Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Air Waste Manag Assoc ; 60(3): 346-55, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20397564

RESUMO

The U.S. Environmental Protection Agency is promoting the development and application of sampling methods for the semicontinuous determination of fine particulate matter (PM2.5, particles with an aerodynamic diameter <2.5 microm) mass and chemical composition. Data obtained with these methods will significantly improve the understanding of the primary sources, chemical conversion processes, and meteorological atmospheric processes that lead to observed PM2.5 concentrations and will aid in the understanding of the etiology of PM2.5-related health effects. During January and February 2007, several semicontinuous particulate matter (PM) monitoring systems were compared at the Utah State Lindon Air Quality Sampling site. Semicontinuous monitors included instruments to measure total PM2.5 mass (filter dynamic measurement system [FDMS] tapered element oscillating microbalance [TEOM], GRIMM), nonvolatile PM2.5 mass (TEOM), sulfate and nitrate (two PM2.5 and one PM10 [PM with an aerodynamic diameter <10 microm] ion-chromatographic-based samplers), and black carbon (aethalometer). PM10 semicontinuous mass measurements were made with GRIMM and TEOM instruments. These measurements were all made on a 1-hr average basis. Source apportionment analysis indicated that sources impacting the site were mainly urban sources and included mobile sources (gasoline and diesel) and residential burning of wood, with some elevated concentrations because of the effect of winter inversions. The FDMS TEOM and GRIMM instruments were in good agreement, but TEOM monitor measurements were low because of the presence of significant semi-volatile material. Semi-volatile mass was present dominantly in the PM2.5 mass.


Assuntos
Aerossóis/análise , Monitoramento Ambiental/instrumentação , Material Particulado/análise , Aerossóis/química , Modelos Químicos , Material Particulado/química , Utah
2.
J Air Waste Manag Assoc ; 59(8): 1007-17, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19728495

RESUMO

Semi-volatile organic carbonaceous material (SVOC) in fine particles is not reliably measured with conventional semicontinuous carbon monitors because semi-volatile carbonaceous material is lost from the collection media during sample collection. Two modifications of a Sunset Laboratory carbon aerosol monitor allowing for the determination of semi-volatile fine particulate organic material are described. Collocated conventional and modified instruments were operated simultaneously using a common inlet. Comparisons were made with integrated PC-BOSS data for quartz filter retained nonvolatile organic carbon (NVOC) and elemental carbon (EC), SVOC, and total carbon (TC = SVOC + NVOC + EC) and good agreement was observed between TC concentrations during studies conducted in Rubidoux, CA. Precision of the comparison was sigma = +/-1.5 microg-C/m3 (+/-8%). On the basis of experiments performed with the modified Sunset monitor, a dual-oven Sunset monitor was developed and extensively tested in Lindon, UT; Riverside, CA; and in environmental exposure chambers. The precision for the measurement of TC with the dual-oven instrument was sigma = +/-1.4 microg-C/m3 (+/-13%).


Assuntos
Aerossóis/análise , Poluentes Atmosféricos/análise , Carbono/análise , Monitoramento Ambiental/métodos , Material Particulado/análise , Monitoramento Ambiental/instrumentação , Tamanho da Partícula , Utah , Volatilização
3.
J Air Waste Manag Assoc ; 58(1): 65-71, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18236795

RESUMO

The Particle Concentrator-Brigham Young University Organic Sampling System (PC-BOSS) has been previously verified as being capable of measuring total fine particulate matter (PM2.5), including semi-volatile species. The present study was conducted to determine if the simple modification of a commercial speciation sampler with a charcoal denuder followed by a filter pack containing a quartz filter and a charcoal-impregnated glass (CIG) fiber filter would allow for the measurement of total PM2.5, including semi-volatile organic material. Data were collected using an R&P (Rupprecht and Pastasnik Co., Inc.) Partisol Model 2300 speciation sampler; an R&P Partisol speciation sampler modified with a BOSS denuder, followed by a filter pack with a quartz and a CIG filter; a Met One spiral aerosol speciation sampler (SASS); and the PC-BOSS from November 2001 to March 2002 at a U.S. Environmental Protection Agency (EPA) Science to Achieve Results (STAR) sampling site in Lindon, UT. Total PM2.5 mass, ammonium nitrate (both nonvolatile and semi-volatile), ammonium sulfate, organic carbon (both non-volatile and semi-volatile), and elemental carbon were determined on a 24-hr basis. Results obtained with the individual samplers were compared to determine the capability of the modified R&P speciation sampler for measuring total PM2.5, including semi-volatile components. Data obtained with the modified speciation sampler agreed with the PC-BOSS results. Data obtained with the two unmodified speciation samplers were low by an average of 26% because of the loss of semi-volatile organic material from the quartz filter during sample collection.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental/instrumentação , Monitoramento Ambiental/métodos , Compostos Orgânicos/análise , Material Particulado/análise , Poluentes Atmosféricos/química , Carbono/análise , Carvão Vegetal , Filtração/instrumentação , Filtração/métodos , Compostos Orgânicos/química , Material Particulado/química , Quartzo , Estações do Ano , Sulfatos/análise , Utah , Volatilização
4.
J Air Waste Manag Assoc ; 58(1): 72-7, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18236796

RESUMO

Semi-volatile organic material (SVOM) in fine particles is not reliably measured with conventional semicontinuous carbon monitors because SVOM is lost from the collection media during sample collection. We have modified a Sunset Laboratory Carbon Aerosol Monitor to allow for the determination of SVOM. In a conventional Sunset monitor, gas-phase organic compounds are removed in the sampled airstream by a diffusion denuder employing charcoal-impregnated cellulose filter (CIF) surfaces. Subsequently, particles are collected on a quartz filter and the instrument then determines both the organic carbon and elemental carbon fractions of the aerosol using a thermal/optical method. However, some of the SVOM is lost from the filter during collection, and therefore is not determined. Because the interfering gas-phase organic compounds are removed before aerosol collection, the SVOM can be determined by filtering the particles at the instrument inlet and then replacing the quartz filter in the monitor with a charcoal-impregnated glass fiber filter (CIG), which retains the SVOM lost from particles collected on the inlet filter. The resulting collected SVOM is then determined in the analysis step by measurement of the carbonaceous material thermally evolved from the CIG filter. This concept was tested during field studies in February 2003 in Lindon, UT, and in July 2003 in Rubidoux, CA. The results obtained were validated by comparison with Particle Concentrator-Brigham Young University Organic Sampling System (PC-BOSS) results. The sum of nonvolatile organic material determined with a conventional Sunset monitor and SVOM determined with the modified Sunset monitor agree with the PC-BOSS results. Linear regression analysis of total carbon concentrations determined by the PC-BOSS and the Sunset resulted in a zero-intercept slope of 0.99 +/- 0.02 (R2 = 0.92) and a precision of sigma = +/- 1.5 microg C/m3 (8%).


Assuntos
Aerossóis/análise , Monitoramento Ambiental/instrumentação , Monitoramento Ambiental/métodos , Compostos Orgânicos/análise , Material Particulado/análise , Poluentes Atmosféricos/análise , Carbono/análise , Compostos Orgânicos/química , Material Particulado/química , Volatilização
5.
J Air Waste Manag Assoc ; 56(4): 384-97, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16681204

RESUMO

Ammonium nitrate and semivolatile organic material (SVOM) are significant components of fine particles in urban atmospheres. These components, however, are not properly determined with methods such as the fine particulate matter (PM2.5) Federal Reference Method (FRM) or other single filter samplers because of significant losses of semivolatile material (SVM) from particles collected on the filter during sampling. The R&P tapered element oscillating microbalance (TEOM) monitor also does not measure SVM, because this method heats the sample to remove particle bound water, which also results in evaporation of SVM. Recent advances in monitoring techniques have resulted in samplers for both integrated and continuous measurement of total PM2.5, including the particle concentrator-Brigham Young University organic sampling system (PC-BOSS), the real-time total ambient mass sampler (RAMS), and the R&P filter dynamics measurement system (FDMS) TEOM monitor. Results obtained using these samplers have been compared with those obtained with either a PM2.5 FRM sampler or a TEOM monitor in studies conducted during the past five years. These studies have shown the following: (1) the PC-BOSS, RAMS, and FDMS TEOM are all comparable. Each instrument measures both the nonvolatile material and the SVM. (2) The SVM is not retained on the heated filter of a regular TEOM monitor and is not measured by this sampling technique. (3) Much of the SVM is also lost during sampling from single filter samplers such as the PM2.5 FRM sampler. (4) The amount of SVM lost from single filter samplers can vary from less than one-third of that lost from heated TEOM filters during cold winter conditions to essentially all during warm summer conditions. (5) SVOM can only be reliably collected using an appropriate denuder sampler. (6) A PM2.5 speciation sampler can be easily modified to a denuder sampler with filters that can be analyzed for semivolatile organic carbon (OC), nonvolatile OC, and elemental carbon using existing OC/elemental carbon analytical techniques. The research upon which these statements are based for various urban studies are summarized in this paper.


Assuntos
Poluentes Ocupacionais do Ar/análise , Poluição do Ar/análise , Monitoramento Ambiental/métodos , Poluentes Ocupacionais do Ar/química , Filtração , Padrões de Referência , Reprodutibilidade dos Testes , Estações do Ano , Estados Unidos , Volatilização
6.
J Air Waste Manag Assoc ; 55(12): 1839-46, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16408688

RESUMO

Fine particulate matter (PM2.5) mass was determined on a continuous basis at the Salt Lake City Environmental Protection Agency Environmental Monitoring for Public Awareness and Community Tracking monitoring site in Salt Lake City, UT, using three different monitoring techniques. Hourly averaged PM2.5 mass data were collected during two sampling periods (summer 2000 and winter 2002) using a real-time total ambient mass sampler (RAMS), sample equilibration system (SES)-tapered element oscillating microbalance (TEOM), and conventional TEOM monitor. This paper compares the results obtained from the various monitoring systems, which differ in their treatment of semivolatile material (SVM; particle-bound water, semivolatile ammonium nitrate, and semivolatile organic compounds). PM2.5 mass results obtained by the RAMS were consistently higher than those obtained by the SES-TEOM and conventional TEOM monitors because of the RAMS ability to measure semivolatile ammonium nitrate and semivolatile organic material but not particle-bound water. The SES-TEOM monitoring system was able to account for an average of 28% of the SVM, whereas the conventional TEOM monitor loses essentially all of the SVM from the single filter during sampling. Occasional mass readings by the various TEOM monitors that are higher than RAMS results may reflect particle-bound water, which, under some conditions, is measured by the TEOM but not the RAMS.


Assuntos
Poluentes Atmosféricos/análise , Poeira/análise , Monitoramento Ambiental/métodos , Cidades , Monitoramento Ambiental/instrumentação , Fatores de Tempo , Utah , Volatilização
7.
Environ Health Perspect ; 112(3): 339-45, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-14998750

RESUMO

Epidemiologic studies report associations between particulate air pollution and cardiopulmonary morbidity and mortality. Although the underlying pathophysiologic mechanisms remain unclear, it has been hypothesized that altered autonomic function and pulmonary/systemic inflammation may play a role. In this study we explored the effects of air pollution on autonomic function measured by changes in heart rate variability (HRV) and blood markers of inflammation in a panel of 88 elderly subjects from three communities along the Wasatch Front in Utah. Subjects participated in multiple sessions of 24-hr ambulatory electrocardiographic monitoring and blood tests. Regression analysis was used to evaluate associations between fine particulate matter [aerodynamic diameter less than or equal to 2.5 microm (PM2.5)] and HRV, C-reactive protein (CRP), blood cell counts, and whole blood viscosity. A 100- microg/m3 increase in PM2.5 was associated with approximately a 35 (SE = 8)-msec decline in standard deviation of all normal R-R intervals (SDNN, a measure of overall HRV); a 42 (SE = 11)-msec decline in square root of the mean of the squared differences between adjacent normal R-R intervals (r-MSSD, an estimate of short-term components of HRV); and a 0.81 (SE = 0.17)-mg/dL increase in CRP. The PM2.5-HRV associations were reasonably consistent and statistically robust, but the CRP association dropped to 0.19 (SE = 0.10) after excluding the most influential subject. PM2.5 was not significantly associated with white or red blood cell counts, platelets, or whole-blood viscosity. Most short-term variability in temporal deviations of HRV and CRP was not explained by PM2.5; however, the small statistically significant associations that were observed suggest that exposure to PM2.5 may be one of multiple factors that influence HRV and CRP.


Assuntos
Envelhecimento , Poluentes Atmosféricos/intoxicação , Exposição Ambiental , Frequência Cardíaca , Inflamação , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/análise , Contagem de Células Sanguíneas , Proteína C-Reativa/análise , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho da Partícula , Análise de Regressão
8.
J Air Waste Manag Assoc ; 52(5): 563-72, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-12022695

RESUMO

The real-time ambient mass sampler (RAMS) is a continuous monitor based on particle concentrator, denuder, drier, and tapered element oscillating microbalance (TEOM) monitor technology. It is designed to measure PM2.5 mass, including the semi-volatile species NH4NO3 and semi-volatile organic material, but not to measure PM2.5 water content. The performance of the RAMS in an urban environment with high humidity was evaluated during the July 1999 NARSTO-Northeast Oxidant and Particles Study (NEOPS) intensive study at the Baxter water treatment plant in Philadelphia, PA. The results obtained with the RAMS were compared to mass measurements made with a TEOM monitor and to constructed mass obtained with a Particle Concentrator-Brigham Young University Organic Sampling System (PC-BOSS) sampler designed to determine the chemical composition of fine particles, including the semi-volatile species. An average of 28% of the fine particulate material present during the study was semi-volatile organic material lost from a filter during particle collection, and 1% was NH4NO3 that was also lost from the particles during sampling. The remaining mass was dominantly nonvolatile (NH4)2SO4 (31%) and organic material (37%), with minor amounts of soot, crustal material, and nonvolatile NH4NO3. Comparison of the RAMS and PC-BOSS results indicated that the RAMS correctly monitored for fine particulate mass, including the semivolatile material. In contrast, the heated filter of the TEOM monitor did not measure the semi-volatile material. The comparison of the RAMS and PC-BOSS data had a precision of +/-4.1 microg/m3 (+/-9.6%). The precision of the RAMS data was limited by the uncertainty in the blank correction for the reversible adsorption of water by the charcoal-impregnated cellulose sorbent filter of the RAMS monitor. The precision of the measurement of fine particulate components by the PC-BOSS was +/-6-8%.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental/instrumentação , Cidades , Monitoramento Ambiental/métodos , Filtração , Tamanho da Partícula , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Volatilização
9.
J Air Waste Manag Assoc ; 49(9): 69-75, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29073859

RESUMO

Ambient particles contain substantial quantities of material that can be lost from the particles during sample collection on a filter. These include ammonium nitrate and semi-volatile organic compounds. As a result, the concentrations of these species are often significantly in error for results obtained with a filter pack sampler. The accurate measurement of these semi-volatile fine particulate species is essential for a complete understanding of the possible causes of health effects associated with exposure to fine particles. Past organic compound diffusion denuder samplers developed by the authors (e.g., the Brigham Young University Organic Sampling System [BOSS]) are not amenable to routine field use because of the need to independently determine the gas-phase semi-volatile organic material efficiency of the denuder for each sample. This problem has been eliminated using a combined virtual impactor, particle-concentrator inlet to provide a concentrated stream of 0.1-2.5-µm particles. This is followed by a BOSS diffusion denuder and filter packs to collect particles, including any semi-volatile species lost from the particles during sampling. The samp ler (Particle Concentrator-Brigham Young University Organic Sampling System [PC-BOSS]) contains a post-denuder multifilter pack unit to allow for the routine collection of several sequential samples. The PC-BOSS can be used for the determination of both fine particulate nitrate and semi-volatile organic material without significant "positive" or "negative" sampling artifacts. Validation of the sampler for the determination of PM2.5 sulfate and nitrate based on comparison of results obtained at Riverside, CA with collocated PC-BOSS, annular denuder, and Chem Spec samplers indicates the PC-BOSS gives accurate results for these species with a precision of ±5-8%. An average of 33% of the PM2.5 nitrate was lost from the particles during sampling for both denuder and single filter samplers.

10.
J Air Waste Manag Assoc ; 47(4): 455-467, 1997 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28065152

RESUMO

The precision and accuracy of the determination of particulate sulfate and fluoride, and gas phase S02 and HF are estimated from the results obtained from collocated replicate samples and from collocated comparison samples for highland low-volume filter pack and annular diffusion denuder samplers. The results of replicate analysis of collocated samples and replicate analyses of a given sample for the determination of spherical aluminosilicate fly ash particles have also been compared. Each of these species is being used in the chemical mass balance source apportionment of sulfur oxides in the Grand Canyon region as part of Project MOHAVE, and the precision and accuracy analyses given in this paper provide input to that analysis. The precision of the various measurements reported here is ±1.8 nmol/m3 and ±2.5 nmol/m3 for the determination of S02 and sulfate, respectively, with an annular denuder. The precision is ±0.5 nmol/m3 and ±2.0 nmol/m3 for the determination of the same species with a high-volume or low-volume filter pack. The precision for the determination of the sum of HF(g) and fine particulate fluoride is +0.3 nmol/m3. The precision for the determination of aluminosilicate fly ash particles is ±100 particles/m3. At high concentrations of the various species, reproducibility of the various measurements is ±10% to ±14% of the measured concentration. The concentrations of sulfate determined using filter pack samplers are frequently higher than those determined using diffusion denuder sampling systems. The magnitude of the difference (e.g., 2-10 nmol sulfate/m3) is small, but important relative to the precision of the data and the concentrations of particulate sulfate present (typically 5-20 nmol sulfate/m3). The concentrations of S02(g) determined using a high-volume cascade impactor filter pack sampler are correspondingly lower than those obtained with diffusion denuder samplers. The concentrations of SOx (SOz(g) plus particulate sulfate) determined using the two samplers during Project MOHAVE at the Spirit Mountain, NV, and Hopi Point, AZ, sampling sites were in agreement. However, for samples collected at Painted Desert, AZ, and Meadview, AZ, the concentrations of SOx and S02(g) determined with a high-volume cascade impactor filter pack sampler were frequently lower than those determined using a diffusion denuder sampling system. These two sites had very low ambient relative humidity, an average of 25%. Possible causes of observed differences in the S02(g) and sulfate results obtained from different types of samplers are given.

11.
J Air Waste Manag Assoc ; 47(3): 455-467, 1997 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29081279

RESUMO

The precision and accuracy of the determination of particu-late sulfate and fluoride, and gas phase SO2 and HF are estimated from the results obtained from collocated replicate samples and from collocated comparison samples for high-and low-volume filter pack and annular diffusion denuder samplers. The results of replicate analysis of collocated samples and replicate analyses of a given sample for the determination of spherical aluminosilicate fly ash particles have also been compared. Each of these species is being used in the chemical mass balance source apportionment of sulfur oxides in the Grand Canyon region as part of Project MOHAVE, and the precision and accuracy analyses given in this paper provide input to that analysis. The precision of the various measurements reported here is ±1.8 nmol/m3 and ±2.5 nmol/m3 for the determination of SO2 and sulfate, respectively, with an annular denuder. The precision is ±0.5 nmol/m3 and ±2.0 nmol/m3 for the determination of the same species with a high-volume or low-volume filter pack. The precision for the determination of the sum of HF(g) and fine particulate fluoride is ±0.3 nmol/m3. The precision for the determination of aluminosilicate fly ash particles is ±100 particles/m3. At high concentrations of the various species, reproducibility of the various measurements is ±10% to ±14% of the measured concentration. The concentrations of sulfate determined using filter pack samplers are frequently higher than those determined using diffusion denuder sampling systems. The magnitude of the difference (e.g., 2-10 nmol sulfate/m3) is small, but important relative to the precision of the data and the concentrations of particulate sul-fate present (typically 5-20 nmol sulfate/m3). The concentrations of SO2(g) determined using a high-volume cascade impactor filter pack sampler are correspondingly lower than those obtained with diffusion denuder samplers. The concentrations of SOx (SO2(g) plus particulate sulfate) determined using the two samplers during Project MOHAVE at the Spirit Mountain, NV, and Hopi Point, AZ, sampling sites were in agreement. However, for samples collected at Painted Desert, AZ, and Meadview, AZ, the concentrations of SOx and SO2(g) determined with a high-volume cascade impactor filter pack sampler were frequently lower than those determined using a diffusion denuder sampling system. These two sites had very low ambient relative humidity, an average of 25%. Possible causes of observed differences in the SO2(g) and sulfate results obtained from different types of samplers are given.

12.
J Air Waste Manag Assoc ; 47(3): 357-369, 1997 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29081293

RESUMO

The Brigham Young University (BYU) organic sampling system (BOSS) and the high flow rate multi-system BYU organic sampling system (BIG BOSS), which use multichannel diffusion denuder sampling techniques, were both used to collect samples of atmospheric fine particulate organic material. Both systems were used at the Meadview sampling site located at the western boundary of the Grand Canyon National Park in northwestern Arizona for the Project MOHAVE summer intensive sampling program in August 1992. The concentrations of total fine particulate carbonaceous material determined by temperature programmed volatilization for BOSS collocated replicate samples were in agreement with an uncertainty of ±14%. A comparable agreement was seen between the BOSS and BIG BOSS samples. Carbonaceous material collected by the second of two sequential quartz filters was shown to have originated from organic material lost from particles during sampling. About one-half of the fine particulate organic material was lost from particles during sample collection. These semi-volatile organic compounds lost from particles during sampling were characterized by GC/MS analysis. The concentrations of n-alkanes, n-fatty acids, n-fatty methyl esters, and phthalic acid as a function of fine particulate size were obtained for compounds both retained by and lost from particles during sampling. The possible sources of fine particulate semi-volatile organic material collected at Meadview, and the particle size distribution of fine particulate organic material, n-alkanes, n-fatty acids, and n-fatty esters are discussed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA