Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Ann Thorac Surg ; 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38750686

RESUMO

BACKGROUND: The aim of this study was to report the long-term results of the clover and edge-to-edge repair techniques for complex tricuspid regurgitation (TR). METHODS: This was a single-center observational study. A competing risks proportional-hazards regression model, using the Fine and Gray model, was performed to analyze the time to TR ≥2+, considering death as a competing risk. RESULTS: A total of 145 consecutive patients (57% female) with severe or moderately severe TR secondary to leaflet prolapse or flail (115 patients), tethering (27 patients), or mixed (3 patients) lesions underwent clover (110 patients) or edge-to-edge repair(35 patients). The TR origin was degenerative in 75% of cases, posttraumatic in 8%, and secondary to dilated cardiomyopathy in 17%. Ring (64%) or suture (31%) annuloplasty was performed in 95% of patients. Concomitant procedures (mainly mitral surgery) were performed in 80% of cases. Hospital death was 5.5%. Follow-up was 98% complete, and median was 15 years (interquartile range, 14-17 years). The 16-year overall survival was 56% ± 5%. Previous cardiac surgery (hazard ratio [HR], 2.83; 95% CI, 1.15-6.93; P = .023) and right ventricular dysfunction (HR, 2.24; 95% CI, 1.01-4.95; P = .046) were identified as predictors of death. The 16-year cumulative incidence function (CIF) of cardiac death with noncardiac death as a competing risk was 19.6%, and previous cardiac surgery (HR, 3.44; 95% CI, 1.23-9.65; P = .019) was detected as the only predictor of the event. At 16 years, the CIF of TR ≥2+ with death as a competing risk was 23.8%. In particular, TR ≥3+ was detected in 4 patients (3%). CONCLUSIONS: When TR could not be treated by annuloplasty alone, concomitant leaflet repair with the clover or edge-to-edge technique effectively restored valve competence with very satisfactory long-term results and a low rate of moderate or greater TR recurrence.

3.
JACC Case Rep ; 28: 102090, 2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-38204541

RESUMO

We report a case of patient with a single-chamber Hisian pacemaker who developed complete atrioventricular block and significant deterioration of the ventricular threshold and sensing after transcatheter aortic valve replacement. Revision of the implantation was required, with ventricular lead extraction and replacement.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA