Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Am J Sports Med ; 47(14): 3491-3497, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31647881

RESUMO

BACKGROUND: Although numerous techniques of reconstruction of the medial ulnar collateral ligament (mUCL) have been described, limited evidence exists on the biomechanical implication of changing the ulnar tunnel position despite the fact that more recent literature has clarified that the ulnar footprint extends more distally than was appreciated in the past. PURPOSE: To evaluate the size and location of the native ulnar footprint and assess valgus stability of the medial elbow after UCL reconstruction at 3 ulnar tunnel locations. STUDY DESIGN: Controlled laboratory study. METHODS: Eighteen fresh-frozen cadaveric elbows were dissected to expose the mUCL. The anatomic footprint of the ulnar attachment of the mUCL was measured with a digitizing probe. The area of the ulnar footprint and midpoint relative to the joint line were determined. Medial elbow stability was tested with the mUCL in an intact, deficient, and reconstructed state after the docking technique, with ulnar tunnels placed at 5, 10, or 15 mm from the ulnotrochlear joint line. A 3-N·m valgus torque was applied to the elbow, and valgus rotation of the ulna was recorded via motion-tracking cameras as the elbow was cycled through a full range of motion. After kinematic testing, specimens were loaded to failure at 70° of elbow flexion. RESULTS: The mean ± SD length of the mUCL ulnar footprint was 27.4 ± 3.3 mm. The midpoint of the anatomic footprint was located between the 10- and 15-mm tunnels across all specimens at a mean 13.6 mm from the joint line. Sectioning of the mUCL increased elbow valgus rotation throughout all flexion angles and was statistically significant from 30° to 100° of flexion as compared with the intact elbow (P < .05). mUCL reconstruction at all 3 tunnel locations restored stability to near intact levels with no significant differences among the 3 ulnar tunnel locations at any flexion angle. CONCLUSION: Positioning the ulnar graft fixation site up to 15 mm from the ulnotrochlear joint line does not significantly increase valgus rotation in the elbow. CLINICAL RELEVANCE: A more distal ulnar tunnel may be a viable option to accommodate individual variation in morphology of the proximal ulna or in a revision setting.


Assuntos
Ligamento Colateral Ulnar/cirurgia , Ligamentos Colaterais/cirurgia , Articulação do Cotovelo/cirurgia , Reconstrução do Ligamento Colateral Ulnar/métodos , Fenômenos Biomecânicos , Cadáver , Ligamento Colateral Ulnar/patologia , Ligamentos Colaterais/patologia , Cotovelo/cirurgia , Articulação do Cotovelo/patologia , Humanos , Masculino , Amplitude de Movimento Articular , Torque , Ulna/cirurgia
2.
Anesthesiology ; 115(4): 774-81, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21394001

RESUMO

BACKGROUND: Whether the method of local anesthetic administration for continuous femoral nerve blocks--basal infusion versus repeated hourly bolus doses--influences block effects remains unknown. METHODS: Bilateral femoral perineural catheters were inserted in volunteers (n = 11). Ropivacaine 0.1% was concurrently administered through both catheters: a 6-h continuous 5 ml/h basal infusion on one side and 6 hourly bolus doses on the contralateral side. The primary endpoint was the maximum voluntary isometric contraction (MVIC) of the quadriceps femoris muscle at hour 6. Secondary endpoints included quadriceps MVIC at other time points, hip adductor MVIC, and cutaneous sensation 2 cm medial to the distal quadriceps tendon in the 22 h after initiation of local anesthetic administration. RESULTS: Quadriceps MVIC for limbs receiving 0.1% ropivacaine as a basal infusion declined by a mean (SD) of 84% (19) compared with 83% (24) for those receiving 0.1% ropivacaine as repeated bolus doses between baseline and hour 6 (paired t test P = 0.91). Intrasubject comparisons (left vs. right) also reflected a lack of difference: the mean basal-bolus difference in quadriceps MVIC at hour 6 was -1.1% (95% CI -22.0-19.8%). The similarity did not reach the a priori threshold for concluding equivalence, which was the 95% CI decreasing within ± 20%. There were similar minimal differences in the secondary endpoints during local anesthetic administration. CONCLUSIONS: This study did not find evidence to support the hypothesis that varying the method of local anesthetic administration--basal infusion versus repeated bolus doses--influences continuous femoral nerve block effects to a clinically significant degree.


Assuntos
Anestésicos Locais/administração & dosagem , Nervo Femoral , Movimento/efeitos dos fármacos , Bloqueio Nervoso/métodos , Sensação/efeitos dos fármacos , Adolescente , Adulto , Anestésicos Locais/farmacologia , Cateterismo , Estimulação Elétrica , Determinação de Ponto Final , Feminino , Lateralidade Funcional , Humanos , Bombas de Infusão , Contração Isométrica/efeitos dos fármacos , Masculino , Força Muscular/efeitos dos fármacos , Músculo Esquelético/efeitos dos fármacos , Tamanho da Amostra , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA