Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Drug Test Anal ; 9(4): 613-625, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27328899

RESUMO

The knowledge of pharmacokinetic (PK) properties of synthetic cannabinoids (SCs) is important for interpretation of analytical results found for example in intoxicated individuals. In the absence of human data from controlled studies, animal models elucidating SC PK have to be established. Pigs providing large biofluid sample volumes were tested for prediction of human PK data. In this context, the metabolic fate of two model SCs, namely 4-ethylnaphthalen-1-yl-(1-pentylindol-3-yl)methanone (JWH-210) and 2-(4-methoxyphenyl)-1-(1-pentyl-indol-3-yl)methanone (RCS-4), was elucidated in addition to Δ9 -tetrahydrocannabinol (THC). After intravenous administration of the compounds, hourly collected pig urine was analyzed by liquid chromatography-high resolution mass spectrometry. The following pathways were observed: for JWH-210, hydroxylation at the ethyl side chain or pentyl chain and combinations of them followed by glucuronidation; for RCS-4, hydroxylation at the methoxyphenyl moiety or pentyl chain followed by glucuronidation as well as O-demethylation followed by glucuronidation or sulfation; for THC, THC glucuronidation, 11-hydroxylation, followed by carboxylation and glucuronidation. For both SCs, parent compounds could not be detected in urine in contrast to THC. These results were consistent with those obtained from human hepatocyte and/or human case studies. Urinary markers for the consumption of JWH-210 were the glucuronide of the N-hydroxypentyl metabolite (detectable for 3-4 h) and of RCS-4 the glucuronides of the N-hydroxypentyl, hydroxy-methoxyphenyl (detectable for at least 6 h), and the O-demethyl-hydroxy metabolites (detectable for 4 h). Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Canabinoides/urina , Dronabinol/urina , Drogas Ilícitas/urina , Indóis/urina , Naftalenos/urina , Psicotrópicos/urina , Suínos/urina , Animais , Canabinoides/metabolismo , Cromatografia Líquida/métodos , Dronabinol/metabolismo , Humanos , Drogas Ilícitas/metabolismo , Indóis/metabolismo , Naftalenos/metabolismo , Psicotrópicos/metabolismo , Detecção do Abuso de Substâncias/métodos , Suínos/metabolismo , Espectrometria de Massas em Tandem/métodos
2.
Curr Neuropharmacol ; 15(5): 713-723, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27834143

RESUMO

BACKGROUND: Synthetic cannabinoids (SCs) have become an increasing issue in forensic toxicology. Controlled human studies evaluating pharmacokinetic data of SCs are lacking and only few animal studies have been published. Thus, an interpretation of analytical results found in intoxicated or poisoned individuals is difficult. Therefore, the distribution of two selected SCs, namely 4-ethylnaphthalen-1-yl-(1-pentylindol-3-yl)methanone (JWH-210) and 2-(4-methoxyphenyl)-1-(1- pentyl-indol-3-yl)methanone (RCS-4) as well as Δ9-tetrahydrocannabinol (THC) as reference were examined in pigs. METHODS: Pigs (n = 6 per drug) received a single intravenous 200 µg/kg BW dose of JWH-210, RCS- 4, or THC. Six hours after administration, the animals were exsanguinated and relevant organs, important body fluids such as bile, and tissues such as muscle and adipose tissue, as well as the bradytrophic specimens dura and vitreous humor were collected. After hydrolysis and solid phase extraction, analysis was performed by LC-MS/MS. To overcome matrix effects of the LC-MS/MS analysis, a standard addition method was applied for quantification. RESULTS: The parent compounds could be detected in every analyzed specimen with the exception of THC that was not present in dura and vitreous humor. Moderate concentrations were present in brain, the site of biological effect. Metabolite concentrations were highest in tissues involved in metabolism and/or elimination Conclusions: Besides kidneys and lungs routinely analyzed in postmortem toxicology, brain, adipose, and muscle tissue could serve as alternative sources, particularly if other specimens are not available. Bile fluid is the most appropriate specimen for SCs and THC metabolites detection.


Assuntos
Canabinoides/metabolismo , Canabinoides/farmacocinética , Dronabinol/metabolismo , Dronabinol/farmacocinética , Indóis/metabolismo , Indóis/farmacocinética , Naftalenos/metabolismo , Naftalenos/farmacocinética , Administração Intravenosa , Animais , Encéfalo/metabolismo , Canabinoides/administração & dosagem , Cromatografia Líquida , Dronabinol/administração & dosagem , Indóis/administração & dosagem , Rim/metabolismo , Fígado/metabolismo , Pulmão/metabolismo , Naftalenos/administração & dosagem , Músculos Psoas/metabolismo , Baço/metabolismo , Suínos , Espectrometria de Massas em Tandem , Distribuição Tecidual
3.
Toxicol Lett ; 253: 7-16, 2016 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-27113702

RESUMO

Synthetic cannabinoids (SCs) are gaining increasing importance in clinical and forensic toxicology. They are consumed without any preclinical safety studies. Thus, controlled human pharmacokinetic (PK) studies are not allowed, although being relevant for interpretation of analytical results in cases of misuse or poisoning. As alternative, in a controlled animal experiment, six pigs per drug received a single intravenous dose of 200µg/kg BW each of Δ(9)-tetrahydrocannabinol (THC), 4-ethylnaphthalen-1-yl-(1-pentylindol-3-yl)methanone (JWH-210), or 2-(4-methoxyphenyl)-1-(1-pentyl-indol-3-yl)methanone (RCS-4). In addition, six pigs received a combination of the three drugs with the identical dose each. The drugs were determined in serum using LC-MS/MS. A population (pop) PK analysis revealed that a three-compartment model described best the PK data of all three cannabinoids. Central volumes of distribution were estimated at 0.29L/kg, 0.20L/kg, and 0.67L/kg for THC, JWH-210, and RCS-4, respectively. Clearances were 0.042L/min/kg, 0.048L/min/kg, and 0.093L/min/kg for THC, JWH-210, and RCS-4, respectively. The popPK THC pig model was upscaled to humans using allometric techniques. Comparison with published human data revealed that the concentration-time profiles could successfully be predicted. These findings indicate that pigs in conjunction with PK modeling technique may serve as a tool for prediction of human PK of SCs.


Assuntos
Canabinoides/farmacocinética , Dronabinol/farmacocinética , Toxicologia Forense/métodos , Indóis/farmacocinética , Naftalenos/farmacocinética , Animais , Canabinoides/administração & dosagem , Canabinoides/sangue , Canabinoides/síntese química , Cromatografia Líquida , Dronabinol/administração & dosagem , Dronabinol/sangue , Dronabinol/síntese química , Indóis/administração & dosagem , Indóis/sangue , Indóis/síntese química , Injeções Intravenosas , Masculino , Modelos Animais , Modelos Biológicos , Naftalenos/administração & dosagem , Naftalenos/sangue , Naftalenos/síntese química , Especificidade da Espécie , Suínos , Espectrometria de Massas em Tandem
4.
Drug Test Anal ; 8(10): 1080-1089, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26607679

RESUMO

Based on a similar approach for quantification of antidepressants, benzodiazepines, and z-drugs, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) multi-analyte approach with simple liquid-liquid extraction was extended for fast target screening and quantification of neuroleptics in whole blood, plasma, and serum. As this method is part of a multi-analyte procedure for over 100 analytes from different drug classes and as the extracts were additionally used in the authors' laboratory for gas chromatography-mass spectrometry (GC-MS) analysis, one universal stable-isotope-labelled internal standard (SIL-IS) was used to save time and resource. The method was validated with respect to international guidelines. For accuracy and precision, full calibration was performed with ranges from subtherapeutic to toxic concentrations. Selectivity problems could not be observed, but matrix effects ranged from 68 to 211% in all samples. For the low quality control (QC), recovery ranged from 32 to 112%, process efficiency from 31 to 165% and for the high QC recovery from 42 to 141%, process efficiency from 29 to 154%. In addition statistical data evaluation of the variances of the recovery, matrix effects, and process efficiency data between whole blood vs. plasma, whole blood vs. serum, and plasma vs. serum were done. The presented LC-MS/MS approach was applicable for selective detection of 33 neuroleptics as well as accurate and precise quantification of 25 neuroleptics in whole blood, 19 in plasma, and 17 in serum. More significant matrix effects (ME) for neuropletic drugs overall in plasma and serum as compared with whole blood were detected. Copyright © 2015 John Wiley & Sons, Ltd.


Assuntos
Antidepressivos/análise , Antidepressivos/química , Benzodiazepinas/análise , Benzodiazepinas/química , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Plasma/química , Espectrometria de Massas em Tandem/métodos , Antipsicóticos/sangue , Humanos , Limite de Detecção
5.
Med Monatsschr Pharm ; 38(3): 87-93, 2015 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-26364394

RESUMO

The characterisation of new psychoactive drugs which were identified in the last years in continuously increasing numbers is a challenge for different academic institutions. This paper gives an overview on new psychoactive drugs in regard of their chemistry, pharmacology, metabolism, analytics and legal aspects in Germany.


Assuntos
Legislação de Medicamentos/tendências , Psicotrópicos/farmacologia , Alemanha/epidemiologia , Humanos , Psicotrópicos/análise , Psicotrópicos/metabolismo , Transtornos Relacionados ao Uso de Substâncias/epidemiologia , Transtornos Relacionados ao Uso de Substâncias/psicologia
6.
Anal Bioanal Chem ; 407(13): 3775-86, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25772567

RESUMO

A series of new synthetic cannabinoids (SC) has been consumed without any toxicological testing. For example, pharmacokinetic data have to be collected from forensic toxicological case work and/or animal studies. To develop a corresponding model for assessing such data, samples of controlled pig studies with two selected SC (JWH-210, RCS-4) and, as reference, ∆(9)-tetrahydrocannabinol (THC) should be analyzed as well as those of human cases. Therefore, a method for determination of JWH-210, RCS-4, THC, and their main metabolites in pig and human serum, whole blood, and urine samples is presented. Specimens were analyzed by liquid-chromatography tandem mass spectrometry and multiple-reaction monitoring with three transitions per compound. Full validation was carried out for the pig specimens and cross-validation for the human specimens concerning precision and bias. For the pig studies, the limits of detection were between 0.05 and 0.50 ng/mL in serum and whole blood and between 0.05 and 1.0 ng/mL in urine, the lower limits of quantification between 0.25 and 1.0 ng/mL in serum and 0.50 and 2.0 ng/mL in whole blood and urine, and the intra- and interday precision values lower than 15% and bias values within ±15%. The applicability was tested with samples taken from a pharmacokinetic pilot study with pigs following intravenous administration of a mixture of 200 µg/kg body mass dose each of JWH-210, RCS-4, and THC. The cross-validation data for human serum, whole blood, and urine showed that this approach should also be suitable for human specimens, e.g., of clinical or forensic cases.


Assuntos
Canabinoides/metabolismo , Cromatografia Líquida de Alta Pressão/métodos , Drogas Ilícitas/metabolismo , Espectrometria de Massas por Ionização por Electrospray/métodos , Detecção do Abuso de Substâncias/métodos , Animais , Análise Química do Sangue/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Especificidade da Espécie , Suínos , Urinálise/métodos
7.
Drug Test Anal ; 7(3): 214-40, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24753436

RESUMO

In the present study, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) multi-analyte approach using one single work-up approach in whole blood, plasma, serum, post-mortem blood, liver tissue, gastric content, hair, and urine was developed for fast target screening and reliable identification of 130 analytes often requested in clinical and forensic toxicology. Samples (500 µL each) of whole blood, plasma, serum, post-mortem blood, tissue (homogenized 1 + 4 with water), as well as 3 g of distilled gastric contents, 1 mL of urine, or 20 mg of pulverized hair were extracted at different pH values with an diethyl ether-ethyl acetate mixture (1:1). Separation and identification were performed using LC-QTRAP with electrospray ionization in positive mode. For identification 1 scheduled multi-reaction-mode (sMRM) method with 390 transitions was developed covering benzodiazepines, Z-drugs, antidepressants, neuroleptics, opioids, new synthetic drugs, and phosphodiesterase type 5 inhibitors. For positive sMRM transitions with intensities exceeding 5000 cps, dependent scans (EPI scan collision energy, 35 eV, collision energy spread, 15 eV) were performed for library search using our in-house library. The method was developed with respect to selectivity, matrix effects, recovery, process efficiency, limit of detection, and applicability. The simple work-up procedure was suitable for all biosamples with exception of urine in respect to low concentrated analytes, which showed median recovery values of 59%. The method was selective for 130 analytes in all 8 biosamples. For 106 analytes, the limit of detection in whole blood, plasma, and serum was lower than the lowest therapeutic concentration listed in blood level lists.


Assuntos
Cromatografia Líquida/métodos , Preparações Farmacêuticas/sangue , Preparações Farmacêuticas/urina , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/economia , Toxicologia Forense/economia , Toxicologia Forense/métodos , Suco Gástrico/química , Cabelo/química , Humanos , Limite de Detecção , Fígado/química , Preparações Farmacêuticas/análise , Espectrometria de Massas em Tandem/economia
8.
Anal Bioanal Chem ; 406(24): 5939-53, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25023973

RESUMO

In the present study, a liquid chromatography-mass spectrometry (LC-MS/MS) multi-analyte approach based on a simple liquid-liquid extraction was developed for fast target screening and quantification of 33 antidepressants in whole blood, plasma, and serum. The method was validated with respect to selectivity, matrix effects, recovery, process efficiency, accuracy and precision, stabilities, and limits. In addition, cross-calibration between the three biosamples was done to assess the impact of the different matrices on the calibration. Whole blood, plasma, and serum (500 µL each) were extracted twice at pH 7.4 and at pH 10 with ether-ethyl acetate (1:1). Separation, detection, and quantification were performed using LC-MS/MS with electrospray ionization in positive mode. For accuracy and precision, full calibration was performed with ranges from subtherapeutic to toxic concentrations. The approach was sensitive and selective for 33 analytes in whole blood and 31 analytes in plasma and serum and accurate and precise for 30 of the 33 tested drugs in whole blood, 31 in plasma, and 28 in serum. Cross-calibration was successful only for 13 analytes in whole blood and 16 analytes in serum calculated over a calibration curve made in plasma, 12 analytes in whole blood and 15 analytes in plasma calculated over a calibration curve made in serum, and 10 analytes in plasma and 15 analytes in serum calculated over a calibration curve made in whole blood.


Assuntos
Antidepressivos/sangue , Cromatografia Líquida de Alta Pressão/métodos , Plasma/química , Soro/química , Detecção do Abuso de Substâncias/métodos , Espectrometria de Massas em Tandem/métodos
9.
Biomed Chromatogr ; 28(8): 1043-7, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24474420

RESUMO

Synthetic cannabinoids such as alkylindole derivatives entered the illicit drug market worldwide a few years ago. Only a few data are available concerning their pharmacokinetics, in particular their distribution and persistence in adipose tissue. For the present study, rats were administered a single 20 mg/kg oral dose of JWH-210 or JWH-122. After one month, they were dissected and adipose tissue was taken in order to study whether JWH-210 and JWH-122 persisted in this body sample. After extraction, the samples were analyzed by liquid chromatographic-mass spectrometry (LC-QTrap-MS). Validation of the analytical method for adipose tissue is also presented. The results of the matrix effects determination ranged between 30.6 and 43.8%. The limits of detection for JWH-210 and JWH-122 were 0.8 and 1.0 ng/g and lower limits of quantification were 3.7 and 2.1 ng/g, respectively. Calibration curves ranged from 10 to 75 ng/g for JWH-210 and from 5 to 50 ng/g for JWH-122. Intra- and interday precision values were lower than 15% and bias values within ±15%. Applying this method, in adipose tissue specimens obtained 4 weeks after single drug administration, JWH-210 and JWH-122 were detected in concentrations of 116 and 9 ng/g, respectively.


Assuntos
Tecido Adiposo/química , Indóis/análise , Naftalenos/análise , Administração Oral , Animais , Cromatografia Líquida de Alta Pressão , Toxicologia Forense , Indóis/administração & dosagem , Indóis/isolamento & purificação , Limite de Detecção , Masculino , Naftalenos/administração & dosagem , Naftalenos/isolamento & purificação , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem , Fatores de Tempo
10.
Anal Bioanal Chem ; 406(3): 803-18, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24309624

RESUMO

For the first time, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) multi-analyte approach based on a simple liquid-liquid extraction was developed and validated for fast target screening and quantification of benzodiazepines and Z-drugs in case of driving ability and crime responsibility in the three most important biosamples whole blood, plasma, and serum. Whole blood, plasma, and serum (500 µL each) were extracted twice at pH 7.4 and at pH 10 with ether/ethyl acetate (1:1). Separation, detection, and quantification were performed using LC-MS/MS with electrospray ionization in positive mode. The method was validated with respect to selectivity, ion suppression/enhancement of co-eluting analytes, matrix effects, recovery, process efficiency, accuracy and precision, stabilities, and limits of detection and quantification. For accuracy and precision, full calibration was performed with ranges from subtherapeutic to toxic concentrations. The presented LC-MS/MS approach as part of a universal multi-analyte concept for over 100 drugs was applicable for selective detection as well as accurate and precise quantification in whole blood, plasma, and serum. The approach was selective, sensitive, accurate, and precise for 16 of the 19 tested drugs in whole blood, 18 in plasma, and 17 in serum. Only semiquantitative results could be obtained for zopiclone because of its instability in all tested biosamples.


Assuntos
Benzodiazepinas/sangue , Análise Química do Sangue/métodos , Cromatografia Líquida de Alta Pressão , Hipnóticos e Sedativos/análise , Plasma/química , Soro/química , Espectrometria de Massas por Ionização por Electrospray , Acetamidas/análise , Compostos Azabicíclicos/análise , Humanos , Limite de Detecção , Piperazinas/análise , Piridinas/análise , Pirimidinas/análise , Padrões de Referência , Reprodutibilidade dos Testes , Zolpidem
11.
Anal Bioanal Chem ; 405(1): 247-58, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23076398

RESUMO

In the context of driving ability diagnostics in Germany, administrative cutoffs for various drugs and pharmaceuticals in urine have been established. Two liquid chromatography-tandem mass spectrometry methods for simultaneous detection and quantification of amphetamines, designer amphetamines, benzoylecgonine, benzodiazepines, opiates, and opioids in urine were developed and validated. A 500-µL aliquot of urine was diluted and fortified with an internal standard solution. After enzymatic cleavage, online extraction was performed by an ion-exchange/reversed-phase turbulent flow column. Separation was achieved by using a reversed-phase column and gradient elution. For detection, a Thermo Fisher TSQ Quantum Ultra Accurate Mass tandem mass spectrometer with positive electrospray ionization was used, and the analytes were measured in multiple-reaction monitoring mode detecting two transitions per precursor ion. The total run time for both methods was about 15 min. Validation was performed according to the guidelines of the Society of Toxicological and Forensic Chemistry. The results of matrix effect determination were between 78% and 116%. The limits of detection and quantification for all drugs, except zopiclone, were less than 10 ng/mL and less than 25 ng/mL, respectively. Calibration curves ranged from 25 to 200 ng/mL for amphetamines, designer amphetamines, and benzoylecgonine, from 25 to 250 ng/mL for benzodiazepines, from 12.5 to 100 ng/mL for morphine, codeine, and dihydrocodeine, and from 5 to 50 ng/mL for buprenorphine and norbuprenorphine. Intraday and interday precision values were lower than 15%, and bias values within ± 15% were achieved. Turbulent flow chromatography needs no laborious sample preparation, so the workup is less time-consuming compared with gas chromatography-mass spectrometry methods. The methods are suitable for quantification of multiple analytes at the cutoff concentrations required for driving ability diagnostics in Germany.


Assuntos
Anfetaminas/análise , Analgésicos Opioides/análise , Benzodiazepinas/análise , Cromatografia Líquida/métodos , Cocaína/análogos & derivados , Espectrometria de Massas em Tandem/métodos , Urinálise/métodos , Condução de Veículo , Calibragem , Técnicas de Química Analítica , Cromatografia/métodos , Cocaína/análise , Alemanha , Humanos , Controle de Qualidade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo
12.
J Mass Spectrom ; 47(1): 66-71, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22282091

RESUMO

In contrast to libraries with highly reproducible gas chromatography electron ionization mass spectra, current liquid chromatography (LC-MS) libraries are limited to specific instrument types. Therefore, the aim of the study was to prove whether a recently developed linear ion trap (LIT) LC-MS(n) screening approach and reference library can be transferred to an LC-MS/MS system with a quadrupole-LIT hybrid mass analyzer using SmileMS, a sophisticated search algorithm. The LIT reference library was built with MS² and MS³ wideband spectra recorded on a ThermoFisher LXQ LIT with electrospray ionization in positive mode and full-scan data-dependent acquisition (DDA). Collision parameter optimizations, including different scan types and energies, were performed on an Applied Biosystems QTRAP 4000 system using electrospray ionization in positive mode and full-scan DDA. Modified library sets were generated to improve the detection of a compound by the used search algorithm. Additionally, 100 authentic human urine samples were screened by both systems for proof of applicability. In the applicability study, 533 compounds were detected by the LXQ and 477 by the QTRAP system using enhanced product ion scan and a modified database. The presented data showed that the LIT screening approach and reference library could be used successfully on a QTRAP instrument with some limitations. These should be overcome by further optimizations regarding DDA settings for better sensitivity and further library modifications to reduce spectra mismatches.


Assuntos
Cromatografia Líquida/normas , Bases de Dados Factuais , Espectrometria de Massas em Tandem/normas , Algoritmos , Cromatografia Líquida/instrumentação , Cromatografia Líquida/métodos , Humanos , Preparações Farmacêuticas/urina , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray , Estatísticas não Paramétricas , Espectrometria de Massas em Tandem/instrumentação , Espectrometria de Massas em Tandem/métodos
13.
Toxicol Lett ; 183(1-3): 52-7, 2008 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-18938231

RESUMO

The designer drugs 4-methyl-2,5-dimethoxy-amphetamine (DOM), 4-iodo-2,5-dimethoxy-amphetamine (DOI), 4-chloro-2,5-dimethoxy-amphetamine (DOC), 4-bromo-2,5-dimethoxy-amphetamine (DOB), 4-bromo-2,5-dimethoxy-methamphetamine (MDOB), and 2,4,5-trimethoxy-amphetamine (TMA-2) are potent serotonin 5HT(2) receptor agonists and have appeared on the illicit drug market. These drugs are mainly metabolized by O-demethylation or in case of DOM by hydroxylation of the methyl moiety. In an initial activity screening using microsomes of insect cells heterologously expressing human CYPs, CYP2D6 was found to be the only CYP isoenzyme involved in the above-mentioned main metabolic steps whereas the amounts of metabolites formed were very small. As inhibition of CYP2D6 by other amphetamines had been described, the inhibitory effects of the 2,5-dimethoxyamphetamine derivatives were studied using insect cell microsomes with heterologously expressed human CYP2D6 and pooled human liver microsomes (HLM) as enzyme sources and dextromethorphan O-demethylation as probe reaction. All studied drugs were observed to be non-mechanism-based competitive inhibitors of CYP2D6 with inhibition constants (K(i)) from 7.1 to 296microM using recombinant CYP2D6 and 2.7-19.9microM using HLM. For comparison, the K(i) values for quinidine and fluoxetine were 0.0092 and 8.2microM using recombinant CYP2D6 and 0.019 and 0.93microM using HLM. As the K(i) values of the drugs were much higher than that of quinidine and, with the exception of DOI, higher than that of fluoxetine, interactions with other CYP2D6 substrates are possible but rather unlikely.


Assuntos
Anfetaminas/farmacologia , Inibidores das Enzimas do Citocromo P-450 , Drogas Desenhadas/farmacologia , 2,5-Dimetoxi-4-Metilanfetamina/análogos & derivados , 2,5-Dimetoxi-4-Metilanfetamina/química , 2,5-Dimetoxi-4-Metilanfetamina/metabolismo , 2,5-Dimetoxi-4-Metilanfetamina/farmacologia , Algoritmos , Anfetaminas/química , Anfetaminas/metabolismo , Animais , Citocromo P-450 CYP2D6/genética , Citocromo P-450 CYP2D6/metabolismo , Inibidores do Citocromo P-450 CYP2D6 , Sistema Enzimático do Citocromo P-450/genética , Sistema Enzimático do Citocromo P-450/metabolismo , Drogas Desenhadas/química , Drogas Desenhadas/metabolismo , Fluoxetina/química , Fluoxetina/metabolismo , Fluoxetina/farmacologia , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Hidroxilação , Insetos/citologia , Insetos/metabolismo , Cinética , Microssomos Hepáticos/enzimologia , Microssomos Hepáticos/metabolismo , Estrutura Molecular , Quinidina/química , Quinidina/metabolismo , Quinidina/farmacologia , Espectrometria de Massas por Ionização por Electrospray
14.
Anal Bioanal Chem ; 390(7): 1837-42, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18259731

RESUMO

Studies are described on the metabolism and the toxicological analysis of the amphetamine-derived designer drug 4-chloro-2,5-dimethoxyamphetamine (DOC) in rat urine using gas chromatographic-mass spectrometric techniques. The metabolites identified indicated that DOC was metabolized by O-demethylation at position 2 or 5 of the phenyl ring partly followed by glucuronidation and/or sulfation. The authors' systematic toxicological analysis procedure using full-scan gas chromatography-mass spectrometry after acid hydrolysis, liquid-liquid extraction and microwave-assisted acetylation allowed the detection of an intake of a dose of DOC in rat urine that corresponds to a common drug user's dose. Assuming similar metabolism, the STA procedure described should be suitable as proof of an intake of DOC in human urine.


Assuntos
2,5-Dimetoxi-4-Metilanfetamina/análogos & derivados , Cromatografia Gasosa-Espectrometria de Massas/métodos , Toxicologia/métodos , 2,5-Dimetoxi-4-Metilanfetamina/administração & dosagem , 2,5-Dimetoxi-4-Metilanfetamina/metabolismo , 2,5-Dimetoxi-4-Metilanfetamina/urina , Animais , Desenho de Fármacos , Masculino , Estrutura Molecular , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estereoisomerismo , Toxicologia/instrumentação
15.
J Chromatogr B Analyt Technol Biomed Life Sci ; 862(1-2): 252-6, 2008 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-18155651

RESUMO

The designer drug 2,5-dimethoxy-4-methyl-amphetamine (DOM, STP) is known to be extensively metabolized in various species. The current study showed that cytochrome P450 2D6 was the only isoenzyme involved in formation of the main metabolite hydroxy DOM. In addition, the authors' systematic toxicological analysis (STA) procedure using full-scan GC-MS was suitable to prove an intake of a common drug users' dose of DOM by detection of hydroxy DOM in rat urine. Assuming similar metabolism, the described STA procedure should be suitable for proof of an intake of DOM in human urine. However, DOM and/or other metabolites such as deamino-oxo-hydroxy DOM might be the target analyte in urine of CYP2D6 poor metabolizers.


Assuntos
Sistema Enzimático do Citocromo P-450/metabolismo , 2,5-Dimetoxi-4-Metilanfetamina/urina , Cromatografia Gasosa-Espectrometria de Massas/métodos , Isoenzimas/metabolismo , Detecção do Abuso de Substâncias/métodos , Animais , Ratos
16.
Artigo em Inglês | MEDLINE | ID: mdl-17632045

RESUMO

The amphetamine-derived designer drug 4-iodo-2,5-dimethoxy-amphetamine (DOI) is an upcoming substance on the illicit drug market. In the current study, the identification of its metabolites in rat urine and their toxicological detection in the authors' systematic toxicological analysis (STA) procedure were examined. DOI is extensively metabolized by O-demethylation and beside small amounts of parent compound it was found to be excreted mainly in form of metabolites. The STA procedure using full-scan GC-MS allowed proving an intake of a common drug users' dose of DOI by detection of the two O-demethyl metabolite isomers in rat urine. Assuming similar metabolism, the described STA procedure should be suitable for proof of an intake of DOI in human urine.


Assuntos
2,5-Dimetoxi-4-Metilanfetamina/análogos & derivados , 2,5-Dimetoxi-4-Metilanfetamina/urina , Drogas Desenhadas/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Detecção do Abuso de Substâncias/métodos , Urinálise/métodos , 2,5-Dimetoxi-4-Metilanfetamina/toxicidade , Animais , Masculino , Redes e Vias Metabólicas , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Extração em Fase Sólida , Manejo de Espécimes
17.
J Mass Spectrom ; 41(9): 1140-8, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16810708

RESUMO

Studies are described on the metabolism and the toxicological detection of the amphetamine-derived designer drug 2,4,5-trimethoxyamphetamine (TMA-2) in rat urine using gas chromatographic/mass spectrometric (GC/MS) techniques. The identified metabolites indicated that TMA-2 was metabolized by oxidative deamination to the corresponding ketone followed by reduction to the corresponding alcohol, O-demethylation followed by oxidative deamination, and finally O,O-bis-demethylation. All metabolites carrying hydroxy groups were found to be partly excreted in urine as glucuronides and/or sulfates. The authors' systematic toxicological analysis (STA) procedure using full-scan GC/MS after acid hydrolysis, liquid-liquid extraction, and microwave-assisted acetylation allowed the detection, in rat urine, of an intake of TMA-2 that corresponds to a common drug users' dose. Assuming similar metabolism, the described STA procedure in human urine should be suitable as proof of an intake of TMA-2.


Assuntos
Anfetaminas/metabolismo , Anfetaminas/urina , Drogas Desenhadas/análise , Anfetaminas/toxicidade , Animais , Biotransformação , Cromatografia Gasosa-Espectrometria de Massas , Masculino , Ratos , Ratos Wistar , Espectrometria de Massas por Ionização por Electrospray , Detecção do Abuso de Substâncias
18.
J Mass Spectrom ; 41(4): 487-98, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16470568

RESUMO

Studies are described on the metabolism and the toxicological analysis of the amphetamine-derived designer drug 2,5-dimethoxy-4-bromo-amphetamine (DOB) and its corresponding N-methyl analogue 2,5-dimethoxy-4-bromo-methamphetamine (MDOB) in rat urine using gas chromatographic/mass spectrometric techniques. The identified metabolites indicated that DOB was metabolized by O-demethylation followed by oxidative deamination to the corresponding ketone as well as deamination followed by reduction to the corresponding alcohol. Other metabolic pathways were O,O-bisdemethylation or hydroxylation of the side chain followed by O-demethylation and deamination to the corresponding alcohol. The expected oxo compound after deamination could not be detected. All metabolites carrying hydroxy groups were found to be partly excreted in the conjugated form. MDOB underwent O-demethylation, O,O-bisdemethylation, or hydroxylation of the side chain followed by O-demethylation. Additional N-demethylation to DOB occurred, including the above-mentioned metabolites. Again, all metabolites carrying hydroxy groups were found to be partly excreted in the conjugated form. The authors' systematic toxicological analysis (STA) procedure using full-scan GC/MS after acid hydrolysis, liquid-liquid extraction, and microwave-assisted acetylation allowed the detection of an intake of a dose of DOB and MDOB in rat urine that corresponds to a common drug user's dose. Assuming a similar metabolism, the described STA procedure in human urine should be suitable as proof of an intake of DOB and MDOB.


Assuntos
2,5-Dimetoxi-4-Metilanfetamina/análogos & derivados , Drogas Desenhadas/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Detecção do Abuso de Substâncias/métodos , Urinálise/métodos , 2,5-Dimetoxi-4-Metilanfetamina/urina , Animais , Masculino , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
J Chromatogr B Analyt Technol Biomed Life Sci ; 824(1-2): 123-31, 2005 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-16027051

RESUMO

4-Methylthioamphetamine (4-MTA) is a scheduled designer drug that has appeared on the illicit drug market and led to several non-fatal or even fatal poisonings. Only few data are available on its metabolism. The first aim of this study was to identify the 4-MTA metabolites in human urine and then to study whether the authors' STA procedure is suitable for screening for and identification of 4-MTA and/or its metabolites in urine. After enzymatic cleavage of conjugates, solid-phase extraction (SPE) and acetylation the following metabolites could be identified by full-scan gas chromatography-mass spectrometry (GC-MS): deamino-oxo 4-MTA, deamino-hydroxy 4-MTA, ring hydroxy and beta-hydroxy 4-MTA. 4-MTA sulfoxide could be identified as possible artifact. In urine samples after enzymatic hydrolysis, acidic extraction, and methylation, 4-methylthiobenzoic acid could be identified. The authors' systematical toxicological analysis (STA) procedure using full-scan GC-MS after acid hydrolysis, liquid-liquid extraction (LLE) and acetylation allowed detection of 4-MTA as target analyte plus all the above-mentioned metabolites with the exception of 4-methylthiobenzoic acid. The extraction efficiency of 4-MTA was approximately 70% and the limit of detection (LOD) was 30 ng/ml (S/N 3).


Assuntos
Anfetaminas/urina , Drogas Desenhadas/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Anfetaminas/metabolismo , Anfetaminas/intoxicação , Drogas Desenhadas/metabolismo , Drogas Desenhadas/intoxicação , Humanos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA