Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Chromatogr B Analyt Technol Biomed Life Sci ; 878(17-18): 1420-5, 2010 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-20044318

RESUMO

In recent animal studies, several novel oxime compounds that are better than 2-PAM as antidotes against selected organophosphate (OP) nerve agents have been identified. The purpose of this study was to develop and validate a liquid chromatographic-mass spectrometric (LC-MS) method for analysis of the bis-pyridinium oxime ICD-585 (1-(2-hydroxyiminomethylpyridinium)-3-(4-carbamoylpyridinium)-propane) in plasma and to establish the utility of the method in a guinea pig model. Calibration curves were prepared using ICD-585-spiked plasma at concentrations from 0.156 to 10 microg/ml. Curves were run over a 1-month time frame and a total of 13 (n=13) were generated. The lower limit of quantification (LLOQ) was determined to be 0.216 microg/ml. Intra- and inter-day variability was assessed by studying precision and accuracy. For intra-day studies, data from the precision determinations indicated that the % CV's ranged from 4.28 to 14.98%. The % error in the accuracy assessments ranged from -8.73 to 4.61%. For inter-day studies, precision data ranged from 3.53 to 13.20%. The % error in the accuracy assessments ranged from 0.39 to 13.77%. Room temperature, freeze-thaw and autosampler stability was also examined. For all 3 stability studies, the compound remained within +/-15% of the initial analysis. Application of the method was demonstrated by analyzing samples from guinea pigs challenged with sarin (GB) or cyclosarin (GF) (1x LD(50)) followed with intramuscular ICD-585 (58 microM/kg, 21.8 mg/kg). At 55 min after oxime administration, mean (+/-SD) plasma concentrations were 15.98 (+/-4.88)microg/ml and 14.57 (+/-3.70) microg/ml in GB- and GF-exposed animals, respectively. In summary, studies have been carried out to verify the sensitivity, precision and accuracy of the assay as well as the stability of the analyte under various conditions. The method has been demonstrated to be applicable to the analysis of plasma from nerve agent-exposed guinea pigs.


Assuntos
Reativadores da Colinesterase/sangue , Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Oximas/sangue , Compostos de Piridínio/sangue , Animais , Calibragem , Reativadores da Colinesterase/administração & dosagem , Estabilidade de Medicamentos , Cobaias , Modelos Lineares , Modelos Animais , Oximas/administração & dosagem , Oximas/análise , Compostos de Piridínio/administração & dosagem , Compostos de Piridínio/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sus scrofa , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA