RESUMO
Background: JenaValve's Trilogy transcatheter heart valve (THV) (JenaValve Inc, Irvine, CA) is the only conformité européenne-marked THV system for the treatment of aortic regurgitation (AR) or aortic stenosis (AS). However, its efficacy has not been quantitatively investigated pre- and post-implantation using video-densitometric analysis. Methods: Using the CAAS-A-Valve 2.1.2 software (Pie Medical Imaging, Maastricht, the Netherlands), an independent core lab retrospectively analyzed the aortograms of 88 consecutive patients (68 severe AR; 20 severe AS) receiving the JenaValve THV in three European centers. Video-densitometric AR was categorized by the regurgitant fraction (RF) as none/trace AR (RF ≤ 6%), mild (6% < RF ≤ 17%), and moderate/severe AR (RF > 17%). Results: Pre- and post-THV aortograms were analyzable in 17 (22.4%) and 47 (54.0%) patients, respectively. The main reasons preventing analysis were the descending aorta overlap of the outflow tract (30%) and insufficient frame count (6%). The median RF pre- and post-THV implant was 31.0% (interquartile range 21.5-38.6%) and 5.0% (interquartile range 1.0-7.0%, p < 0.001), respectively. The post-THV incidence of none/trace AR was 72.3%, and of mild AR, 27.7%, with no cases of moderate/severe AR. Video-densitometry analysis of the 12 AR cases with paired pre- and post-THV showed a reduction in the RF of 21.8% ± 8.1%. Conclusions: Quantitative aortography confirms the low rates of AR and the large reduction in RF following the implantation of Jenavalve's Trilogy THV, irrespective of implant indication. However, these limited data need corroborating in prospective studies using standardized acquisition protocols.
RESUMO
BACKGROUND: Transcatheter aortic valve implantation is an established, guideline-endorsed treatment for severe aortic stenosis. Precise sizing of the balloon-expandable Myval transcatheter heart valve (THV) series with the aortic annulus is facilitated by increasing its diameter in 1·5 mm increments, compared with the usual 3 mm increments in valve size. The LANDMARK trial aimed to show non-inferiority of the Myval THV series compared with the contemporary THVs Sapien Series (Edwards Lifesciences, Irvine, CA, USA) or Evolut Series (Medtronic, Minneapolis, MN, USA). METHODS: In this prospective, multinational, randomised, open-label, non-inferiority trial across 31 hospitals in 16 countries (Germany, France, Sweden, the Netherlands, Italy, Spain, New Zealand, Portugal, Greece, Hungary, Poland, Slovakia, Slovenia, Croatia, Estonia, and Brazil), 768 participants with severe symptomatic native aortic stenosis were randomly assigned (1:1) to the Myval THV or a contemporary THV. Eligibility was primarily decided by the heart team in accordance with 2021 European Society of Cardiology guidelines. As per the criteria of the third Valve Academic Research Consortium, the primary endpoint at 30 days was a composite of all-cause mortality, all stroke, bleeding (types 3 and 4), acute kidney injury (stages 2-4), major vascular complications, moderate or severe prosthetic valve regurgitation, and conduction system disturbances resulting in a permanent pacemaker implantation. Non-inferiority of the study device was tested in the intention-to-treat population using a non-inferiority margin of 10·44% and assuming an event rate of 26·10%. This trial is registered with ClinicalTrials.gov, NCT04275726, and EudraCT, 2020-000137-40, and is closed to new participants. FINDINGS: Between Jan 6, 2021, and Dec 5, 2023, 768 participants with severe symptomatic native aortic stenosis were randomly assigned, 384 to the Myval THV and 384 to a contemporary THV. 369 (48%) participants had their sex recorded as female, and 399 (52%) as male. The mean age of participants was 80·0 years (SD 5·7) for those treated with the Myval THV and 80·4 years (5·4) for those treated with a contemporary THV. Median Society of Thoracic Surgeons scores were the same in both groups (Myval 2·6% [IQR 1·7-4·0] vs contemporary 2·6% [1·7-4·0]). The primary endpoint showed non-inferiority of the Myval (25%) compared with contemporary THV (27%), with a risk difference of -2·3% (one-sided upper 95% CI 3·8, pnon-inferiority<0·0001). No significant difference was seen in individual components of the primary composite endpoint. INTERPRETATION: In individuals with severe symptomatic native aortic stenosis, the Myval THV met its primary endpoint at 30 days. FUNDING: Meril Life Sciences.
Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Desenho de Prótese , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/métodos , Resultado do TratamentoRESUMO
PURPOSE: To evaluate the safety and effectiveness of the novel, next-generation Myval Octacor - Transcatheter Heart Valve (THV) in patients with severe, symptomatic, native aortic stenosis (AS). METHODS: This multicenter, real-world observational registry included 123 patients with severe symptomatic AS, across 16 Indian centers who underwent treatment with the novel Myval Octacor THV. Study endpoints included all-cause mortality, all stroke, acute kidney injury (AKI), major vascular complications, moderate or severe paravalvular leakage (PVL) and new permanent pacemaker implantation (PPI) until 30 days follow-up. RESULTS: Of the 123 patients (average age 70.07 ± 8.33 years), 37.4 % (n = 46) were female and 39.84 % presented with bicuspid valves. The technical success rate of the procedure was 100 % and the device success rate at 30 days was 98.4 %. At 30 days (n = 123) after the procedure, the overall mortality was 1.6 %. AKI occurred in 1.6 % of patients and there was no incidence of stroke, bleeding (types 3 and 4), and major vascular complications. In an analysis of 31 patients whose echocardiographic parameters were available across all timepoints, there were significant improvements in the mean pressure gradient (54.31 ± 18.19 mmHg vs. 10.42 ± 4.24 mmHg; p < 0.0001) and effective orifice area (0.66 ± 0.21 cm2 vs. 1.80 ± 0.44 cm2; p < 0.0001) from baseline to the 30-day follow-up. None of the patients experienced severe PVL, while moderate PVL was observed in two patients (1.6 %). CONCLUSIONS: Early outcomes of the next-generation, novel Myval Octacor THV proved its safety and effectiveness in the treatment of severe AS.
Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Resultado do Tratamento , Idoso , Índia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Fatores de Tempo , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Fatores de Risco , Recuperação de Função Fisiológica , Complicações Pós-Operatórias , Estudos Retrospectivos , HemodinâmicaRESUMO
BACKGROUND: ACURATE neo2 (Neo2) implantation is performed after systematic Balloon Aortic Valvuloplasty (BAV) in most patients. No reports exist about the feasibility and safety of direct Neo2 transcatheter aortic valve implantation (TAVI) in comparison to the standard practice. AIM: We aimed to identify the patients' baseline anatomical characteristics, procedural, and early post-procedural outcomes in patients treated using Neo2 with and without BAV. METHODOLOGY: This is a retrospective multicentre analysis of 499 patients with severe aortic stenosis who underwent TAVI using Neo2. The comparison was done according to the performance or omission of BAV. Echocardiography and computed tomography were analysed by an independent Core Lab. Propensity score matching (PSM) was performed based on the annular diameter and AV calcium volume, which identified 84 matched pairs. RESULTS: Among the cohort included, 391 (78%) patients received BAV (BAV-yes) and 108 (22%) were not attempted (BAV-no or Direct TAVI). Patients in BAV-no cohort had smaller annular diameter (22.6 vs 23.4 mm; p < 0.001) and lower calcium volume (163 vs 581 mm3; p < 0.001) compared to BAV-yes cohort. In the matched cohort, VARC-3 device technical success was similar (95%) and all other outcome measures were statistically comparable between cohorts. CONCLUSION: Direct TAVI using ACURATEneo2 without pre-TAVI balloon aortic valvuloplasty in patients with mild or less valve calcifications might be feasible and associated with comparable early outcomes compared to patients with similar anatomical features undergoing systematic balloon valvuloplasty.
Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/métodos , Cálcio , Resultado do Tratamento , Estudos Retrospectivos , Desenho de PróteseRESUMO
INTRODUCTION: Transcatheter aortic valve implantation (TAVI) is becoming the standard of care for severe symptomatic aortic stenosis (AS). Yet, some patients with AS are not indicated/eligible for TAVI. Several noninvasive, catheter-based or surgical alternatives exist, and other therapeutic options are emerging. AREAS COVERED: This review provides an overview of non-TAVI options for severe AS. Non-invasive, transcatheter, and alternative surgical strategies are discussed, emphasizing their backgrounds, techniques, and outcomes. EXPERT OPINION: Alternative therapies to TAVI, whether device-based or non-device-based, continue to evolve or emerge and provide either alternative treatments or a bridge to TAVI, for patients not meeting indications for, or having contraindications to TAVI.Although TAVI and SAVR are the current dominant therapies, there are still some patients that could benefit in the future from other alternatives.Data on alternative options for such patients are scarce. Many advantages and disadvantages arise when selecting a specific treatment strategy for individual patients.Head-to-head comparison studies could guide physicians toward better patient selection and procedural planning. Awareness of therapeutic options, indications, techniques, and outcomes should enable heart teams to achieve optimized patient selection. Furthermore, it can increase the use of these alternatives to optimize the management of AS among different patient populations.
Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Fatores de RiscoRESUMO
BACKGROUND: Estimation of regurgitant fraction by videodensitometry (VD-AR) of aortic root angiograms is a new tool for objective grading of paravalvular regurgitation (PVR) after transcatheter aortic valve implantation (TAVI). Stratification with boundaries at 6% and 17% has been proposed to reflect "none/trace", "mild" and "moderate or higher" PVR. OBJECTIVE: We sought to investigate the association of strata of VD-AR with 3-year mortality and to compare VD-AR with visual grading of angiograms. METHODS: We interrogated our database for patients undergoing transfemoral TAVI from 2008 to 2018. Vital status of the patients was obtained from population registers. To test differences in survival and estimate adjusted hazard ratios (HRs) we fitted Cox models. RESULTS: Our retrospective study included 699 patients with evaluable angiograms at completion of the TAVI procedure. Cumulative 3-year mortality was 35.0% in 261 (37.3%) patients with VD-AR < 6%, 33.9% in 325 (46.5%) patients with VD-AR between 6 and 17% (HR [95% confidence interval] 1.06 [0.80-1.42]; P = 0.684) and 47.2% in 113 (16.2%) patients with VD-AR > 17% (HR 1.57 [1.11-2.22]; P = 0.011). Visually, PVR was graded as "none/trace" in 470 (67.2%) patients, as "mild" in 219 (31.3%) and as "moderate" in 10 (1.4%). Both mild PVR and moderate PVR on visual grading were significantly associated with mortality (HRs 1.31 [1.12-1.54]; P = 0.001 and 1.92 [1.13-3.24]; P = 0.015; respectively). CONCLUSIONS: VD-AR > 17%, but not VD-AR 6-17%, was independently associated with mortality. Compared with subjective visual evaluation, VD-AR resulted in a smaller proportion of patients with PVR classified as prognostically relevant.
Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Angiografia , Modelos de Riscos Proporcionais , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Resultado do Tratamento , Índice de Gravidade de DoençaRESUMO
INTRODUCTION: Transcatheter aortic valve implantation (TAVI) is the standard of care for selected patients with severe aortic stenosis, irrespective of the surgical risk. Over the last two decades of TAVI practice, multiple limitations were identified. In addition, the extension of TAVI into a wider patient spectrum created new challenges. AREAS COVERED: This review provides an overview of emerging transcatheter heart valves (THVs) beyond the approved contemporary THVs for the treatment of aortic stenosis. EXPERT OPINION: The incidence of degenerative aortic stenosis is expected to increase with more aging of the population. Therefore, TAVI needs to meet this increase in the number of patients indicated for aortic valve replacement alongside a wide and complex anatomical variability. An increasing number of Aortic THVs are available in the market. This includes upgraded iterations of contemporary devices and innovative devices developed by emerging manufacturers. The new devices aim for the reduction or elimination of undesirable outcomes like paravalvular leakage and conduction disturbances requiring permanent pacemaker implantation. Alternatively, emerging THVs should provide feasibility regarding yet unproven TAVI indications like Bicuspid aortic valve, aortic regurgitation, or very large anatomy. Furthermore, some of the emerging THVs are designed to tackle the long-term durability issue of biological valves.
Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Resultado do Tratamento , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversosRESUMO
Paravalvular leak (PVL) is a shortcoming that can erode the clinical benefits of transcatheter valve replacement (TAVR) and therefore a readily applicable method (aortography) to quantitate PVL objectively and accurately in the interventional suite is appealing to all operators. The ratio between the areas of the time-density curves in the aorta and left ventricular outflow tract (LVOT-AR) defines the regurgitation fraction (RF). This technique has been validated in a mock circulation; a single injection in diastole was further tested in porcine and ovine models. In the clinical setting, LVOT-AR was compared with trans-thoracic and trans-oesophageal echocardiography and cardiac magnetic resonance imaging. LVOT-AR > 17% discriminates mild from moderate aortic regurgitation on echocardiography and confers a poor prognosis in multiple registries, and justifies balloon post-dilatation. The LVOT-AR differentiates the individual performances of many old and novel devices and is being used in ongoing randomized trials and registries.
RESUMO
(1) Background: Conduction disturbance requiring a new permanent pacemaker (PPM) after transcatheter aortic valve implantation (TAVI) has traditionally been a common complication. New implantation techniques with self-expanding platforms have reportedly reduced the incidence of PPM. We sought to investigate the predictors of PPM at 30 days after TAVI using Evolut R/PRO/PRO+; (2) Methods: Consecutive patients who underwent TAVI with the Evolut platform between October 2019 and August 2022 at University Hospital Galway, Ireland, were included. Patients who had a prior PPM (n = 10), valve-in-valve procedures (n = 8) or received >1 valve during the index procedure (n = 3) were excluded. Baseline clinical, electrocardiographic (ECG), echocardiographic and multislice computed tomography (MSCT) parameters were analyzed. Pre-TAVI MSCT analysis included membranous septum (MS) length, a semi-quantitative calcification analysis of the aortic valve leaflets, left ventricular outflow tract, and mitral annulus. Furthermore, the implantation depth (ID) was measured from the final aortography. Multivariate binary logistic analysis and receiver operating characteristic (ROC) curve analysis were used to identify independent predictors and the optimal MS and ID cutoff values to predict new PPM requirements, respectively; (3) Results: A total of 129 TAVI patients were included (age = 81.3 ± 5.3 years; 36% female; median EuroSCORE II 3.2 [2.0, 5.4]). Fifteen patients (11.6%) required PPM after 30 days. The patients requiring new PPM at 30 days were more likely to have a lower European System for Cardiac Operative Risk Evaluation II, increased prevalence of right bundle branch block (RBBB) at baseline ECG, have a higher mitral annular calcification severity and have a shorter MS on preprocedural MSCT analysis, and have a ID, as shown on the final aortogram. From the multivariate analysis, pre-TAVI RBBB, MS length, and ID were shown to be predictors of new PPM. An MS length of <2.85 mm (AUC = 0.85, 95%CI: (0.77, 0.93)) and ID of >3.99 mm (area under the curve (AUC) = 0.79, (95% confidence interval (CI): (0.68, 0.90)) were found to be the optimal cut-offs for predicting new PPM requirements; (4) Conclusions: Membranous septum length and implantation depth were found to be independent predictors of new PPM post-TAVI with the Evolut platform. Patient-specific implantation depth could be used to mitigate the requirement for new PPM.
RESUMO
BACKGROUND: The balloon expandable Myval transcatheter heart valve (THV) showed encouraging results regarding residual aortic regurgitation (AR) from multiple observational studies. The newly designed Myval Octacor has been introduced recently, aiming for a reduction in AR and improved performance. OBJECTIVES: The focus of this study is to report the incidence of AR using the validated quantitative Videodensitometry angiography technology (qLVOT-AR%) in the first in human use of the Myval Octacor THV system. METHODOLOGY: We report on the first in human use of the Myval Octacor THV system in 125 patients in 18 Indian centres. Independent retrospective analysis of the final aortograms following implantation of the Myval Octacor was performed using the CAAS-A-Valve software. AR is reported as a regurgitation fraction. The previously validated cutoff values have been used to identify ≥moderate AR (RF% >17%), mild (6% < RF% ≤17%), and none or trace AR (RF% ≤ 6%). RESULTS: Final aortogram was analysable for 103 patients (84.4%) among the 122 available aortograms. 64 (62%) patients, had tricuspid aortic valve (TAV), 38 (37%) with bicuspid AV (BAV), and one with unicuspid AV. The median absolute RF% was 2% [1, 6], moderate or more AR incidence was 1.9%, mild AR in 20.4%, and none or trace AR in 77.7%. The two cases with RF% >17% were in the BAV group. CONCLUSION: The initial results of Myval Octacor using quantitative angiography-derived regurgitation fraction demonstrated a favourable outcome regarding residual AR, possibly due to improved device design. Results must be confirmed in a larger randomised study, including other imaging modalities.
Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Aortografia/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
BACKGROUND: Bicuspid aortic valve (BAV) affects approximately 1.5% of the general population and is seen in nearly 50% of candidates for aortic valve replacement (AVR). Despite increasingly utilised transcatheter aortic valve implantation (TAVI) in aortic stenosis (AS) patients, its use among patients with severe bicuspid AS is limited as BAV is a heterogeneous disease associated with multiple and complex anatomical challenges. AIM: To investigate the one-year outcomes of TAVI using the balloon-expandable Myval transcatheter heart valve (THV) (Meril Life Sciences Pvt. Ltd., Vapi, India) in patients with severe bicuspid AS. METHODS AND RESULTS: We collected data from consecutive patients with bicuspid AS who underwent TAVI with the Myval THV and had at least one-year follow-up. Baseline characteristics, procedural, and 30-day echocardiographic and clinical outcomes were collected. Sixty-two patients were included in the study. The median age was 72 [66.3, 77.0] years, 45 (72.6%) were males, and the mean STS PROM score was 3.2 ± 2.2%. All TAVI procedures were performed via the transfemoral route. The median follow-up duration was 13.5 [12.2, 18.3] months; all-cause mortality was reported in 7 (11.3%) patients and cardiovascular hospitalisation in 6 (10.6%) patients. All-stroke was reported in 2 (3.2%), permanent pacemaker implantation 5 (8.3%), and myocardial infarction 1 (1.6%) patients. The echocardiographic assessment revealed a mean pressure gradient of 10 [8, 16.5] mmHg, effective orifice area 1.7 [1.4, 1.9] cm2, moderate AR in 1 (2%), mild AR in 14 (27%), and none/trace AR in 37 (71%). In total, 1 patient was diagnosed with valve thrombosis (2.1%), Stage II (moderate) haemodynamic deterioration was seen in 3 (6.4%), and stage III (severe) haemodynamic deterioration in 1 (2.1%) patient. CONCLUSIONS: TAVI with the Myval THV in selected BAV anatomy is associated with favourable one-year hemodynamic and clinical outcomes.
RESUMO
OBJECTIVES: Early right-sided heart failure (RHF) was seen in 22% of recipients of a left ventricular assist device (LVAD) in the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). However, the optimal treatment of post-LVAD RHF is not well known. Levosimendan has proven to be effective in patients with cardiogenic shock and in those with end-stage heart failure. We sought to evaluate the efficacy of levosimendan on post-LVAD RHF and 30-day and 1-year mortality. METHODS: The EUROMACS Registry was used to identify adults with mainstream continuous-flow LVAD implants who were treated with preoperative levosimendan compared to a propensity matched control cohort. RESULTS: In total, 3661 patients received mainstream LVAD, of which 399 (11%) were treated with levosimendan pre-LVAD. Patients given levosimendan had a higher EUROMACS RHF score [4 (2- 5.5) vs 2 (2- 4); P < 0.001], received more right ventricular assist devices (RVAD) [32 (8%) vs 178 (5.5%); P = 0.038] and stayed longer in the intensive care unit post-LVAD implant [19 (8-35) vs 11(5-25); P < 0.001]. Yet, there was no significant difference in the rate of RHF, 30-day, or 1-year mortality. Also, in the matched cohort (357 patients taking levosimendan compared to an average of 622 controls across 20 imputations), we found no evidence for a difference in postoperative severe RHF, RVAD implant rate, length of stay in the intensive care unit or 30-day and 1-year mortality. CONCLUSIONS: In this analysis of the EUROMACS registry, we found no evidence for an association between levosimendan and early RHF or death, albeit patients taking levosimendan had much higher risk profiles. For a definitive conclusion, a multicentre, randomized study is warranted.
Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Adulto , Humanos , Coração Auxiliar/efeitos adversos , Simendana , Pontuação de Propensão , Estudos Retrospectivos , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/cirurgia , Sistema de Registros , Resultado do TratamentoRESUMO
BACKGROUND: This paper looks to validate the risk score from the Heart Failure Association of the European Society of Cardiology and the International Cardio-Oncology Society (HFA-ICOS) for predicting potential cardiotoxicity from anticancer therapy for patients positive for human epidermal growth factor receptor 2. METHODS: A total of 507 patients with at least five years since index diagnosis of breast cancer were retrospectively divided according to the HFA-ICOS risk proforma. According to level of risk, these groups were assessed for rates of cardiotoxicity via mixed-effect Bayesian logistic regression model. RESULTS: A follow-up of five years observed cardiotoxicity of 3.3% (n = 3) in the low-risk, 3.3% (n = 10) in the medium-risk, 4.4% (n = 6) in the high-risk, and 38% (n = 6) in the very-high-risk groups respectively. For cardiac events related to treatment, the risk was significantly higher for the very-high-risk category of HFA-ICOS compared to other categories (Beta = 3.1, 95% CrI: 1.5, 4.8). For overall cardiotoxicity related to treatment, the area under the curve was 0.643 (CI 95%: 0.51, 0.76), with 26.1% (95% CI: 8%, 44%) sensitivity and 97.9% (95% CI: 96%, 99%) specificity. CONCLUSIONS: The HFA-ICOS risk score has moderate power in predicting cancer therapy-related cardiotoxicity in HER2-positive breast cancer patients.
Assuntos
Aneurisma da Aorta Ascendente , Aneurisma Aórtico , Insuficiência da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Aneurisma Aórtico/complicações , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversosAssuntos
Insuficiência da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
Transcatheter aortic valve replacement (TAVR) is a recommended intervention for selected population with severe aortic stenosis (AS). Bicuspid aortic valve (BAV) anatomy has been categorized as an unfavorable anatomy for TAVR due to multiple considerations as exclusion from randomized trials in addition to the challenging and unpredictable anatomy. The anatomical constraints of BAV include the large anatomy of the annulus, sinus of Valsalva, and aorta (aortopathy), in addition to significant calcifications of the device landing zone. Most commercial transcatheter heart valves (THV) have upper dimension limits of the annulus and area in which the device can be implanted safely without significant oversizing. Myval-XL THVs (Meril Life Sciences Pvt. Ltd., India) are balloon-expandable valves (BEV) that have been developed with two new sizes, 30.5 and 32 mm, aiming to treat patients with large annulus dimensions and that exceed the upper limit of an ordinary device's sizing matrix. This case series report describes TAVR using the XL-Myval 32 mm THV in three European patients with symptomatic severe bicuspid aortic stenosis with significant calcifications and large annular dimensions exceeding the limits of the other THVs.
RESUMO
(1) Background: Hemodynamic assessment of prosthetic heart valves using conventional 2D transthoracic Echocardiography-Doppler (2D-TTE) has limitations. Of those, left ventricular outflow tract (LVOT) area measurement is one of the major limitations of the continuity equation, which assumes a circular LVOT. (2) Methods: This study comprised 258 patients with severe aortic stenosis (AS), who were treated with the ACURATE neo2. The LVOT area and its dependent Doppler-derived parameters, including effective orifice area (EOA) and stroke volume (SV), in addition to their indexed values, were calculated from post-TAVI 2D-TTE. In addition, the 3D-LVOT area from pre-procedural MDCT scans was obtained and used to calculate corrected Doppler-derived parameters. The incidence rates of prosthesis patient mismatch (PPM) were compared between the 2D-TTE and MDCT-based methods (3) Results: The main results show that the 2D-TTE measured LVOT is significantly smaller than 3D-MDCT (350.4 ± 62.04 mm2 vs. 405.22 ± 81.32 mm2) (95% Credible interval (CrI) of differences: -55.15, -36.09), which resulted in smaller EOA (2.25 ± 0.59 vs. 2.58 ± 0.63 cm2) (Beta = -0.642 (95%CrI of differences: -0.85, -0.43), and lower SV (73.88 ± 21.41 vs. 84.47 ± 22.66 mL), (Beta = -7.29 (95% CrI: -14.45, -0.14)), respectively. PPM incidence appears more frequent with 2D-TTE- than 3D-MDCT-corrected measurements (based on the EOAi) 8.52% vs. 2.32%, respectively. In addition, significant differences regarding the EOA among the three valve sizes (S, M and L) were seen only with the MDCT, but not on 2D-TTE. (4) Conclusions: The corrected continuity equation by combining the 3D-LVOT area from MDCT with the TTE Doppler parameters might provide a more accurate assessment of hemodynamic parameters and PPM diagnosis in patients treated with TAVI. The ACURATE neo2 THV has a large EOA and low incidence of PPM using the 3D-corrected LVOT area than on 2D-TTE. These findings need further confirmation on long-term follow-up and in other studies.
RESUMO
Left ventricular assist device (LVAD) therapy has been instrumental in saving lives of patients with end-stage heart failure (HF). Recent generation devices have short-to-mid-term survival rates close to heart transplantation. Unfortunately, up to 1 in 4 patients develop a life-threatening right-sided HF (RHF) early post LVAD implantation, with high morbidity and mortality rate, necessitating prolonged ICU stay, prolonged inotropic support, and implantation of a right-ventricular assist device. Pre-operative optimization of HF therapy could help in prevention, and/or mitigation of RHF. Levosimendan (LEVO) is a non-conventional inotropic agent that works by amplifying calcium sensitivity of troponin C in cardiac myocytes, without increasing the intra-cellular calcium or exacerbating ischemia. LEVO acts as an inodilator, which reduces the cardiac pre-, and after-load. LEVO administration is associated with hemodynamic improvements. Despite decades long of the use of LVAD and more than two decades of the use of LEVO for HF, the literature on LEVO use in LVAD is very limited. In this paper, we sought to conduct a systematic review to synthesize evidence related to the use of LEVO for the mitigation and/or prevention of RHF in patients undergoing LVAD implantation.
RESUMO
Cancer-therapy related cardiotoxicity (CTRCT) is a significant and frequent complication of monoclonal antibody directed therapy, especially Trastuzumab, for human epidermal growth factor receptor 2 (HER2) overexpressing breast cancers. Reliable, clinically available molecular predictive markers of CTRCT have not yet been developed. Identifying specific genetic variants and their molecular markers, which make the host susceptible to this complication is key to personalised risk stratification. A systematic review was conducted until April 2021, using the Medline, Embase databases and Google Scholar, to identify studies genetic and RNA-related markers associated with CTRCT in HER2 positive breast cancer patients. So far, researchers have mainly focused on HER2 related polymorphisms, revealing codons 655 and 1170 variants as the most likely SNPs associated with cardiotoxicity, despite some contradictory results. More recently, new potential genetic markers unrelated to the HER2 gene, and linked to known cardiomyopathy genes or to genes regulating cardiomyocytes apoptosis and metabolism, have been detected. Moreover, microRNAs are gaining increasing recognition as additional potential molecular markers in the cardio-oncology field, supported by encouraging preliminary data about their relationship with cardiotoxicity in breast cancers. In this review, we sought to synthesize evidence for genetic variants and RNA-related molecular markers associated with cardiotoxicity in HER2-positive breast cancer.