RESUMO
AIMS: Short-term ambulatory electrocardiogram (ECG) monitoring is often used to assess premature atrial complex (PAC) and premature ventricular complex (PVC) frequency, but the diagnostic reliability is unknown. The objective of this study was to study the day-to-day variability of PAC and PVC frequency. METHODS AND RESULTS: We used 14-day full-disclosure mobile cardiac telemetry recordings without atrial fibrillation in 8245 US patients aged 17-103 years to calculate the diagnostic reliability of shorter ambulatory ECG recordings compared with 14-day averages. Over 14 days, 1853 patients had ≥500 PACs/day, 410 patients had ≥5000 PACs/day, and 197 patients had ≥10 000 PACs/day; 1640 patients had ≥500 PVCs/day, 354 patients had ≥5000 PVCs/day, and 175 patients had ≥10 000 PVCs/day. After 3 days, the estimated daily PAC frequency differed by ≥50% from the 14-day mean in 25% of patients; for PVCs, the corresponding duration was 7 days. Ten days of monitoring were needed to estimate PAC and PVC frequency within ±20% of the overall 14-day frequency in 80% of patients. For daily PAC and PVC frequencies ≥10 000, single-day estimation had a specificity of 99.3% [95% confidence interval (CI) 99.1-99.5] at a sensitivity of 76.6 (95% CI 70.1-80.4%) for PACs and a 99.6% (95% CI 99.4-99.7%) specificity at 79.4 (95% CI 72.7-85.2) sensitivity for PVCs. After 7 days, the sensitivity increased to 88.8% (95% CI 83.6-92.9) for PACs and 86.9% (95% CI 80.9-91.5%) for PVCs. CONCLUSION: While there is substantial daily variability across most PAC and PVC levels, findings of ≥10 000 PACs or PVCs are highly specific and do not need to be confirmed with longer recordings.
Assuntos
Complexos Atriais Prematuros , Eletrocardiografia Ambulatorial , Complexos Ventriculares Prematuros , Humanos , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/fisiopatologia , Pessoa de Meia-Idade , Idoso , Reprodutibilidade dos Testes , Feminino , Complexos Atriais Prematuros/diagnóstico , Complexos Atriais Prematuros/fisiopatologia , Eletrocardiografia Ambulatorial/métodos , Adulto , Masculino , Adolescente , Idoso de 80 Anos ou mais , Adulto Jovem , Fatores de Tempo , Telemetria , Valor Preditivo dos Testes , Frequência CardíacaRESUMO
BACKGROUND: Elevated heart rate (HR) predicts cardiovascular disease and mortality, but there are no established normal limits for ambulatory HR. We used data from the Swedish CArdioPulmonary Imaging Study to determine reference ranges for ambulatory HR in a middle-aged population. We also studied clinical correlates of ambulatory HR. METHODS: A 24-hour ECG was registered in 5809 atrial fibrillation-free individuals, aged 50-65 years. A healthy subset (n=3942) was used to establish reference values (excluding persons with beta-blockers, cardiovascular disease, hypertension, heart failure, anaemia, diabetes, sleep apnoea or chronic obstructive pulmonary disease).Minimum HR was defined as the lowest 1-minute HR. Reference ranges are reported as means±SDs and 2.5th-97.5th percentiles. Clinical correlates of ambulatory HR were analysed with multivariable linear regression. RESULTS: The average mean and minimum HRs were 73±9 and 48±7 beats per minute (bpm) in men and 76±8 and 51±7 bpm in women; the reference range for mean ambulatory HR was 57-90 bpm in men and 61-92 bpm in women. Average daytime and night-time HRs are also reported. Clinical correlates, including age, sex, height, body mass index, physical activity, smoking, alcohol intake, diabetes, hypertension, haemoglobin level, use of beta-blockers, estimated glomerular filtration rate, per cent of predicted forced expiratory volume in 1 s and coronary artery calcium score, explained <15% of the interindividual differences in HR. CONCLUSION: Ambulatory HR varies widely in healthy middle-aged individuals, a finding with relevance for the management of patients with a perception of tachycardia. Differences in ambulatory HR between individuals are largely independent of common clinical correlates.
Assuntos
Eletrocardiografia Ambulatorial , Frequência Cardíaca , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Frequência Cardíaca/fisiologia , Valores de Referência , Idoso , Eletrocardiografia Ambulatorial/métodos , Suécia/epidemiologia , Fatores EtáriosRESUMO
Background: Ventricular tachycardia (VT) occurs intermittently, unpredictably, and has potentially lethal consequences. Objective: Our aim was to derive a risk prediction model for VT episodes ≥10 beats detected on 30-day mobile cardiac telemetry based on the first 24 hours of the recording. Methods: We included patients who were monitored for 2 to 30 days in the United States using full-disclosure mobile cardiac telemetry, without any VT episode ≥10 beats on the first full recording day. An elastic net prediction model was derived for the outcome of VT ≥10 beats on monitoring days 2 to 30. Potential predictors included age, sex, and electrocardiographic data from the first 24 hours: heart rate; premature atrial and ventricular complexes occurring as singlets, couplets, triplets, and runs; and the fastest rate for each event. The population was randomly split into training (70%) and testing (30%) samples. Results: In a population of 19,781 patients (mean age 65.3 ± 17.1 years, 43.5% men), with a median recording time of 18.6 ± 9.6 days, 1510 patients had at least 1 VT ≥10 beats. The prediction model had good discrimination in the testing sample (area under the receiver-operating characteristic curve 0.7584, 95% confidence interval 0.7340-0.7829). A model excluding age and sex had an equally good discrimination (area under the receiver-operating characteristic curve 0.7579, 95% confidence interval 0.7332-0.7825). In the top quintile of the score, more than 1 in 5 patients had a VT ≥10 beats, while the bottom quintile had a 98.2% negative predictive value. Conclusion: Our model can predict risk of VT ≥10 beats in the near term using variables derived from 24-hour electrocardiography, and could be used to triage patients to extended monitoring.
RESUMO
BACKGROUND: Lung cancer is one of the most common cancers in the world. Early detection and correct staging are fundamental for treatment and prognosis. Positron emission tomography with computed tomography (PET/CT) is recommended clinically. Silicon (Si) photomultiplier (PM)-based PET technology and new reconstruction algorithms are hoped to increase the detection of small lesions and enable earlier detection of pathologies including metastatic spread. The aim of this study was to compare the diagnostic performance of a SiPM-based PET/CT (including a new block-sequential regularization expectation maximization (BSREM) reconstruction algorithm) with a conventional PM-based PET/CT including a conventional ordered subset expectation maximization (OSEM) reconstruction algorithm. The focus was patients admitted for 18F-fluorodeoxyglucose (FDG) PET/CT for initial diagnosis and staging of suspected lung cancer. Patients were scanned on both a SiPM-based PET/CT (Discovery MI; GE Healthcare, Milwaukee, MI, USA) and a PM-based PET/CT (Discovery 690; GE Healthcare, Milwaukee, MI, USA). Standardized uptake values (SUV) and image interpretation were compared between the two systems. Image interpretations were further compared with histopathology when available. RESULTS: Seventeen patients referred for suspected lung cancer were included in our single injection, dual imaging study. No statically significant differences in SUVmax of suspected malignant primary tumours were found between the two PET/CT systems. SUVmax in suspected malignant intrathoracic lymph nodes was 10% higher on the SiPM-based system (p = 0.026). Good consistency (14/17 cases) between the PET/CT systems were found when comparing simplified TNM staging. The available histology results did not find any obvious differences between the systems. CONCLUSION: In a clinical setting, the new SiPM-based PET/CT system with a new BSREM reconstruction algorithm provided a higher SUVmax for suspected lymph node metastases compared to the PM-based system. However, no improvement in lung cancer detection was seen.