Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 221
Filtrar
2.
J Thorac Dis ; 16(9): 6308-6319, 2024 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-39444914

RESUMO

This state-of-the-art review aimed to synthesize evidence from various sex-stratified studies on aortic stenosis (AS), focusing on the difference in clinical presentation, anatomical characteristics, pathophysiology, and management of AS. In comparison to men, women with AS are present at later stages, are older, more symptomatic, frailer, and exhibit higher operative risk [Society of Thoracic Surgeons (STS) score]. Women tend to have smaller aortic valve (AV) areas and left ventricular (LV) outflow tract, leading to lower stroke volumes (SVs) than men and have a higher prevalence of paradoxical, low-flow, low-gradient AS. In women, chronic pressure overload due to AS results in concentric LV remodelling and hypertrophy, characterized by reduced LV cavities, higher filling pressures, lower wall stress, and more diastolic dysfunction. Conversely, men exhibit more dilated eccentric LV remodelling and hypertrophy. AVs in women are less calcified but more fibrotic. Moreover, women are often underdiagnosed, have severity underestimated, and experience delays or receive fewer referrals for AV replacement (AVR). However, women tend to benefit from transcatheter AVR (TAVR) with a long-term survival advantage over men, although the incidence of vascular complications and bleeding events in 30 days after TAVR is higher in women. Surgical AVR (SAVR) in women has high operative risk, is technically demanding and has poorer outcomes with increased mortality at 30 days compared to men. According to the STS score and EuroSCORE, the female sex itself is considered a risk factor for SAVR. Therefore, addressing sex-related disparities in AS and increasing awareness among physicians promises improved diagnosis and treatment, facilitating equitable care and the development of sex-specific personalized medicine.

3.
EuroIntervention ; 20(17): e1076-e1085, 2024 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-39219361

RESUMO

BACKGROUND: Large datasets of transcatheter aortic valve implantation (TAVI) for pure aortic valve regurgitation (PAVR) are scarce. AIMS: We aimed to report procedural safety and long-term clinical events (CE) in a contemporary cohort of PAVR patients treated with new-generation devices (NGD). METHODS: Patients with grade III/IV PAVR enrolled in the FRANCE-TAVI Registry were selected. The primary safety endpoint was technical success (TS) according to Valve Academic Research Consortium 3 criteria. The co-primary endpoint was defined as a composite of mortality, heart failure hospitalisation and valve reintervention at last follow-up. RESULTS: From 2015 to 2021, 227 individuals (64.3% males, median age 81.0 [interquartile range {IQR} 73.5-85.0] years, with EuroSCORE II 6.0% [IQR 4.0-10.9]) from 41 centres underwent TAVI with NGD, using either self-expanding (55.1%) or balloon-expandable valves (44.9%; p=0.50). TS was 85.5%, with a non-significant trend towards increased TS in high-volume activity centres. A second valve implantation (SVI) was needed in 8.8% of patients, independent of valve type (p=0.82). Device size was ≥29 mm in 73.0% of patients, post-procedure grade ≥III residual aortic regurgitation was rare (1.2%), and the permanent pacemaker implantation (PPI) rate was 36.0%. At 30 days, the incidences of mortality and reintervention were 8.4% and 3.5%, respectively. The co-primary endpoint reached 41.6% (IQR 34.4-49.6) at 1 year, increased up to 61.8% (IQR 52.4-71.2) at 4 years, and was independently predicted by TS, with a hazard ratio of 0.45 (95% confidence interval: 0.27-0.76); p=0.003. CONCLUSIONS: TAVI with NGD in PAVR patients is efficient and reasonably safe. Preventing the need for an SVI embodies the major technical challenge. Larger implanted valves may have limited this complication, outweighing the increased risk of PPI. Despite successful TAVI, PAVR patients experience frequent CE at long-term follow-up.


Assuntos
Insuficiência da Valva Aórtica , Próteses Valvulares Cardíacas , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Insuficiência da Valva Aórtica/cirurgia , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Resultado do Tratamento , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Fatores de Risco , França
5.
BMC Med Educ ; 24(1): 979, 2024 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-39252033

RESUMO

BACKGROUND: Learning to interpret electrocardiograms (ECGs) is a crucial objective in medical education. Despite its importance, errors in ECGs interpretation are common, and the optimal teaching methods have not yet been clearly established. OBJECTIVES: To evaluate students' confidence in ECGs analysis and their opinion on current teaching methods, and to assess the effectiveness of a new ECG educational approach. METHODS: First, we conducted a survey on ECG learning among fourth to sixth-year medical students. Second, a 5-week multicenter comparative study was conducted with fourth-year medical students during their cardiology internship. Two different teaching methods were used, assigned by center. The first group participated in 5-minutes workshops 4 times a week using a "reversed classroom" method, supervised by a cardiologist, where students took turns selecting, presenting and discussing ECGs. The control group attended a single 2-hour face-to-face ECG course. All participants completed a 30-minute ECGs analysis test at baseline and after 5 weeks. RESULTS: Out of 401 survey respondents, the confidence levels in ECG interpretation were 3/5 (IQR 2-3) for routine situations and 2/5 (IQR 1-3) for emergency situations. Satisfaction with ECG teaching was low (2/5, IQR 1-3) and 96.3% of respondents favored more extensive ECG training. In the comparative study, 52 students from 3 medical schools were enrolled (control group: n = 27; workshop group: n = 25). Both groups showed significant improvement in exam scores from baseline to 5-week (33/100 ± 12/100 to 44/100 ± 12/100, p < 0.0001 for the control group and 36/100 ± 13/100 to 62/100 ± 12/100, p < 0.0001 for the workshop group). The improvement was significantly greater in the workshop group compared to the control group (+ 26 ± 11 vs. + 11 ± 6, p < 0.001). CONCLUSIONS: Among French medical students who initially reported low confidence and insufficient skills in ECG interpretation, the workshop approach using a "reversed classroom" method was found to be more effective than conventional lecture-based teaching during cardiology internship.


Assuntos
Competência Clínica , Eletrocardiografia , Estudantes de Medicina , Humanos , Competência Clínica/normas , Educação de Graduação em Medicina/métodos , Cardiologia/educação , Feminino , Masculino , Inquéritos e Questionários , Avaliação Educacional , Internato e Residência
6.
J Am Heart Assoc ; 13(19): e034456, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39319493

RESUMO

BACKGROUND: The percentage of women <50 years of age hospitalized with myocardial infarction is increasing. We describe the clinical, morphological, and biological characteristics, as well as the clinical outcomes of this population. METHODS AND RESULTS: This prospective, observational study included consecutive women <50 years of age admitted for myocardial infarction at 30 centers in France (May 2017-June 2019). The primary outcome was the composite of net adverse clinical events: all-cause death, cardiovascular death, recurrent myocardial infarction, stent thrombosis, any stroke, or major bleeding occurring during hospitalization with a 12-month follow up. Three hundred fourteen women were included. The mean age was 43.0 (±5.7) years, 60.8% presented with ST-segment-elevation myocardial infarction, 75.5% were current smokers, 31.2% had a history of complicated pregnancy, and 55.1% reported recent emotional stress. Most (91.6%) women presented with typical chest pain. Of patients on an estrogen-containing contraceptive, 86.0% had at least 1 contraindication. Of patients with ST-segment-elevation myocardial infarction, 17.8% had myocardial infarction with nonobstructive coronary arteries and 14.6% had spontaneous coronary artery dissection, whereas 29.3% presented with multivessel vessel disease. During hospitalization, 11 net adverse clinical events occurred in 9 (2.8%) women, but no deaths or stent thromboses occurred. By 12 months, 14 net adverse clinical events occurred in 10 (3.2%) women; 2 (0.6%) died (from progressive cancer) and 25 (7.9%) had an ischemia-driven repeat percutaneous coronary intervention. CONCLUSIONS: Most young women with myocardial infarction reported typical chest pain and had modifiable cardiovascular risk factors. History of adverse pregnancy outcomes and prescription of combined oral contraceptive despite a contraindication were prevalent, emphasizing the need for comprehensive cardiological and gynecological evaluation and follow-up. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03073447.


Assuntos
Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Feminino , França/epidemiologia , Estudos Prospectivos , Adulto , Pessoa de Meia-Idade , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/terapia , Infarto do Miocárdio/diagnóstico , Fatores de Risco , Fatores Etários , Hospitalização/estatística & dados numéricos , Causas de Morte
7.
Arch Cardiovasc Dis ; 117(8-9): 505-513, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38981841

RESUMO

BACKGROUND: Pacemaker implantation combined with atrioventricular node ablation (AVNA) is a well-established strategy for uncontrolled atrial arrhythmias. Limited data are available regarding His bundle pacing (HBP) and left bundle branch area pacing (LBBAP) in this setting. AIM: To compare the outcomes of HBP and LBBAP in patients undergoing pacemaker implantation combined with AVN in routine clinical practice. METHODS: We prospectively included all patients who underwent AVNA after successful conduction system pacing (CSP) in two hospitals between September 2017 and May 2023. The primary outcome was the 1-year composite of first episode of heart failure hospitalization, symptomatic atrioventricular node reconduction requiring a second AVNA procedure, lead revision or death from any cause. RESULTS: A total of 164 patients underwent AVNA following successful CSP (68 HBP and 96 LBBAP). Mean pacemaker implantation and AVNA procedure times were shorter in the LBBAP group than the HBP group (46±18 vs 59±23min; P<0.001 and 31±12 vs 43±22min, respectively; P<0.001). Complete atrioventricular block was more frequently obtained in the LBBAP group (88/96 patients [92%] vs 54/68 patients [79%]; P=0.04). One-year freedom from the composite outcome was more frequent in the LBBAP group (89.7% vs 72.9%; hazard ratio 0.32, 95% confidence interval 0.14-0.72; P=0.01). The strategy was similarly effective in both groups with a significant improvement in NYHA class and left ventricular ejection fraction. A secondary pacing threshold elevation >1V occurred only in the HBP group (11%). CONCLUSION: In this prospective, comparative study, LBBAP provided better 1-year outcomes than HBP.


Assuntos
Nó Atrioventricular , Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Humanos , Estudos Prospectivos , Masculino , Feminino , Fascículo Atrioventricular/fisiopatologia , Idoso , Nó Atrioventricular/fisiopatologia , Nó Atrioventricular/cirurgia , Resultado do Tratamento , Fatores de Tempo , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Frequência Cardíaca , Fatores de Risco , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/diagnóstico , Idoso de 80 Anos ou mais , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/cirurgia , Potenciais de Ação
8.
EuroIntervention ; 20(14): e845-e864, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39007831

RESUMO

Transcatheter aortic valve implantation (TAVI) is now utilised as a less invasive alternative to surgical aortic valve replacement (SAVR) across the whole spectrum of surgical risk. Long-term durability of the bioprosthetic valves has become a key goal of TAVI as this procedure is now considered for younger and lower-risk populations. The purpose of this article is to present a state-of-the-art overview on the definition, aetiology, risk factors, mechanisms, diagnosis, clinical impact, and management of bioprosthetic valve dysfunction (BVD) and failure (BVF) following TAVI with a comparative perspective versus SAVR. Structural valve deterioration (SVD) is the main factor limiting the durability of the bioprosthetic valves used for TAVI or SAVR, but non-structural BVD, such as prosthesis-patient mismatch and paravalvular regurgitation, as well as valve thrombosis or endocarditis may also lead to BVF. The incidence of BVF related to SVD or other causes is low (<5%) at midterm (5- to 8-year) follow-up and compares favourably with that of SAVR. The long-term follow-up data of randomised trials conducted with the first generations of transcatheter heart valves also suggest similar valve durability in TAVI versus SAVR at 10 years, but these trials suffer from major survivorship bias, and the long-term durability of TAVI will need to be confirmed by the analysis of the low-risk TAVI versus SAVR trials at 10 years.


Assuntos
Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Fatores de Risco , Bioprótese , Estenose da Valva Aórtica/cirurgia , Falha de Prótese , Resultado do Tratamento , Desenho de Prótese , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos
10.
Arch Cardiovasc Dis ; 117(6-7): 417-426, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38821761

RESUMO

BACKGROUND: Despite major advances in prevention and treatment, cardiovascular diseases - particularly acute myocardial infarction - remain a leading cause of death worldwide and in France. Collecting contemporary data about the characteristics, management and outcomes of patients with acute myocardial infarction in France is important. AIMS: The main objectives are to describe baseline characteristics, contemporary management, in-hospital and long-term outcomes of patients with acute myocardial infarction hospitalized in tertiary care centres in France; secondary objectives are to investigate determinants of prognosis (including periodontal disease and sleep-disordered breathing), to identify gaps between evidence-based recommendations and management and to assess medical care costs for the index hospitalization and during the follow-up period. METHODS: FRENCHIE (FRENch CoHort of myocardial Infarction Evaluation) is an ongoing prospective multicentre observational study (ClinicalTrials.gov Identifier: NCT04050956) enrolling more than 19,000 patients hospitalized for acute myocardial infarction with onset of symptoms within 48hours in 35 participating centres in France since March 2019. Main exclusion criteria are age<18 years, lack of health coverage and procedure-related myocardial infarction (types 4a and 5). Detailed information was collected prospectively, starting at admission, including demographic data, risk factors, medical history and treatments, initial management, with prehospital care pathways and medication doses, and outcomes until hospital discharge. The follow-up period (up to 20 years for each patient) is ensured by linking with the French national health database (Système national des données de santé), and includes information on death, hospital admissions, major clinical events, healthcare consumption (including drug reimbursement) and total healthcare costs. FRENCHIE is also used as a platform for cohort-nested studies - currently three randomized trials and two observational studies. CONCLUSIONS: This nationwide large contemporary cohort with very long-term follow-up will improve knowledge about acute myocardial infarction management and outcomes in France, and provide a useful platform for nested studies and trials.


Assuntos
Infarto do Miocárdio , Projetos de Pesquisa , Humanos , Infarto do Miocárdio/terapia , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/economia , Infarto do Miocárdio/epidemiologia , França/epidemiologia , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Fatores de Risco , Feminino , Masculino , Idoso , Mortalidade Hospitalar , Estudos Multicêntricos como Assunto , Pessoa de Meia-Idade , Custos Hospitalares
12.
Arch Cardiovasc Dis ; 117(5): 321-331, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38670869

RESUMO

BACKGROUND: Transcatheter (TAVR) has supplanted surgical (SAVR) aortic valve replacement (AVR). AIM: To evaluate whether adoption of this technology has varied according to centre volume at the nationwide level. METHODS: From an administrative hospital-discharge database, we collected data on all AVRs performed in France between 2007 and 2019. Centres were divided into terciles based on the annual number of SAVRs performed in 2007-2009 ("before TAVR era"). RESULTS: A total of 192,773 AVRs (134,662 SAVRs and 58,111 TAVRs) were performed in 47 centres. The annual number of AVRs and TAVRs increased significantly and linearly in low-volume (<152 SAVRs/year; median 106, interquartile range [IQR] 75-129), middle-volume (152-219 SAVRs/year; median 197, IQR 172-212) and high-volume (>219 SAVRs/year; median 303, IQR 268-513) terciles, but to a greater degree in the latter (+14, +16 and +24 AVRs/centre/year and +16, +19 and +31 TAVRs/centre/year, respectively; PANCOVA<0.001). Charlson Comorbidity Index and in-hospital death rates declined from 2010 to 2019 in all terciles (all Ptrend<0.05). In 2017-2019, after adjusting for age, sex and Charlson Comorbidity Index, there was a trend toward lower death rates in the high-volume tercile (P=0.06) for SAVR, whereas death rates were similar for TAVR irrespective of tercile (P=0.27). Similar results were obtained when terciles were defined based on number of interventions performed in the last instead of the first 3years. Importantly, even centres in the lowest-volume tercile performed a relatively high number of interventions (150 TAVRs/year/centre). CONCLUSIONS: In a centralized public healthcare system, the total number of AVRs increased linearly between 2007 and 2019, mostly due to an increase in TAVR, irrespective of centre volume. Progressive declines in patient risk profiles and death rates were observed in all terciles; in 2017-2019 death rates were similar in all terciles, although lower in high-volume centres for SAVR.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bases de Dados Factuais , Implante de Prótese de Valva Cardíaca , Hospitais com Alto Volume de Atendimentos , Hospitais com Baixo Volume de Atendimentos , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , França/epidemiologia , Hospitais com Alto Volume de Atendimentos/tendências , Substituição da Valva Aórtica Transcateter/tendências , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Feminino , Hospitais com Baixo Volume de Atendimentos/tendências , Masculino , Idoso , Resultado do Tratamento , Fatores de Tempo , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Fatores de Risco , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/tendências , Implante de Prótese de Valva Cardíaca/instrumentação , Padrões de Prática Médica/tendências , Medição de Risco , Estudos Retrospectivos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/mortalidade , Difusão de Inovações
14.
J Am Heart Assoc ; 13(6): e033146, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38471838

RESUMO

BACKGROUND: Cryoballoon ablation is currently the gold standard technique for single-shot pulmonary vein isolation (PVI). Pulsed field ablation (PFA) has recently emerged as an interesting nonthermal alternative energy for PVI. The purpose of our study was to evaluate the safety and long-term efficacy of PVI using the pentaspline PFA catheter in comparison to cryoballoon ablation. METHODS AND RESULTS: Between January 2021 and December 2022, we included all consecutive patients of our center in whom a first PVI-only procedure was performed using PFA or cryoballoon. The choice of the energy was based on patients' preference between general anesthesia (PFA) and local anesthesia (cryoballoon). The primary end point was freedom from documented atrial arrhythmia recurrence after a 3-month blanking period. A total of 301 patients (paroxysmal atrial fibrillation in 220 patients) underwent a first PVI procedure performed using PFA (n=151) or cryoballoon (n=150). Complete short-term PVI was obtained in 144 of 150 patients (96%) in the cryoballoon group and in all patients of the PFA group (P=0.01). Procedure duration was significantly longer in the cryoballoon group. Transient and persistent phrenic nerve injuries were observed in the cryoballoon group only (13/150 and 2/150, respectively). One-year freedom from atrial arrhythmia was significantly higher in the PFA group compared with the cryoballoon group (87.9% versus 77.7%; adjusted hazard ratio, 0.53 [95% CI, 0.30-0.96]; P=0.037). CONCLUSIONS: This prospective, comparative, real-life study suggested that PFA could overcome safety limitations of cryoballoon with optimal effectiveness. Randomized controlled studies are required to further investigate the potential superiority of PFA over cryoballoon.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Catéteres , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
15.
Arch Cardiovasc Dis ; 117(4): 249-254, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38494400

RESUMO

BACKGROUND: Pulsed field ablation has recently emerged as an interesting non-thermal energy for atrial fibrillation ablation. At a time of rapid spread of this technology, there is still a lack of prospective real-life data. AIM: To describe multicentre prospective safety and 1-year efficacy data in three of the first French centres to use pulsed field ablation. METHODS: All consecutive patients undergoing a first pulsed field ablation were included prospectively. The primary outcome was freedom from documented atrial arrhythmia. The safety endpoint was a composite of major adverse events. Univariate and multivariable analyses, including patient and procedural characteristics, were performed to identify factors predictive of recurrence. RESULTS: Between May 2021 and June 2022, 311 patients were included (paroxysmal atrial fibrillation in 53%, persistent atrial fibrillation in 35% and long-standing persistent atrial fibrillation in 11%). Additional non-pulmonary vein pulsed field ablation applications were performed in 104/311 patients. One-year freedom from arrhythmia recurrence was 77.6% in the overall population and was significantly higher in patients with paroxysmal atrial fibrillation (88.4%) compared with patients with persistent atrial fibrillation (69.7%; P<0.001) and those with long-standing persistent atrial fibrillation (49.0%; P<0.001). The major complication rate was 2.6% (tamponade in four patients, stroke in two patients and coronary spasm in one patient). Besides the usual predictors of recurrences (left atrium size, CHA2DS2-VASc score, type of atrial fibrillation), the presence of atrial fibrillation at procedure start was independently associated with arrhythmia recurrence (hazard ratio: 2.04, 95% confidence interval: 1.10-3.77). CONCLUSION: In this prospective multicentre real-world study, pulsed field ablation for atrial fibrillation ablation seems to be associated with a good safety profile and rather favourable acute and 1-year success rates.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Estudos Prospectivos , Resultado do Tratamento , Catéteres , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
16.
Int J Cardiol ; 406: 131996, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38555056

RESUMO

OBJECTIVE: Management of patients with severe aortic stenosis (AS) may differ according to the patient sex. This study aimed to describe patterns of aortic valve replacement (AVR) for severe AS across Europe, including stratification by sex. METHODS: Procedure volume data for surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI) for six years (2015-2020) were extracted from national databases for Austria, Czech Republic, Denmark, England, Finland, France, Germany, Norway, Poland, Spain, Sweden, and Switzerland and stratified by sex. Patients per million population (PPM) undergoing AVR per year were calculated using population estimates from Eurostat. RESULTS: Between 2015 and 2019, AVR procedures grew at an average annual rate of 3.9%. In 2020, the average total PPM undergoing AVR across all countries was 339, with 51% of procedures being TAVI and 49% SAVR. AVR PPM varied widely between countries, with the highest and lowest in Germany and Poland, respectively. The average total PPM was higher for men than women (423 vs. 258), but a higher proportion of women (62%) than men (44%) received TAVI. The proportion of TAVI among total AVR procedures increased with age, with an overall average of 96% of men and 98% of women aged ≥85 years receiving TAVI; however, adoption of TAVI varied by country. CONCLUSIONS: The analysis of temporal trends in the adoption of TAVI vs. SAVR across Europe showed significant variations. Despite the higher use of TAVI vs. SAVR in women, overall rates of AV intervention in women were lower compared to men.


Assuntos
Estenose da Valva Aórtica , Humanos , Feminino , Masculino , Europa (Continente)/epidemiologia , Idoso , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/epidemiologia , Idoso de 80 Anos ou mais , Fatores Sexuais , Substituição da Valva Aórtica Transcateter/tendências , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Implante de Prótese de Valva Cardíaca/tendências , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Valva Aórtica/cirurgia , Pessoa de Meia-Idade
17.
Eur Heart J ; 45(11): 952-962, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38437633

RESUMO

BACKGROUND AND AIMS: The length of stay (LOS) after transcatheter aortic valve implantation (TAVI) remains extremely variable whereas early discharge has been shown to be feasible and safe. The study objective was to evaluate the efficacy and safety of an intervention aimed at reducing LOS after transfemoral TAVI. METHODS: FAST-TAVI II is a prospective, multicentre, cluster, randomized, controlled study including patients with severe symptomatic aortic stenosis, who had transfemoral TAVI. The intervention consisted in a dedicated training programme to implement 10 quality of care measures to reduce LOS with an implementation phase of eight weeks. The primary endpoint was the proportion of patients discharged early within 3 days. Secondary endpoints included: LOS, 30-day mortality and 30-day incidence of readmission for cardiovascular events. RESULTS: During the study period, 969 patients were enrolled in the intervention group and 860 patients in the control group. Mean age was 81.9 ± 6.6 years and mean EuroSCORE II was 4.4 ± 4.5%. Early discharge was achieved in 563 (58.1%) patients in the intervention group vs. 364 (42.3%) patients in the control group (P < .0001). Median LOS was significantly reduced in the intervention group compared to the control group [3 (IQR: 3) vs. 4 days (IQR: 3), P < .0001]. Thirty-day mortality was low and similar in the two groups (0.5% vs. 0.9%, P = .30), as were 30-day readmissions (4.6% vs. 2.8%, P = .28). CONCLUSIONS: The intervention was simple and fast to implement, and was effective and safe to reduce LOS and increase the proportion of patients discharged early after TAVI (NCT04503655).


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Tempo de Internação , Estudos Prospectivos , Alta do Paciente , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
18.
Eur Heart J ; 45(13): 1104-1115, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38366821

RESUMO

Research performed in Europe has driven cardiovascular device innovation. This includes, but is not limited to, percutaneous coronary intervention, cardiac imaging, transcatheter heart valve implantation, and device therapy of cardiac arrhythmias and heart failure. An important part of future medical progress involves the evolution of medical technology and the ongoing development of artificial intelligence and machine learning. There is a need to foster an environment conducive to medical technology development and validation so that Europe can continue to play a major role in device innovation while providing high standards of safety. This paper summarizes viewpoints on the topic of device innovation in cardiovascular medicine at the European Society of Cardiology Cardiovascular Round Table, a strategic forum for high-level dialogue to discuss issues related to the future of cardiovascular health in Europe. Devices are developed and improved through an iterative process throughout their lifecycle. Early feasibility studies demonstrate proof of concept and help to optimize the design of a device. If successful, this should ideally be followed by randomized clinical trials comparing novel devices vs. accepted standards of care when available and the collection of post-market real-world evidence through registries. Unfortunately, standardized procedures for feasibility studies across various device categories have not yet been implemented in Europe. Cardiovascular imaging can be used to diagnose and characterize patients for interventions to improve procedural results and to monitor devices long term after implantation. Randomized clinical trials often use cardiac imaging-based inclusion criteria, while less frequently trials randomize patients to compare the diagnostic or prognostic value of different modalities. Applications using machine learning are increasingly important, but specific regulatory standards and pathways remain in development in both Europe and the USA. Standards are also needed for smart devices and digital technologies that support device-driven biomonitoring. Changes in device regulation introduced by the European Union aim to improve clinical evidence, transparency, and safety, but they may impact the speed of innovation, access, and availability. Device development programmes including dialogue on unmet needs and advice on study designs must be driven by a community of physicians, trialists, patients, regulators, payers, and industry to ensure that patients have access to innovative care.


Assuntos
Cardiologia , Procedimentos Cirúrgicos Torácicos , Humanos , Inteligência Artificial , Diagnóstico por Imagem , Técnicas de Imagem Cardíaca
19.
Arch Cardiovasc Dis ; 117(3): 213-223, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38388290

RESUMO

BACKGROUND: The influence of permanent pacemaker implantation upon outcomes after transcatheter aortic valve implantation (TAVI) remains controversial. AIMS: To evaluate the impact of permanent pacemaker implantation after TAVI on short- and long-term mortality, and on the risk of hospitalization for heart failure. METHODS: Data from the large FRANCE-TAVI registry, linked to the French national health single-payer claims database, were analysed to compare 30-day and long-term mortality rates and hospitalization for heart failure rates among patients with versus without permanent pacemaker implantation after TAVI. Multivariable regressions were performed to adjust for confounders. RESULTS: A total of 36,549 patients (mean age 82.6years; 51.6% female) who underwent TAVI from 2013 to 2019 were included in the present analysis. Among them, 6999 (19.1%) received permanent pacemaker implantation during the index hospitalization, whereas 232 (0.6%) underwent permanent pacemaker implantation between hospital discharge and 30days after TAVI, at a median of 11 (interquartile range: 7-18) days. In-hospital permanent pacemaker implantation was not associated with an increased risk of death between discharge and 30days (adjusted odds ratio: 0.91, 95% confidence interval: 0.64-1.29). At 5years, the incidence of all-cause death was higher among patients with versus without permanent pacemaker implantation within 30days of the procedure (adjusted hazard ratio: 1.13, 95% confidence interval: 1.07-1.19). Permanent pacemaker implantation within 30days of TAVI was also associated with a higher 5-year rate of hospitalization for heart failure (adjusted subhazard ratio: 1.17, 95% confidence interval: 1.11-1.23). CONCLUSIONS: Permanent pacemaker implantation after TAVI is associated with an increased risk of long-term hospitalization for heart failure and all-cause mortality. Further research to mitigate the risk of postprocedural permanent pacemaker implantation is needed as TAVI indications expand to lower-risk patients.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso de 80 Anos ou mais , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Resultado do Tratamento , Sistema de Registros , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Valva Aórtica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA