1.
Perioper Med (Lond) ; 11(1): 37, 2022 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-35941603

RESUMO

INTRODUCTION: Major surgery accounts for a substantial proportion of health service activity, due not only to the primary procedure, but the longer-term health implications of poor short-term outcome. Data from small studies or from outside the UK indicate that rates of complications and failure to rescue vary between hospitals, as does compliance with best practice processes. Within the UK, there is currently no system for monitoring postoperative complications (other than short-term mortality) in major non-cardiac surgery. Further, there is variation between national audit programmes, in the emphasis placed on quality assurance versus quality improvement, and therefore the principles of measurement and reporting which are used to design such programmes. METHODS AND ANALYSIS: The PQIP patient study is a multi-centre prospective cohort study which recruits patients undergoing major surgery. Patient provide informed consent and contribute baseline and outcome data from their perspective using a suite of patient-reported outcome tools. Research and clinical staff complete data on patient risk factors and outcomes in-hospital, including two measures of complications. Longer-term outcome data are collected through patient feedback and linkage to national administrative datasets (mortality and readmissions). As well as providing a uniquely granular dataset for research, PQIP provides feedback to participating sites on their compliance with evidence-based processes and their patients' outcomes, with the aim of supporting local quality improvement. ETHICS AND DISSEMINATION: Ethical approval has been granted by the Health Research Authority in the UK. Dissemination of interim findings (non-inferential) will form a part of the improvement methodology and will be provided to participating centres at regular intervals, including near-real time feedback of key process measures. Inferential analyses will be published in the peer-reviewed literature, supported by a comprehensive multi-modal communications strategy including to patients, policy makers and academic audiences as well as clinicians.

3.
J Clin Monit Comput ; 33(6): 1113-1118, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30623279

RESUMO

Accurately monitoring peri-operative core temperature is a cornerstone of good practice. Relatively invasive devices such as oesophageal temperature probes and pulmonary artery catheters facilitate this, but are inappropriate for many patients. There remains a need for accurate monitors of core temperature that can be used in awake patients. This study compared the accuracy of two core temperature thermometers that can be used for this purpose: the 3M Bair Hugger™ Temperature Monitoring System Zero Flux Thermometer and the CorTempR™ Wireless Ingestible Temperature Sensor. Readings were compared with the oesophageal probe, the current intraoperative standard. Thirty patients undergoing elective surgical procedures under general anaesthesia were recruited. The ingestible sensor was ingested prior to induction of anaethesia, and post induction, the zero-flux electrode attached above the right eyebrow and oesophageal probe inserted. During surgery, the temperature on each device was recorded every minute. Measurements were compared using Bland-Altman analysis. The ingestible sensor experienced interference from use of diathermy and fluoroscopy in the operating theatre, rendering 39% of its readings unusable. These were removed from analysis. With remaining readings the bias compared with oesophageal probe was + 0.42 °C, with 95% limits of agreement - 2.4 °C to 3.2 °C. 75.4% of readings were within ± 0.5 °C of the OTP reading. The bias for the zero flux electrode compared to oesophageal probe was + 0.02 °C with 95% limits of agreement - 0.5 °C to 0.5 °C. 97.7% of readings were within ± 0.5 °C of the oesophageal probe. The study findings suggest the zero-flux thermometer is sufficiently accurate for clinical use, whereas the ingestible sensor is not.Trial registration The study was registered at http://www.clinicaltrials.gov , NCT Number: NCT02121574.


Assuntos
Temperatura Corporal , Monitorização Intraoperatória/instrumentação , Período Perioperatório , Termômetros/normas , Termometria/instrumentação , Adolescente , Adulto , Idoso , Anestesia , Criança , Estudos Transversais , Eletrodos , Esôfago/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Monitorização Fisiológica/instrumentação , Reprodutibilidade dos Testes , Temperatura Cutânea , Temperatura , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA