Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Mater Today Bio ; 22: 100761, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37600351

RESUMO

In severe peripheral nerve injuries, nerve conduits (NCs) are good alternatives to autografts/allografts; however, the results the available devices guarantee for are still not fully satisfactory. Herein, differently bioactivated NCs based on the new polymer oxidized polyvinyl alcohol (OxPVA) are compared in a rat model of sciatic nerve neurotmesis (gap: 5 mm; end point: 6 weeks). Thirty Sprague Dawley rats are randomized to 6 groups: Reverse Autograft (RA); Reaxon®; OxPVA; OxPVA + EAK (self-assembling peptide, mechanical incorporation); OxPVA + EAK-YIGSR (mechanical incorporation); OxPVA + Nerve Growth Factor (NGF) (adsorption). Preliminarily, all OxPVA-based devices are comparable with Reaxon® in Sciatic Functional Index score and gait analysis; moreover, all conduits sustain nerve regeneration (S100, ß-tubulin) without showing substantial inflammation (CD3, F4/80) evidences. Following morphometric analyses, OxPVA confirms its potential in PNI repair (comparable with Reaxon®) whereas OxPVA + EAK-YIGSR stands out for its myelinated axons total number and density, revealing promising in injury recovery and for future application in clinical practice.

2.
J Plast Surg Hand Surg ; 57(1-6): 471-475, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36546361

RESUMO

The Camper's chiasm (CC) originates from the decussation of tendon fibers of the flexor digitorum superficialis at the level of the proximal phalanx. Previous studies described several conformations of the CC, but none has studied the asymmetry pattern for each finger. We lack studies about the relationship between the vincula tendinum and the morphology of the CC. We aimed to study the precise pattern of asymmetry and the aforementioned relationship in a cadaveric study. We studied the fingers of 9 fresh frozen human hands (thumb excluded). We observed the distribution of the fibers and categorized each CC according to the Gonzalez classification. Finally, we recorded the inset point of the vincula longa superficiales (VLS) according to Schmidt. We found 7 symmetrical CCs, while the remaining 29 showed an asymmetrical pattern that matched with the site of insertion of the VLS. For the index and long fingers, we detected a dominance of the ulnar slip. For the ring and little finger, we found a higher radial dominance. The inset point of the VLS always coincided with the side of slip dominance, whereas in symmetrical CCs, the VLS was symmetrical as well. Since the vascular role of the vincula tendinum, we speculate that the asymmetry of the CC may be of vascular origin.


Assuntos
Dedos , Tendões , Humanos , Tendões/cirurgia , Dedos/cirurgia , Mãos , Músculo Esquelético , Cadáver
3.
Diagnostics (Basel) ; 12(3)2022 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-35328236

RESUMO

The abdominal microsurgical flap based on the deep inferior epigastric artery perforator (DIEP) flap has become the most popular option worldwide for autologous breast reconstruction. Several authors have investigated the results of reconstructed breasts, but the literature lacks systematic reviews exploring the donor site of the abdominal wall. To fulfil our aims, a new diagnostic muscle imaging analysis was designed and implemented. This study focused on rectus abdominal muscle morphology and function in a single series of 12 consecutive patients analysed before and after breast reconstruction with a microsurgical DIEP flap. Patients were divided into two groups, namely, "ipsilateral reconstruction" and "contralateral reconstruction", depending on the side of the flap harvest and breast reconstruction, then evaluated by computed tomography (CT) scans scheduled for tumor staging, and clinically examined by a physiatrist. Numerous alterations in muscle physiology were observed due to surgical dissection of perforator vessels, and rectus muscle distress without functional impairment was a common result. Postoperatively, patients undergoing "contralateral reconstruction" appeared to exhibit fewer rectus muscle alterations. Overall, only three patients were impacted by a long-term deterioration in their quality of life. On the basis of the newly developed and implemented diagnostic approach, we concluded that DIEP microsurgical breast reconstruction is a safe procedure without major complications at the donor site, even if long-term alterations of the rectus muscle are a common finding.

4.
Ann Ital Chir ; 102021 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-34569471

RESUMO

Complex injuries involving bones, tendons and soft tissues of the hand still represent a difficult challenge for reconstructive surgeons. Hereby, we present a case of a man suffering from a complex crush injury of the right hand that led to a wide three-dimensional defect with loss of two metacarpal bones, extensor tendons and skin. For composite hand defects, the most common surgical approach provides for a one-stage composite reconstruction or for an early restoration of bone and skin, with delayed tendon grafts. For the peculiarity of the defect, a one-stage reconstruction was not feasible. Hence, we opted for a two-stage reconstruction but the usual surgical steps have been inverted. First we secured tendon and skin restoration through a composite teno-cutaneous radial free flap. A month later, we reconstructed the two metacarpals with a modified Masquelet technique using fibular cortical graft. This strategy allowed the patient to start an early rehabilitation program and obtain a satisfactory recovery of his dominant hand. KEY WORDS: Composite flap, Hand trauma, Hand reconstruction, Microsurgery.


Assuntos
Retalhos de Tecido Biológico , Traumatismos da Mão , Procedimentos Ortopédicos , Procedimentos de Cirurgia Plástica , Traumatismos da Mão/cirurgia , Humanos , Masculino , Microcirurgia
6.
Sci Data ; 7(1): 60, 2020 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-32080198

RESUMO

Despite recent advances in prosthetics, many upper limb amputees still use prostheses with some reluctance. They often do not feel able to incorporate the artificial hand into their bodily self. Furthermore, prosthesis fitting is not usually tailored to accommodate the characteristics of an individual's phantom limb sensations. These are experienced by almost all persons with an acquired amputation and comprise the motor and postural properties of the lost limb. This article presents and validates a multimodal dataset including an extensive qualitative and quantitative assessment of phantom limb sensations in 15 transradial amputees, surface electromyography and accelerometry data of the forearm, and measurements of gaze behavior during exercises requiring pointing or repositioning of the forearm and the phantom hand. The data also include acquisitions from 29 able-bodied participants, matched for gender and age. Special emphasis was given to tracking the visuo-motor coupling between eye-hand/eye-phantom during these exercises.


Assuntos
Amputação Cirúrgica , Fixação Ocular , Mãos , Membro Fantasma/diagnóstico , Acelerometria , Amputados , Eletromiografia , Antebraço , Humanos
7.
Sci Data ; 7(1): 43, 2020 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-32041965

RESUMO

A hand amputation is a highly disabling event, having severe physical and psychological repercussions on a person's life. Despite extensive efforts devoted to restoring the missing functionality via dexterous myoelectric hand prostheses, natural and robust control usable in everyday life is still challenging. Novel techniques have been proposed to overcome the current limitations, among them the fusion of surface electromyography with other sources of contextual information. We present a dataset to investigate the inclusion of eye tracking and first person video to provide more stable intent recognition for prosthetic control. This multimodal dataset contains surface electromyography and accelerometry of the forearm, and gaze, first person video, and inertial measurements of the head recorded from 15 transradial amputees and 30 able-bodied subjects performing grasping tasks. Besides the intended application for upper-limb prosthetics, we also foresee uses for this dataset to study eye-hand coordination in the context of psychophysics, neuroscience, and assistive robotics.


Assuntos
Fixação Ocular , Mãos , Próteses e Implantes , Desenho de Prótese , Acelerometria , Amputação Cirúrgica , Amputados , Eletromiografia , Força da Mão , Humanos , Robótica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA