Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Bone Joint Surg Br ; 92(6): 856-61, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20513885

RESUMO

Between 1988 and 1998 we implanted 318 total hip replacements (THRs) in 287 patients using the Plasmacup (B. Braun Ltd, Sheffield, United Kingdom) and a conventional metal-on-polyethylene articulation. The main indications for THR were primary or secondary osteoarthritis. At follow-up after a mean 11.6 years (7.6 to 18.4) 17 patients had died and 20 could not be traced leaving a final series of 280 THRs in 250 patients. There were 62 revisions (22.1%) in 59 patients. A total of 43 acetabular shells (15.4%) had been revised and 13 (4.6%) had undergone exchange of the liner. The most frequent indications for revision were osteolysis and aseptic loosening, followed by polyethylene wear. The mean Kaplan-Meier survival of the Plasmacup was 91% at ten years and 58% at 14 years. Osteolysis was found around 36 (17.1%) of the 211 surviving shells. The median annual rate of linear wear in the surviving shells was 0.12 mm/year and 0.25 mm/year in those which had been revised (p < 0.001). Polyethylene wear was a strong independent risk factor for osteolysis and aseptic loosening. The percentage of patients with osteolysis increased proportionately with each quintile of wear-rate. There is a high late rate of failure of the Plasmacup. Patients with the combination of this prosthesis and bearing should be closely monitored after ten years.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Prótese de Quadril , Adulto , Idoso , Artroplastia de Quadril/instrumentação , Cimentação , Métodos Epidemiológicos , Humanos , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia , Osteólise/diagnóstico por imagem , Osteólise/etiologia , Polietileno , Desenho de Prótese , Falha de Prótese , Radiografia , Reoperação , Resultado do Tratamento , Adulto Jovem
2.
J Bone Joint Surg Br ; 91(11): 1419-23, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19880883

RESUMO

Between 1990 and 2000, 123 hips in 110 patients were reconstructed for aseptic loosening using impaction bone grafting with frozen, irradiated, morsellised femoral heads and cemented acetabular components. This series was reported previously at a mean follow-up of five years. We have extended this follow-up and now describe the outcome of 86 hips in 74 patients at a mean of ten years. There have been 19 revisions, comprising nine for infection, seven for aseptic loosening and three for dislocation. In surviving acetabular reconstructions, union of the graft had occurred in 64 of 67 hips (95.5%). Survival analysis for all indications at ten years was 83.3% (95% confidence interval (CI) 68 to 89) and 71.3% (95% CI 58 to 84) at 15 years. Acetabular reconstruction using irradiated allograft and a cemented acetabular component is an effective method of reconstruction, providing results in the medium- to long-term comparable with those of reported series where non-irradiated freshly-frozen bone was used.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Transplante Ósseo/métodos , Cabeça do Fêmur/efeitos da radiação , Acetábulo/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Cabeça do Fêmur/transplante , Seguimentos , Sobrevivência de Enxerto , Articulação do Quadril/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Radiografia , Reoperação/métodos , Análise de Sobrevida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA