Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
1.
Artigo em Alemão | MEDLINE | ID: mdl-38748284

RESUMO

The implantation of electrodes for cardiac implantable electronic devices (CIED) requires profound technical understanding and precise execution. The positioning of electrodes in the right ventricle and atrium has significant implications for patient safety and the effectiveness of CIED therapy. Particular focus is given to the distinction between apical and septal stimulation in ventricular positioning. Based on current data, this article provides a practice-oriented guide that leads implanters through the individual steps of electrode positioning. The implantation of electrodes for physiological stimulation (cardiac resynchronization therapy, CRT, and conduction system pacing, CSP) is not addressed in this article.

2.
PLoS One ; 19(4): e0302404, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38630693

RESUMO

AIMS: Embolic stroke of undetermined source (ESUS) accounts for up to 20% of ischemic strokes annually. Undetected atrial fibrillation (AF) is one important potential underlying cause. For AF, oral anticoagulation has evolved as the most preferable means of secondary stroke prevention. To detect unrecognized paroxysmal AF, long-term ECG monitoring is required, and implantable cardiac monitors (ICM) appear most suitable. Yet, ICMs are particularly costly, implantation is invasive, and remote monitoring places a personnel burden on health care providers. Here, we use data from a large cohort of ESUS patients to systematically analyze the effort of ICM remote monitoring for AF diagnosis and the strain on health care providers. METHODS AND RESULTS: From a prospective, single-center, observational ESUS registry, we analyzed all ICM-equipped patients post-ESUS (n = 172) between January 1st, 2018, and December 31st, 2019. Through January 2nd, 2023, 48 patients (27.9%) were diagnosed with AF by ICM remote monitoring. During follow-up, a total of 29,180 remote monitoring episodes were transmitted, of which 17,742 were alarms for AF. A systematic estimation of workload revealed that on average, 20.3 trained physician workhours are required to diagnose one patient with AF. CONCLUSION: ICM remote monitoring is useful to diagnose AF in cohort of post-ESUS patients. However, the number of ICM alarms is high, even in a cohort at known high risk of AF and in whom AF detection is therapeutically consequential. Improved automated event classification, clear recommendations for ICM interrogation after AF diagnosis, and a careful patient selection for ICM monitoring are warranted.


Assuntos
Fibrilação Atrial , AVC Embólico , Acidente Vascular Cerebral , Humanos , AVC Embólico/complicações , Estudos Prospectivos , Fatores de Risco , Fibrilação Atrial/complicações
3.
JACC Cardiovasc Interv ; 17(8): 1020-1028, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38658116

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an effective and safe therapy for severe aortic stenosis. Rapid or fast pacing is required for implantation, which can be performed via a pre-existing cardiac implantable electric device (CIED). However, safety data on CIEDs for pacing in TAVR are missing. OBJECTIVES: The aim of this study was to elucidate procedural safety and feasibility of internal pacing with a CIED in TAVR. METHODS: Patients undergoing TAVR with a CIED were included in this analysis. Baseline characteristics, procedural details, and complications according to Valve Academic Research Consortium 3 (VARC-3) criteria after TAVR were compared between both groups. RESULTS: A total of 486 patients were included. Pacing was performed using a CIED in 150 patients and a transient pacemaker in 336 patients. No differences in technical success according to VARC-3 criteria or procedure duration occurred between the groups. The usage of transient pacers for pacing was associated with a significantly higher bleeding rate (bleeding type ≥2 according to VARC-3-criteria; 2.0% vs 13.1%; P < 0.01). Furthermore, impairment of the CIED appeared in 2.3% of patients after TAVR only in the group in which pacing was performed by a transient pacer, leading to surgical revision of the CIED in 1.3% of all patients when transient pacemakers were used. CONCLUSIONS: Internal pacing using a CIED is safe and feasible without differences of procedural time and technical success and might reduce bleeding rates. Furthermore, pacing using a CIED circumvents the risk of lead dislocation. Our data provide an urgent call for the use of a CIED for pacing during a TAVR procedure in general.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Estimulação Cardíaca Artificial , Estudos de Viabilidade , Hospitais com Alto Volume de Atendimentos , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Resultado do Tratamento , Fatores de Tempo , Idoso , Fatores de Risco , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Estudos Retrospectivos , Índice de Gravidade de Doença , Medição de Risco
4.
Herzschrittmacherther Elektrophysiol ; 35(1): 83-90, 2024 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-38289503

RESUMO

Cardiovascular implantable electronic devices (CIED) are an important part of modern cardiology and careful perioperative planning of these procedures is necessary. All information relevant to the indication, the procedure, and the education of the patient must be available prior to surgery. This provides the basis for appropriate device selection. Preoperative antibiotic prophylaxis and perioperative anticoagulation management are essential to prevent infection. After surgery, postoperative monitoring, telemetric control, and device-based diagnostics are required before discharge. These processes need to be adapted to the increasing trend towards outpatient care. This review summarises perioperative management based on practical considerations.


Assuntos
Cardiologia , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos
5.
Herzschrittmacherther Elektrophysiol ; 34(4): 339-350, 2023 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-37917360

RESUMO

Lead extraction due to infection or lead dysfunction has become more important in recent years. Patients with high risk of severe and life-threatening complications should only undergo surgery in experienced centers where appropriate personnel and equipment are available. In this review, different techniques and methods to safely and successfully perform transvenous lead extraction are summarized.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Resultado do Tratamento , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Estudos Retrospectivos
6.
Int J Cardiol ; 390: 131269, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37591414

RESUMO

BACKGROUND: Current standards of ablation of premature ventricular complexes (PVC) combine modern hard- and software mapping and ablation features like multielectrode mapping catheters (MEC), contact force (CF) guided ablation catheters and pattern matching filters (PMF). Benefits of these individual tools were described for selected patients with PVC, but data on combination of these features in the real world setting is sparse. METHODS: Between 2015 and 2021 we retrospectively enrolled 172 consecutive patients undergoing PVC ablation in our center. The utilization of MEC, CF guided ablation catheters and PMF software was analyzed in terms of procedural data, acute and long-term success after 12 months. RESULTS: Acute ablation success was reached in 71% of patients (n = 118) with an overall recurrence rate of 34% after 12 months. PMF software was used in 130 patients (78%), MEC in 131 patients (79%) and ablation was guided using CF in 99 patients (60%). PMF significantly reduced procedural duration and time of radiofrequency application (RF, 150 vs. 185 min, p 0.04 and 325 vs. 556 min, p 0.01). CF enabled significantly shorter radiation time (7.9 vs. 12.3 min, p 0.01), whereas MEC did not influence procedural data. Acute and long-term outcomes were not affected by these modern mapping and ablation features, yet, multivariable regression analysis revealed an underlying cardiomyopathy and the respective focus as independent predictors for recurrence. CONCLUSION: Contemporary hard- and software mapping and ablation features could reduce procedural, radiation and RF time in PVC ablation. Furthermore, patient characteristics rather than technical factors alter outcome of this all-comer collective.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Estudos Retrospectivos , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Catéteres , Software
7.
Herzschrittmacherther Elektrophysiol ; 34(3): 250-255, 2023 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-37460626

RESUMO

Various venous access routes in the region of the clavicle are available for cardiac device treatment. After many years of choosing access via the subclavian vein, current data explicitly show that lateral approaches such as preparation of the cephalic vein or puncture of the axillary vein are clearly superior in terms of probe durability and risk of complications. This article describes the preparation and performance of the various access techniques and is intended to provide a practical guide for the work in cardiac pacemaker operations. This work continues a series of articles designed for advanced training in specialized rhythmology.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Resultado do Tratamento , Veia Subclávia , Veia Axilar
8.
Europace ; 25(4): 1249-1276, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-37061780

RESUMO

There is an increasing proportion of the general population surviving to old age with significant chronic disease, multi-morbidity, and disability. The prevalence of pre-frail state and frailty syndrome increases exponentially with advancing age and is associated with greater morbidity, disability, hospitalization, institutionalization, mortality, and health care resource use. Frailty represents a global problem, making early identification, evaluation, and treatment to prevent the cascade of events leading from functional decline to disability and death, one of the challenges of geriatric and general medicine. Cardiac arrhythmias are common in advancing age, chronic illness, and frailty and include a broad spectrum of rhythm and conduction abnormalities. However, no systematic studies or recommendations on the management of arrhythmias are available specifically for the elderly and frail population, and the uptake of many effective antiarrhythmic therapies in these patients remains the slowest. This European Heart Rhythm Association (EHRA) consensus document focuses on the biology of frailty, common comorbidities, and methods of assessing frailty, in respect to a specific issue of arrhythmias and conduction disease, provide evidence base advice on the management of arrhythmias in patients with frailty syndrome, and identifies knowledge gaps and directions for future research.


Assuntos
Fragilidade , Humanos , Idoso , Fragilidade/diagnóstico , Fragilidade/epidemiologia , Fragilidade/terapia , Idoso Fragilizado , Consenso , América Latina , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Doença do Sistema de Condução Cardíaco
9.
Int J Cardiol ; 381: 16-19, 2023 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-37044179

RESUMO

BACKGROUND: Implantable electronic cardiac devices (CIED) have emerged as an essential component in the treatment of cardiac arrhythmias and heart failure. Due to increased life expectancy, expanding indications and limited technical survival, an increasing number of revision procedures can be anticipated. Venous access site occlusion (VASO) is the main obstacle during revision surgery. In this retrospective study we evaluated the prevalence, predictive parameters and operative management of venous access site occlusion. METHODS AND RESULTS: Between 01/2016 and 12/2020 304 patients underwent lead revision surgery of transvenous CIED in our department. Prevalence of VASO was 25.7% (n = 78), one patient was symptomatic. Independent predicting clinical parameters were male sex (2.86 (1.39-5.87), p < 0.01) and lead age (1.11 (1.05-1.18), p < 0.01)). Revision surgery despite VASO was successful in 97.4% (n = 76) without prolongation of the total surgery time or higher complication rates. Yet, lead extraction was possible in 92% of patients with VASO vs. 98.2% of patients without VASO (p 0.01). CONCLUSION: VASO is a frequent condition in patients undergoing lead revision surgery, but successful revision is feasible in most cases without preceding lead extraction. However, the lower success rates of lead extractions may be prognostically relevant, especially for younger patients.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Doenças Vasculares , Humanos , Masculino , Feminino , Desfibriladores Implantáveis/efeitos adversos , Estudos Retrospectivos , Reoperação/métodos , Prevalência , Resultado do Tratamento , Remoção de Dispositivo/métodos
10.
Patient Prefer Adherence ; 17: 433-440, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36815129

RESUMO

Background: Treatment with wearable cardioverter defibrillators (WCD) is a non-invasive, transient therapy option for prevention of sudden cardiac death (SCD) in patients with temporary contraindications for implantation of a permanent cardioverter defibrillator. Due to the constant risk of fatal arrhythmias, compliance is the fundamental requirement for effectiveness of a WCD, but this might be hindered by the poor quality-of-life (QoL) during WCD therapy. In this retrospective single-center study, we examined if a standardized WCD training and adherence surveillance programme could enhance compliance and QoL. Methods: All patients with a prescription for WCD treatment from January 2017 to August 2019 were included and received a standardized WCD training programme. QoL was validated using the modified EQ-5D-3L questionnaire. The findings were compared to a historical, previously published, retrospective cohort from our center (WCD prescription period 03/2012-02/2016), not receiving the additional training programme. Endpoints comprised therapy adherence, arrhythmic episodes, and dimensions of QoL. Results: Ninety-two patients underwent WCD treatment in the study cohort for a median of 49 days. Median daily wear time was enhanced in the study cohort (historical cohort vs study cohort 21.9 vs 23.3 hours/per day, p<0.01) and artefact alarms occurred less frequently (67.9% vs 48.9%, p 0.01). Major restrictions in QoL in the study cohort were found in mobility (48%), daily routine (44%), and sleep (49%), but the dimensions pain (36% vs 4%, p<0.01), mental health (43% vs 29%, p 0.03), and restrictions in daily routine (48% vs 30%, p 0.04) improved. Conclusion: A standardized training and adherence surveillance programme might have beneficial effects on compliance and QoL. As these findings are essential for therapy success, they might potentially lead to a reduction in arrhythmic deaths in upcoming WCD trials.

12.
Herzschrittmacherther Elektrophysiol ; 33(4): 467-475, 2022 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-36342506

RESUMO

In this article, typical characteristics of focal atrial tachycardias are described and a systematic approach regarding diagnostics and treatment options in the field of invasive cardiac electrophysiology (EP) is presented. Subjects of this article include the definition of focal atrial tachycardias, knowledge about localizing the origin of such, and guidance on how to approach an invasive EP study (e.g., administration of medication during the EP study to provoke tachycardias). Further, descriptions will be found on how to localize the origin of focal atrial tachycardias with the help of the 12-lead ECG and invasive three-dimensional mapping to successfully treat focal atrial tachycardias with catheter ablation.


Assuntos
Ablação por Cateter , Taquicardia Atrial Ectópica , Humanos , Ablação por Cateter/métodos , Taquicardia/cirurgia , Eletrocardiografia/métodos
13.
Patient Prefer Adherence ; 16: 3027-3033, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36387054

RESUMO

Background: The subcutaneous cardioverter defibrillator (S-ICD) has been shown to be a viable alternative to transvenous ICDs (TV-ICD) in all patients at risk of sudden cardiac death (SCD) but without pacing indication. Aim: The aim of this study was to examine the impact of therapy with current S-ICD devices on quality of life (QoL) in comparison to patients with TV-ICD devices. Methods: In our single-centre study, 52 consecutive patients with S-ICD and 52 matched patients with TV-ICD were analysed. QoL has been assessed by a standardized questionnaire (EQ-5D-3L, modified). Additionally, clinical baseline and follow-up data were evaluated. Results: Two-thirds of the total study population reported restrictions in daily routine compared to their life before ICD implantation. A total of 27.7% of S-ICD patients stated to expect an improvement of QoL by deactivation or explantation of their defibrillator compared to only 6.4% of patients with TV-ICD (p=0.006), which was mainly caused by discomfort and pain from the S-ICD pocket (relevant discomfort and pain in 32.6% vs 11.5%; p<0.01). Limitations: Main limitation of the study is that quality of life was assessed for one single time point only and time since implantation differed significantly between S-ICD and TV-ICD. Furthermore our collective is younger, and, due to the high proportion of patients without cardiomyopathy, the mean EF is better than usual ICD collective. The absence of heart failure in about the half of our patients might have relevant impact on our QoL analysis. Conclusion: A relevant proportion of S-ICD patients expects an improvement of QoL by explantation of the device. Of note, this impression was not driven by the fear of receiving shocks but mainly by discomfort and pain caused by the pulse generator.

15.
Herzschrittmacherther Elektrophysiol ; 33(3): 341-350, 2022 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-35986095

RESUMO

In contrast to typical atrial flutter, atypical atrial flutter is a heterogeneous group of right and left atrial macro- or localized reentry tachycardias whose critical component for maintaining tachycardia is not the cavotricuspid isthmus. Atypical atrial flutter occurs more frequently after previous catheter ablation and after cardiac surgery. The intraprocedural success rate during ablation is high, although the recurrence rate depends on structural changes in the atria as well as the underlying mechanism. This article provides an overview of the mechanisms as well as mapping and ablation strategies of the most common forms of right and left atrial atypical atrial flutter. This article is part of the "EP Basics" series for targeted continuing education in invasive electrophysiology. Basics, clinic and therapy of atypical atrial flutter are presented with focus on clinically relevant aspects. Procedures and findings of invasive electrophysiological diagnostics and ablation treatment are the focus of this article.


Assuntos
Fibrilação Atrial , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Humanos , Taquicardia/cirurgia
16.
Sci Rep ; 12(1): 9139, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35650230

RESUMO

Ultra-high-density (UHD) mapping can improve scar area detection and fast activation mapping in patients undergoing catheter ablation of ventricular tachycardia (VT). The aim of the present study was to compare the outcome after VT ablation guided by UHD and conventional point-by-point 3D-mapping. The acute and long-term ablation outcome of 61 consecutive patients with UHD mapping (64-electrode mini-basket catheter) was compared to 61 consecutive patients with conventional point-by-point 3D-mapping using a 3.5 mm tip catheter. Patients, whose ablation was guided by UHD mapping had an improved 24-months outcome in comparison to patients with conventional mapping (cumulative incidence estimate of the combination of recurrence or disease-related death of 52.4% (95% confidence interval (CI) [36.9-65.7]; recurrence: n = 25; disease-related death: n = 4) versus 69.6% (95% CI [55.9-79.8]); recurrence: n = 31; disease-related death n = 11). In a cause-specific Cox proportional hazards model, UHD mapping (hazard ratio (HR) 0.623; 95% CI [0.390-0.995]; P = 0.048) and left ventricular ejection fraction > 30% (HR 0.485; 95% CI [0.290-0.813]; P = 0.006) were independently associated with lower rates of recurrence or disease-related death. Other procedural parameters were similar in both groups. In conclusion, UHD mapping during VT ablation was associated with fewer VT recurrences or disease-related deaths during long-term follow-up in comparison to conventional point-by-point mapping. Complication rates and other procedural parameters were similar in both groups.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Mapeamento Potencial de Superfície Corporal , Ablação por Cateter/efeitos adversos , Humanos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
17.
Sci Rep ; 12(1): 8199, 2022 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-35581374

RESUMO

Postmortal interrogation of cardiac implantable electrical devices (CIED) may contribute to the determination of time of death in forensic medicine. Recent studies aimed to improve estimation of time of death by combining findings from autopsy, CIED interrogation and patients´ medical history. CIED from deceased undergoing forensic autopsy were included, if time of death remained unclear after forensic assessment. CIED explanted from deceased with known time of death were analysed as a control cohort. CIED were sent to our device interrogation lab and underwent analysis blinded for autopsy findings, medical history and police reports. The accuracy of time of death determination and the accuracy of time of death in the control cohort served as primary outcome. A total of 87 CIED were analysed. The determination of time of death was possible in 54 CIED (62%, CI 52-72%). The accuracy of the estimated time of death was 92.3% in the control cohort. Certain CIED type and manufacturers were associated with more successful determination. Blinded postmortal analysis enables a valid determination of the time of death in the majority of CIED. Analysis of explanted CIED in a cardiological core lab is feasible and should be implemented in forensic medicine.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Autopsia , Estudos de Coortes , Medicina Legal , Humanos , Estudos Retrospectivos
19.
Herzschrittmacherther Elektrophysiol ; 33(1): 88-97, 2022 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-35157112

RESUMO

Radiofrequency (RF) ablation is an effective treatment option of scar-related ventricular tachycardias (VT) in patients with ischemic cardiomyopathy. Several studies proved the benefit of VT catheter ablation, which has become routine in most electrophysiology laboratories. This article provides practical instructions to perform a VT catheter ablation. The authors describe conventional and substrate-based mapping and ablation strategies as well as concepts for image integration. This article continues a series of publications created for education in advanced electrophysiology.


Assuntos
Cardiomiopatias , Ablação por Cateter , Isquemia Miocárdica , Taquicardia Ventricular , Cardiomiopatias/cirurgia , Ablação por Cateter/métodos , Humanos , Isquemia Miocárdica/complicações , Isquemia Miocárdica/cirurgia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
20.
Clin Cardiol ; 45(3): 291-298, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35019172

RESUMO

INTRODUCTION: Catheter ablation is the treatment of choice for recurrent focal atrial tachycardia (FAT) as medical therapy is limited. Routinely, a three-dimensional mapping system is used. Whether or not optimized signal detection does improve ablation success rates has not yet been investigated. This retrospective cohort study compared ablation procedures using an ultra-high-density mapping system (UHDM, Rhythmia, Boston Scientific) with improved signal detection and automatic annotation with procedures using a conventional electroanatomic mapping system (CEAM, Biosense Webster, CARTO). METHODS: All patients undergoing ablation for FAT using UHDM or CEAM from April 2015 to August 2018 were included. Endpoints comprised procedural parameters, acute success as well as freedom from arrhythmia 12 months after ablation. RESULTS: A total of 70 patients underwent ablation (48 with UHDM, 22 with CEAM). No significant differences were noted for parameters like procedural and radiation duration, area dose, and RF applications. Acute success was significantly higher in the UHDM cohort (89.6% vs. 68.2%, p = .03). Nevertheless, arrhythmia freedom 12 months after ablation was almost identical (56.8% vs. 60%, p = .87), as more patients with acute success of ablation presented with a relapse during follow-up (35.0 vs. 7.7%, p = .05). CONCLUSION: Acute success rate of FAT ablation might be improved by UHDM, without an adverse effect on procedural parameters. Nevertheless, further research is needed to understand the underlying mechanism for increased recurrence rates after acute successful ablation.


Assuntos
Ablação por Cateter , Arritmias Cardíacas , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Estudos Retrospectivos , Taquicardia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA