1.
AJNR Am J Neuroradiol ; 42(7): 1216-1222, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33985944

RESUMO

BACKGROUND AND PURPOSE: When managing meningiomas, intraoperative tumor consistency and histologic subtype are indispensable factors influencing operative strategy. The purposes of this study were the following: 1) to investigate the correlation between stiffness assessed with MR elastography and perfusion metrics from perfusion CT, 2) to evaluate whether MR elastography and perfusion CT could predict intraoperative tumor consistency, and 3) to explore the predictive value of stiffness and perfusion metrics in distinguishing among histologic subtypes of meningioma. MATERIALS AND METHODS: Mean tumor stiffness and relative perfusion metrics (blood flow, blood volume, and MTT) were calculated (relative to normal brain tissue) for 14 patients with meningiomas who underwent MR elastography and perfusion CT before surgery (cohort 1). Intraoperative tumor consistency was graded by a neurosurgeon in 18 patients (cohort 2, comprising the 14 patients from cohort 1 plus 4 additional patients). The correlation between tumor stiffness and perfusion metrics was evaluated in cohort 1, as was the ability of perfusion metrics to predict intraoperative tumor consistency and discriminate histologic subtypes. Cohort 2 was analyzed for the ability of stiffness to determine intraoperative tumor consistency and histologic subtypes. RESULTS: The relative MTT was inversely correlated with stiffness (P = .006). Tumor stiffness was positively correlated with intraoperative tumor consistency (P = .01), while perfusion metrics were not. Relative MTT significantly discriminated transitional meningioma from meningothelial meningioma (P = .04), while stiffness did not significantly differentiate any histologic subtypes. CONCLUSIONS: In meningioma, tumor stiffness may be useful to predict intraoperative tumor consistency, while relative MTT may potentially correlate with tumor stiffness and differentiate transitional meningioma from meningothelial meningioma.


Assuntos
Encéfalo , Técnicas de Imagem por Elasticidade , Imageamento por Ressonância Magnética , Neoplasias Meníngeas , Meningioma , Idoso , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Feminino , Humanos , Masculino , Neoplasias Meníngeas/irrigação sanguínea , Neoplasias Meníngeas/diagnóstico por imagem , Meningioma/irrigação sanguínea , Meningioma/diagnóstico por imagem , Meningioma/patologia , Pessoa de Meia-Idade , Perfusão , Estudos Retrospectivos , Resistência ao Cisalhamento , Tomografia Computadorizada por Raios X , Rigidez Vascular
2.
NMR Biomed ; : e3996, 2018 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-30101999

RESUMO

Magnetic resonance elastography (MRE) is increasingly being applied to thin or small structures in which wave propagation is dominated by waveguide effects, which can substantially bias stiffness results with common processing approaches. The purpose of this work was to investigate the importance of such biases and artifacts on MRE inversion results in: (i) various idealized 2D and 3D geometries with one or more dimensions that are small relative to the shear wavelength; and (ii) a realistic cardiac geometry. Finite element models were created using simple 2D geometries as well as a simplified and a realistic 3D cardiac geometry, and simulated displacements acquired by MRE from harmonic excitations from 60 to 220 Hz across a range of frequencies. The displacement wave fields were inverted with direct inversion of the Helmholtz equation with and without the application of bandpass filtering and/or the curl operator to the displacement field. In all geometries considered, and at all frequencies considered, strong biases and artifacts were present in inversion results when the curl operator was not applied. Bandpass filtering without the curl was not sufficient to yield accurate recovery. In the 3D geometries, strong biases and artifacts were present in 2D inversions even when the curl was applied, while only 3D inversions with application of the curl yielded accurate recovery of the complex shear modulus. These results establish that taking the curl of the wave field and performing a full 3D inversion are both necessary steps for accurate estimation of the shear modulus both in simple thin-walled or small structures and in a realistic cardiac geometry when using simple inversions that neglect the hydrostatic pressure term. In practice, sufficient wave amplitude, signal-to-noise ratio, and resolution will be required to achieve accurate results.

3.
J Mech Behav Biomed Mater ; 84: 88-98, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29754046

RESUMO

Alterations in brain rheology are increasingly recognized as a diagnostic marker for various neurological conditions. Magnetic resonance elastography now allows us to assess brain rheology repeatably, reproducibly, and non-invasively in vivo. Recent elastography studies suggest that brain stiffness decreases one percent per year during normal aging, and is significantly reduced in Alzheimer's disease and multiple sclerosis. While existing studies successfully compare brain stiffnesses across different populations, they fail to provide insight into changes within the same brain. Here we characterize rheological alterations in one and the same brain under extreme metabolic changes: alive and dead. Strikingly, the storage and loss moduli of the cerebrum increased by 26% and 60% within only three minutes post mortem and continued to increase by 40% and 103% within 45 minutes. Immediate post mortem stiffening displayed pronounced regional variations; it was largest in the corpus callosum and smallest in the brainstem. We postulate that post mortem stiffening is a manifestation of alterations in polarization, oxidation, perfusion, and metabolism immediately after death. Our results suggest that the stiffness of our brain-unlike any other organ-is a dynamic property that is highly sensitive to the metabolic environment. Our findings emphasize the importance of characterizing brain tissue in vivo and question the relevance of ex vivo brain tissue testing as a whole. Knowing the true stiffness of the living brain has important consequences in diagnosing neurological conditions, planning neurosurgical procedures, and modeling the brain's response to high impact loading.


Assuntos
Encéfalo/citologia , Fenômenos Mecânicos , Animais , Autopsia , Fenômenos Biomecânicos , Encéfalo/metabolismo , Elasticidade , Feminino , Modelos Lineares , Teste de Materiais , Bainha de Mielina/metabolismo , Reologia , Suínos , Viscosidade
4.
AJNR Am J Neuroradiol ; 39(1): 31-36, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29074637

RESUMO

BACKGROUND AND PURPOSE: Our aim was to noninvasively evaluate gliomas with MR elastography to characterize the relationship of tumor stiffness with tumor grade and mutations in the isocitrate dehydrogenase 1 (IDH1) gene. MATERIALS AND METHODS: Tumor stiffness properties were prospectively quantified in 18 patients (mean age, 42 years; 6 women) with histologically proved gliomas using MR elastography from 2014 to 2016. Images were acquired on a 3T MR imaging unit with a vibration frequency of 60 Hz. Tumor stiffness was compared with unaffected contralateral white matter, across tumor grade, and by IDH1-mutation status. The performance of the use of tumor stiffness to predict tumor grade and IDH1 mutation was evaluated with the Wilcoxon rank sum, 1-way ANOVA, and Tukey-Kramer tests. RESULTS: Gliomas were softer than healthy brain parenchyma, 2.2 kPa compared with 3.3 kPa (P < .001), with grade IV tumors softer than grade II. Tumors with an IDH1 mutation were significantly stiffer than those with wild type IDH1, 2.5 kPa versus 1.6 kPa, respectively (P = .007). CONCLUSIONS: MR elastography demonstrated that not only were gliomas softer than normal brain but the degree of softening was directly correlated with tumor grade and IDH1-mutation status. Noninvasive determination of tumor grade and IDH1 mutation may result in improved stratification of patients for different treatment options and the evaluation of novel therapeutics. This work reports on the emerging field of "mechanogenomics": the identification of genetic features such as IDH1 mutation using intrinsic biomechanical information.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/genética , Glioma/diagnóstico por imagem , Glioma/genética , Isocitrato Desidrogenase/genética , Adulto , Idoso , Neoplasias Encefálicas/patologia , Técnicas de Imagem por Elasticidade , Feminino , Glioma/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Mutação , Gradação de Tumores
5.
AJNR Am J Neuroradiol ; 37(3): 462-7, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26542235

RESUMO

BACKGROUND AND PURPOSE: Normal pressure hydrocephalus is a reversible neurologic disorder characterized by a triad of cognitive impairment, gait abnormality, and urinary incontinence that is commonly treated with ventriculoperitoneal shunt placement. However, multiple overlapping symptoms often make it difficult to differentiate normal pressure hydrocephalus from other types of dementia, and improved diagnostic techniques would help patient management. MR elastography is a novel diagnostic tool that could potentially identify patients with normal pressure hydrocephalus. The purpose of this study was to assess brain stiffness changes in patients with normal pressure hydrocephalus compared with age- and sex-matched cognitively healthy individuals. MATERIALS AND METHODS: MR elastography was performed on 10 patients with normal pressure hydrocephalus and 21 age- and sex-matched volunteers with no known neurologic disorders. Image acquisition was conducted on a 3T MR imaging scanner. Shear waves with 60-Hz vibration frequency were transmitted into the brain by a pillowlike passive driver. A novel postprocessing technique resistant to noise and edge artifacts was implemented to determine regional brain stiffness. The Wilcoxon rank sum test and linear regression were used for statistical analysis. RESULTS: A significant increase in stiffness was observed in the cerebrum (P = .001), occipital lobe (P < .001), parietal lobe (P = .001), and the temporal lobe (P = .02) in the normal pressure hydrocephalus group compared with healthy controls. However, no significant difference was noted in other regions of the brain, including the frontal lobe (P = .07), deep gray and white matter (P = .43), or cerebellum (P = .20). CONCLUSIONS: This study demonstrates increased brain stiffness in patients with normal pressure hydrocephalus compared with age- and sex-matched healthy controls; these findings should motivate future studies investigating the use of MR elastography for this condition and the efficacy of shunt therapy.


Assuntos
Técnicas de Imagem por Elasticidade , Hidrocefalia de Pressão Normal/diagnóstico , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Encéfalo , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade
6.
Phys Med Biol ; 56(14): 4291-309, 2011 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-21701049

RESUMO

Magnetic resonance elastography (MRE) is a non-invasive phase-contrast-based method for quantifying the shear stiffness of biological tissues. Synchronous application of a shear wave source and motion encoding gradient waveforms within the MRE pulse sequence enable visualization of the propagating shear wave throughout the medium under investigation. Encoded shear wave-induced displacements are then processed to calculate the local shear stiffness of each voxel. An important consideration in local shear stiffness estimates is that the algorithms employed typically calculate shear stiffness using relatively high signal-to-noise ratio (SNR) MRE images and have difficulties at an extremely low SNR. A new method of estimating shear stiffness based on the principal spatial frequency of the shear wave displacement map is presented. Finite element simulations were performed to assess the relative insensitivity of this approach to decreases in SNR. Additionally, ex vivo experiments were conducted on normal rat lungs to assess the robustness of this approach in low SNR biological tissue. Simulation and experimental results indicate that calculation of shear stiffness by the principal frequency method is less sensitive to extremely low SNR than previously reported MRE inversion methods but at the expense of loss of spatial information within the region of interest from which the principal frequency estimate is derived.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Resistência ao Cisalhamento , Animais , Fenômenos Biomecânicos , Feminino , Análise de Elementos Finitos , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Ratos , Ratos Sprague-Dawley
7.
Aliment Pharmacol Ther ; 34(1): 83-91, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21535445

RESUMO

BACKGROUND: Liver stiffness assessed using transient elastography is described as a potential risk factor for hepatocellular carcinoma (HCC) in cirrhosis. However, the strict assessment of hepatic parenchymal areas uninvolved with HCC has not been investigated. AIM: To determine if liver stiffness of nonmalignant hepatic parenchyma using magnetic resonance elastography (MRE) is higher in patients with HCC compared with controls. METHODS: Cases were defined by compensated cirrhosis with a Child-Turcotte-Pugh score <7 and HCC by radiological criteria or histology. Control subjects with compensated cirrhosis were frequency matched with cases by gender and disease aetiology. Overt manifestations of portal hypertension and previous therapy for liver disease or HCC were exclusion criteria. Region of interest analyses were performed on hepatic parenchyma regions distant to HCC location among cases. RESULTS: Thirty patients with HCC and 60 matched controls comprised the study cohort. The mean age for cases was 64±10 years (range, 45-85) with 70% being men. Major disease aetiologies were chronic viral hepatitis (57%), non-alcoholic fatty liver disease (33%) and alcohol (10%). Twenty-eight (93%) patients had solitary HCC lesions with a mean size of 5.2 cm (range, 2-14 cm). However, patients with HCC had similar liver stiffness among uninvolved areas distant to HCC lesions, when compared with controls without HCC (mean, 6.1±2.0 vs. 6.3±2.5 kPa, P=0.7). CONCLUSION: In contrast to previous studies with transient elastography, we did not observe a systematic association between liver stiffness assessed using MRE and the presence of HCC in patients with compensated cirrhosis.


Assuntos
Carcinoma Hepatocelular/complicações , Técnicas de Imagem por Elasticidade , Cirrose Hepática/patologia , Neoplasias Hepáticas/complicações , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Humanos , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico , Neoplasias Hepáticas/diagnóstico , Masculino , Pessoa de Meia-Idade , Fatores de Risco
8.
IEEE Trans Med Imaging ; 28(10): 1526-33, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19783495

RESUMO

Magnetic resonance elastography (MRE) is an imaging modality capable of visualizing the elastic properties of an object using magnetic resonance imaging (MRI) measurements of transverse acoustic strain waves induced in the object by a harmonically oscillating mechanical vibration. Various algorithms have been designed to determine the mechanical properties of the object under the assumptions of linear elasticity, isotropic and local homogeneity. One of the challenging problems in MRE is to reduce the noise effects and to maintain contrast in the reconstructed shear modulus images. In this paper, we propose a new algorithm designed to reduce the degree of noise amplification in the reconstructed shear modulus images without the assumption of local homogeneity. Investigating the relation between the measured displacement data and the stress wave vector, the proposed algorithm uses an iterative reconstruction formula based on a decomposition of the stress wave vector. Numerical simulation experiments and real experiments with agarose gel phantoms and human liver data demonstrate that the proposed algorithm is more robust to noise compared to standard inversion algorithms and stably determines the shear modulus.


Assuntos
Algoritmos , Módulo de Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Processamento de Imagem Assistida por Computador/métodos , Simulação por Computador , Humanos , Fígado/anatomia & histologia , Imagens de Fantasmas
9.
Magn Reson Med ; 59(1): 14-8, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18058936

RESUMO

MR elastography (MRE) is a phase contrast-based technique for spatially mapping the mechanical properties of tissue-like materials. While hyperpolarized noble gases such as helium-3 ((3)He) have proven to be an ideal contrast mechanism for imaging of the lung using conventional MR techniques, their applicability for lung MRE is unknown, due to the fact that gases do not support shear. In this study, we report on the application of MRE to an ex vivo porcine lung specimen inflated with a hyperpolarized noble gas. Unlike proton MRE, shear wave propagation is encoded into the gas entrapped within the alveolar spaces rather than the parenchyma itself. These data provide first evidence of the technical feasibility of MRE of the lung using hyperpolarized noble gases.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Pulmão/fisiologia , Imageamento por Ressonância Magnética/métodos , Animais , Elasticidade , Hélio , Aumento da Imagem/métodos , Isótopos , Imageamento por Ressonância Magnética/instrumentação , Suínos
10.
Artigo em Inglês | MEDLINE | ID: mdl-18002530

RESUMO

MR Elastography is a new technique using conventional MRI system to assess the elastic properties of tissues. When using pneumatic driver, usually one driver was put at one place of tissue. But the shear wave generated by one pneumatic driver cannot illuminate the large area due to the attenuation. So we use two pneumatic drivers driven synchronously to generate interference shear wave in our experiments. The results from the phantom study show the interference wave pattern generated by the twin pneumatic drivers can compensate the attenuation of the shear wave when propagating in phantom. Also, a finite element modeling was used to simulate twin pneumatic driver datasets. It is hoped that by twin pneumatic drivers, we can illuminate the whole brain; the liver and large areas in-vivo. Further study will be conducted with the twin pneumatic drivers in ex-vivo and in-vivo studies.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Fenômenos Biomecânicos , Técnicas de Imagem por Elasticidade/instrumentação , Humanos , Imageamento por Ressonância Magnética/instrumentação , Viscosidade
11.
Magn Reson Med ; 56(5): 1060-6, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17036283

RESUMO

Magnetic resonance elastography (MRE) is a phase-contrast technique that can spatially map shear stiffness within tissue-like materials. To date, however, MRE of the lung has been too technically challenging-primarily because of signal-to-noise ratio (SNR) limitations and phase instability. We describe an approach in which shear wave propagation is not encoded into the phase of the MR signal of a material, but rather from the signal arising from a polarized noble gas encapsulated within. To determine the feasibility of the approach, three experiments were performed. First, to establish whether shear wave propagation within lung parenchyma can be visualized with phase-contrast MR techniques, MRE was performed on excised porcine lungs inflated with room air. Second, a phantom consisting of open-cell foam filled with thermally polarized (3)He gas was imaged with MRE to determine whether shear wave propagation can be encoded by the gas. Third, preliminary evidence of the feasibility of MRE in vivo was obtained by using a longitudinal driver on the chest of a normal volunteer to generate shear waves in the lung. The results suggest that MRE in combination with hyperpolarized noble gases is potentially useful for noninvasively assessing the regional elastic properties of lung parenchyma, and merits further investigation.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Pulmão/fisiologia , Imageamento por Ressonância Magnética/métodos , Trítio , Animais , Meios de Contraste , Elasticidade , Estudos de Viabilidade , Humanos , Aumento da Imagem/métodos , Técnicas In Vitro , Pulmão/anatomia & histologia , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Estresse Mecânico , Suínos
12.
Magn Reson Med ; 56(3): 593-600, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16902974

RESUMO

The goal of this current study was to determine whether an MRI-based elastography (MRE) method can visualize and assess propagating mechanical waves within fluid-filled vessels and to investigate the feasibility of measuring the elastic properties of vessel walls and quantitatively assessing stenotic lesions by using MRE. The ability to measure the Young's modulus-wall thickness product was tested using a thin-walled latex vessel model. Also tested in vessel models was the ability to quantitate the degree of stenosis by measuring transmitted and reflected mechanical waves. This method was then applied to ex vivo porcine models and in vivo human arteries to further test its feasibility. The results provide preliminary evidence that MRE can be used to quantitatively assess the stiffness of blood vessels, and provide a non-morphologic method to measure stenosis. With further development, it is possible that the method can be implemented in vivo.


Assuntos
Algoritmos , Artérias/anatomia & histologia , Artérias/fisiologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Cardiovasculares , Animais , Simulação por Computador , Elasticidade , Humanos , Técnicas In Vitro , Armazenamento e Recuperação da Informação/métodos , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resistência ao Cisalhamento , Estresse Mecânico , Suínos
13.
Magn Reson Med ; 55(5): 1175-9, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16528708

RESUMO

Magnetic resonance elastography (MRE) is capable of quantitatively depicting the mechanical properties of tissues in vivo. In contrast to mechanical excitation at the surface of the tissue, the method proposed in this study describes shear waves produced by an inserted needle. The results demonstrate that MRE performed with the needle driver provides shear stiffness estimates that correlate well with those obtained using mechanical testing. Comparisons between MRE acquisitions obtained with surface and needle drivers yielded similar results in general. However, the well-defined wave propagation pattern provided by the needle driver in a target region can reduce section orientation-related error in wavelength estimation that occurs with surface drivers in 2D MRE acquisitions. Preliminary testing of the device was performed on animals. This study demonstrates that the needle driver is an effective option that offers advantages over surface drivers for obtaining accurate stiffness estimates in targeted regions that are accessible by the needle.


Assuntos
Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/anatomia & histologia , Músculo Esquelético/fisiologia , Estimulação Física/instrumentação , Animais , Elasticidade , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/métodos , Masculino , Palpação , Estimulação Física/métodos , Coelhos , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estresse Mecânico
14.
Magn Reson Med ; 54(4): 893-900, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16155879

RESUMO

We present a novel extension of standard magnetic resonance elastography (MRE) measurement and analysis methods, which is applicable in cases where the medium is characterized by waveguides or fiber bundles (i.e., muscle) leading to constrained propagation of elastic waves. As a demonstration of this new method, MRI is utilized to identify the pathways of the individual fibers of a stalk of celery, and 3D MRE is then performed throughout the volume containing the celery fibers for a measurement of the displacements. A Helmholtz decomposition is performed permitting a separation of the displacements into longitudinal and transverse components, and an application of a hybrid Radon transform permits a spectral decomposition of wave propagation along the fibers. Dot product projections between these elastic displacements measured in the global coordinate system and three Frenet vectors representing the tangent and two corresponding orthogonal vectors along any particular fiber orientation yield the displacement contributions to wave propagation along the fiber as if it were a waveguide. A sliding window spatial Fourier transform is then performed along the length of each fiber to obtain dispersion images that portray space-wavenumber profiles. Therefore, this method can permit localized tracking and characterization of wave types, velocities, and coupling along arbitrarily oriented fibers.


Assuntos
Algoritmos , Apium/citologia , Apium/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Estimulação Física/métodos , Caules de Planta/citologia , Caules de Planta/fisiologia , Elasticidade , Estudos de Viabilidade , Imageamento Tridimensional/métodos , Armazenamento e Recuperação da Informação/métodos , Vibração
15.
Conf Proc IEEE Eng Med Biol Soc ; 2004: 1022-4, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-17271855

RESUMO

Magnetic resonance elastography (MRE) is a phase contrast-based method for observing shear wave propagation in a material to determine its stiffness. The objective of this study was to determine whether shear waves suitable for MRE could be induced using a moving acupuncture needle. Tissue-simulating bovine gel phantom and a 0.4 mm diameter acupuncture needle were used in the experiment. The results showed that observable shear waves could be induced in the gel phantom by cyclic needle motion. The observed wavelength varied with excitation frequency, as expected. Generating shear waves using moving needles may be a useful tool to study the basic mechanism of acupuncture with MRE. Further study will be conducted to observe the wave motion in inhomogeneous media and acupuncture-induced effects in in-vivo studies.

16.
Med Image Anal ; 7(4): 465-73, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14561551

RESUMO

Dynamic magnetic resonance elastography can visualize and measure propagating shear waves in tissue-like materials subjected to harmonic mechanical excitation. This allows the calculation of local values of material parameters such as shear modulus and attenuation. Various inversion algorithms to perform such calculations have been proposed, but they are sensitive to areas of low displacement amplitude (and hence low SNR) that result from interference patterns due to reflection and refraction. A spatio-temporal directional filter applied as a pre-processing step can separate interfering waves so they can be processed separately. Weighted combinations of inversions from such directionally separated data sets can significantly improve reconstructions of shear modulus and attenuation.


Assuntos
Mapeamento Encefálico/métodos , Neoplasias da Mama/diagnóstico , Imageamento por Ressonância Magnética/métodos , Algoritmos , Elasticidade , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas
17.
Med Image Anal ; 5(4): 237-54, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11731304

RESUMO

Magnetic resonance elastography (MRE) is a phase-contrast-based MRI imaging technique that can directly visualize and quantitatively measure propagating acoustic strain waves in tissue-like materials subjected to harmonic mechanical excitation. The data acquired allows the calculation of local quantitative values of shear modulus and the generation of images that depict tissue elasticity or stiffness. This is significant because palpation, a physical examination that assesses the stiffness of tissue, can be an effective method of detecting tumors, but is restricted to parts of the body that are accessible to the physician's hand. MRE shows promise as a potential technique for 'palpation by imaging', with possible applications in tumor detection (particularly in breast, liver, kidney and prostate), characterization of disease, and assessment of rehabilitation (particularly in muscle). We describe MRE in the context of other recent techniques for imaging elasticity, discuss the processing algorithms for elasticity reconstruction and the issues and assumptions they involve, and present recent ex vivo and in vivo results.


Assuntos
Imageamento por Ressonância Magnética/métodos , Acústica , Algoritmos , Animais , Fenômenos Biomecânicos , Encefalopatias/diagnóstico , Neoplasias da Mama/diagnóstico , Elasticidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Músculo Esquelético/fisiologia , Imagens de Fantasmas , Doenças Prostáticas/diagnóstico , Estresse Mecânico
18.
Magn Reson Med ; 45(2): 299-310, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11180438

RESUMO

Noninvasive quantitation of the mechanical properties of tissue could improve early detection of pathology. Previously a method for detecting displacement from propagating shear waves using a phase-contrast MRI technique was developed. In this work it is demonstrated how a collection of data representing the full vector displacement field could be used to potentially estimate the full complex stiffness tensor. An algebraic inversion approach useful for piece-wise homogeneous materials is described in detail for the general isotropic case, which is then specialized to incompressible materials as a model for tissue. Results of the inversion approach are presented for simulated and experimental phantom data that show the technique can be used to obtain shear wave-speed and attenuation in regions where there is sufficient signal-to-noise ratio in the displacement and its second spatial derivatives. The sensitivity to noise is higher in the attenuation estimates than the shear wave-speed estimates. Magn Reson Med 45:299-310, 2001.


Assuntos
Imageamento por Ressonância Magnética/métodos , Simulação por Computador , Elasticidade , Matemática , Modelos Teóricos , Imagens de Fantasmas
19.
AJR Am J Roentgenol ; 176(2): 513-8, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11159106

RESUMO

OBJECTIVE: The purpose of this study was to investigate the efficacy of a retrospective adaptive motion correction technique known as autocorrection for reducing motion-induced artifacts in high-resolution three-dimensional time-of-flight MR angiography of the circle of Willis. MATERIALS AND METHODS: Ten consecutive volunteers were imaged with an unenhanced gradient-recalled echo three-dimensional time-of-flight MR angiography sequence of the circle of Willis. Each volunteer was asked to rotate approximately 2 degrees after completion of one third and one half of the acquisition in the axial, sagittal, and oblique planes (45 degrees to the axial and sagittal planes). A single static data set was also acquired for each volunteer. Unprocessed and autocorrected maximum-intensity-projection images were reviewed as blinded image pairs by six radiologists and were compared on a five-point image quality scale. RESULTS: Mean improvement in image quality after autocorrection was 1.4 (p < 0.0001), 1.1 (p < 0.0001), and 0.2 (p = 0.003) observer points (maximum value, 2.0), respectively, for examinations corrupted by motion in the axial, oblique, and sagittal planes. All three axes had statistically significant improvement in image quality compared with the uncorrected images. Changes in image quality after the application of the autocorrection algorithm to static angiogram data were not statistically significant (mean change in score = -0.13 points; p = 0.29). CONCLUSION: Autocorrection can reduce artifacts in motion-corrupted MR angiography of the circle of Willis without distorting motion-free examinations.


Assuntos
Artefatos , Círculo Arterial do Cérebro/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Humanos , Radiografia
20.
J Magn Reson Imaging ; 13(2): 269-76, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11169834

RESUMO

While the contractile properties of skeletal muscle have been studied extensively, relatively little is known about the elastic properties of muscle in vivo. Magnetic resonance elastography (MRE) is a phase contrast-based method for observing shear waves propagating in a material to determine its stiffness. In this work, MRE is applied to skeletal muscle under load to quantify the change in stiffness with loading. A mathematical model of muscle is developed that predicts a linear relationship between shear stiffness and muscle load. The MRE technique was applied to bovine muscle specimens (N = 10) and human biceps brachii in vivo (N = 5). Muscle stiffness increased linearly for both passive tension (14.5 +/- 1.77 kPa/kg) and active tension, in which the increase in stiffness was dependent upon muscle size, as predicted by the model. A means of noninvasively assessing the viscoelastic pro-perties of skeletal muscle in vivo may provide a useful method for studying muscle biomechanics in health and disease.


Assuntos
Contração Isométrica/fisiologia , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/fisiologia , Suporte de Carga/fisiologia , Animais , Fenômenos Biomecânicos , Bovinos , Elasticidade , Humanos , Músculo Esquelético/patologia , Valores de Referência
SELEÇÃO DE REFERÊNCIAS