Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Environ Sci Pollut Res Int ; 31(3): 4111-4129, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38097843

RESUMO

The paradigm of using metal biomaterials could be viewed from two sides - treatment of wide spectrum of degenerative diseases, and debris release from materials. After implant insertion, metal nanoparticles (NPs) and ions are released not only upon the first contact with cells/tissues, but in continual manner, which is immediately recognized by immune cells. In this work, the effects of metal nanoparticles (TiO2, Ni) and ions (Ni2+, Co2+, Cr3+, Mo6+) on primary human M0 macrophages from the blood samples of osteoarthritic patients undergoing total arthroplasty were studied in order to monitor immunomodulatory effects on the cells in a real-time format. The highest NiNPs concentration of 10 µg/ml had no effect on any of macrophage parameters, while the Ni2+ ions cytotoxicity limit for the cells is 0.5 mM. The cytotoxic effects of higher Ni2+ concentration revealed mitochondrial network fragmentation leading to mitochondrial dysfunction, accompanied by increased lysosomal activity and changes in pro-apoptotic markers. The suppression of M2 cell formation ability was connected to presence of Ni2+ ions (0.5 mM) and TiO2NPs (10 µg/ml). The immunomodulatory effect of Mo6+ ions, controversially, inhibit the formation of the cells with M1 phenotype and potentiate the thread-like shape M2s with increased chaotic cell movement. To summarize, metal toxicity depends on the debris form. Both, metal ions and nanoparticles affect macrophage size, morphological and functional parameters, but the effect of ions is more complex and likely more harmful, which has potential impact on healing and determines post-implantation reactions.


Assuntos
Nanopartículas Metálicas , Metais , Humanos , Metais/farmacologia , Macrófagos , Íons
2.
Jt Dis Relat Surg ; 34(3): 557-564, 2023 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-37750259

RESUMO

OBJECTIVES: The purpose of our study was to compare the complication rate and the outcomes of custom-made spacers (C-spacers) and prefabricated articular spacers (P-spacers) in the treatment of periprosthetic infection. PATIENTS AND METHODS: In this retrospective study, 78 patients (44 females, 34 males; mean age: 68.5±9.48 years; range, 47 to 82 years) with articular spacers implanted in our institution were analyzed between January 2009 and December 2019. We recorded implant results as per mechanical complications, infection control, the interval from surgery to definitive hip replacement, and the rate of achieving recovery of joint function after stage two arthroplasty. RESULTS: There were 29 revised spacers; 18 of them were C-spacers and 11 were P-spacers (p=0.0383). A total of 16 dislocations were recorded, of which six were dislocations of C-spacers, and 10 were dislocations of P-spacers (p=0.0082). Additionally, we registered four spacer breakages, all of which occurred in C-spacers (p=0.295). C-spacers failed early, at an mean interval of 2.2 weeks after implantation, and P-spacers failed later, with an mean of 9.3 weeks after implantation (p=0.0187). A total of nine reinfection complications of spacers were registered; only one infection of P-spacers, and eight infections related to C-spacers (p=0.2583). Definitive revision total hip arthroplasty (rTHA) after spacer explantation and successful treatment of the infection occurred in 63 cases out of 78 patients. Definitive rTHA occurred after the use of C-spacers in 41 (78%) patients and after the use of C-spacers in 22 (84%) patients (p=0.7816). C-spacers had a mean interval from spacer implantation to definitive rTHA of 6.56±6.03 months, and P-spacers had a mean interval of 4±1.93 months (p=0.0164). CONCLUSION: Custom-made spacers were shown to have lower mechanical complication rates than prefabricated ones but more infection complications. Prefabricated spacers had more dislocations and fewer breakages. Custom-made spacer mechanical failures occurred earlier compared to prefabricated ones.


Assuntos
Artroplastia de Quadril , Luxações Articulares , Feminino , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Artroplastia de Quadril/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Controle de Infecções
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA