1.
Radiother Oncol ; 151: 273-279, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32798597

RESUMO

PURPOSE: To compare the dose measured by MOSkin dosimeters coupled to a trans-rectal ultrasound (TRUS) probe to the dose predicted by the brachytherapy treatment planning system (BTPS) during high dose rate (HDR) prostate brachytherapy (pBT), and to examine the feasibility of performing real-time catheter-by-catheter analysis of in-vivo rectal dosimetry during TRUS based HDR pBT. METHOD: Four MOSkin dosimeters were coupled to a TRUS probe during 20 TRUS-based HDR pBT treatment fractions. The measured MOSkin doses were retrospectively compared to those predicted by the BTPS for the total treatment fraction, as well as on a per catheter basis. RESULTS: The average relative percentage difference between MOSkin measured and BTPS predicted doses for a total treatment fraction was 0.3% ± 11.6% (k = 1), with a maximum of 23.2% and a minimum of -29.0%. The average relative percentage difference per catheter was +2.5% ± 16.9% (k = 1). The majority (64%) of per catheter MOSkin measured doses agreed with the treatment planning system within the calculated uncertainty budget of 12.3%. CONCLUSION: The results of the study agreed well with previously published data, despite differences in clinical workflows. To improve the redundancy to potential dosimeter errors, a minimum of 4 MOSkin dosimeters should be used when performing real-time in-vivo rectal dosimetry for HDR pBT, and error thresholds should be based off the total combined uncertainty estimate of measurement. 'Real time' error thresholds can be more confidently applied in the future through enhanced integration between IVD systems with both the imaging device and the BTPS/afterloader.


Assuntos
Braquiterapia , Neoplasias da Próstata , Humanos , Masculino , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Dosímetros de Radiação , Dosagem Radioterapêutica , Estudos Retrospectivos
2.
JMIR Res Protoc ; 5(2): e98, 2016 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-27296781

RESUMO

BACKGROUND: The objective of focal brachytherapy (BT) is to provide effective prostate cancer control for low-risk disease but with reduced genitourinary, gastrointestinal and sexual side effects in a cost-effective way. OBJECTIVE: The aim of this study is to describe a phase II study examining technical and dosimetric feasibility and toxicity, quality of life changes, and local control with post-treatment biopsy outcomes in men with early stage low volume prostate cancer treated with focal iodine-125 seed BT. METHODS: The study design is a prospective, multicenter trial with a planned sample size of 20 patients including men with a minimum age of 60 years, a life expectancy estimated to be greater than 10 years, with low or low-tier intermediate risk prostate cancer, unilateral disease on the biopsy, and a Gleason score of ≤3+4 and <25% cores involved. The investigations specific for the study are multi-parametric magnetic resonance imaging (Mp-MRI) baseline, at 20 and 36 months to rule out high grade disease and a transperineal mapping biopsy (baseline and at 36 months) for more accurate patient selection. The hemigland region will receive 144 Gy. Standard normal tissue constraints will be considered as for a whole gland (WG) implant. Dosimetric parameters will be evaluated at day 30 after the implant. Toxicity and quality of life will be evaluated with international validated questionnaires focusing on urinary, rectal, sexual domain, and general health-related quality of life. The patients will complete this assessment at baseline and then approximately every 6 months after the implant up to 10 years. RESULTS: To date, one patient is involved in the trial. He underwent the pre-implant investigations which found bilateral disease. Therefore, a standard seed implant was performed. If the results from this trial provide evidence that the treatment is safe, feasible, and improves toxicity, funding will be sought to conduct a large, multicenter, randomized controlled trial (RCT). CONCLUSIONS: This protocol is designed to show feasibility in delivering hemigland focal therapy with seed BT. It may answer crucial questions and obtain data which will enable downstream decisions on focal low dose rate (LDR) prostate BT. CLINICALTRIAL: Clinicaltrial.gov NCT02643511; https://www.clinicaltrials.gov/ct2/show/NCT02643511 (Archived by Webcite at http://www.webcitation.org/6ghLCzIhY).