, with a special focus on two assays developed by our group for FVIIa (a clotting one and a chromogenic one). The FVIIa clotting assay shows evident superiority for measuring its activity in plasma, in pathophysiological conditions. The normal range is <2.5ng/ml, which represents less than 0.5% of the FVII protein. FVIIa is elevated in some pathological states. The chromogenic assay is of interest for assigning the potency of FVIIa concentrates, as it has a higher dynamic range. Both assays are fully automatable on laboratory instruments, and standardized in a satisfactory manner thanks to the use of the FVIIa concentrate WHO International Standard (NIBSC). The various applications and usefulness of FVIIa laboratory assays are discussed, for the measurement of therapeutic products, or for following recoveries in treated patients, including hemophiliacs with inhibitors, patients with severe bleeding risk (liver diseases, surgery, trauma, …), and lastly for measurement of its activity in therapeutic products.


Assuntos
Coagulação Sanguínea/fisiologia , Fator VIIa/metabolismo , Plasma/química , Fator VIIa/análise , Humanos
9.
Ann Biol Clin (Paris) ; 74(6): 735-746, 2016 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-27848925

RESUMO

Our study aimed to evaluate and validate according to standard NF EN ISO 15189 the original protocol ajustement of Hemoclot Protein C (PC) (Hyphen BioMed), clotting-based assay of PC on ACL TOP analyzer (Werfen/Instrumentation Laboratory). We evaluated the performance in terms of imprecision and we validate additional parameters in range B required by the SH GTA 04 (COFRAC): repeatability, reproducibility, detection and quantification limits, limits of linearity, stability, inter-samples and inter-reagents contamination, inaccuracy, evaluation of interferences (hemolysis, bilirubinemia and chyles). A comparison with Hemoclot PC on STA Compact analyzer (Stago) was performed. Coefficients of variation were lower than 5 %. Detection and quantification limits were respectively 8.3 % and 9.3 %. Superior limit of linearity was 140 %. The test didn't diplay any inter-samples and inter-reagents contamination. Reagent after reconstitution was stable 6 hours on ACL TOP. No interferences were observed for hemoglobin lower than 500 mg/dL, for bilirubin lower than and for chyles lower than 300 mg/dL. Comparison with Hemoclot PC on STA analyzer (Stago) was satisfactory. Hemoclot PC adjusted on ACL TOP analyzer showed satisfactory analytical performances with criteria chosen in our study. These data allow a better knowledge of the performances of this test and were useful to make a validation file in range B as recommended by SH GTA 04.


Assuntos
Automação Laboratorial/instrumentação , Proteína C/análise , Acreditação , Artefatos , Transtornos da Coagulação Sanguínea/sangue , Transtornos da Coagulação Sanguínea/diagnóstico , Testes de Coagulação Sanguínea/instrumentação , Testes de Coagulação Sanguínea/métodos , Testes de Coagulação Sanguínea/normas , Erros de Diagnóstico , Estabilidade de Medicamentos , Contaminação de Equipamentos , Humanos , Kit de Reagentes para Diagnóstico/normas , Reprodutibilidade dos Testes , Manejo de Espécimes/métodos
10.
Transfus Apher Sci ; 55(2): 249-261, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27692605

RESUMO

In the past decade Direct Oral Anti-Coagulants (DOACs), targeting Thrombin or Factor Xa, have enormously facilitated the daily treatment of all relevant patients, including those requiring lifelong therapy. These DOACs have considerable advantages over the use of oral Vitamin K Antagonist (VKA) treatments, in view of having little interferences with food and other medications and also not requiring adjustment for age, gender or weight, with some well-defined exceptions. In this current What's Happening Section we focus on measurements of DiXaIs in plasma using anti-Xa assays, with the objective of providing a tribute to Professor Michel Meyer Samama, who was not only a real leader in this field but, in the past, both authors benefited from his wisdom, as a teacher who dedicated his scientific and professional life (among many other interests in hemostasis, thrombosis and fibrinolysis) to develop and promote methods and strategies for laboratory monitoring of anticoagulants. This review presents the performance characteristics of the Anti-Factor Xa assays (measuring Factor Xa inhibition by drugs), which are available for measuring Direct Factor Xa Inhibitors in plasma, and show good compliance of the results with the reference LC:MS method (which measures the mass of Direct Factor Xa Inhibitors). We also present the preparation and validation of drug specific plasma calibrators and controls which are requested for drug measurements. These assays are convenient and practical laboratory tools which can be used in any laboratory setting, and meet the requirements of regulatory bodies for making smart, quantitative, sensitive, accurate and ease of use assays for measuring DOACs when needed. The manuscript focuses mainly on the following areas of current interest: interference in coagulation assays; anti-Xa laboratory methods; development of calibrators and controls for DiXaIs; method validation and comparison with reference techniques (LC:MS); regulatory requirements and method registrations; newer clinical applications and experience on DiXaIs with Anti-Xa assays, and future perspectives.


Assuntos
Bioensaio/métodos , Inibidores do Fator Xa/sangue , Fator Xa/metabolismo , Testes de Coagulação Sanguínea/métodos , Humanos
11.
Transfus Apher Sci ; 54(3): 428-37, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27216543

RESUMO

Use of Direct Oral Anticoagulants (DOACs) is continuously increasing for clinical application. The first product released was Dabigatran, which was proposed for many preventive and curative applications, especially for prevention of stroke in patients with non-valvular atrial fibrillation. Although measurement of Dabigatran Anti-IIa activity in plasma is not requested on a routine basis, in some situations its measurement is clinically useful. Especially, before an emergency surgery in treated patients, where its presence at high concentrations, which will expose the patient at an increased bleeding risk, has to be excluded. Hence, smart, specific, rapid and accurate quantitative assays are warranted as an essential required. Hemoclot™ Thrombin Inhibitors and Biophen® DTI were specifically designed for these applications, and can be used on all automated instruments with a standard range protocol for measuring concentrations at peak, or with a low range protocol for testing residual concentrations. Both functional assays have a good correlation with the reference LC-MS/MS method, and concentrations measured are similar. Performances of these assays and interferences of various substances or drugs are discussed. Some differences in variations of clotting times are observed between mechanical or optical clot detection instruments, which could be explained by the fibrin clot structure, altered by direct Factor Xa inhibitors, and more especially Rivaroxaban. Both clotting and chromogenic assays offer a safe and accurate quantitative measurement of Dabigatran in plasma in all situations where this determination is requested. In short this manuscript provides an in depth update on current opinions on laboratory aspects of measuring Dabigatran concentrations in plasma, when required.


Assuntos
Anticoagulantes/farmacocinética , Dabigatrana/farmacocinética , Administração Oral , Anticoagulantes/uso terapêutico , Dabigatrana/uso terapêutico , Humanos