1.
Arch Gynecol Obstet ; 299(3): 835-840, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30607596

RESUMO

PURPOSE: This article investigates the qualities and thermal effects of a novel electrosurgical device (PT) which has been designed by ERBE Elektromedizin GmbH, Germany, for the preparation of critical locations such as in skin-sparing or nipple-sparing techniques and compares it to a standard device (SD) in a porcine ex vivo breast model using an heat map generated by infrared thermography. METHODS: In total, 42 abdominal wall specimens of porcine tissue consisting of the skin and the underlying subcutaneous and muscle layer were alternately dissected using one of the devices and pre-settings. During the preparation with the two devices, the epicutaneous temperature was measured by an infrared camera (VarioCam, Jenoptik, Germany) and the maximum temperature as well as the slope of the temperature rise was analysed. RESULTS: The use of PT shows significantly lower values for [Formula: see text] compared to SD. This effect was independent from the chosen mode. Using the same instrument in different modes, the use of AutoCut mode showed a significant reduction of [Formula: see text] at all indicated time points (SD: p < 0.0001 and PT: p < 0.0001). In summary, the combination of AutoCut + PT showed the lowest rise in temperature, whereas the combination of DryCut + SD led to the highest rise in temperature. The temperature difference between these two settings was 13.84 °C, which means a possible temperature reduction of 67% can be achieved by the right choice of device and its tailored mode. CONCLUSIONS: The novel PT shows a significant reduction in epicutaneous temperature and a significant reduction of the slope of temperature rise most probably by a more focused application of energy compared to SD.


Assuntos
Mama/cirurgia , Eletrocirurgia/métodos , Termografia/métodos , Animais , Mama/patologia , Modelos Animais de Doenças , Feminino , Suínos
2.
Rofo ; 186(10): 945-50, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24691837

RESUMO

PURPOSE: Energy transfer from radiofrequency (RF) applicator to tissue is both precondition and limiting factor. The purpose of this ex vivo study was to examine the influence of form of energy delivery on ablation result during RF ablation with cryo-cooled applicators. MATERIALS AND METHODS: One hundred eight ablations were performed in ex vivo bovine liver under continuous energy delivery (A), pulsed energy delivery with reduced current during ablation pause (B) and impedance-dependent energy delivery. Maximum ablation time was 20 min. Early termination of ablation in case of loss of conductivity. Optimal ablation parameters were assessed. Short axis diameter of the ablation zone and ablation duration were determined. Ablation results under mode A, B and C were compared with analysis of variance and Tukey-Kramer HSD test. Influence of ablation duration on short axis diameter was evaluated with regression analysis. RESULTS: Significantly largest short axis diameter (51.1 mm ± SD 2.3; p = 0.01) was reached with impedance-dependent energy delivery (pulsed: 46.1 mm ± SD 5.6; continuous: 44.4 mm ± SD 4.1). Significantly longest ablation duration (1061.6 s ± SD 42.4; p = 0.01) was reached with impedance-dependent energy delivery (pulsed: 815.7 s ±â€Š41.3; continuous: 715.3 s ± SD 82.2). Linear correlation between ablation duration and short axis diameter was calculated (R = 0.7). CONCLUSION: Modification of energy delivery during RF ablation with cryo-cooled applicators improves energy transfer to tissue and enables larger ablation zones. KEY POINTS: • Impedance-dependent energy delivery prevents early termination in kryo-based RF-ablation,• Impedance-dependent energy delivery enables larger ablation zones than continuous energy delivery,• Reduced current during ablation pause does not improve ablation results.


Assuntos
Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Criocirurgia/instrumentação , Criocirurgia/métodos , Transferência Linear de Energia , Fígado/cirurgia , Animais , Bovinos , Desenho de Equipamento , Técnicas In Vitro , Fígado/patologia
3.
Surg Endosc ; 26(2): 343-9, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21993928

RESUMO

BACKGROUND: Endoscopic mucosal resection (EMR) and endoscopic submucosal dissection of large lateral spreading tumors currently are technically limited by complications such as bleeding, perforation, and disturbed large procedural sites, leading to incomplete resection and secondary surgery. Further technical improvements are necessary. The authors previously demonstrated the effectiveness of a focused water jet for elevation of the lamina submucosa in animal studies. For the first time, the clinical application of selective tissue elevation by pressure (STEP) for the treatment of colorectal adenomas as a prospective single-arm human trial is presented. METHODS: This trial evaluated 59 patients who had primary colorectal adenomas with diameters exceeding 12 mm classified as 0-IIa or 0-IIb according to Paris classification. A submucosal cushion was created with a flexible water jet applicator using the Helix HydroJet. The adenoma was subsequently resected with a mucosal resection snare. All results were recorded. The resected specimens were assessed histologically. RESULTS: A total of 59 patients underwent resection of 70 lesions with a maximum diameter of 80 mm (mean, 27 mm). Submucosal elevation with the water jet dissector was possible in all cases and locations from the pectinate line to the ileocecal valve. Of the 70 lesions, 64 (91%) were resected completely in one session. Histologically, the resected specimens were found to be adenocarcinomas (n = 2, 3%), adenomas with high-grade intraepithelial neoplasia (n = 24, 34%), adenomas with low-grade intraepithelial neoplasia (n = 38, 54%), and hyperplastic polyps (n = 6, 9%). Hemostasis during the resection was necessary in 24 cases (34%). No perforation required surgical intervention. CONCLUSION: This first clinical trial to analyze STEP technique demonstrated that STEP used to elevate large mucosal lesions in any location is feasible and facilitates EMR for colorectal adenoma.


Assuntos
Adenoma/cirurgia , Neoplasias Colorretais/cirurgia , Endoscopia Gastrointestinal/métodos , Idoso , Estudos de Viabilidade , Feminino , Humanos , Injeções a Jato , Mucosa Intestinal/cirurgia , Masculino , Pressão , Estudos Prospectivos , Água
4.
Z Gastroenterol ; 49(2): 195-200, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21298605

RESUMO

BACKGROUND: APC is a thermal coagulation technique that uses ionized argon to transmit high-frequency electrical current, contact-free, to tissue. Precise APC is one of the new modes and is characterized by a small and distinctive energy input, higher reproducibility of tissue effects which is almost independent of the probe distance. The aim of the study was the evaluation of precise APC in patients with bleeding angiodysplasia's in the cecum or the small bowel. AIM/METHODS: Patients (pts.) with bleeding angiodysplasia of the cecum or small bowel were prospectively enrolled. Effectivity and safety of APC was assessed by evaluating the local coagulation effect, number of rebleedings and transfusions and complications (perforation, infection). RESULTS: There were 50 males and 44 females, median age 65.5 ± 8.5 years. 58 pts. (62 %) had lesions in the small bowel, 28 pts. (30 %) lesions in the cecum and 8 pts. (8 %) lesions in small bowel and cecum. All 234 visible lesions in 94 pts. were coagulated successfully. There was no perforation, active bleeding and tissue carbonization after the procedure. Re-bleeding was recognized in 18 pts. (19 %) after a mean follow-up of 6.1 months and new lesions in the same area were seen in 15 / 18 pts (16 %). CONCLUSION: In a historical comparison to forced or pulsed APC, precise APC may be a more appropriate option for the treatment of bleeding angiodysplasia's in critical locations like the cecum or small bowel. The coagulation effect seems to be comparable and due to its better depth control we assume a better safety, especially in preventing perforations.


Assuntos
Angiodisplasia/complicações , Angiodisplasia/terapia , Coagulação com Plasma de Argônio/métodos , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Coagulação com Plasma de Argônio/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
5.
Endoscopy ; 41(8): 702-6, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19670138

RESUMO

BACKGROUND AND STUDY AIM: Choledocholithiasis is a common disease in the West. Lithotripsy by mechanical methods using baskets and by laser or electrohydraulic methods varies in effectiveness. With argon plasma coagulation (APC), high temperatures are used for devitalization and fragmentation; cryogenic techniques use the selective controlled application of freeze-thaw cycles to devitalize pathological tissue; and the dissecting water jet exploits the high pressure action of a thin laminar jet. We aimed to assess the feasibility and effectiveness of APC, cryotechnology, and the dissecting water jet as options for the fragmentation of bile duct stones. METHODS: In an in vitro feasibility study, we evaluated the fragmentation of 120 bile duct stones treated with the three methods. Primary measures were assessment of the fragmentation rate, fragmentation effect, and energy application for each technology. RESULTS: Fragmentation was seen in only 10 % of stones treated cryogenically using liquid nitrogen. APC at a power setting of 30 - 50 W fragmented all the cholesterol stones, but results with hard pigment stones were unsatisfactory even at high energies of a 100 W setting and long application time. Using the water jet, all 40 stones (100 %) were cracked effectively and completely with a pressure of 10 - 50 bar. CONCLUSION: In this feasibility study, the first of its kind, only the water-jet device demonstrated efficient fragmentation of large bile duct stones in vitro. APC and cryotechnology are not suitable for the treatment of bile duct stones; the fragmentation rate with these methods was inadequate.


Assuntos
Coledocolitíase/terapia , Criocirurgia , Eletrocoagulação , Cálculos Biliares/terapia , Litotripsia/métodos , Argônio , Criocirurgia/métodos , Eletrocoagulação/métodos , Estudos de Viabilidade , Humanos , Técnicas In Vitro , Pressão , Água/administração & dosagem
6.
Endoscopy ; 41(4): 340-5, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19340739

RESUMO

BACKGROUND AND STUDY AIMS: Endoscopic submucosal dissection (ESD) is a promising therapeutic technique for en bloc resection of large gastrointestinal tumors. However, this technique has disadvantages such as a long intervention time, complexity of the procedure, and a higher rate of complications. The primary aims of the study were to show the feasibility of ESD in the pig colon and to evaluate a new ESD technique comprising the use of a newly developed hybrid knife for colon procedures combining RF (radiofrequency) application and a distance-dependent water-jet application. MATERIALS AND METHODS: ESD was conducted at three different locations in the colon according to the computer-generated randomization list, using either the standard technique (injection needle, flex knife, and hook knife as therapeutic instruments and DRY CUT and SWIFT COAG as RF currents), or the new ESD technique (hybrid knife as the therapeutic instrument combined with the new cutting mode ENDO CUT D) in 12 healthy pigs. The perforation and bleeding rates were documented and statistically analyzed. Intervention time, resected specimen size, thermal and mechanical damage of the resection bed, and number of instrument changes required were also recorded. RESULTS: A total of 16 and 18 ESD procedures were performed by the standard and new techniques, respectively. Complete en bloc resection was achieved in all cases. The standard ESD technique showed a perforation rate of 25 % (4/16) whereas the new ESD technique resulted in a 5.5 % perforation rate (1/18) ( P = 0.035); bleeding rates were similar. The new ESD technique was significantly safer compared with the standard ESD technique. CONCLUSIONS: A new ESD technique for the successful en bloc resection in thin-walled regions such as pig colon has been described. This procedure is as effective as the standard procedure but is easier to handle and significantly safer.


Assuntos
Ablação por Cateter/métodos , Colo/cirurgia , Gastroscopia/métodos , Mucosa Intestinal/cirurgia , Animais , Queimaduras/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Colo/lesões , Estudos de Viabilidade , Gastroscopia/efeitos adversos , Perfuração Intestinal/etiologia , Estudos Prospectivos , Distribuição Aleatória , Suínos
7.
Endoscopy ; 40(9): 759-63, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18702032

RESUMO

BACKGROUND AND STUDY AIMS: In a previous study, a new flexible bipolar hybrid cryotherm probe was applied with success to the pancreas of a living pig. Here we evaluated feasibility, efficacy, and safety of its application to the porcine liver and spleen. MATERIAL AND METHODS: Ten applications to the liver and nine to the spleen were performed in 19 pigs. Power input (16-18 W) and simultaneous cooling with CO(2) (standardized pressure: 675 psi) as the cryogenic agent were investigated. Application time varied from 120 seconds to 900 seconds. The ablation area was measured by endoscopic ultrasound (EUS) after ablation (T0), and before euthanasia (T1). Gross pathology (T2) and histology after necropsy represented the gold standard. The interval from treatment to euthanasia was 1 or 2 weeks. RESULTS: For both organs the correlation between EUS and gross pathology was good (correlation coefficient R(liver) = 0.71; R(spleen) = 0.73). EUS tended to overestimate the area of the ablated zone. EUS observed a time-dependent ablation area: we demonstrated a positive trend of lesion size (T1) over time in liver tissue (R = 0.51 (P = 0.1)). In the spleen we found a clear correlation of lesion area T2 and application time (R = 0.75, P = 0.01). There were no complications. CONCLUSIONS: Selective EUS-guided transgastric cryotherm ablation of the liver and spleen in a pig model is feasible and safe. The new bipolar probe creates a time-dependent ablation area without any complications, and opens a field of new potential indications of RF-ablative therapies.


Assuntos
Ablação por Cateter/instrumentação , Criocirurgia/instrumentação , Endoscopia/métodos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Baço/diagnóstico por imagem , Baço/cirurgia , Animais , Desenho de Equipamento , Estudos de Viabilidade , Fígado/patologia , Modelos Animais , Baço/patologia , Suínos , Ultrassonografia
8.
Endoscopy ; 40(4): 321-6, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18389449

RESUMO

BACKGROUND AND STUDY AIMS: Open, laparoscopic, or percutaneous radiofrequency (RF) ablation of the pancreas is still dangerous, whereas endoscopic ultrasound (EUS)-guided ablation might reduce risk because it is less invasive and provides real-time monitoring. We aimed to demonstrate the feasibility of transluminal RF ablation and to evaluate the efficacy and safety of a new flexible bipolar ablation probe combining RF and cryotechnology. METHODS: 14 ablations were performed in 14 pigs. Energy input (16 W) and simultaneous cryogenic cooling with carbon dioxide (650 psi) were standardized. Application time range was 120 - 900 seconds. Ablation area was measured by EUS immediately after ablation (area T0), and before euthanasia (area T1). Macroscopic findings (area T2) and histological findings after necropsy served as gold standard. The interval from application to euthanasia was either 1 or 2 weeks. RESULTS: The correlation between EUS findings (area T1) and macroscopic appearance (area T2) was good ( R = 0.89). The correlation between the T2 ablation area and the application time showed a fitted ratio of 2.3 ( P < 0.0001) with a 1-week interval and 0.2 ( P = 0.01) with a 2-week interval. No pig died because of the procedure. Two pigs showed histochemical pancreatitis, which was clinically overt in one. Necropsy additionally revealed one burn to the gastric wall and four gut adhesions. CONCLUSIONS: Selective transluminal RF ablation of the pancreas under EUS control in a living pig model is feasible. The new flexible bipolar probe creates an ablation area with extent related to the duration of application, and with fewer complications than conventional RF ablation techniques.


Assuntos
Ablação por Cateter/instrumentação , Criocirurgia/instrumentação , Pâncreas/diagnóstico por imagem , Pâncreas/cirurgia , Animais , Projetos Piloto , Complicações Pós-Operatórias , Análise de Regressão , Estatísticas não Paramétricas , Suínos , Ultrassonografia
9.
Surg Endosc ; 22(2): 443-7, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17593436

RESUMO

BACKGROUND: Several new techniques have recently been described that allow the endoscopic mucosal resection even of broad-based flat lesions in the gastrointestinal tract. The technique recently described by us of using a water jet dissector (Helix HydroJet) for a selective deposition of liquid in the submucosal lamina has now been combined with different substances, and their effects have been compared. MATERIAL AND METHODS: Gastroscopies were carried out in 8 pigs under intubation anesthesia, and 2 submucosal cushions each were created in the stomach using one out of 4 test substances (gelatin, glucose 50, hydroxyethyl starch [HES] 10%, dextran 40), as well as one cushion of isotonic saline solution placed in each area via the Helix HydroJet). The height of the submucosal cushions was intermittently measured over a period of 40 or 20 min, respectively, by miniprobe endosonography. In 7 of the animals the stomach was subsequently subjected to mucosal resection. The specimens and the gastric wall were histologically assessed to evaluate the localization of the liquid cushion and the effect on adjacent layers of the gastric wall. RESULTS: All test substances produced strictly selective liquid cushions in the submucosa. With HES 10% and dextran the maximum height of the cushions initially increased and then decreased during the further course to an average of 90% of the initial height within 40 min. Isotonic saline solution showed the most rapid decrease in height (72% after 20 min). The histological assessment confirmed the selective nature of the liquid deposit in the submucosa. DISCUSSION: Plasma expanders produced cushions that initially increased in height but then remained constant for a longer period than cushions produced using glucose 50, gelatin, or isotonic saline solution. The combination of transmucosal jet application for elevation of the mucosa with plasma expanders is therefore an interesting approach to optimize endoscopic mucosal resections.


Assuntos
Dextranos , Mucosa Gástrica/cirurgia , Gastroscopia , Gelatina , Glucose , Derivados de Hidroxietil Amido , Cuidados Pré-Operatórios/métodos , Animais , Suínos
10.
Surg Endosc ; 22(7): 1701-7, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18071803

RESUMO

BACKGROUND: Argon plasma coagulation (APC) is a thermal coagulation technique that uses ionized argon for contact-free transmission of high-frequency electrical current to tissue. Prospective data on complications with the new APC-2 (VIO) system are lacking. METHODS: A prospective trial was conducted with 152 patients treated for various gastrointestinal diseases using three modes of the APC-2. The study aimed to assess complications, focusing on the pain and neuromuscular stimulation (NMS) experienced during and after treatment. Patients reported pain and NMS using a scale ranging from 0 to 10 and were interviewed for symptoms such as tingling, paresthesia, muscle pain, and cramping or twitching. The endoscopists also graded NMS using a separate questionnaire. RESULTS: A total of 85 males and 67 females (median age, 66 years) were enrolled in the study. All APC therapies were completed successfully. Two peri-interventional perforations were recorded. Of the 152 patients, 26 (17%) reported pain sensation during or after APC. The median pain sensation reported by the patients on the standardized scale was 3.7. The findings showed NMS in 14 (9.2%) of the 152 patients. Significantly more NMS events were seen with pulsed APC than with forced or precise APC. Additional risk factors for NMS were gender (female) and type of sedation (combination midazolam and pethidine). No complications were noted among patients with intracardiac defibrillators or cardiac pacemakers. CONCLUSIONS: According to the findings, APC may be associated with minor complications such as pain sensation and NMS. These complications were rarely seen, but occurred more often with pulsed APC than with forced or precise APC. Physicians should be aware of these complications.


Assuntos
Estimulação Elétrica/métodos , Eletrocoagulação/métodos , Endoscopia Gastrointestinal/métodos , Gastroenteropatias/terapia , Dor/prevenção & controle , Idoso , Eletrocoagulação/efeitos adversos , Endoscopia Gastrointestinal/efeitos adversos , Feminino , Humanos , Lasers de Gás/efeitos adversos , Lasers de Gás/uso terapêutico , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Dor/etiologia , Medição da Dor
11.
Endoscopy ; 39(7): 637-42, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17611919

RESUMO

BACKGROUND AND STUDY AIM: Argon plasma coagulation (APC) has become an established noncontact method of tumor palliation in a variety of locations. The present prospective study evaluated a new APC system (APC-2) using amplified power settings and different application modes, such as intermittent energy delivery (pulsed APC) in comparison with the conventional technique (forced APC). PATIENTS AND METHODS: A total of 100 patients with esophageal, gastric, or rectal tumors were alternately (but not randomized) enrolled and treated with either pulsed APC (n = 46) or forced APC (n = 54). Parameters to assess the palliative effect were: amount of lumen restoration ((1/3), (2/3), complete), objective planimetry, stenosis length, treatment time, and number of APC sessions. RESULTS: Overall response rate was similar in both groups (pulsed 83 %, forced 87 %), the same was found in the subgroups with different amounts of lumen restoration and for the other objective parameters. However, the tumor debulking effect was achieved in a significantly shorter median treatment time with forced compared with pulsed APC (13.6 vs. 18.2 minutes, P = 0.03), with a similar number of treatment sessions in both groups. Complications also occurred with similar frequency in both groups. CONCLUSIONS: There was no significant difference in overall local tumor response between the two modes of APC application. However, data from this nonrandomized study suggest a faster achievement of response with forced APC. A combination of both modes may be superior.


Assuntos
Endoscopia Gastrointestinal/métodos , Estenose Esofágica/cirurgia , Obstrução da Saída Gástrica/cirurgia , Obstrução Intestinal/cirurgia , Fotocoagulação a Laser/instrumentação , Cuidados Paliativos/métodos , Idoso , Desenho de Equipamento , Neoplasias Esofágicas/complicações , Neoplasias Esofágicas/cirurgia , Estenose Esofágica/etiologia , Feminino , Seguimentos , Obstrução da Saída Gástrica/etiologia , Humanos , Obstrução Intestinal/etiologia , Masculino , Estudos Prospectivos , Neoplasias Retais/complicações , Neoplasias Retais/cirurgia , Neoplasias Gástricas/complicações , Neoplasias Gástricas/cirurgia , Resultado do Tratamento
12.
Ann Oncol ; 15(4): 661-4, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15033676

RESUMO

BACKGROUND: From 2% to 10% of cancer patients treated with 5-fluorouracil (5-FU) will develop symptomatic cardiotoxicity. Nevertheless, the underlying pathophysiology is mostly unknown. PATIENTS AND METHODS: We investigated the influence of intravenous chemotherapy (CTX) on the diameter of the brachial artery using high resolution ultrasound in patients with malignant tumors, mostly gastrointestinal cancer. Cytostatic drugs included 30 cases with 5-FU and 30 cases with non-5-FU CTX (cis/carboplatin, anthracycline and cyclophosphamide). In addition, plasma levels of big endothelin were assessed prior to and after CTX. RESULTS: Fifteen of 30 patients (50%) showed a contraction of the brachial artery after the end of 5-FU application (median 11%, range 4.3-18.5), whereas no single contraction was noticed in 30 patients following non-5-FU-based CTX. Vessel tonus generally normalized within 30 min after stopping 5-FU. Five patients positive for 5-FU associated vessel contraction were repeatedly exposed to 5-FU. Vessel contractions reoccurred in 86% (18/21) of these administrations. When patients with 5-FU bolus application were pre-treated with glyceroltrinitrate no contraction of the brachial artery was detected in five out of five occasions. There was a trend towards increased big endothelin plasma levels after 5-FU application (median 1.52 versus 1.99 fmol/ml; P = 0.07), whereas big endothelin levels remained unchanged after non-5-FU CTX (1.83 versus 1.83 fmol/ml; P = 0.99). CONCLUSIONS: Application of 5-FU is commonly accompanied by arterial vessel contractions, which is likely to represent the first step in 5-FU-induced cardiotoxicity. 5-FU-associated vessel contractions were highly reproducible on re-exposure and were in the case of bolus application completely preventable by glyceroltrinitrate.


Assuntos
Artéria Braquial/efeitos dos fármacos , Fluoruracila/efeitos adversos , Neoplasias/tratamento farmacológico , Vasoconstrição/efeitos dos fármacos , Adulto , Idoso , Idoso de 80 Anos ou mais , Antimetabólitos Antineoplásicos/efeitos adversos , Antimetabólitos Antineoplásicos/uso terapêutico , Artéria Braquial/fisiopatologia , Endotelinas/sangue , Fluoruracila/uso terapêutico , Neoplasias Gastrointestinais/tratamento farmacológico , Humanos , Neoplasias Pulmonares/tratamento farmacológico , Pessoa de Meia-Idade , Estudos Prospectivos
13.
Biomed Tech (Berl) ; 48(5): 141-6, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12838797

RESUMO

Transcutaneous vessel imaging is a frequently used ultrasound imaging modality in medicine. The measurement of vessel diameters can be done with conventional B-mode imaging systems, which work at frame rates up to 100 Hz. Furthermore, there are special systems available, which can track vessel walls very precisely using the phase of signals that are sent at frame rates up to several thousand Hz. Though, such systems are usually not able to provide the examiner with 2D images of the object. With respect to brachial artery flow-mediated vasodilatation (FMD), which is frequently used as a measure of endothelial function, it is necessary to observe diameter changes of small arterial vessels noninvasively for several minutes at a high resolution. In the past, the diameter had to be measured manually in tedious postprocessing of ECG-gated image sequences. We developed a system composed of a Siemens Omnia ultrasound system with a VF13-5 transducer (9 MHz center frequency) and a personal computer, that is capable of calculating vessel diameter changes with an accuracy below the wavelength of the ultrasound system in real-time at a frame rate of 27 Hz. We implemented a two-dimensional active contour model using the Viter-bi-algorithm and a phase-sensitive vessel wall tracking algorithm, in order to guarantee both, geometric information and accuracy. Results from carotid and brachial arteries show that arterial pulsations below 0.1 mm can be visualized reliably over several minutes. With this system we want to find out, if FMD is suitable for an individual assessment of the risk for cardiovascular diseases.


Assuntos
Interpretação de Imagem Assistida por Computador/instrumentação , Computação Matemática , Microcomputadores , Pele/irrigação sanguínea , Transdutores , Ultrassonografia/instrumentação , Resistência Vascular/fisiologia , Algoritmos , Artéria Braquial/diagnóstico por imagem , Desenho de Equipamento , Humanos , Reprodutibilidade dos Testes , Vasodilatação/fisiologia
14.
Exp Clin Endocrinol Diabetes ; 109(3): 141-5, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11409295

RESUMO

Paraoxonase 1 (PON1) is an HDL-associated enzyme which protects HDL and LDL particles from lipid peroxidation. Its enzymatic serum activity varies 10-40-fold between individuals, and its biallelic gene polymorphism at codon 192 (glutamine-->arginine, Gln/Arg) has been associated with coronary artery disease in diabetic patients. To evaluate the role of this PON1 gene polymorphism in cerebrovascular disease, we determined the PON1 192 genotype in 149 patients with hemodynamically relevant extracranial artery stenosis and in 241 controls. The PON1 192 Gln/Arg genotype was determined using polymerase chain reaction followed by Alw I digestion and polyacrylamide gel electrophoresis. Among all subjects, there was no association between the PON1 192 Gln/Arg genotype and cerebrovascular disease (Odds ratio for Arg/Arg and Gln/Arg vs Gln/Gln 0.99, 95%-CI 0.70-1.39). In contrast, in the subgroup of type 2 diabetic patients the PON1 192 Arg allele conferred about twice the risk of cerebrovascular stenosis compared to those homozygous for the Gln allele (Odds ratio 2.00, 95%-CI 0.92-4.38). Our data indicate that in the general population the PON1 192 Gln/Arg gene polymorphism cannot be regarded as a major risk marker for cerebrovascular disease. The observed interaction with type 2 diabetes, however, is supporting the hypothesis that the effect of the PON1 192 Arg allele on atherosclerosis is modulated by other risk factors like diabetes.


Assuntos
Arginina , Transtornos Cerebrovasculares/genética , Diabetes Mellitus Tipo 2/genética , Esterases/genética , Glutamina , Polimorfismo Genético , Idoso , Alelos , Arildialquilfosfatase , Transtornos Cerebrovasculares/enzimologia , Diabetes Mellitus Tipo 2/enzimologia , Feminino , Predisposição Genética para Doença , Genótipo , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Fumar
15.
Int J Cardiol ; 76(2-3): 219-25, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11104877

RESUMO

BACKGROUND: The non-invasive determination of the endothelial dysfunction (ED) of the brachial artery is a widely used method in clinical research. It remained, however, unclear, whether the test-results are influenced by the anatomical vessel size, the patients age, body mass index (BMI) or gender. METHODS: The flow-mediated vasodilatation (FMD%) of the brachial artery was determined in 122 consecutive (88 male, 34 female) patients. FMD% was measured using high resolution ultrasound (13 Mhz) at rest, during reactive hyperaemia and after the sublingual administration of glycerolnitrate (GTN%). RESULTS: Lumen diameters at rest varied from 2.48 mm to 6.33 mm (4.46+/-0.74 mm). The extent of FMD% as well as of GTN% showed an inverse correlation to the resting lumen diameters (r=-0.33, P<0.001/r=-0.51, P<0.001). This correlation was even more distinct in females (females: FMD% r=-0.54, P<0.001; GTN% r=-0.64, P<0.001 vs. males: FMD% -0.23, P<0.001; GTN% -0.59, P<0. 001). No significant influence of age (61+/-9 years, FMD%: r=-0.04, P=0.68, GTN%: r=-0.18, P=0.05) and BMI (27.03+/-3.43 kg/m(2), FMD%: r=0.16, P=0.08, GTN%: r=0.09, P=0.3) on the test results were found. CONCLUSIONS: FMD% was found to be rather independent of age or BMI. The anatomical vessel size had an influence on the test results, which was more obvious in female patients. Our data indicate the necessity of further methodological studies, in larger, community-based populations. In particular, it needs to be clarified, whether vessel size or even gender-specific correction factors are required when using this technique in routine clinical practice.


Assuntos
Artéria Braquial/fisiopatologia , Adulto , Fatores Etários , Idoso , Velocidade do Fluxo Sanguíneo , Índice de Massa Corporal , Artéria Braquial/diagnóstico por imagem , Artéria Braquial/efeitos dos fármacos , Distribuição de Qui-Quadrado , Doença das Coronárias/fisiopatologia , Endotélio Vascular/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Análise de Regressão , Fatores Sexuais , Estatísticas não Paramétricas , Ultrassonografia , Vasodilatação/efeitos dos fármacos , Vasodilatação/fisiologia
16.
Haemostasis ; 30(3): 149-58, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11014965

RESUMO

OBJECTIVE: To asses endothelial function and variables of fibrinolysis and coagulation in smokers compared to healthy controls. METHODS: Flow-associated dilation as a marker for peripheral endothelial function and intima media thickness as a marker for early morphologic vascular changes were measured in otherwise healthy smokers (n = 30, 16 males and 14 females, age: 40.6 +/- 11.3 years, body mass index 24.9 +/- 3.7 kg/m(2)) and non-smoking controls matched for age and sex using high-resolution ultrasound. Variables of the coagulation system (thrombin-antithrombin III complex, fibrinogen) and fibrinolysis (tissue-plasminogen activator, plasmin-alpha(2)-antiplasmin complex) were determined by ELISA and plasminogen activator inhibitor activity by means of a chromogenic substrate test. RESULTS: Compared to the non-smoking controls, flow-associated vasodilatation was significantly reduced (6.9 +/- 4. 4 vs. 10.5 +/- 6.2%, p = 0.01) and intima media thickness tended to be increased (0.58 +/- 0.12 vs. 0.52 +/- 0.14 mm, p = 0.08) in smokers. The thrombin-antithrombin III complex, fibrinogen, plasmin-alpha(2)-antiplasmin complex, tissue-plasminogen activator and plasminogen activator inhibitor activity did not differ between smokers and controls. CONCLUSION: Our data indicate that peripheral endothelial dysfunction is common in smokers even without major alterations in molecular markers of the coagulation and fibrinolysis system.


Assuntos
Endotélio Vascular/fisiopatologia , Fumar/patologia , Fumar/fisiopatologia , Adulto , Biomarcadores/sangue , Fatores de Coagulação Sanguínea/metabolismo , Velocidade do Fluxo Sanguíneo , Artéria Braquial/fisiopatologia , Artérias Carótidas/fisiopatologia , Feminino , Fibrinolíticos/sangue , Hemostasia , Humanos , Masculino , Análise por Pareamento , Pessoa de Meia-Idade , Fumar/efeitos adversos , Túnica Íntima/patologia , Túnica Média/patologia , Vasodilatação
17.
Exp Clin Endocrinol Diabetes ; 108(5): 382-5, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-10989959

RESUMO

Chronic estrogen supplementation is known to improve endothelial function in postmenopausal women. We studied the acute effect of a single dose of orally administered 17beta-estradiol valerate (E2) on the peripheral endothelial dependent and independent vasodilatation in postmenopausal women with coronary artery disease (CAD). 20 postmenopausal women (age: 64.9 (7.2) y, height: 1.61 (0.04) m. weight: 68.6 (10.6) kg) with angiographically confirmed CAD were randomly examined for flow-associated vasodilatation (= FAD%, a marker for endothelial dependent vasodilatation) and for glyceryltrinitrate (400 microg, p.o.) induced vasodilatation (= GTN%, representing endothelial independent vasodilatation) two hours after placebo controlled, randomized crossover intake of 4 mg E2 p.o. After placebo FAD% was impaired (3.5 (1.7)%) compared to historic controls. After the oral intake of 4 mg E2, FAD% improved to 5.0 (2.8)% (P=0.02). GTN% was not significantly influenced by the oral E2 (E2: 12.6 (5.7) v placebo: 11.2 (6.9)%, P=0.14). Endothelial dysfunction can partially be restored by a single oral dose of 4 mg E2. This indicates an acute vasoprotective effect of E2 beyond its genomic and lipid modifying actions. It remains to be investigated if estrogen might play a beneficial role in the acute treatment of symptomatic coronary artery disease such as angina pectoris or preinfarct syndrome.


Assuntos
Doença das Coronárias/tratamento farmacológico , Endotélio Vascular/fisiopatologia , Estradiol/análogos & derivados , Estrogênios Conjugados (USP)/uso terapêutico , Pós-Menopausa/fisiologia , Idoso , Pressão Sanguínea/fisiologia , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/fisiopatologia , Endotélio Vascular/diagnóstico por imagem , Estradiol/uso terapêutico , Feminino , Humanos , Pessoa de Meia-Idade , Pós-Menopausa/efeitos dos fármacos , Ultrassonografia , Vasodilatação/efeitos dos fármacos , Vasodilatação/fisiologia
18.
Circulation ; 101(15): 1780-4, 2000 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-10769277

RESUMO

BACKGROUND: Endothelial dysfunction (ED) is regarded as an early step in the development of atherosclerosis. Among the pathogenetic factors leading to atherosclerosis, the role of insulin resistance and hyperinsulinemia as independent risk factors is still under debate. In this study, we examined the association between ED and insulin resistance in normotensive and normoglycemic first-degree relatives (FDRs) of patients with type 2 diabetes mellitus (DM). METHODS AND RESULTS: Endothelium-dependent and -independent vasodilation of the brachial artery was measured with high-resolution ultrasound (13 MHz) in 53 normotensive FDRs (21 men, 32 women; mean age, 35 years) with normal oral glucose tolerance, 10 age- and sex-matched normal control subjects, and 25 DM patients (mean age, 57 years). According to the tertiles of the clamp-derived glucose metabolic clearance rate (MCR), the FDRs were further classified as insulin resistant with an MCR or =7.8 mL. kg(-1). min(-1), and borderline with an MCR of 5.9 to 7.7 mL. kg(-1). min(-1). Flow-associated dilation was 4.1+/-0.9% in insulin-resistant FDRs, 6.7+/-1.1% in borderline FDRs, 9.0+/-1.2% in insulin-sensitive FDRs (P=0.002), 7.7+/-2.9% in control subjects (P=NS versus FDRs), and 3.8+/-1.0% in DM patients (P=0.03). In multiple regression analysis, low MCR was significantly correlated with ED independent of age, sex, smoking, body mass index, percent body fat, serum insulin, and lipids. CONCLUSIONS: There is a significant association between ED and insulin resistance in young FDRs of DM subjects independent of the classic cardiovascular risk factors.


Assuntos
Diabetes Mellitus Tipo 2/genética , Diabetes Mellitus Tipo 2/fisiopatologia , Endotélio Vascular/fisiopatologia , Resistência à Insulina/fisiologia , Adolescente , Adulto , Idoso , Pressão Sanguínea/fisiologia , Estudos de Casos e Controles , Distribuição de Qui-Quadrado , Diabetes Mellitus/fisiopatologia , Feminino , Técnica Clamp de Glucose , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Fatores de Risco , Estatísticas não Paramétricas , Vasodilatação
19.
Am Heart J ; 138(4 Pt 1): 731-9, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10502220

RESUMO

BACKGROUND: Peripheral endothelial dysfunction (ED) quantified by the determination of flow-mediated dilation (FMD%) of the brachial artery with the use of high-resolution ultrasound is an early marker of atherosclerosis. Although a positive correlation with coronary artery disease (CAD) has been reported, the unanswered clinical question is the validity of FMD% as a screening test in patients with clinical suspicion of CAD. Thus the aim of this study was to determine the predictive value of FMD% compared with angina pectoris, exercise electrocardiography, and myocardial perfusion imaging. METHODS AND RESULTS: In this pilot study, we measured ED in 122 patients scheduled for coronary angiography by using high-resolution ultrasound (13 MHz). We defined ED as FMD%

Assuntos
Doença das Coronárias/diagnóstico , Endotélio Vascular/fisiologia , Vasodilatação/fisiologia , Angina Pectoris/diagnóstico , Artéria Braquial/diagnóstico por imagem , Doença das Coronárias/epidemiologia , Eletrocardiografia , Teste de Esforço , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Programas de Rastreamento , Pessoa de Meia-Idade , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Cintilografia , Sensibilidade e Especificidade , Ultrassonografia/métodos
20.
Dtsch Med Wochenschr ; 124(30): 886-90, 1999 Jul 30.
Artigo em Alemão | MEDLINE | ID: mdl-10464489

RESUMO

BACKGROUND AND OBJECTIVE: A positive correlation between the presence of coronary artery disease (CAD) and peripheral endothelial dysfunction (ED) of the brachial artery has been shown in several studies. Aim of the present study was to evaluate whether the non-invasive determination of ED could also be used as a screening test in patients suspected of having CAD. PATIENTS AND METHODS: 122 patients were included. 112 had an exercise-ECG before hospital admission. Preceding coronary angiography, FMD% was measured by high-resolution ultrasound (13 Mhz). Longitudinal scans of the brachial artery were done at rest, during reactive hyperemia and after the sublingual administration of nitroglycerin. RESULTS: In 101 of the 122 patients the presence of CAD was diagnosed by angiography, whereas 21 patients had normal coronary arteries. The extent of the vasodilation (FMD%) was found to be largely independent of the resting vessel diameters (FMD%/vessel diameter at rest: r = -0.32767 p = 0.0002). FMD% was significantly higher in patient without CAD than in the CAD group (7.01 +/- 3.5% vs. 3.73 +/- 4.11%, p < 0.001). Comparison of sensitivity and specificity to predict the presence of CAD between FMD% [sensitivity 71.3%, specificity 81%] and exercise-ECG [sensitivity 82.4%, specificity 57.1%] gave similar results. No correlation was found between the degree of the impairment of FMD% and the severely of CAD. CONCLUSION: The determination of peripheral ED was found to be a sensitive and specific measure for predicting the presence of CAD in our cohort. Since this approach is non-invasive, non-radioactive and cost-effective it warrants further evaluation of its role as an additional screening test in patients clinically suspected of having CAD.


Assuntos
Artéria Braquial/diagnóstico por imagem , Doença das Coronárias/diagnóstico por imagem , Endotélio Vascular/diagnóstico por imagem , Idoso , Artéria Braquial/fisiopatologia , Angiografia Coronária , Doença das Coronárias/fisiopatologia , Endotélio Vascular/fisiopatologia , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Sensibilidade e Especificidade , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Ultrassonografia/estatística & dados numéricos , Vasodilatação