Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Hepatology ; 74(3): 1496-1508, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33724515

RESUMO

BACKGROUND AND AIMS: Liver fibrosis holds a relevant prognostic meaning in primary biliary cholangitis (PBC). Noninvasive fibrosis evaluation using vibration-controlled transient elastography (VCTE) is routinely performed. However, there is limited evidence on its accuracy at diagnosis in PBC. We aimed to estimate the diagnostic accuracy of VCTE in assessing advanced fibrosis (AF) at disease presentation in PBC. APPROACH AND RESULTS: We collected data from 167 consecutive treatment-naïve PBC patients who underwent liver biopsy (LB) at diagnosis at six Italian centers. VCTE examinations were completed within 12 weeks of LB. Biopsies were scored by two blinded expert pathologists, according to the Ludwig system. Diagnostic accuracy was estimated using the area under the receiver operating characteristic curves (AUROCs) for AF (Ludwig stage ≥III). Effects of biochemical and clinical parameters on liver stiffness measurement (LSM) were appraised. The derivation cohort consisted of 126 patients with valid LSM and LB; VCTE identified patients with AF with an AUROC of 0.89. LSM cutoffs ≤6.5 and >11.0 kPa enabled to exclude and confirm, respectively, AF (negative predictive value [NPV] = 0.94; positive predictive value [PPV] = 0.89; error rate = 5.6%). These values were externally validated in an independent cohort of 91 PBC patients (NPV = 0.93; PPV = 0.89; error rate = 8.6%). Multivariable analysis found that the only parameter affecting LSM was fibrosis stage. No association was found with BMI and liver biochemistry. CONCLUSIONS: In a multicenter study of treatment-naïve PBC patients, we identified two cutoffs (LSM ≤6.5 and >11.0 kPa) able to discriminate at diagnosis the absence or presence, respectively, of AF in PBC patients, with external validation. In patients with LSM between these two cutoffs, VCTE is not reliable and liver biopsy should be evaluated for accurate disease staging. BMI and liver biochemistry did not affect LSMs.


Assuntos
Cirrose Hepática Biliar/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Área Sob a Curva , Técnicas de Imagem por Elasticidade , Feminino , Humanos , Cirrose Hepática/patologia , Cirrose Hepática Biliar/patologia , Masculino , Pessoa de Meia-Idade , Curva ROC , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA