Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38756020

RESUMO

Industrial back support exoskeletons are a promising solution to alleviate lumbar musculoskeletal strain. Due to the complexity of spinal loading, evaluation of EMG data alone has been considered insufficient to assess their support effects, and complementary kinematic and dynamic data are required. However, the acquisition of marker-based kinematics is challenging with exoskeletons, as anatomical reference points, particularly on the pelvis, are occluded by exoskeleton structures. The aim of this study was therefore to develop and validate a method to reliably reconstruct the occluded pelvic markers. The movement data of six subjects, for whom pelvic markers could be placed while wearing an exoskeleton, were used to test the reconstructions and compare them to anatomical landmarks during lifting, holding and walking. Two separate approaches were used for the reconstruction. One used a reference coordinate system based on only exoskeleton markers (EXO), as has been suggested in the literature, while our proposed method adds a technical marker in the lumbar region (LUMB) to compensate for any shifting between exoskeleton and pelvis. Reconstruction with EXO yielded on average an absolute linear deviation of 54 mm ± 16 mm (mean ± 1SD) compared to anatomical markers. The additional marker in LUMB reduced mean deviations to 14 mm ± 7 mm (mean ± 1SD). Both methods were compared to reference values from the literature for expected variances due to marker placement and soft tissue artifacts. For LUMB 99% of reconstructions were within the defined threshold of 24 mm ±9 mm while for EXO 91% were outside.

2.
Sci Rep ; 9(1): 6188, 2019 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-30971709

RESUMO

A correction to this article has been published and is linked from the HTML and PDF versions of this paper. The error has not been fixed in the paper.

3.
Sci Rep ; 9(1): 182, 2019 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-30655583

RESUMO

Total knee arthroplasty aims to mimic the natural knee kinematics by optimizing implant geometry, but it is not clear how loading relates to tibio-femoral anterior-posterior translation or internal-external pivoting. We hypothesised that the point of pivot in the transverse plane is governed by the location of the highest axial force. Tibio-femoral loading was measured using an instrumented tibial component in six total knee arthroplasty patients (aged 65-80y, 5-7y post-op) during 5-6 squat repetitions, while knee kinematics were captured using a mobile video-fluoroscope. In the range of congruent tibio-femoral contact the medial femoral condyle remained approximately static while the lateral condyle translated posteriorly by 4.1 mm (median). Beyond the congruent range, the medial and lateral condyle motions both abruptly changed to anterior sliding by 4.6 mm, and 2.6 mm respectively. On average, both the axial loading and pivot position were more medial near extension, and transferred to the lateral side in flexion. However, no consistent relationship between pivoting and load distribution was found across all patients throughout flexion, with R2 values ranging from 0.00 to 0.65. Tibio-femoral kinematics is not related to the load distribution alone: medial loading of the knee does not necessarily imply a medial pivot location.


Assuntos
Artroplastia do Joelho/normas , Fêmur/fisiologia , Tíbia/fisiologia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Feminino , Fêmur/diagnóstico por imagem , Fluoroscopia/métodos , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiologia , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Rotação , Tíbia/diagnóstico por imagem , Suporte de Carga
4.
J Biomech ; 60: 197-202, 2017 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-28709659

RESUMO

The rising prevalence of osteoarthritis and an increase in total hip replacements calls for attention to potential therapeutic activities. Cycling is considered as a low impact exercise for the hip joint and hence recommended. However, there are limited data about hip joint loading to support this claim. The aim of this study was to measure synchronously the in vivo hip joint loads and pedal forces during cycling. The in vivo hip joint loads were measured in 5 patients with instrumented hip implants. Data were collected at several combinations of power and cadence, at two saddle heights. Joint loads and pedal forces showed strong linear correlation with power. So the relationship between the external pedal forces and internal joint forces was shown. While cycling at different cadences the minimum joint loads were acquired at 60RPM. The lower saddle height configuration results in an approximately 15% increase compared to normal saddle height. The results offered new insights into the actual effects of cycling on the hip joint and can serve as useful tools while developing an optimum cycling regimen for individuals with coxarthrosis or following total hip arthroplasty. Due to the relatively low contact forces, cycling at a moderate power level of 90W at a normal saddle height is suitable for patients.


Assuntos
Artroplastia de Quadril , Ciclismo/fisiologia , Articulação do Quadril/fisiologia , Idoso , Fenômenos Biomecânicos , Humanos , Masculino , Pessoa de Meia-Idade
5.
Bone Joint J ; 99-B(6): 779-787, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28566397

RESUMO

AIMS: Tibiofemoral alignment is important to determine the rate of progression of osteoarthritis and implant survival after total knee arthroplasty (TKA). Normally, surgeons aim for neutral tibiofemoral alignment following TKA, but this has been questioned in recent years. The aim of this study was to evaluate whether varus or valgus alignment indeed leads to increased medial or lateral tibiofemoral forces during static and dynamic weight-bearing activities. PATIENTS AND METHODS: Tibiofemoral contact forces and moments were measured in nine patients with instrumented knee implants. Medial force ratios were analysed during nine daily activities, including activities with single-limb support (e.g. walking) and double-limb support (e.g. knee bend). Hip-knee-ankle angles in the frontal plane were analysed using full-leg coronal radiographs. RESULTS: The medial force ratio strongly correlated with the tibiofemoral alignment in the static condition of one-legged stance (R² = 0.88) and dynamic single-limb loading (R² = 0.59) with varus malalignment leading to increased medial force ratios of up to 88%. In contrast, the correlation between leg alignment and magnitude of medial compartment force was much less pronounced. A lateral shift of force occurred during activities with double-limb support and higher knee flexion angles. CONCLUSION: The medial force ratio depends on both the tibiofemoral alignment and the nature of the activity involved. It cannot be generalised to a single value. Higher medial ratios during single-limb loading are associated with varus malalignment in TKA. The current trend towards a 'constitutional varus' after joint replacement, in terms of overall tibiofemoral alignment, should be considered carefully with respect to the increased medial force ratio. Cite this article: Bone Joint J 2017;99-B:779-87.


Assuntos
Artroplastia do Joelho/métodos , Mau Alinhamento Ósseo/fisiopatologia , Fêmur/fisiopatologia , Articulação do Joelho/fisiopatologia , Tíbia/fisiopatologia , Atividades Cotidianas , Idoso , Artroplastia do Joelho/efeitos adversos , Fenômenos Biomecânicos , Mau Alinhamento Ósseo/patologia , Feminino , Fêmur/patologia , Humanos , Articulação do Joelho/patologia , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular/fisiologia , Tíbia/patologia , Caminhada/fisiologia , Suporte de Carga/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA