Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
PLoS One ; 15(12): e0241779, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33315867

RESUMO

Accurate quantification and characterization of atherosclerotic plaques with MRI requires high spatial resolution acquisitions with excellent image quality. The intrinsically better signal-to-noise ratio (SNR) at high-field clinical 7T compared to the widely employed lower field strengths of 1.5 and 3T may yield significant improvements to vascular MRI. However, 7T atherosclerosis imaging also presents specific challenges, related to local transmit coils and B1 field inhomogeneities, which may overshadow these theoretical gains. We present the development and evaluation of 3D, black-blood, ultra-high resolution vascular MRI on clinical high-field 7T in comparison lower-field 3T. These protocols were applied for in vivo imaging of atherosclerotic rabbits, which are often used for development, testing, and validation of translatable cardiovascular MR protocols. Eight atherosclerotic New Zealand White rabbits were imaged on clinical 7T and 3T MRI scanners using 3D, isotropic, high (0.63 mm3) and ultra-high (0.43 mm3) spatial resolution, black-blood MR sequences with extensive spatial coverage. Following imaging, rabbits were sacrificed for validation using fluorescence imaging and histology. Image quality parameters such as SNR and contrast-to-noise ratio (CNR), as well as morphological and functional plaque measurements (plaque area and permeability) were evaluated at both field strengths. Using the same or comparable imaging parameters, SNR and CNR were in general higher at 7T compared to 3T, with a median (interquartiles) SNR gain of +40.3 (35.3-80.1)%, and a median CNR gain of +68.1 (38.5-95.2)%. Morphological and functional parameters, such as vessel wall area and permeability, were reliably acquired at 7T and correlated significantly with corresponding, widely validated 3T vessel wall MRI measurements. In conclusion, we successfully developed 3D, black-blood, ultra-high spatial resolution vessel wall MRI protocols on a 7T clinical scanner. 7T imaging was in general superior to 3T with respect to image quality, and comparable in terms of plaque area and permeability measurements.


Assuntos
Aterosclerose/diagnóstico , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Placa Aterosclerótica/diagnóstico por imagem , Animais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/lesões , Aorta Abdominal/patologia , Aterosclerose/etiologia , Aterosclerose/patologia , Dieta Hiperlipídica/efeitos adversos , Modelos Animais de Doenças , Estudos de Viabilidade , Humanos , Angiografia por Ressonância Magnética/instrumentação , Masculino , Placa Aterosclerótica/etiologia , Placa Aterosclerótica/patologia , Coelhos , Reprodutibilidade dos Testes , Razão Sinal-Ruído
2.
PLoS One ; 14(3): e0213642, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30889199

RESUMO

OBJECTIVE: To compare by 7 Tesla (7T) magnetic resonance imaging (MRI) in patients with focal epilepsy who have non-lesional clinical MRI scans with healthy controls. METHODS: 37 patients with focal epilepsy, based on clinical and electroencephalogram (EEG) data, with non-lesional MRIs at clinical field strengths and 21 healthy controls were recruited for the 7T imaging study. The MRI protocol consisted of high resolution T1-weighted, T2-weighted and susceptibility weighted imaging sequences of the entire cortex. The images were read by two neuroradiologists, who were initially blind to clinical data, and then reviewed a second time with knowledge of the seizure onset zone. RESULTS: A total of 25 patients had findings with epileptogenic potential. In five patients these were definitely related to their epilepsy, confirmed through surgical intervention, in three they co-localized to the suspected seizure onset zone and likely caused the seizures. In seven patients the imaging findings co-localized to the suspected seizure onset zone but were not the definitive cause, and ten had cortical lesions with epileptogenic potential that did not localize to the suspected seizure onset zone. There were multiple other findings of uncertain significance found in both epilepsy patients and healthy controls. The susceptibility weighted imaging sequence was instrumental in guiding more targeted inspection of the other structural images and aiding in the identification of cortical lesions. SIGNIFICANCE: Information revealed by the improved resolution and enhanced contrast provided by 7T imaging is valuable in noninvasive identification of lesions in epilepsy patients who are non-lesional at clinical field strengths.


Assuntos
Epilepsias Parciais/diagnóstico por imagem , Imageamento por Ressonância Magnética , Convulsões/diagnóstico por imagem , Adolescente , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Hipocampo/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Neuroimagem , Variações Dependentes do Observador , Radiologia , Estudos Retrospectivos , Adulto Jovem
3.
J Magn Reson Imaging ; 49(4): 994-1005, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30318674

RESUMO

BACKGROUND: The test-retest/interobserver repeatability and diagnostic value of 4D flow MRI in liver disease is underreported. PURPOSE: To determine the reproducibility/repeatability of flow quantification in abdominal vessels using a spiral 4D flow MRI sequence; to assess the value of 4D flow parameters in diagnosing cirrhosis and degree of portal hypertension. STUDY TYPE: Prospective. SUBJECTS: Fifty-two patients with chronic liver disease. FIELD STRENGTH/SEQUENCE: 1.5T/spiral 4D flow acquired in one breath-hold. ASSESSMENT: Thirteen abdominal vessels were identified and segmented by two independent observers to measure maximum and time-averaged through-plane velocity, net flow, and vessel cross-section area. Interobserver agreement and test-retest repeatability were evaluated in 15 and 4 cases, respectively. Prediction of the presence and severity of cirrhosis and portal hypertension was assessed using 4D flow parameters. STATISTICAL TESTS: Cohen's kappa coefficient, coefficient of variation (CV), Bland-Altman, Mann-Whitney tests, logistic regression. RESULTS: For all vessels combined, measurements showed acceptable agreement between observers, with Cohen's kappa = 0.70 (P < 0.001), CV < 21%, Bland-Altman bias <5%, but high limits of agreement ([-75%,75%]). Test-retest repeatability was excellent in large vessels (CV = 1-15%, bias = 1-25%, Bland-Altman limits of agreement [BALA] = [4%,150%]), and poor in small vessels (CV = 7-130%, bias = 10-200%, BALA = [8%,190%]). Average velocity in the right hepatic vein and average area of the splenic vein were higher in cirrhosis (P = 0.027/0.0039). Flow in the middle hepatic vein strongly correlated with Child-Pugh score (ρ = 0.84, P = 0.0238), while flow in the splenic vein (ρ = 0.43, P = 0.032), time-average (ρ = 0.46, P = 0.02) and peak velocity in the superior mesenteric vein (ρ = 0.45, P = 0.032), and peak velocity in the infrarenal IVC (ρ = 0.39, P = 0.032) positively correlated with an imaging-based portal hypertension score. Average area of the splenic vein predicted cirrhosis (P = 0.019; area under the curve AUC [95% confidence interval, CI] = 0.87 [0.71,1.00]) and clinically significant portal hypertension (P = 0.042; AUC [95% CI] = 0.78 [0.57-0.99]). DATA CONCLUSION: Spiral 4D flow allows comprehensive assessment of abdominal vessels in one breath-hold, with substantial interobserver reproducibility, but variable test-retest repeatability. 4D flow may potentially reflect vascular changes due to cirrhosis and portal hypertension. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:994-1005.


Assuntos
Doença Hepática Terminal/diagnóstico por imagem , Hemodinâmica , Hipertensão Portal/diagnóstico por imagem , Imageamento Tridimensional , Cirrose Hepática/diagnóstico por imagem , Imageamento por Ressonância Magnética , Abdome/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Fígado/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Análise de Regressão , Reprodutibilidade dos Testes
4.
NMR Biomed ; 31(7): e3940, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29856517

RESUMO

B1 inhomogeneity and chemical shift displacement error (CSDE) increase with the main magnetic field strength and are therefore deleterious for magnetic resonance spectroscopy (MRS) at ultrahigh field. A solution is to use adiabatic pulses which operate over a broad range of B1 and thus are insensitive to B1 inhomogeneity. Moreover, adiabatic pulses usually have a relatively higher bandwidth, which makes CSDE low to negligible. The use of exclusively adiabatic pulses for single-voxel spectroscopy (SVS) typically brings the disadvantage of a long echo time (TE), but the advantage of a low and matched CSDE. Herein, we took advantage of short-duration, low-power, matched-phase adiabatic spin echo (MASE) pulses to implement a matched CSDE semi-localized by adiabatic selective refocusing (sLASER) sequence capable of attaining short TEs, while CSDE is matched and still comparatively low. We also demonstrate here the feasibility of the direct measurement of the γ-aminobutyric acid (GABA) resonance at 2.28 ppm well separated from the neighboring glutamate resonance at 7 T using the implemented MASE-sLASER sequence at TEs of 68 and 136 ms. The shorter duration of MASE pulses also made it possible to implement a Mescher-Garwood-semi-localized by adiabatic selective refocusing (MEGA-sLASER) (with MASE) sequence with TE = 68 ms for editing GABA at 7 T, the results for which are also shown.


Assuntos
Espectroscopia de Ressonância Magnética , Marcadores de Spin , Adulto , Simulação por Computador , Ácido Glutâmico/metabolismo , Humanos , Masculino , Metaboloma , Fatores de Tempo , Ácido gama-Aminobutírico/metabolismo
5.
World Neurosurg ; 103: 600-610, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28359922

RESUMO

BACKGROUND: Successful endoscopic endonasal surgery for the resection of skull base tumors is reliant on preoperative imaging to delineate pathology from the surrounding anatomy. The increased signal-to-noise ratio afforded by 7-T MRI can be used to increase spatial and contrast resolution, which may lend itself to improved imaging of the skull base. In this study, we apply a 7-T imaging protocol to patients with skull base tumors and compare the images with clinical standard of care. METHODS: Images were acquired at 7 T on 11 patients with skull base lesions. Two neuroradiologists evaluated clinical 1.5-, 3-, and 7-T scans for detection of intracavernous cranial nerves and internal carotid artery (ICA) branches. Detection rates were compared. Images were used for surgical planning and uploaded to a neuronavigation platform and used to guide surgery. RESULTS: Image analysis yielded improved detection rates of cranial nerves and ICA branches at 7 T. The 7-T images were successfully incorporated into preoperative planning and intraoperative neuronavigation. CONCLUSIONS: Our study represents the first application of 7-T MRI to the full neurosurgical workflow for endoscopic endonasal surgery. We detected higher rates of cranial nerves and ICA branches at 7-T MRI compared with 3- and 1.5-T MRI, and found that integration of 7 T into surgical planning and guidance was feasible. These results suggest a potential for 7-T MRI to reduce surgical complications. Future studies comparing standardized 7-, 3-, and 1.5-T MRI protocols in a larger number of patients are warranted to determine the relative benefit of 7-T MRI for endonasal endoscopic surgical efficacy.


Assuntos
Adenoma/diagnóstico por imagem , Craniofaringioma/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Neoplasias Meníngeas/diagnóstico por imagem , Meningioma/diagnóstico por imagem , Neuroendoscopia/métodos , Neoplasias Hipofisárias/diagnóstico por imagem , Neoplasias da Base do Crânio/diagnóstico por imagem , Cirurgia Assistida por Computador/métodos , Adenoma/cirurgia , Adulto , Craniofaringioma/cirurgia , Feminino , Humanos , Masculino , Neoplasias Meníngeas/cirurgia , Meningioma/cirurgia , Pessoa de Meia-Idade , Cirurgia Endoscópica por Orifício Natural , Neuronavegação/métodos , Neoplasias Hipofisárias/cirurgia , Neoplasias da Base do Crânio/cirurgia
6.
Eur J Radiol Open ; 3: 1-7, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27069971

RESUMO

PURPOSE: To correlate intra voxel incoherent motion (IVIM) diffusion parameters of liver parenchyma and hepatocellular carcinoma (HCC) with degree of liver/tumor enhancement and necrosis; and to assess the diagnostic performance of diffusion parameters vs. enhancement ratios (ER) for prediction of complete tumor necrosis. PATIENTS AND METHODS: In this IRB approved HIPAA compliant study, we included 46 patients with HCC who underwent IVIM diffusion-weighted (DW) MRI in addition to routine sequences at 3.0 T. True diffusion coefficient (D), pseudo-diffusion coefficient (D*), perfusion fraction (PF) and apparent diffusion coefficient (ADC) were quantified in tumors and liver parenchyma. Tumor ER were calculated using contrast-enhanced imaging, and degree of tumor necrosis was assessed using post-contrast image subtraction. IVIM parameters and ER were compared between HCC and background liver and between necrotic and viable tumor components. ROC analysis for prediction of complete tumor necrosis was performed. RESULTS: 79 HCCs were assessed (mean size 2.5 cm). D, PF and ADC were significantly higher in HCC vs. liver (p < 0.0001). There were weak significant negative/positive correlations between D/PF and ER, and significant correlations between D/PF/ADC and tumor necrosis (for D, r 0.452, p < 0.001). Among diffusion parameters, D had the highest area under the curve (AUC 0.811) for predicting complete tumor necrosis. ER outperformed diffusion parameters for prediction of complete tumor necrosis (AUC > 0.95, p < 0.002). CONCLUSION: D has a reasonable diagnostic performance for predicting complete tumor necrosis, however lower than that of contrast-enhanced imaging.

7.
J Magn Reson Imaging ; 44(2): 317-26, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26855407

RESUMO

PURPOSE: To assess the correlation between each of intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) metrics in renal parenchyma with renal function, in a cohort of patients with chronic liver disease. MATERIALS AND METHODS: Thirty patients with liver disease underwent abdominal MRI at 1.5T, including a coronal respiratory-triggered IVIM-DWI sequence and a coronal 3D FLASH DCE-MRI acquisition. Diffusion signals in the renal cortex and medulla were fitted to the IVIM model to estimate the diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (PF). The apparent diffusion coefficient (ADC) was calculated using all b-values. The glomerular filtration rate (GFR), cortical and medullary renal plasma flow (RPF), mean transit times (MTT) of vascular and tubular compartments and the whole kidney, were calculated from DCE-MRI data by fitting to a three-compartment model. The estimated GFR (eGFR) was calculated from serum creatinine measured 30 ± 27 days of MRI. RESULTS: ADC, PF, and RPF were significantly higher in renal cortex vs. medulla (P < 10(-5) ). DCE-MRI GFR significantly correlated with, but underestimated, eGFR (Spearman's r/P = 0.49/0.01). IVIM-DWI parameters were not significantly correlated with eGFR. DCE-MRI GFR correlated weakly with D (cortex, r/P = 0.3/0.03; medulla r/P = 0.27/0.05) and ADC (cortex r/P = 0.28/0.04; medulla r/P = 0.34/0.01). Weak correlations were observed for pooled cortical and medullar RPF with PF (r/P = 0.32/10(-3) ) and with ADC (r/P = 0.29/0.0025). Significant negative correlations were observed for vascular MTT with cortical D* (r/P = -0.38/0.004) and D*×PF (r/P = -0.34/0.01). CONCLUSION: The weak correlations between renal IVIM and DCE-MRI perfusion parameters imply that these functional measures could be complementary. J. Magn. Reson. Imaging 2016;44:317-326.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Testes de Função Renal/métodos , Rim/diagnóstico por imagem , Rim/fisiopatologia , Meglumina/análogos & derivados , Compostos Organometálicos , Adulto , Idoso , Algoritmos , Simulação por Computador , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Modelos Estatísticos , Movimento (Física) , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
J Magn Reson Imaging ; 44(4): 856-64, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-26919327

RESUMO

PURPOSE: To assess the correlation between intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) metrics in hepatocellular carcinoma (HCC) and liver parenchyma. MATERIALS AND METHODS: Twenty-five patients with HCC (M/F 23/2, mean age 58 years) underwent abdominal MRI at 1.5 or 3.0T, including IVIM-DWI (with 16 b-values) and DCE-MRI (3D FLASH sequence, mean temporal resolution of 2.3 sec). IVIM-DWI parameters (pseudodiffusion coefficient, D*, diffusion coefficient, D, and perfusion fraction, PF) were quantified in HCC lesions and liver parenchyma using a Bayesian fitting algorithm. DCE-MRI parameters (arterial flow, Fa , portal flow, Fp , total flow, Ft , mean transit time, MTT, distribution volume, DV, and arterial fraction, ART) were quantified using a dual-input single-compartment model. Correlations between IVIM-DWI and DCE-MRI parameters were assessed using a Spearman correlation test. RESULTS: Thirty-three HCC lesions (average size 5.0 ± 3.6 cm) were analyzed. D, D*, and PF were all significantly lower in HCC vs. liver (P < 0.05). Significantly higher Fa and ART and lower Fp were observed in HCC vs. liver (P < 0.001). Significant moderate to strong negative correlations were observed between ART and D* (r = -0.443, P = 0.028), ART and PF (r = -0.536, P = 0.006), ART and PFxD* (r = -0.655, P < 0.001), Fa and PF (r = 0.455, P = 0.023), and Fa and PFxD* (r = -0.475, P = 0.018) in liver parenchyma. There was no significant correlation between IVIM-DWI and DCE-MRI metrics in HCC lesions. CONCLUSION: IVIM-DWI and DCE-MRI provide nonredundant information in HCC, while they correlate in liver parenchyma. These findings may be secondary to predominant portal inflow in the liver and tortuous vasculature and tissue heterogeneity in tumors. J. MAGN. RESON. IMAGING 2016;44:856-864.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Adulto , Idoso , Algoritmos , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Liver Int ; 36(5): 659-66, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26744140

RESUMO

BACKGROUND & AIMS: Establishing accurate non-invasive methods of liver fibrosis quantification remains a major unmet need. Here, we assessed the diagnostic value of a multiparametric magnetic resonance imaging (MRI) protocol including diffusion-weighted imaging (DWI), dynamic contrast-enhanced (DCE)-MRI and magnetic resonance elastography (MRE) in comparison with transient elastography (TE) and blood tests [including ELF (Enhanced Liver Fibrosis) and APRI] for liver fibrosis detection. METHODS: In this single centre cross-sectional study, we prospectively enrolled 60 subjects with liver disease who underwent multiparametric MRI (DWI, DCE-MRI and MRE), TE and blood tests. Correlation was assessed between non-invasive modalities and histopathologic findings including stage, grade and collagen content, while accounting for covariates such as age, sex, BMI, HCV status and MRI-derived fat and iron content. ROC curve analysis evaluated the performance of each technique for detection of moderate-to-advanced liver fibrosis (F2-F4) and advanced fibrosis (F3-F4). RESULTS: Magnetic resonance elastography provided the strongest correlation with fibrosis stage (r = 0.66, P < 0.001), inflammation grade (r = 0.52, P < 0.001) and collagen content (r = 0.53, P = 0.036). For detection of moderate-to-advanced fibrosis (F2-F4), AUCs were 0.78, 0.82, 0.72, 0.79, 0.71 for MRE, TE, DCE-MRI, DWI and APRI, respectively. For detection of advanced fibrosis (F3-F4), AUCs were 0.94, 0.77, 0.79, 0.79 and 0.70, respectively. CONCLUSIONS: Magnetic resonance elastography provides the highest correlation with histopathologic markers and yields high diagnostic performance for detection of advanced liver fibrosis and cirrhosis, compared to DWI, DCE-MRI, TE and serum markers.


Assuntos
Biomarcadores/sangue , Imagem de Difusão por Ressonância Magnética , Técnicas de Imagem por Elasticidade , Cirrose Hepática/diagnóstico por imagem , Adulto , Área Sob a Curva , Estudos Transversais , Feminino , Humanos , Fígado/patologia , Cirrose Hepática/sangue , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , New York , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Centros de Atenção Terciária
10.
Magn Reson Med ; 75(5): 1949-57, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26041650

RESUMO

PURPOSE: To improve ultrahigh field diffusion-weighted imaging (DWI) in the presence of inhomogeneous transmit B1 field by designing a novel semi-adiabatic single-refocused DWI technique. METHODS: A 180° slice-selective, adiabatic radiofrequency (RF) pulse of 4 ms duration was designed using the adiabatic Shinnar-Le Roux algorithm. A matched-phase slice-selective 90° RF pulse of 8 ms duration was designed to compensate the nonlinear phase of the adiabatic 180° RF pulse. The resulting RF pulse combination, matched-phase adiabatic spin echo (MASE), was integrated into a single-shot echo planar DWI sequence. The performance of this sequence was compared with single-refocused Stejskal-Tanner (ST), twice-refocused spin echo (TRSE) and twice-refocused adiabatic spin echo (TRASE) in simulations, phantoms, and healthy volunteers at 7 Tesla (T). RESULTS: In regions with inhomogeneous B1 , MASE resulted in increased signal intensity compared with ST (up to 64%). Moderate increase in specific absorption rate (35-39%) was observed for adiabatic RF pulses. MASE resulted in higher signal homogeneity at 7T, leading to improved visualization of measures derived from diffusion-weighted images such as white matter tractography and track density images. CONCLUSION: Efficient adiabatic SLR pulses can be adapted to single-refocused DWI, leading to substantially improved signal uniformity when compared with conventional acquisitions.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Algoritmos , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Calibragem , Simulação por Computador , Imagem Ecoplanar , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Ondas de Rádio , Razão Sinal-Ruído , Substância Branca/diagnóstico por imagem , Substância Branca/fisiologia
11.
World Neurosurg ; 86: 450-65, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26409071

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) is the imaging modality of choice for the clinical management of brain tumors, and the majority of scanners operate with static magnetic field strengths of 1.5 or 3.0 Tesla (T). During the past decade, ultrahigh field (UHF) MRI has been investigated for its clinical applicability. This meta-analysis evaluates studies pertaining to the application of UHF MRI to patients with brain tumors. METHODS: The authors performed a systematic review of the literature. Articles relating to application of UHF MRI to brain anatomy and brain tumors with living subjects were included. Studies were grouped into 1 of 3 categories based on area of focus: "Anatomical Structures Involved with Brain Tumors," "Tumor characterization," and "Treatment Monitoring." Comparison studies with extractable outcomes measure data were analyzed for performance of UHF MRI versus clinical field strengths (1.5 T and 3 T). RESULTS: Twenty-four studies (361 subjects) met inclusion criteria. The field of study was heterogeneous and rigorous statistical analysis was not possible. Overall, 279 patients with brain tumors scanned at UHF MRI have been reported. Of these, glioma and glioblastoma multiforme are the most commonly studied lesions (38.9% and 24.4%, respectively). In comparison studies between UHF MRI and clinical field strengths, 24 of 51 patients had outcome measures that were better with UHF MRI, 17 of 24 were equivalent at both field strengths, and 9 were worse at UHF MRI. The most common causes of a worse performance were susceptibility artifacts and magnetic field inhomogeneities (3 of 9). Imaging of the pituitary gland, pineal gland veins, cranial nerves, and tumor microvasculature were all shown to be feasible. CONCLUSIONS: UHF MRI shows promise to improve detection and characterization of brain tumors, preoperative planning for neurosurgical resection, and longitudinal monitoring of the effects of radiation and antibody-based therapies. Technical innovations are needed to overcome field inhomogeneity and susceptibility artifacts in certain regions of the skull. Finally, larger studies comparing 1.5 T, 3.0 T, and 7.0 T or greater will determine whether UHF MRI gains acceptance as a clinical standard.


Assuntos
Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/terapia , Imageamento por Ressonância Magnética , Humanos
12.
Magn Reson Med ; 76(6): 1741-1749, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-26619960

RESUMO

PURPOSE: At high field, T2 -weighted (T2 w) imaging is limited by transmit field inhomogeneity and increased radiofrequency power deposition. In this work, we introduce SAMPA (Slice-selective Adiabatic Magnetization T2 PrepAration) and demonstrate its use for efficient brain T2 w imaging at 7 Tesla (T). METHODS: SAMPA was designed by subsampling an optimized B1 insensitive rotation (BIR4) waveform with small tip angle linear subpulses. To perform T2 w imaging, SAMPA was inserted before a fast gradient echo acquisition. The off-resonance behavior, B1 robustness, and slice selectivity of the novel T2 preparation module were analyzed using Bloch simulations. The performance of SAMPA for T2 w imaging was demonstrated in phantom experiments as well as in the brains of healthy volunteers at 7T. RESULTS: Based on simulations, the proposed design operates at peak B1 of 15 µT and higher, within a 400 Hz bandwidth. T2 values were in strong agreement with spin echo-based T2 mapping in phantom experiments. Whole brain, interleaved multislab three-dimensional imaging could be acquired with 0.8 mm3 isotropic resolution in 5:36 min per T2 weighting. CONCLUSION: Compared with previous adiabatic T2 preparation techniques, SAMPA allows for slice-selectivity, which can lead to efficient and robust acquisitions for T2 w imaging at high field. Magn Reson Med 76:1741-1749, 2016. © 2015 International Society for Magnetic Resonance in Medicine.


Assuntos
Algoritmos , Encéfalo/anatomia & histologia , Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Sinais Assistido por Computador , Humanos , Imagens de Fantasmas , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
MAGMA ; 29(1): 49-58, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26646522

RESUMO

OBJECTIVE: To quantify hepatocellular carcinoma (HCC) perfusion and flow with the fast exchange regime-allowed Shutter-Speed model (SSM) compared to the Tofts model (TM). MATERIALS AND METHODS: In this prospective study, 25 patients with HCC underwent DCE-MRI. ROIs were placed in liver parenchyma, portal vein, aorta and HCC lesions. Signal intensities were analyzed employing dual-input TM and SSM models. ART (arterial fraction), K (trans) (contrast agent transfer rate constant from plasma to extravascular extracellular space), ve (extravascular extracellular volume fraction), kep (contrast agent intravasation rate constant), and τi (mean intracellular water molecule lifetime) were compared between liver parenchyma and HCC, and ART, K (trans), v e and k ep were compared between models using Wilcoxon tests and limits of agreement. Test-retest reproducibility was assessed in 10 patients. RESULTS: ART and v e obtained with TM; ART, ve, ke and τi obtained with SSM were significantly different between liver parenchyma and HCC (p < 0.04). Parameters showed variable reproducibility (CV range 14.7-66.5% for both models). Liver K (trans) and ve; HCC ve and kep were significantly different when estimated with the two models (p < 0.03). CONCLUSION: Our results show differences when computed between the TM and the SSM. However, these differences are smaller than parameter reproducibilities and may be of limited clinical significance.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Idoso , Algoritmos , Artérias/diagnóstico por imagem , Artérias/patologia , Humanos , Processamento de Imagem Assistida por Computador , Fígado/diagnóstico por imagem , Masculino , Perfusão , Estudos Prospectivos , Reprodutibilidade dos Testes , Água/química
14.
Eur J Radiol Open ; 2: 123-128, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26393236

RESUMO

PURPOSE: To compare intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) of the liver between 1.5T and 3.0 T in terms of parameter quantification and inter-platform reproducibility. MATERIALS AND METHODS: In this IRB approved prospective study, 19 subjects (17 patients with chronic liver disease and 2 healthy volunteers) underwent two repeat scans at 1.5T and 3.0T. Each scan included IVIM DWI using 16 b values from 0 to 800 s/mm2. A single observer measured IVIM parameters for each platform and estimated signal to noise ratio (eSNR) at b0, 200, 400 and 800 s/mm2. Wilcoxon paired tests were used to compare liver eSNR and IVIM parameters. Inter-platform reproducibility was assessed by calculating within-subject coefficient of variation (CV) and Bland-Altman limits of agreement. An ice water phantom was used to test ADC variability between the two MRI systems. RESULTS: The mean invitro difference in ADC between the two platforms was 6.8%. eSNR was significantly higher at 3.0T for all selected b values (p=0.006-0.020), except for b0 (p=0.239). Liver IVIM parameters were significantly different between 1.5T and 3.0T (p=0.005-0.044), except for ADC (p=0.748). The inter-platform reproducibility of true diffusion coefficient (D) and ADC were good, with mean CV of 10.9% and 11.1%, respectively. Perfusion fraction (PF) and pseudodiffusion coefficient (D*) showed more limited inter-platform reproducibility (mean CV of 22.6% for PF and 46.9% for D*). CONCLUSION: Liver D and ADC values showed good reproducibility between 1.5T and 3.0T platforms; while there was more variability in PF, and large variability in D* parameters between the two platforms. These findings may have implications for drug trials assessing the role of IVIM DWI in tumor response and liver fibrosis.

15.
NMR Biomed ; 28(10): 1304-14, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26332103

RESUMO

Atherosclerotic plaques that cause stroke and myocardial infarction are characterized by increased microvascular permeability and inflammation. Dynamic contrast-enhanced MRI (DCE-MRI) has been proposed as a method to quantify vessel wall microvascular permeability in vivo. Until now, most DCE-MRI studies of atherosclerosis have been limited to two-dimensional (2D) multi-slice imaging. Although providing the high spatial resolution required to image the arterial vessel wall, these approaches do not allow the quantification of plaque permeability with extensive anatomical coverage, an essential feature when imaging heterogeneous diseases, such as atherosclerosis. To our knowledge, we present the first systematic evaluation of three-dimensional (3D), high-resolution, DCE-MRI for the extensive quantification of plaque permeability along an entire vascular bed, with validation in atherosclerotic rabbits. We compare two acquisitions: 3D turbo field echo (TFE) with motion-sensitized-driven equilibrium (MSDE) preparation and 3D turbo spin echo (TSE). We find 3D TFE DCE-MRI to be superior to 3D TSE DCE-MRI in terms of temporal stability metrics. Both sequences show good intra- and inter-observer reliability, and significant correlation with ex vivo permeability measurements by Evans Blue near-infrared fluorescence (NIRF). In addition, we explore the feasibility of using compressed sensing to accelerate 3D DCE-MRI of atherosclerosis, to improve its temporal resolution and therefore the accuracy of permeability quantification. Using retrospective under-sampling and reconstructions, we show that compressed sensing alone may allow the acceleration of 3D DCE-MRI by up to four-fold. We anticipate that the development of high-spatial-resolution 3D DCE-MRI with prospective compressed sensing acceleration may allow for the more accurate and extensive quantification of atherosclerotic plaque permeability along an entire vascular bed. We foresee that this approach may allow for the comprehensive and accurate evaluation of plaque permeability in patients, and may be a useful tool to assess the therapeutic response to approved and novel drugs for cardiovascular disease.


Assuntos
Aorta Abdominal/patologia , Doenças da Aorta/patologia , Permeabilidade Capilar , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Placa Aterosclerótica/patologia , Animais , Meios de Contraste , Modelos Animais de Doenças , Estudos de Viabilidade , Variações Dependentes do Observador , Coelhos
16.
AJR Am J Roentgenol ; 204(3): 510-8, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25714279

RESUMO

OBJECTIVE. The objective of our study was to evaluate the performance of a high-spatial-resolution 2D phase-contrast (PC) MRI technique accelerated with compressed sensing for portal vein (PV) and hepatic artery (HA) flow quantification in comparison with a standard PC MRI sequence. SUBJECTS AND METHODS. In this prospective study, two PC MRI sequences were compared, one with parallel imaging acceleration and low spatial resolution (generalized autocalibrating partial parallel acquisition [GRAPPA]) and one with compressed sensing acceleration and high spatial resolution (sparse). Seventy-six patients were assessed, including 37 patients with cirrhosis. Two observers evaluated PC image quality. Quantitative analyses yielded a mean velocity, flow, and vessel area for the PV and HA and an arterial fraction. The PC techniques were compared using the paired Wilcoxon test and Bland-Altman statistics. The sensitivity of the flow parameters to the severity of cirrhosis was also assessed. RESULTS. Vessel delineation was significantly improved using the PC sparse sequence (p < 0.034). For both in vitro and in vivo measurements, PC sparse yielded lower estimates for vessel area and flow, and larger differences between PC GRAPPA and PC sparse were observed in the HA. PV velocity and flow were significantly lower in patients with cirrhosis on both PC sparse (p < 0.001 and p = 0.042, respectively) and PC GRAPPA (p < 0.001 and p = 0.005, respectively). PV velocity correlated negatively with Child-Pugh class (r = -0.50, p < 0.001), whereas the arterial fraction measured with PC sparse was higher in patients with Child-Pugh class B or C disease than in those with Child-Pugh class A disease, with a trend toward significance (p = 0.055). CONCLUSION. A high-spatial-resolution highly accelerated compressed sensing technique (PC sparse) allows total hepatic blood flow measurements obtained in 1 breath-hold, provides improved delineation of the hepatic vessels compared with a standard PC MRI sequence (GRAPPA), and can potentially be used for the noninvasive assessment of liver cirrhosis.


Assuntos
Artéria Hepática/fisiologia , Cirrose Hepática/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Veia Porta/fisiologia , Fluxo Sanguíneo Regional , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
17.
Abdom Imaging ; 40(4): 803-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25294006

RESUMO

PURPOSE: To compare MR elastography (MRE) using a single and a dual driver excitation for the quantification of hepatic and splenic stiffness (HS and SS), and to investigate the performance of HS and SS measured with single or dual driver excitation for the detection of liver cirrhosis in subjects with liver disease. PATIENTS AND METHODS: This prospective HIPAA compliant and IRB approved study involved 49 subjects who underwent MRE at 3.0T, comparing three different acquisition methods (single driver on the liver, single driver on the spleen and dual driver acoustic excitation). A Mann-Whitney test was used to assess changes in stiffness values. Bland-Altman analysis was used to compare single and dual driver configurations for each organ. Performance for detection of liver cirrhosis was assessed using ROC analysis. Pearson correlation was used to estimate the dependence of HS and SS on spleen size. RESULTS: There were 40 noncirrhotic and 9 cirrhotic patients. There was good agreement between stiffness values measured with a single or a dual driver (Bland-Altman limits of agreement -14.3 % to 18.9 % and -18.1 % to 29.7 %, CV 6.4 % and 9.4 %, for HS and SS. respectively). HS and SS were higher in subjects with liver cirrhosis (p < 0.001), with excellent detection performance (AUROC range 0.87-0.93). SS correlated strongly with spleen size (r = 0.69, p < 0.001), while HS showed weak correlation (r = 0.38, p = 0.006). CONCLUSION: Using a dual acoustic driver configuration, hepatic and splenic stiffness can be simultaneously estimated with good concordance with single driver measurement.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/patologia , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Baço/patologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Adulto Jovem
18.
Radiology ; 275(1): 245-54, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25325326

RESUMO

PURPOSE: To develop a highly accelerated phase-contrast cardiac-gated volume flow measurement (four-dimensional [4D] flow) magnetic resonance (MR) imaging technique based on spiral sampling and dynamic compressed sensing and to compare this technique with established phase-contrast imaging techniques for the quantification of blood flow in abdominal vessels. MATERIALS AND METHODS: This single-center prospective study was compliant with HIPAA and approved by the institutional review board. Ten subjects (nine men, one woman; mean age, 51 years; age range, 30-70 years) were enrolled. Seven patients had liver disease. Written informed consent was obtained from all participants. Two 4D flow acquisitions were performed in each subject, one with use of Cartesian sampling with respiratory tracking and the other with use of spiral sampling and a breath hold. Cartesian two-dimensional (2D) cine phase-contrast images were also acquired in the portal vein. Two observers independently assessed vessel conspicuity on phase-contrast three-dimensional angiograms. Quantitative flow parameters were measured by two independent observers in major abdominal vessels. Intertechnique concordance was quantified by using Bland-Altman and logistic regression analyses. RESULTS: There was moderate to substantial agreement in vessel conspicuity between 4D flow acquisitions in arteries and veins (κ = 0.71 and 0.61, respectively, for observer 1; κ = 0.71 and 0.44 for observer 2), whereas more artifacts were observed with spiral 4D flow (κ = 0.30 and 0.20). Quantitative measurements in abdominal vessels showed good equivalence between spiral and Cartesian 4D flow techniques (lower bound of the 95% confidence interval: 63%, 77%, 60%, and 64% for flow, area, average velocity, and peak velocity, respectively). For portal venous flow, spiral 4D flow was in better agreement with 2D cine phase-contrast flow (95% limits of agreement: -8.8 and 9.3 mL/sec, respectively) than was Cartesian 4D flow (95% limits of agreement: -10.6 and 14.6 mL/sec). CONCLUSION: The combination of highly efficient spiral sampling with dynamic compressed sensing results in major acceleration for 4D flow MR imaging, which allows comprehensive assessment of abdominal vessel hemodynamics in a single breath hold.


Assuntos
Abdome/irrigação sanguínea , Aumento da Imagem/métodos , Adulto , Idoso , Algoritmos , Suspensão da Respiração , Meios de Contraste , Compressão de Dados , Feminino , Hemodinâmica , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Software
19.
J Magn Reson Imaging ; 41(1): 149-56, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24415565

RESUMO

PURPOSE: To evaluate short-term test-retest and interobserver reproducibility of IVIM (intravoxel incoherent motion) diffusion parameters and ADC (apparent diffusion coefficient) of hepatocellular carcinoma (HCC) and liver parenchyma at 3.0T. MATERIALS AND METHODS: In this prospective Institutional Review Board (IRB)-approved study, 11 patients were scanned twice using a free-breathing single-shot echo-planar-imaging, diffusion-weighted imaging (DWI) sequence using 4 b values (b = 0, 50, 500, 1000 s/mm(2)) and IVIM DWI using 16 b values (0-800 s/mm(2)) at 3.0T. IVIM parameters (D: true diffusion coefficient, D*: pseudodiffusion coefficient, PF: perfusion fraction) and ADC (using 4 b and 16 b) were calculated. Short-term test-retest and interobserver reproducibility of IVIM parameters and ADC were assessed by measuring correlation coefficient, coefficient of variation (CV), and Bland-Altman limits of agreements (BA-LA). RESULTS: Fifteen HCCs were assessed in 10 patients. Reproducibility of IVIM metrics in HCC was poor for D* and PF (mean CV 60.6% and 37.3%, BA-LA: -161.6% to 135.3% and -66.2% to 101.0%, for D* and PF, respectively), good for D and ADC (CV 19.7% and <16%, BA-LA -57.4% to 36.3% and -38.2 to 34.1%, for D and ADC, respectively). Interobserver reproducibility was on the same order of test-retest reproducibility except for PF in HCC. Reproducibility of diffusion parameters was better in liver parenchyma compared to HCC. CONCLUSION: Poor reproducibility of D*/PF and good reproducibility for D/ADC were observed in HCC and liver parenchyma. These findings may have implications for trials using DWI in HCC.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico , Movimento (Física) , Adulto , Idoso , Meios de Contraste , Gadolínio DTPA , Humanos , Aumento da Imagem , Fígado/patologia , Masculino , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Variações Dependentes do Observador , Compostos Organometálicos , Estudos Prospectivos , Reprodutibilidade dos Testes
20.
AJR Am J Roentgenol ; 204(1): 59-68, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25539238

RESUMO

OBJECTIVE: The objective of our study was to compare diffusion-weighted imaging (DWI) sequences using a bipolar versus a monopolar single-shot echo-planar imaging (EPI) gradient design for image quality and for lesion detection and characterization in patients with liver disease. MATERIALS AND METHODS: In this retrospective study, 77 patients with chronic liver disease who underwent MRI including bipolar and monopolar DWI at 1.5 T were assessed. Two independent observers reviewed the DWI studies for image quality and the detection and characterization of liver lesions. The reference standard for diagnosis was established by consensus review of two different observers using imaging characteristics on conventional MRI sequences, lesion stability over time, pathologic correlation, or a combination of these findings. The estimated signal-to-noise ratio (SNR) of liver parenchyma and apparent diffusion coefficients (ADCs) of the liver and lesions were calculated for both sequences. ROC analysis was conducted to evaluate the performance of ADC for the diagnosis of hepatocellular carcinoma (HCC). RESULTS: Eighty-five lesions, 50 HCCs and 35 benign lesions, were detected with the reference standard in 38 patients. There was equivalent image quality for the bipolar and monopolar sequences (p = 0.24-0.42). The HCC detection rate for observers 1 and 2 was slightly better with bipolar DWI (50.0% and 52.0%, respectively) compared with monopolar DWI (44.0% and 46.0%); however, this difference did not reach statistical significance. The estimated SNR was higher with the monopolar sequence than with the bipolar sequence (p ≤ 0.001). The AUC for the ROC curve was 0.691 for bipolar DWI and 0.649 for monopolar DWI when ADC was used for the characterization of HCC, which is not a statistically significant difference (p = 0.59). CONCLUSION: The higher estimated SNR yielded by the monopolar DWI sequence did not translate into better HCC detection compared with the bipolar DWI sequence. ADC has a limited role for HCC characterization in patients with liver disease.


Assuntos
Algoritmos , Carcinoma Hepatocelular/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Cirrose Hepática/patologia , Neoplasias Hepáticas/patologia , Adulto , Carcinoma Hepatocelular/etiologia , Doença Crônica , Diagnóstico Diferencial , Feminino , Humanos , Cirrose Hepática/complicações , Neoplasias Hepáticas/etiologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade