Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Am J Emerg Med ; 33(3): 396-401, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25612468

RESUMO

STUDY OBJECTIVE: We aimed to determine the role of inferior vena cava (IVC) diameter in making a differentiation between dyspnea of cardiac (acute heart failure [AHF]) and pulmonary origin. We also attempted to determine the best sonographic method for the measurement of IVC diameter. METHODS: This prospective observational study was conducted at the intensive care unit of the emergency department of a training and research hospital. This study enrolled patients with the main symptom of dyspnea who were categorized into 2 groups, cardiac dyspnea and pulmonary dyspnea groups, based on the final diagnosis. All patients underwent sonographic measurement of minimum and maximum diameters of IVC, and the caval index (CI) was calculated in both M-mode and B-mode. The sensitivity, specificity, and likelihood ratios (LR) of the IVC values for the differentiation of the 2 groups were calculated. RESULTS: This study included a total of 74 patients with a mean age of 72.8 years. Thirty-two patients had dyspnea of cardiac origin, and 42 patients had dyspnea of pulmonary origin. The IVC diameter measured with B-mode during inspiration (B-mode i) was the most successful method for differentiation of the 2 groups. B-mode i values greater than 9 mm predicted dyspnea of cardiac origin with a sensitivity of 84.4% and a specificity of 92.9% (+LR: 11.8, LR: 0.16). CONCLUSION: Sonographic assessment of the IVC diameter may be used as a rapid, readily, nonexpensive, complication-free, and reproducible technique for the differentiation of cardiac and pulmonary causes of dyspnea. B-mode i measurement may be more successful in the differentiation of dyspnea compared with other IVC diameters and calculations.


Assuntos
Dispneia/etiologia , Insuficiência Cardíaca/diagnóstico , Pneumonia/diagnóstico , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Embolia Pulmonar/diagnóstico , Veia Cava Inferior/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Diagnóstico Diferencial , Progressão da Doença , Ecocardiografia , Serviço Hospitalar de Emergência , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Tamanho do Órgão , Pneumonia/complicações , Pneumonia/diagnóstico por imagem , Estudos Prospectivos , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Sensibilidade e Especificidade , Veia Cava Inferior/patologia
2.
Am J Emerg Med ; 33(3): 433-8, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25616587

RESUMO

OBJECTIVES: This study aims to determine the site of and the best sonographic method for measurement of inferior vena cava (IVC) diameter in volume status monitoring. METHODS: This observational before-and-after study was performed at the intensive care unit of the emergency department. It included hypotensive adult patients with suspected sepsis who were recommended to receive at least 20 mg/kg fluid replacement by the emergency physician. The patients were fluid replaced at a rate of 1000 mL/h, and maximum and minimum IVC diameters were measured and the Caval index calculated sonographically via both B-mode and M-mode. Hence, IVC's volume response was assessed by a total of 6 parameters, 3 each in M-mode and B-mode. Freidman test was used to assess the change in IVC diameter with fluid replacement. Wilcoxon test with Bonferroni correction was used to determine which measurement method more sensitively measured IVC diameter change. RESULTS: Twenty-eight patients with a mean age of 71.3 were included in the final analysis.The IVC diameter change was significant with all 6 methods (P < .001). The IVC minimum diameter change measured on M-mode during inspiration (M-mode i) was the only measurement method that significantly showed diameter change with each 500-mL fluid replacements. The initial and the subsequent M-mode i values after each 500 mL of fluid were 5.65 ± 3.34; 8.05 ± 3.66; 10.16 ± 3.61, and 11.21 ± 2.94, respectively (P < .001, P < .002, and P < .003, respectively). CONCLUSION: Inferior vena cava diameter was changed by fluid administration. The M-mode i method that most sensitively measures that change may be the most successful method in volume status monitoring.


Assuntos
Hidratação , Hipotensão/diagnóstico por imagem , Veia Cava Inferior/diagnóstico por imagem , Desequilíbrio Hidroeletrolítico/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Serviço Hospitalar de Emergência , Feminino , Humanos , Hipotensão/etiologia , Hipotensão/terapia , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Estudos Prospectivos , Sepse/complicações , Ultrassonografia , Desequilíbrio Hidroeletrolítico/etiologia , Desequilíbrio Hidroeletrolítico/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA