Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 158
Filtrar
1.
Opt Express ; 32(12): 21643-21648, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38859513

RESUMO

Optical modulators play an important role in communication systems, and silicon has been a focal point in this field thanks to its compatibility with CMOS fabrication. However, silicon's lack of inherent electro-optic behavior makes it suboptimal for modulation purposes. Conversely, potassium tantalate niobate (KTN) materials boast an improved electro-optic coefficient, presenting a path for improving modulation efficiency. However, limited research exists on KTN materials due to the difficulties associated with their fabrication. Here, a fabrication methodology is described for wafer-scale vertical integration of KTN material onto silicon-on-insulator (SOI) wafers. The resulting devices exhibit a propagation loss of 3.3 dBmm1 and a transition loss within the range of 0.46 to 0.76 dB, which are in agreement with simulations. This method tackles the fabrication challenges and showcases the potential of utilising KTN as the integration material on silicon platform for future optical modulators.

2.
Comput Med Imaging Graph ; 116: 102403, 2024 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-38878632

RESUMO

BACKGROUND AND OBJECTIVES: Bio-medical image segmentation models typically attempt to predict one segmentation that resembles a ground-truth structure as closely as possible. However, as medical images are not perfect representations of anatomy, obtaining this ground truth is not possible. A surrogate commonly used is to have multiple expert observers define the same structure for a dataset. When multiple observers define the same structure on the same image there can be significant differences depending on the structure, image quality/modality and the region being defined. It is often desirable to estimate this type of aleatoric uncertainty in a segmentation model to help understand the region in which the true structure is likely to be positioned. Furthermore, obtaining these datasets is resource intensive so training such models using limited data may be required. With a small dataset size, differing patient anatomy is likely not well represented causing epistemic uncertainty which should also be estimated so it can be determined for which cases the model is effective or not. METHODS: We use a 3D probabilistic U-Net to train a model from which several segmentations can be sampled to estimate the range of uncertainty seen between multiple observers. To ensure that regions where observers disagree most are emphasised in model training, we expand the Generalised Evidence Lower Bound (ELBO) with a Constrained Optimisation (GECO) loss function with an additional contour loss term to give attention to this region. Ensemble and Monte-Carlo dropout (MCDO) uncertainty quantification methods are used during inference to estimate model confidence on an unseen case. We apply our methodology to two radiotherapy clinical trial datasets, a gastric cancer trial (TOPGEAR, TROG 08.08) and a post-prostatectomy prostate cancer trial (RAVES, TROG 08.03). Each dataset contains only 10 cases each for model development to segment the clinical target volume (CTV) which was defined by multiple observers on each case. An additional 50 cases are available as a hold-out dataset for each trial which had only one observer define the CTV structure on each case. Up to 50 samples were generated using the probabilistic model for each case in the hold-out dataset. To assess performance, each manually defined structure was matched to the closest matching sampled segmentation based on commonly used metrics. RESULTS: The TOPGEAR CTV model achieved a Dice Similarity Coefficient (DSC) and Surface DSC (sDSC) of 0.7 and 0.43 respectively with the RAVES model achieving 0.75 and 0.71 respectively. Segmentation quality across cases in the hold-out datasets was variable however both the ensemble and MCDO uncertainty estimation approaches were able to accurately estimate model confidence with a p-value < 0.001 for both TOPGEAR and RAVES when comparing the DSC using the Pearson correlation coefficient. CONCLUSIONS: We demonstrated that training auto-segmentation models which can estimate aleatoric and epistemic uncertainty using limited datasets is possible. Having the model estimate prediction confidence is important to understand for which unseen cases a model is likely to be useful.

3.
Phys Eng Sci Med ; 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38809365

RESUMO

Stereotactic body radiation therapy (SBRT) has been increasingly used for the ablation of liver tumours. CyberKnife and proton beam therapy (PBT) are two advanced treatment technologies suitable to deliver SBRT with high dose conformity and steep dose gradients. However, there is very limited data comparing the dosimetric characteristics of CyberKnife to PBT for liver SBRT. PBT and CyberKnife plans were retrospectively generated using 4DCT datasets of ten patients who were previously treated for hepatocellular carcinoma (HCC, N = 5) and liver metastasis (N = 5). Dose volume histogram data was assessed and compared against selected criteria; given a dose prescription of 54 Gy in 3 fractions for liver metastases and 45 Gy in 3 fractions for HCC, with previously published consensus-based normal tissue dose constraints. Comparison of evaluation parameters showed a statistically significant difference for target volume coverage and liver, lungs and spinal cord (p < 0.05) dose, while chest wall and skin did not indicate a significant difference between the two modalities. A number of optimal normal tissue constraints was violated by both the CyberKnife and proton plans for the same patients due to proximity of tumour to chest wall. PBT resulted in greater organ sparing, the extent of which was mainly dependent on tumour location. Tumours located on the liver periphery experienced the largest increase in organ sparing. Organ sparing for CyberKnife was comparable with PBT for small target volumes.

4.
Phys Imaging Radiat Oncol ; 30: 100568, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38585372

RESUMO

Background and purpose: The [18]F-fluoroethyl-l-tyrosine (FET) PET in Glioblastoma (FIG) study is an Australian prospective, multi-centre trial evaluating FET PET for newly diagnosed glioblastoma management. The Radiation Oncology credentialing program aimed to assess the feasibility in Radiation Oncologist (RO) derivation of standard-of-care target volumes (TVMR) and hybrid target volumes (TVMR+FET) incorporating pre-defined FET PET biological tumour volumes (BTVs). Materials and methods: Central review and analysis of TVMR and TVMR+FET was undertaken across three benchmarking cases. BTVs were pre-defined by a sole nuclear medicine expert. Intraclass correlation coefficient (ICC) confidence intervals (CIs) evaluated volume agreement. RO contour spatial and boundary agreement were evaluated (Dice similarity coefficient [DSC], Jaccard index [JAC], overlap volume [OV], Hausdorff distance [HD] and mean absolute surface distance [MASD]). Dose plan generation (one case per site) was assessed. Results: Data from 19 ROs across 10 trial sites (54 initial submissions, 8 resubmissions requested, 4 conditional passes) was assessed with an initial pass rate of 77.8 %; all resubmissions passed. TVMR+FET were significantly larger than TVMR (p < 0.001) for all cases. RO gross tumour volume (GTV) agreement was moderate-to-excellent for GTVMR (ICC = 0.910; 95 % CI, 0.708-0.997) and good-to-excellent for GTVMR+FET (ICC = 0.965; 95 % CI, 0.871-0.999). GTVMR+FET showed greater spatial overlap and boundary agreement compared to GTVMR. For the clinical target volume (CTV), CTVMR+FET showed lower average boundary agreement versus CTVMR (MASD: 1.73 mm vs. 1.61 mm, p = 0.042). All sites passed the planning exercise. Conclusions: The credentialing program demonstrated feasibility in successful credentialing of 19 ROs across 10 sites, increasing national expertise in TVMR+FET delineation.

5.
ACS Appl Energy Mater ; 7(6): 2299-2308, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38550300

RESUMO

Two-dimensional (2D) transition-metal dichalcogenides have shown great potential for energy storage applications owing to their interlayer spacing, large surface area-to-volume ratio, superior electrical properties, and chemical compatibility. Further, increasing the surface area of such materials can lead to enhanced electrical, chemical, and optical response for energy storage and generation applications. Vertical silicon nanowires (SiNWs), also known as black-Si, are an ideal substrate for 2D material growth to produce high surface-area heterostructures, owing to their ultrahigh aspect ratio. Achieving this using an industrially scalable method paves the way for next-generation energy storage devices, enabling them to enter commercialization. This work demonstrates large surface area, commercially scalable, hybrid MoS2/SiNW heterostructures, as confirmed by Raman spectroscopy, with high tunability of the MoS2 layers down to the monolayer scale and conformal MoS2 growth, parallel to the silicon nanowires, as verified by transmission electron microscopy (TEM). This has been achieved using a two-step atomic layer deposition (ALD) process, allowing MoS2 to be grown directly onto the silicon nanowires without any damage to the substrate. The ALD cycle number accurately defines the layer number from monolayer to bulk. Introducing an ALD alumina (Al2O3) interface at the MoS2/SiNW boundary results in enhanced MoS2 quality and uniformity, demonstrated by an order of magnitude reduction in the B/A exciton photoluminescence (PL) intensity ratio to 0.3 and a reduction of the corresponding layer number. This high-quality layered growth on alumina can be utilized in applications such as for interfacial layers in high-capacity batteries or for photocathodes for water splitting. The alumina-free 100 ALD cycle heterostructures demonstrated no diminishing quality effects, lending themselves well to applications that require direct electrical contact with silicon and benefit from more layers, such as electrodes for high-capacity ion batteries.

6.
Phys Imaging Radiat Oncol ; 29: 100536, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38303922

RESUMO

Background and purpose: Glioblastoma is one of the most common and aggressive primary brain tumours in adults. Though radiation therapy (RT) techniques have progressed significantly in recent decades, patient survival has seen little improvement. However, an area of promise is the use of fluorine-18-fluoroethyltyrosine positron-emission-tomography (18F-FET PET) imaging to assist in RT target delineation. This retrospective study aims to assess the impact of 18F-FET PET scan timing on the resultant RT target volumes and subsequent RT plans in post-operative glioblastoma patients. Materials and Methods: The imaging and RT treatment data of eight patients diagnosed with glioblastoma and treated at a single institution were analysed. Before starting RT, each patient had two 18F-FET-PET scans acquired within seven days of each other. The information from these 18F-FET-PET scans aided in the creation of two novel target volume sets. The new volumes and plans were compared with each other and the originals. Results: The median clinical target volume (CTV) 1 was statistically smaller than CTV 2. The median Dice score for the CTV1/CTV2 was 0.98 and, of the voxels that differ (median 6.5 cc), 99.7% were covered with a 5 mm expansion. Overall organs at risk (OAR) and target dosimetry were similar in the PTV1 and PTV2 plans. Conclusion: Provided the 18F-FET PET scan is acquired within two weeks of the RT planning and a comprehensive approach is taken to CTV delineation, the timing of scan acquisition has minimal impact on the resulting RT plan.

7.
Phys Eng Sci Med ; 47(2): 491-501, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38315414

RESUMO

Paediatric imaging protocols should be carefully optimised to maintain the desired image quality while minimising the delivered patient dose. A paediatric chest phantom was designed, constructed and evaluated to optimise chest CT examinations for infants. The phantom was designed to enable dosimetry and image quality measurements within the anthropomorphic structure. It was constructed using tissue equivalent materials to mimic thoracic structures of infants, aged 0-6 months. The phantom materials were validated across a range of diagnostic tube voltages with resulting CT numbers found equivalent to paediatric tissues observed via a survey of clinical paediatric chest studies. The phantom has been successfully used to measure radiation dose and evaluate various image quality parameters for paediatric specific protocols.


Assuntos
Imagens de Fantasmas , Tórax , Tomografia Computadorizada por Raios X , Humanos , Lactente , Tórax/diagnóstico por imagem , Doses de Radiação , Recém-Nascido , Radiografia Torácica
8.
Med Phys ; 51(5): 3766-3781, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38224317

RESUMO

BACKGROUND: Escalation of prescribed dose in prostate cancer (PCa) radiotherapy enables improvement in tumor control at the expense of increased toxicity. Opportunities for reduction of treatment toxicity may emerge if more efficient dose escalation can be achieved by redistributing the prescribed dose distribution according to the known heterogeneous, spatially-varying characteristics of the disease. PURPOSE: To examine the potential benefits, limitations and characteristics of heterogeneous boost dose redistribution in PCa radiotherapy based on patient-specific and population-based spatial maps of tumor biological features. METHOD: High-resolution prostate histology images, from a cohort of 63 patients, annotated with tumor location and grade, provided patient-specific "maps" and a population-based "atlas" of cell density and tumor probability. Dose prescriptions were derived for each patient based on a heterogeneous redistribution of the boost dose to the intraprostatic lesions, with the prescription maximizing patient tumor control probability (TCP). The impact on TCP was assessed under scenarios where the distribution of population-based biological data was ignored, partially included, or fully included in prescription generation. Heterogeneous dose prescriptions were generated for three combinations of maps and atlas, and for conventional fractionation (CF), extreme hypo-fractionation (EH), moderate hypo-fractionation (MH), and whole Pelvic RT + SBRT Boost (WPRT + SBRT). The predicted efficacy of the heterogeneous prescriptions was compared with equivalent homogeneous dose prescriptions. RESULTS: TCPs for heterogeneous dose prescriptions were generally higher than those for homogeneous dose prescriptions. TCP escalation by heterogeneous dose prescription was the largest for CF. When only using population-based atlas data, the generated heterogeneous dose prescriptions of 55 to 58 patients (out of 63) had a higher TCP than for the corresponding homogeneous dose prescriptions. The TCPs of the heterogeneous dose prescriptions generated with the population-based atlas and tumor probability maps did not differ significantly from those using patient-specific biological information. The generated heterogeneous dose prescriptions achieved significantly higher TCP than homogeneous dose prescriptions in the posterior section of the prostate. CONCLUSION: Heterogeneous dose prescriptions generated via biologically-optimized dose redistribution can produce higher TCP than the homogeneous dose prescriptions for the majority of the patients in the studied cohort. For scenarios where patient-specific biological information was unavailable or partially available, the generated heterogeneous dose prescriptions can still achieve TCP improvement relative to homogeneous dose prescriptions.


Assuntos
Neoplasias da Próstata , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos
9.
Phys Med Biol ; 69(5)2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38262060

RESUMO

Objective. To develop a physical grid collimator compatible with the X-RAD preclinical radiotherapy system and create a corresponding Monte Carlo (MC) model.Approach. This work presents a methodology for the fabrication of a grid collimator designed for utilisation on the X-RAD preclinical radiotherapy system. Additionally, a MC simulation of the grid is developed, which is compatible with the X-RAD treatment planning system. The grid was manufactured by casting a low melting point alloy, cerrobend, into a silicone mould. The silicone was moulded around a 3D-printed replica of the grid, enabling the production of diverging holes with precise radii and spacing. A MC simulation was conducted on an equivalent 3D grid model and validated using 11 layers of GAFChromic EBT-3 film interspersed in a 3D-printed water-equivalent phantom. A 3D dose distribution was constructed from the film layers, enabling a direct comparison with the MC Simulation.Main results. The film and the MC dose distribution demonstrated a gamma passing rate of 99% for a 1%, 0.5 mm criteria with a 10% threshold applied. The peak-to-valley dose ratio and output factor at the surface were determined to be 20.4 and 0.79, respectively.Significance. The pairing of the grid collimator with a MC simulation can significantly enhance the practicality of grid therapy on the X-RAD. This combination enables further exploration of the biological implications of grid therapy, supported by a knowledge of the complex dose distributions. Moreover, this methodology can be adapted for use in other systems and scenarios.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Silicones , Simulação por Computador , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Imagens de Fantasmas , Método de Monte Carlo
10.
Phys Med Biol ; 69(3)2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38198726

RESUMO

Objective. Clinical implementation of synthetic CT (sCT) from cone-beam CT (CBCT) for adaptive radiotherapy necessitates a high degree of anatomical integrity, Hounsfield unit (HU) accuracy, and image quality. To achieve these goals, a vision-transformer and anatomically sensitive loss functions are described. Better quantification of image quality is achieved using the alignment-invariant Fréchet inception distance (FID), and uncertainty estimation for sCT risk prediction is implemented in a scalable plug-and-play manner.Approach. Baseline U-Net, generative adversarial network (GAN), and CycleGAN models were trained to identify shortcomings in each approach. The proposed CycleGAN-Best model was empirically optimized based on a large ablation study and evaluated using classical image quality metrics, FID, gamma index, and a segmentation analysis. Two uncertainty estimation methods, Monte-Carlo Dropout (MCD) and test-time augmentation (TTA), were introduced to model epistemic and aleatoric uncertainty.Main results. FID was correlated to blind observer image quality scores with a Correlation Coefficient of -0.83, validating the metric as an accurate quantifier of perceived image quality. The FID and mean absolute error (MAE) of CycleGAN-Best was 42.11 ± 5.99 and 25.00 ± 1.97 HU, compared to 63.42 ± 15.45 and 31.80 HU for CycleGAN-Baseline, and 144.32 ± 20.91 and 68.00 ± 5.06 HU for the CBCT, respectively. Gamma 1%/1 mm pass rates were 98.66 ± 0.54% for CycleGAN-Best, compared to 86.72 ± 2.55% for the CBCT. TTA and MCD-based uncertainty maps were well spatially correlated with poor synthesis outputs.Significance. Anatomical accuracy was achieved by suppressing CycleGAN-related artefacts. FID better discriminated image quality, where alignment-based metrics such as MAE erroneously suggest poorer outputs perform better. Uncertainty estimation for sCT was shown to correlate with poor outputs and has clinical relevancy toward model risk assessment and quality assurance. The proposed model and accompanying evaluation and risk assessment tools are necessary additions to achieve clinically robust sCT generation models.


Assuntos
Tomografia Computadorizada de Feixe Cônico Espiral , Incerteza , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
11.
Phys Eng Sci Med ; 47(2): 455-463, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38285271

RESUMO

Single plan techniques for multiple brain targets (MBT) stereotactic radiosurgery (SRS) are now routine. Patient specific quality assurance (QA) for MBT poses challenges due to the limited capabilities of existing QA tools which necessitates several plan redeliveries. This study sought to develop an SRS QA phantom that enables flexible MBT patient specific QA in a single delivery, along with complex SRS commissioning. PLA marble and PLA StoneFil materials were selected based on the literature and previous research conducted in our department. The HU numbers were investigated to determine the appropriate percentage infill for skull and soft-tissue equivalence. A Prusa MK3S printer in conjunction with the above-mentioned filaments were used to print the SRS QA phantom. Quality control (QC) was performed on the printed skull, film inserts and plugs for point dose measurements. EBT3 film and point dose measurements were performed using a CC04 ionisation chamber. QC demonstrated that the SRS QA phantom transverse, coronal and sagittal film planes were orthogonal within 0.5°. HU numbers for the skull, film inserts and plugs were 858 ± 20 and 35 ± 12 respectively. Point and EBT3 film dose measurements were within 2.5% and 3%/2 mm 95% gamma pass rate, respectively except one Gross Tumour Volume (GTV) that had a slightly lower gamma pass rate. Dose distributions to five GTVs were measured with EBT3 film in a single plan delivery on CyberKnife. In conclusion, an SRS QA phantom was designed, and 3D printed and its use for performing complex MBT patient specific QA in a single delivery was demonstrated.


Assuntos
Encéfalo , Imagens de Fantasmas , Impressão Tridimensional , Garantia da Qualidade dos Cuidados de Saúde , Radiocirurgia , Radiocirurgia/instrumentação , Humanos , Encéfalo/cirurgia , Encéfalo/diagnóstico por imagem , Garantia da Qualidade dos Cuidados de Saúde/normas , Controle de Qualidade , Planejamento da Radioterapia Assistida por Computador , Dosagem Radioterapêutica
12.
J Med Imaging Radiat Oncol ; 68(1): 57-66, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37898984

RESUMO

INTRODUCTION: Malignant pleural mesothelioma is difficult to prognosticate. F18-Fluorodeoxyglucose positron emission tomography (FDG PET) shows promise for response assessment but is confounded by talc pleurodesis. F18-Fluorothymidine (FLT) PET is an alternative tracer specific for proliferation. We compared the prognostic value of FDG and FLT PET and determined the influence of talc pleurodesis on these parameters. METHODS: Overall, 29 prospectively recruited patients had FLT PET, FDG PET and CT-scans performed prior to and post one chemotherapy cycle; 10 had prior talc pleurodesis. Patients were followed for overall survival. CT response was assessed using mRECIST. Radiomic features were extracted using the MiM software platform. Changes in maximum SUV (SUVmax), mean SUV (SUVmean), FDG total lesion glycolysis (TLG), FLT total lesion proliferation (TLP) and metabolic tumour volume (MTV) after one chemotherapy cycle. RESULTS: Cox univariate analysis demonstrated FDG PET radiomics were confounded by talc pleurodesis, and that percentage change in FLT MTV was predictive of overall survival. Cox multivariate analysis showed a 10% increase in FLT tumour volume corresponded with 9.5% worsened odds for overall survival (P = 0.028, HR = 1.095, 95% CI [1.010, 1.187]). No other variables were significant on multivariate analysis. CONCLUSION: This is the first prospective study showing the statistical significance of FLT PET tumour volumes for measuring mesothelioma treatment response. FLT may be better than FDG for monitoring mesothelioma treatment response, which could help optimise mesothelioma treatment regimes.


Assuntos
Mesotelioma Maligno , Mesotelioma , Humanos , Mesotelioma Maligno/diagnóstico por imagem , Prognóstico , Estudos Prospectivos , Fluordesoxiglucose F18 , Talco , Compostos Radiofarmacêuticos , Tomografia por Emissão de Pósitrons/métodos , Mesotelioma/diagnóstico por imagem , Mesotelioma/tratamento farmacológico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos
13.
Cryst Growth Des ; 23(11): 7821-7828, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37937193

RESUMO

Current heterogeneous Si photonics usually bond III-V wafers/dies on a silicon-on-insulator (SOI) substrate in a back-end process, whereas monolithic integration by direct epitaxy could benefit from a front-end process where III-V materials are grown prior to the fabrication of passive optical circuits. Here we demonstrate a front-end-of-line (FEOL) processing and epitaxy approach on Si photonics 220 nm (001) SOI wafers to enable positioning dislocation-free GaAs layers in lithographically defined cavities right on top of the buried oxide layer. Thanks to the defect confinement in lateral growth, threading dislocations generated from the III-V/Si interface are effectively trapped within ∼250 nm of the Si surface. This demonstrates the potential of in-plane co-integration of III-Vs with Si on mainstream 220 nm SOI platform without relying on thick, defective buffer layers. The challenges associated with planar defects and coalescence into larger membranes for the integration of on-chip optical devices are also discussed.

14.
Cancers (Basel) ; 15(19)2023 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-37835581

RESUMO

BACKGROUND: Focal boost radiotherapy was developed to deliver elevated doses to functional sub-volumes within a target. Such a technique was hypothesized to improve treatment outcomes without increasing toxicity in prostate cancer treatment. PURPOSE: To summarize and evaluate the efficacy and variability of focal boost radiotherapy by reviewing focal boost planning studies and clinical trials that have been published in the last ten years. METHODS: Published reports of focal boost radiotherapy, that specifically incorporate dose escalation to intra-prostatic lesions (IPLs), were reviewed and summarized. Correlations between acute/late ≥G2 genitourinary (GU) or gastrointestinal (GI) toxicity and clinical factors were determined by a meta-analysis. RESULTS: By reviewing and summarizing 34 planning studies and 35 trials, a significant dose escalation to the GTV and thus higher tumor control of focal boost radiotherapy were reported consistently by all reviewed studies. Reviewed trials reported a not significant difference in toxicity between focal boost and conventional radiotherapy. Acute ≥G2 GU and late ≥G2 GI toxicities were reported the most and least prevalent, respectively, and a negative correlation was found between the rate of toxicity and proportion of low-risk or intermediate-risk patients in the cohort. CONCLUSION: Focal boost prostate cancer radiotherapy has the potential to be a new standard of care.

15.
Sci Rep ; 13(1): 17673, 2023 10 17.
Artigo em Inglês | MEDLINE | ID: mdl-37848692

RESUMO

[68Ga]Ga-PSMA-11 PET has become the standard imaging modality for biochemically recurrent (BCR) prostate cancer (PCa). However, its prognostic value in assessing response at this stage remains uncertain. The study aimed to assess the prognostic significance of radiographic patient-level patterns of progression derived from lesion-level biomarker quantitation in metastatic disease sites. A total of 138 BCR PCa patients with both baseline and follow-up [68Ga]Ga-PSMA-11 PET scans were included in this analysis. Tumour response was quantified at the lesion level using commonly used quantitative parameters (SUVmean, SUVmax, SUVpeak, volume), and patients were classified as systemic, mixed, or no-progression based on these response classifications. A total of 328 matched lesions between baseline and follow-up scans were analysed. The results showed that systemic progressors had a significantly higher risk of death than patients with no progression with SUVmean demonstrating the highest prognostic value (HR = 5.70, 95% CI = 2.63-12.37, p < 0.001, C-Index = 0.69). Moreover, progressive disease as measured by SUVmean using the radiographic PSMA PET Progression Criteria (rPPP) was found to be significantly prognostic for patient overall survival (HR = 3.67, 95% CI = 1.82-7.39, p < 0.001, C-Index = 0.65). This work provides important evidence supporting the prognostic utility of PSMA response quantitation in the BCR setting.


Assuntos
Radioisótopos de Gálio , Neoplasias da Próstata , Masculino , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Biomarcadores , Ácido Edético , Antígeno Prostático Específico
16.
Br J Radiol ; 96(1152): 20221178, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37751168

RESUMO

OBJECTIVE: This study aimed to quantify both the intra- and intertracer repeatability of lesion-level radiomics features in [68Ga]Ga-prostate-specific membrane antigen (PSMA)-11 and [18F]F-PSMA-1007 positron emission tomography (PET) scans. METHODS: Eighteen patients with metastatic prostate cancer (mPCa) were prospectively recruited for the study and randomised to one of three test-retest groups: (i) intratracer [68Ga]Ga-PSMA-11 PET, (ii) intratracer [18F]F-PSMA-1007 PET or (iii) intertracer between [68Ga]Ga-PSMA-11 and [18F]F-PSMA-1007 PET. Four conventional PET metrics (standardised uptake value (SUV)max, SUVmean, SUVtotal and volume) and 107 radiomics features were extracted from 75 lesions and assessed using the repeatability coefficient (RC) and the ICC. Radiomic feature repeatability was also quantified after the application of 16 filters to the PET image. RESULTS: Test-retest scans were taken a median of 5 days apart (range: 2-7 days). SUVmean demonstrated the lowest RC limits of the conventional features, with RCs of 7.9%, 14.2% and 24.7% for the [68Ga]Ga-PSMA-11 PET, [18F]F-PSMA-1007 PET, and intertracer groups, respectively. 69%, 66% and 9% of all radiomics features had good or excellent ICC values (ICC ≥ 0.75) for the same groups. Feature repeatability therefore diminished considerably for the intertracer group relative to intratracer groups. CONCLUSION: In this study, robust biomarkers for each tracer group that can be used in subsequent clinical studies were identified. Overall, the repeatability of conventional and radiomic features were found to be substantially lower for the intertracer group relative to both intratracer groups, suggesting that assessing patient response quantitatively should be done using the same radiotracer where possible. ADVANCES IN KNOWLEDGE: Intertracer biomarker repeatability limits are significantly larger than intratracer limits.


Assuntos
Radioisótopos de Gálio , Neoplasias da Próstata , Masculino , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Prospectivos , Radiômica , Tomografia por Emissão de Pósitrons , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia
17.
Phys Eng Sci Med ; 46(4): 1477-1487, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37552365

RESUMO

Single plan multiple brain targets (MBT) stereotactic radiosurgery dose difference between Monte Carlo (MC) and Ray Tracing (RT) algorithms has not been studied. A retrospective study and dose measurements were performed to access factors influencing dose differences. Fifty-three RT treatment plans with a total of 209 brain metastases were extracted from Precision Treatment Planning System (TPS). These plans were generated using fixed cones and were delivered using the CyberKnife M6 system. The same treatment plans were recalculated using MC algorithm and keeping the beam parameters unchanged. MC calculated plan parameters were extracted and dose differences were normalised to MC calculated dose. Correlations were investigated. RT and MC calculated off-centre-ratio (OCR) and tissue-phantom-ratio (TPRs) were exported from the TPS and compared with measured. Plans with 5 gross tumour volumes (GTVs) were created on a phantom and dose measured using a CC04 ionisation chamber and microdiamond detector for comparison with calculated doses. Calculated and measured TPR agreed within ± 1% beyond depth of maximum dose. The OCR showed differences up to 4.3% in the penumbra and out-of-field (OOF) regions. Largest RT and MC calculated GTV mean dose difference was - 5.7%. An increase in the number of GTVs and reduction in the geometric separation of metastases were associated with increased differences between RT and MC calculated doses. In conclusion, calculated dose disagreement in MBT depends on the number of GTVs per plan, number of GTVs within a certain separation distance and plan complexity. MC dose calculation is recommended for complex CyberKnife SRS of MBT.


Assuntos
Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/cirurgia , Dosagem Radioterapêutica , Estudos Retrospectivos , Planejamento da Radioterapia Assistida por Computador , Algoritmos , Encéfalo/diagnóstico por imagem , Encéfalo/cirurgia , Encéfalo/patologia
18.
Eur J Nucl Med Mol Imaging ; 50(13): 4077-4086, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37550494

RESUMO

PURPOSE: This study aimed to (i) validate the Response Evaluation Criteria in PSMA (RECIP 1.0) criteria in a cohort of biochemically recurrent (BCR) prostate cancer (PCa) patients and (ii) determine if this classification could be performed fully automatically using a trained artificial intelligence (AI) model. METHODS: One hundred ninety-nine patients were imaged with [68Ga]Ga-PSMA-11 PET/CT once at the time of biochemical recurrence and then a second time a median of 6.0 months later to assess disease progression. Standard-of-care treatments were administered to patients in the interim. Whole-body tumour volume was quantified semi-automatically (TTVman) in all patients and using a novel AI method (TTVAI) in a subset (n = 74, the remainder were used in the training process of the model). Patients were classified as having progressive disease (RECIP-PD), or non-progressive disease (non RECIP-PD). Association of RECIP classifications with patient overall survival (OS) was assessed using the Kaplan-Meier method with the log rank test and univariate Cox regression analysis with derivation of hazard ratios (HRs). Concordance of manual and AI response classifications was evaluated using the Cohen's kappa statistic. RESULTS: Twenty-six patients (26/199 = 13.1%) presented with RECIP-PD according to semi-automated delineations, which was associated with a significantly lower survival probability (log rank p < 0.005) and higher risk of death (HR = 3.78 (1.96-7.28), p < 0.005). Twelve patients (12/74 = 16.2%) presented with RECIP-PD according to AI-based segmentations, which was also associated with a significantly lower survival (log rank p = 0.013) and higher risk of death (HR = 3.75 (1.23-11.47), p = 0.02). Overall, semi-automated and AI-based RECIP classifications were in fair agreement (Cohen's k = 0.31). CONCLUSION: RECIP 1.0 was demonstrated to be prognostic in a BCR PCa population and is robust to two different segmentation methods, including a novel AI-based method. RECIP 1.0 can be used to assess disease progression in PCa patients with less advanced disease. This study was registered with the Australian New Zealand Clinical Trials Registry (ACTRN12615000608561) on 11 June 2015.


Assuntos
Radioisótopos de Gálio , Neoplasias da Próstata , Masculino , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Prognóstico , Inteligência Artificial , Oligopeptídeos , Ácido Edético , Austrália , Neoplasias da Próstata/patologia , Progressão da Doença
19.
BMJ Open ; 13(8): e071327, 2023 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-37541751

RESUMO

INTRODUCTION: Glioblastoma is the most common aggressive primary central nervous system cancer in adults characterised by uniformly poor survival. Despite maximal safe resection and postoperative radiotherapy with concurrent and adjuvant temozolomide-based chemotherapy, tumours inevitably recur. Imaging with O-(2-[18F]-fluoroethyl)-L-tyrosine (FET) positron emission tomography (PET) has the potential to impact adjuvant radiotherapy (RT) planning, distinguish between treatment-induced pseudoprogression versus tumour progression as well as prognostication. METHODS AND ANALYSIS: The FET-PET in Glioblastoma (FIG) study is a prospective, multicentre, non-randomised, phase II study across 10 Australian sites and will enrol up to 210 adults aged ≥18 years with newly diagnosed glioblastoma. FET-PET will be performed at up to three time points: (1) following initial surgery and prior to commencement of chemoradiation (FET-PET1); (2) 4 weeks following concurrent chemoradiation (FET-PET2); and (3) within 14 days of suspected clinical and/or radiological progression on MRI (performed at the time of clinical suspicion of tumour recurrence) (FET-PET3). The co-primary outcomes are: (1) to investigate how FET-PET versus standard MRI impacts RT volume delineation and (2) to determine the accuracy and management impact of FET-PET in distinguishing pseudoprogression from true tumour progression. The secondary outcomes are: (1) to investigate the relationships between FET-PET parameters (including dynamic uptake, tumour to background ratio, metabolic tumour volume) and progression-free survival and overall survival; (2) to assess the change in blood and tissue biomarkers determined by serum assay when comparing FET-PET data acquired prior to chemoradiation with other prognostic markers, looking at the relationships of FET-PET versus MRI-determined site/s of progressive disease post chemotherapy treatment with MRI and FET-PET imaging; and (3) to estimate the health economic impact of incorporating FET-PET into glioblastoma management and in the assessment of post-treatment pseudoprogression or recurrence/true progression. Exploratory outcomes include the correlation of multimodal imaging, blood and tumour biomarker analyses with patterns of failure and survival. ETHICS AND DISSEMINATION: The study protocol V.2.0 dated 20 November 2020 has been approved by a lead Human Research Ethics Committee (Austin Health, Victoria). Other clinical sites will provide oversight through local governance processes, including obtaining informed consent from suitable participants. The study will be conducted in accordance with the principles of the Declaration of Helsinki and Good Clinical Practice. Results of the FIG study (TROG 18.06) will be disseminated via relevant scientific and consumer forums and peer-reviewed publications. TRIAL REGISTRATION NUMBER: ANZCTR ACTRN12619001735145.


Assuntos
Neoplasias Encefálicas , Ficus , Glioblastoma , Adulto , Humanos , Adolescente , Glioblastoma/diagnóstico por imagem , Glioblastoma/terapia , Glioblastoma/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tirosina , Estudos Prospectivos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/terapia , Neoplasias Encefálicas/patologia , Recidiva Local de Neoplasia/diagnóstico por imagem , Austrália , Tomografia por Emissão de Pósitrons , Imageamento por Ressonância Magnética , Ensaios Clínicos Fase II como Assunto , Estudos Multicêntricos como Assunto
20.
Eur J Nucl Med Mol Imaging ; 50(13): 3970-3981, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37563351

RESUMO

PURPOSE: The O-(2-[18F]-fluoroethyl)-L-tyrosine (FET) PET in Glioblastoma (FIG) trial is an Australian prospective, multi-centre study evaluating FET PET for glioblastoma patient management. FET PET imaging timepoints are pre-chemoradiotherapy (FET1), 1-month post-chemoradiotherapy (FET2), and at suspected progression (FET3). Before participant recruitment, site nuclear medicine physicians (NMPs) underwent credentialing of FET PET delineation and image interpretation. METHODS: Sites were required to complete contouring and dynamic analysis by ≥ 2 NMPs on benchmarking cases (n = 6) assessing biological tumour volume (BTV) delineation (3 × FET1) and image interpretation (3 × FET3). Data was reviewed by experts and violations noted. BTV definition includes tumour-to-background ratio (TBR) threshold of 1.6 with crescent-shaped background contour in the contralateral normal brain. Recurrence/pseudoprogression interpretation (FET3) required assessment of maximum TBR (TBRmax), dynamic analysis (time activity curve [TAC] type, time to peak), and qualitative assessment. Intraclass correlation coefficient (ICC) assessed volume agreement, coefficient of variation (CoV) compared maximum/mean TBR (TBRmax/TBRmean) across cases, and pairwise analysis assessed spatial (Dice similarity coefficient [DSC]) and boundary agreement (Hausdorff distance [HD], mean absolute surface distance [MASD]). RESULTS: Data was accrued from 21 NMPs (10 centres, n ≥ 2 each) and 20 underwent review. The initial pass rate was 93/119 (78.2%) and 27/30 requested resubmissions were completed. Violations were found in 25/72 (34.7%; 13/12 minor/major) of FET1 and 22/74 (29.7%; 14/8 minor/major) of FET3 reports. The primary reasons for resubmission were as follows: BTV over-contour (15/30, 50.0%), background placement (8/30, 26.7%), TAC classification (9/30, 30.0%), and image interpretation (7/30, 23.3%). CoV median and range for BTV, TBRmax, and TBRmean were 21.53% (12.00-30.10%), 5.89% (5.01-6.68%), and 5.01% (3.37-6.34%), respectively. BTV agreement was moderate to excellent (ICC = 0.82; 95% CI, 0.63-0.97) with good spatial (DSC = 0.84 ± 0.09) and boundary (HD = 15.78 ± 8.30 mm; MASD = 1.47 ± 1.36 mm) agreement. CONCLUSION: The FIG study credentialing program has increased expertise across study sites. TBRmax and TBRmean were robust, with considerable variability in BTV delineation and image interpretation observed.


Assuntos
Neoplasias Encefálicas , Ficus , Glioblastoma , Medicina Nuclear , Humanos , Glioblastoma/diagnóstico por imagem , Glioblastoma/patologia , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Estudos Prospectivos , Austrália , Tomografia por Emissão de Pósitrons/métodos , Tirosina , Imageamento por Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA