Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
2.
Clin Case Rep ; 11(5): e7349, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37215974

RESUMO

Key Clinical Message: Complex presentations of MCS patients may necessitate a multidisciplinary approach involving HF cardiologists, CT surgeons, advanced cardiac imagers, and interventional cardiologists in order to define the optimal management strategy. Abstract: Left ventricle assist devices (LVADs) provide life-sustaining treatment for patients with terminal heart failure, but their intricacy allows for complications. One complication is LVAD outflow graft obstruction due to the graft's intraluminal thrombus or extraluminal compression. It may be treated endovascularly with stenting. We report an endovascular stenting of an outflow tract in HVAD™ (HeartWare Inc.) due to a pseudoaneurysm causing compression and kinking stenosis.

3.
J Cardiothorac Surg ; 18(1): 102, 2023 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-37024888

RESUMO

BACKGROUND: Dislodgement of a coronary stent-balloon catheter during percutaneous coronary intervention (PCI) is rare but is a life-threatening complication. A 57- year-old male presented with a non-ST elevation myocardial infarction (NSTEMI). Coronary angiography revealed total thrombotic occlusion of the Right coronary artery (RCA). Following the balloon dilatation of the RCA and while trying to retrieve the balloon catheter, the balloon was dislodged from the catheter shaft and entrapped in the coronary vessel. Under cardiopulmonary bypass, with antegrade cardioplegic arrest, the balloon was extracted through a coronary arteriotomy. Right coronary revascularization was done with reversed saphenous vein graft (SVG). DISCUSSION: Given the variety of equipment that can be retained in the coronary artery and the multitude of mechanisms by which it may be entrapped, there are no straightforward techniques applicable to all situations. Specific guidelines or recommendations on properly managing these potentially life-threatening complications do not exist. However, the most crucial issue in the management of these cases is the hemodynamic status of the patient as well as the coronary flow in the vessel with entrapped device or stent. In our case, the RCA was retrogradely perfused from the left coronary artery, which provided time to transfer the patient to cardiovascular surgical backup.


Assuntos
Ponte de Artéria Coronária , Intervenção Coronária Percutânea , Masculino , Humanos , Pessoa de Meia-Idade , Resultado do Tratamento , Angiografia Coronária , Stents
4.
Heart Vessels ; 38(9): 1156-1163, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37004541

RESUMO

The outcome of the patients undergoing cardiac surgery with cardiopulmonary bypass (CPB) is also influenced by the renal and hepatic organ functions. Risk stratification, using scores such as EURO Score II or STS Short-Term Risk Calculator for patients undergoing cardiac surgery with cardiopulmonary bypass, ignores the quantitative renal and hepatic function; therefore, MELD-Score was applied in these cases. We retrospectively examined patient data using the MELD score as a predictor of mortality. To perform a univariate analysis of the data, patients were classified into three groups based on the MELD Score: MELD < 10 (Group 1), MELD 10 to 19 (Group 2), and MELD ≥ 20 (Group 3). A total of 11,477 participants were included in the study, though several patients with either missing MELD scores or lack of creatinine, bilirubin, or INR levels were dropped from the original cohort. Eventually, 10,882 patients were included in the analysis. The primary outcome was defined as postoperative, in-hospital mortality. Secondary outcomes such as postoperative bleeding, including the requirement for repeat thoracotomy, postoperative neurological complications, and assessment of catecholamines on weaning from cardiopulmonary bypass/ requirement of mechanical circulatory support were examined. A higher MELD score was associated with increased postoperative mortality. Patients with MELD > 20 experienced a 31.2% postoperative mortality, compared to Group 1 (4.6%) and Group 2 (17.5%). The highest rates of postoperative bleeding (13.8%) and, repeat thoracotomy (13.2%) & postoperative pneumonia (17.4%) were seen in Group 3 (threefold increase when compared to Group 1, renal failure requiring dialysis (N = 235, 2.7% in Group 1 v/s N = 78, 22.9% in Group 3) or requiring high dose catecholamines post-operatively or mechanical circulatory support (IABP/ECLS). Incidentally, an increased MELD Score was not associated with a significant increase in the postoperative incidence of stroke/TIA or the presence of sternal wound infections/complications. A higher mortality was observed in patients with reduced liver and renal function, with a significant increase in patients with a MELD score > 20. As the current risk stratification scores do not consider this, we recommend applying the MELD score before considering patients for cardiac surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Humanos , Estudos Retrospectivos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Fatores de Risco , Complicações Pós-Operatórias/etiologia , Fígado , Medição de Risco
5.
J Artif Organs ; 2023 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-37099051

RESUMO

Patient-tailored silicone plug for HeartMate 3™ left ventricular assist device explantation in two successive males proceeded successfully. Given medical therapeutic advancements, FDA-approved plug systems designed by LVAD manufacturers themselves will be necessary for the near future to provide a safe and simple device explantation alternative that fulfills all regulatory standards.

6.
Heart Surg Forum ; 26(2): E164-E169, 2023 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-36972597

RESUMO

BACKGROUND: The optimal management strategy for acute aortic type A dissection remains controversial. Whether a limited primary (index) repair would increase the need for late aortic reintervention is still an open debate. METHODS: A total of 393 consecutive adult patients with acute type A aortic dissection who underwent cardiac surgery were analyzed. Our research hypothesis was whether limited aortic index repair (i.e., isolated aorta ascending replacement without an open distal anastomosis with and without a concomitant aortic valve replacement, including hemiarch replacement procedure) is associated with a higher incidence of late aortic reoperation compared with extended repair (i.e., any other surgical procedure that goes beyond that limited approach). RESULTS: Type of the initial repair had no statically significant relationship with in-hospital mortality with a P-value of 0.12, however in multivariable analysis, cross-clamp time had a statistically significant relation with mortality (P = 0.4). From the patients who survived until discharge (N = 311), 40 patients needed a reoperation on the aorta; the mean interval until reoperation was 4.5 years. The relationship between the type of the initial repair and the need for reoperation didn't reach a statically significant value (P = 0.9). In-hospitable mortality after the second operation was 10% (N = 4). CONCLUSION: We reached two conclusions. 1) An extended prophylactic repair in the initial operation of an acute type A aortic dissection might not lead to a lower incidence of reoperations on the aorta and could increase in-hospital mortality by increasing cross-clamp time, and 2) Reoperation on the aorta could be done safely with acceptable mortality outcomes.


Assuntos
Aneurisma Aórtico , Dissecção Aórtica , Implante de Prótese Vascular , Adulto , Humanos , Aneurisma Aórtico/cirurgia , Reoperação , Estudos Retrospectivos , Implante de Prótese Vascular/métodos , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/cirurgia , Resultado do Tratamento , Doença Aguda
7.
Heart Surg Forum ; 26(2): E170-E173, 2023 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-36972599

RESUMO

Partial anomalous pulmonary venous drainage (PAPVD) is a relatively uncommon cardiac anomaly. The diagnosis might be challenging as are the presenting symptoms. Its clinical course mimics more familiar diseases, e.g., pulmonary artery embolism. We present a case of PAPVD, which had been misdiagnosed for more than two decades. After establishing the correct diagnosis, the patient got his congenital anomaly surgically corrected and showed excellent cardiac recovery in the six months follow up.


Assuntos
Cardiopatias Congênitas , Veias Pulmonares , Síndrome de Cimitarra , Humanos , Veias Pulmonares/cirurgia , Veias Pulmonares/anormalidades , Pulmão , Síndrome de Cimitarra/diagnóstico , Síndrome de Cimitarra/cirurgia , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/cirurgia , Drenagem
8.
Ann Noninvasive Electrocardiol ; 28(2): e13048, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36723848

RESUMO

BACKGROUND: Especially in the first 3 months after cardiac surgery, patients are at transient risk of sudden cardiac death (SCD). To close the gap between hospital discharge and the final implantable cardioverter-defibrillator (ICD) decision, guidelines recommend temporarily using a wearable cardioverter-defibrillator (WCD) to protect these patients from SCD. We investigated real-life data on the safety, effectiveness, and compliance of the WCD in this population. METHODS: Data for analysis were collected via the Zoll Patient Management Network (ZPM) from patients who underwent cardiac surgery and who were discharged with a WCD between 2018 and 2021 at the Cardiac Surgery Center of the University of Erlangen in Germany. RESULTS: The majority of the 55 patients were male (90.9%) and underwent a coronary artery bypass graft (80.0%). The number of patients with left ventricular ejection fraction (LVEF) >35% increased from 9.1% at the beginning of WCD use to 58.2% at the end of WCD use. Six ventricular tachycardia (VT) episodes occurred in four patients. The WCD appropriately defibrillated two patients with VT episodes. There were no inadequate shocks and no fatalities during the observation time. WCD wearing compliance was high, with a median wear time of 23.3 h/day. CONCLUSION: This retrospective analysis in a single cardiac surgery center confirms prior data on the safety and effectiveness of the WCD in patients in post-surgery care in a real-life setting. The WCD successfully protected patients from SCD during life-threatening VT episodes. WCD wearing compliance was high.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Desfibriladores Implantáveis , Taquicardia Ventricular , Dispositivos Eletrônicos Vestíveis , Humanos , Masculino , Feminino , Desfibriladores , Volume Sistólico , Estudos Retrospectivos , Função Ventricular Esquerda , Eletrocardiografia , Cardioversão Elétrica , Arritmias Cardíacas/etiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia
9.
J Card Surg ; 37(12): 5551-5555, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36345682

RESUMO

The ultimate goal in the treatment of end-stage heart failure is the recovery of cardiac function following mechanical assistance of the left ventricle. The HVAD™ pump (HeartWare Inc.) left ventricular assist device (LVAD) can be explanted without resternotomy. This article demonstrates that the use of a custom-made mechanical plug (manufactured by INNOVO Solutions GmbH), which can be inserted into the LVAD's sewing ring, is feasible. This mechanical plug explicitly designed for device explantation is a viable alternative to the current standard of care. This article adopts a less invasive technique to explant the pump. The following case illustrates this technique.


Assuntos
Cocaína , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Ventrículos do Coração/cirurgia , Titânio , Insuficiência Cardíaca/terapia , Remoção de Dispositivo/métodos
10.
J Card Surg ; 37(12): 5634-5638, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36403262

RESUMO

INTRODUCTION: The Frozen Elephant Trunk technique is a well-established treatment for aortic dissections (Stanford Type A) involving the aortic arch and descending aorta. The Thoraflex™ Hybrid prosthesis (Vascutek Ltd.), consisting of a proximal flexible conduit and a distal self-expanding covered stent, has consistently shown positive results in the treatment of this condition. CASE DESCRIPTION: The following is a description of such a staged reconstruction using the Thoraflex™ Hybrid Ante-Flo™ device, performed in a patient previously diagnosed with Loeys-Dietz Syndrome. After clamping the aorta proximally, an incision was taken at the distal end of the stent. Here, the distal end of the new prosthesis was inserted into the true lumen of the descending aorta and the stent was deployed. Following this, a bypass was established via the left atrium, and blood was returned to the lower body using the perfusion arm of the prosthesis with the proximal part of the descending aorta clamped. The collar of the prosthesis was sutured proximally to the aorta near the inlying previous stent. Air was removed via the perfusion arm of the prosthesis, which was then oversewn. DISCUSSION: To date, hybrid prostheses have only been used on the proximal aorta in patients with aortic aneurysms and aortic dissections (Stanford Type A). CONCLUSION: Using the described technique, it is possible to reconstruct the aortic anatomy using the available prostheses with accuracy and minimal complications.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Síndrome de Loeys-Dietz , Humanos , Prótese Vascular , Implante de Prótese Vascular/métodos , Síndrome de Loeys-Dietz/complicações , Síndrome de Loeys-Dietz/cirurgia , Dissecção Aórtica/cirurgia , Aorta Torácica/cirurgia , Stents , Aneurisma da Aorta Torácica/cirurgia , Resultado do Tratamento
11.
Thorac Cardiovasc Surg Rep ; 11(1): e50-e53, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36032935

RESUMO

An 83-year-old woman presented with a new onset of dyspnea and dysphonia. Physical examination revealed no abnormalities. Computerized tomography, bidimensional echocardiography, and cardiac magnetic resonance confirmed the presence of a cardiac mass in the left atrium. Surgical resection was uneventful and showed the origin of the mass in the ostium of the left inferior pulmonary vein. Histological evaluation revealed undifferentiated pleomorphic sarcoma with myxoid features. This case highlights the importance of considering cardiac neoplasms as a rare differential diagnosis, including rare and misleading clinical presentations.

12.
J Card Surg ; 37(10): 3440-3442, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35894824

RESUMO

The success of the left ventricular assist device (LVAD) as a treatment for terminal left-side heart failure is still restrained by some severe complications associated with mechanical circulatory support. Pump thrombus still affects many patients. It is associated with high morbidity and mortality. The therapeutic options include augmentation of anticoagulation and antiplatelet medication, intravenous or catheter-guided thrombolysis, and pump exchange. Heart transplantation would be a desirable option in this population, but unfortunately, it is only theoretical given the increasing number of LVAD implants and decreasing number of organ donors. A retrograde washout maneuver may be a treatment option in prepump thrombosis in selected patients. Therefore, the decision should be made on an individual basis after balancing the risks and benefits of different treatment approaches. In this context, we report a case of retrograde washout of prepump thrombus in a patient who has been on HeartWare™ support for more than 3 years, with a successful bailout strategy.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Trombose , Insuficiência Cardíaca/etiologia , Transplante de Coração/efeitos adversos , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Trombose/tratamento farmacológico , Trombose/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA