Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Egypt Heart J ; 74(1): 69, 2022 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-36178602

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) is a standard treatment in patients with heart failure; however, approximately 20-40% of recipients of (CRT) do not respond to it based on the current patients' selection criteria. The purpose of this study was to identify the baseline parameters that predict the CRT response and how the ECG morphology can affect the outcome. The study aimed to evaluate the Strauss ECG criteria as a predictor of response in patients undergoing cardiac resynchronization therapy. RESULTS: Out of 70 patients, 3 patients missed the 6-month follow-up after CRT implantation, so the study enrolled 67 patients that have been classified according to ECG morphology of LBBB to 37 patients with non-Strauss ECG criteria-one of whom died after 4 months-and 30 patients with Strauss ECG criteria. The number of responders in the study was 50 patients with percentage 75.8%; 52% of CRT responder (26 patients) had non-Strauss ECG criteria, while 48% of CRT responders (24 patients) had Strauss ECG criteria with P value = 0.463. While there was no statistical significance of overall CRT response nor 6-month hospitalization and mortality between patients of Strauss and non-Strauss ECG criteria, there was a significant improvement in NYHA class, EF assessed by biplane Simpson's, end-systolic volume, global longitudinal strain and global circumferential strain by speckle tracking echocardiography in patients with Strauss ECG criteria of LBBB. CONCLUSIONS: There is no statistical significance in overall CRT response nor the 6-month hospitalization and mortality after 6 months of follow-up between patients with Strauss and non-Strauss ECG criteria of LBBB; however, patients with Strauss ECG criteria have better improvement in NYHA class, echocardiographic parameters such as EF and ESV and speckle tracking parameters (GLS and GCS).

2.
Herzschrittmacherther Elektrophysiol ; 33(3): 312-318, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35776180

RESUMO

BACKGROUND: Pacing is an effective treatment in the management of patients with bradyarrhythmias. Chronic right ventricular pacing may cause electrical and mechanical dyssynchrony leading to a deterioration of left ventricular ejection fraction (LVEF). This deterioration of LVEF has been described as pacing-induced cardiomyopathy (PICM). The incidence of PICM has been described by many studies, ranging between 10% and 26%. Predictors for PICM are not yet established-studies were limited by variations in the definition of PICM and the follow-up period. The authors studied the incidence and predictors of PICM in patients with preserved LVEF who underwent pacemaker implantation. PATIENTS AND METHODS: This retrospective study included 320 patients that underwent single- or dual-chamber pacemaker implantation, with a mean follow up period of 4.7 ± 2.0 years. Implantable cardioverter defibrillator and cardiac resynchronization therapy patients were excluded from this study. Individuals that had a baseline LVEF ≥ 50% before implantation in transthoracic echocardiography were included in the study. RESULTS: Of the 320 patients included in the study, 45% were male, with a mean age 55.5 years. The incidence of PICM was 7.5%. Wider native QRS duration, particularly > 140 ms (P < 0.001), wider paced QRS (pQRS) duration > 150 ms (P < 0.001), low normal ejection fraction < 56% pre-implantation (P = 0.023) and increased LV end diastolic diameter (LVEDD) > 53 mm and LV end systolic diameter (LVESD) > 38 mm (P < 0.001) predicted the development of PICM. There was no association between burden of right ventricular pacing (P = 0.782) or pacing site (P = 0.876) and the development of pacemaker-induced cardiomyopathy. CONCLUSION: Right ventricular pacing-induced left ventricular dysfunction is not uncommon, with an incidence of 7.5%. Wider native and paced QRS durations, low normal ejection fraction (< 56%) pre-implantation and increased LVEDD and LVESD post implantation are the most important predictors for the development of PICM.


Assuntos
Cardiomiopatias , Marca-Passo Artificial , Disfunção Ventricular Esquerda , Estimulação Cardíaca Artificial/efeitos adversos , Cardiomiopatias/diagnóstico , Cardiomiopatias/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/prevenção & controle , Função Ventricular Esquerda
3.
Reprod Sci ; 29(6): 1836-1843, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35359224

RESUMO

We aimed to find a correlation between the intraoperative diameters of the seminiferous tubules evaluated at high magnification during micro-testicular sperm extraction (micro-TESE) and total motile sperm count (TMSC) in non-obstructive azoospermic (NOA) patients. Five hundred four consecutive NOA patients were included and underwent micro-TESE. The change in the mean TMSC and different seminiferous tubular diameters was of high statistical significance (p < 0.001). It should be noted that the highest mean TMSC was reported in the dilated tubules (DTs) group followed by the other study groups 941.72 ± 196.97, 487.37 ± 443.57, and 34.54 ± 60.79, respectively. Furthermore, 21 naïve cases had dilated tubules (DTs) and 18 (85.7%) of them had shown eventful micro-TESE. Conversely, 186 naïve cases had slightly dilated tubules (SDTs), and 101 (54.3%) of them had eventful micro-TESE. Only 8 (24.25%) cases of the 33 cases had non dilated tubules (NDTs) and showed eventful micro-TESE. The frequency of intrasurgical seminiferous tubular diameter and micro-TESE outcome among the naïve cases had demonstrated a highly statistical significance (p < 0.001). Interestingly, all salvaged cases (100%) with DTs and a previous eventful TESE had shown eventful TESE in the current study. The most dilated intrasurgical seminiferous tubular diameter is associated with the highest TMSC in NOA patients including SCO cases.


Assuntos
Azoospermia , Azoospermia/cirurgia , Humanos , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Contagem de Espermatozoides , Recuperação Espermática , Espermatozoides , Testículo
4.
Herzschrittmacherther Elektrophysiol ; 33(2): 209-216, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35258692

RESUMO

BACKGROUND: Inflammation plays an important role in the pathogenesis of atrial fibrillation (AF). Vitamin D deficiency has been found to increase vulnerability to AF. The authors aimed to determine the relationship between vitamin D deficiency and cardioversion success in AF patients. METHODS: The study included 200 persistent AF patients presenting for cardioversion. Serum vitamin D level was sampled on admission. The success of cardioversion was assessed and patients divided into two groups: successful or failed (group I and II, respectively). Vitamin D level was assessed and patients were divided into three groups: deficient, insufficient, and sufficient vitamin D level. Cardioversion was performed pharmacologically or electrically. Failure of cardioversion was defined as: (1) detection of AF rhythm in 12-lead ECG recording immediately after cardioversion or within 6­month follow-up, or (2) ECG Holter monitoring of AF lasting > 30 s at 6­month follow-up. RESULTS: There was a highly statistically significant difference in baseline serum vitamin D level between group I and group II (P-value < 0.01). There were no statistically significant differences between the three groups in terms of vitamin D levels regarding age, gender, body mass index, smoking, and left atrial diameter. CONCLUSION: This study demonstrated that AF cardioversion failure was associated with vitamin D deficiency in patients without structural heart disease, while sufficient and insufficient vitamin D levels were associated with successful cardioversion. Therefore, vitamin D level assessment before cardioversion may help predict the success of cardioversion, and possible correction of deficient vitamin D levels may increase the chance of successful cardioversion.


Assuntos
Fibrilação Atrial , Deficiência de Vitamina D , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Cardioversão Elétrica , Humanos , Resultado do Tratamento , Vitamina D , Deficiência de Vitamina D/complicações , Deficiência de Vitamina D/diagnóstico
5.
J Matern Fetal Neonatal Med ; 35(25): 4910-4917, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33645399

RESUMO

PURPOSE: This work investigates ICSI outcome between LASER Artificial Shrinkage (LAS) and Micro-Needle Artificial Shrinkage (MNAS) before vitrification. PATIENTS AND METHODS: Four hundred and nine women were included in the study; which were randomly divided into two groups according to the technique used for artificial shrinkage step of the blastocyst before vitrification: in the first group, Laser beam was used while in the second group the micro-needle was used. Ovarian stimulation was done before the ICSI procedure either by long, short or antagonist protocol. RESULTS: The statistical analysis of our study revealed that there was no statistically significant difference between the two groups regarding age, number of cases, AMH, Basal FSH, BMI, male factor, usage ovarian stimulation protocol, high quality blastocysts, the mean number of transferred embryos. While, there was a statistically significant difference between two groups after thawing with p-value < .001 in favor of the LAS method regarding the morphology of originally high quality blastocysts, blastocysts healthiness (not degenerated), pregnancy rate, the implantation rates. CONCLUSION: LASER artificial shrinkage of human blastocysts is a promising technology that could be implemented on a wider basis to improve ART practice, as our study revealed that the usage of LASER pulse for artificial shrinkage of blastocysts before vitrification has better implantation rate as well as better chemical and clinical pregnancy rate in comparison to the usage of micro-needle artificial shrinkage of blastocysts before vitrification. There is a statistically significant difference regarding live birth rate being more in the LASER group as compared to needle group, also the number of twins ether identical or non-identical are larger in laser group than in needle group but with no statistically significant difference. Clinical trials.gov ID: NCT04125017.


Assuntos
Aborto Espontâneo , Vitrificação , Gravidez , Masculino , Feminino , Humanos , Coeficiente de Natalidade , Injeções de Esperma Intracitoplásmicas , Criopreservação/métodos , Blastocisto/fisiologia , Taxa de Gravidez , Lasers
6.
Arab J Urol ; 19(3): 247-254, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34552776

RESUMO

OBJECTIVE: : To review the debate about the routine use of cryopreserved testicular sperm for intracytoplasmic sperm injection (ICSI) from patients with non-obstructive azoospermia (NOA), as some authors suggest repeating sperm retrieval in such cases due to poorer ICSI results when frozen-thawed testicular sperm is used compared with fresh sperm. METHODS: : A systematic literature review was performed in August 2020 using the Medical Literature Analysis and Retrieval System Online (MEDLINE), Web of Science databases and the Excerpta Medica dataBASE (EMBASE), and we included 26 studies that were considered eligible for this systematic review. RESULTS: : In all, 1189 publications were screened and 26 articles were included in the systematic review. Three meta-analysis reviews were included and they all concluded that the use of fresh and frozen sperms for ICSI from patients with NOA showed comparable fertilisation and pregnancy rates. CONCLUSION: : The use of frozen testicular sperm from men with NOA results in fertilisation and clinical pregnancy rates similar to those of fresh sperm. This may encourage fertility centres to use frozen testicular sperm samples, as this policy has certain advantages that would help with organising their workflow.Abbreviations: CPR: clinical pregnancy rate; 2PN%: two pronuclei % fertilisation rate; ICSI: intracytoplasmic sperm injection; NOA: non-obstructive azoospermia; OA, obstructive azoospermia; SCO: Sertoli cell-only syndrome; (micro-)TESE: (microsurgical) testicular sperm extraction.

7.
Herzschrittmacherther Elektrophysiol ; 32(3): 341-345, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34255142

RESUMO

BACKGROUND: Many electrocardiography (ECG) criteria have been proposed for the localization of outflow tract premature ventricular contractions (PVCs); however, in some cases, it is difficult to accurately localize the origin of PVCs using the surface ECG. The authors aimed to study the QRS-right ventricular apex (RVA) interval measured during electrophysiological study and its role in the differentiation between different sites of origin of outflow tract PVCs. METHODS: The study included 90 patients (81 females, mean age 37.20 ± 7.87) referred for outflow tract PVC ablation. The authors measured the interval from the onset of the earliest QRS complex of the PVCs to the distal RVA intracardiac signal (the QRS-RVA interval) during the electrophysiological study and correlated this interval with the origin of outflow tract PVCs as identified by successful ablation during the procedure. RESULTS: The QRS-RVA interval was significantly longer in PVCs originating from the left ventricular outflow tract (LVOT) compared to the right ventricular outflow tract (RVOT) (67.33 ± 7.56 for LVOT PVCs vs. 37.11 ± 4.34 for RVOT PVCs, p < 0.001). Receiver operating characteristic (ROC) analysis showed that a QRS-RVA interval ≥ 48 ms predicted an LVOT origin of PVCs. A shorter interval was noted in PVCs originating from the RVOT free wall rather than the septal RVOT wall, and a shorter interval was also noted in LVOT PVCs originating from the right coronary cusp as compared to other LVOT PVCs, although these differences did not reach statistical significance. CONCLUSION: Measuring the QRS-RVA interval is a simple and accurate method for differentiating the origin of outflow tract PVCs during an electrophysiological study. A QRS-RVA interval ≥ 48 ms predicts an LVOT origin of PVCs rather than an RVOT origin.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Adulto , Eletrocardiografia , Feminino , Coração , Ventrículos do Coração , Humanos , Pessoa de Meia-Idade , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
8.
Herzschrittmacherther Elektrophysiol ; 32(1): 54-61, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33108510

RESUMO

BACKGROUND: Cardiac implantable electronic devices have been increasingly used in recent years; as a result, there has been a rise in device-related complications. Pacemaker-associated infection is challenging to manage, including system removal, antimicrobial therapy and reimplantation at another site. The aim of this study was to evaluate adherence to the steps in an infection control protocol in cardiac device implantation. RESULTS: A total of 100 patients referred for cardiac device implantation were enrolled in the study. They were evaluated with regard to the application of infection control measures during device implantation and followed-up for 6 months to detect clinical signs of device-related infection (DRI). A significant correlation was found between the development of postoperative DRI and the presence or absence of the following factors: increasing patient age (p = 0.010), diabetes mellitus (p = 0.024), number of operators ≥4 (p = 0.001), implantation of a biventricular system (p = 0.025), duration of sterilization (p = 0.001), wearing double gloves (p < 0.001) and postoperative hematoma (p = 0.021). CONCLUSIONS: The study identified the following risk factors for DRI: age, diabetes mellitus and cardiac resynchronization therapy system implantation (p = 0.025). Antiseptic measures such as double-glove technique and duration of skin disinfection prior to the procedure, as well as environmental factors, also influenced device infection, as did the number of operators/staff and pocket hematoma.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Humanos , Controle de Infecções , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/prevenção & controle , Fatores de Risco
9.
Hum Fertil (Camb) ; 24(5): 389-394, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31838927

RESUMO

This study aimed to demonstrate the effect of conventional freezing versus cryoprotectant-free vitrification on the recovery of testicular sperm motility. Testicular samples were obtained from 50 patients with azoospermia for testicular biopsy ± potential sperm storage. We retrieved 100 spermatozoa from each patient divided equally into two straws. They were frozen using conventional freezing as a control group and cryoprotectant-free vitrification in micro-capillary system using open-pulled straws. Seven days later, cryopreserved straws were thawed and assessed in duplicate. The mean sperm motility between the original spermatozoa sample and the post warming sample was reduced after conventional freezing compared to cryoprotectant-free vitrification (4.48 ± 2.09% versus 3.25 ± 1.92%, p < 0.001; 4.48 ± 2.09% vs 3.68 ± 1.93%, p < 0.001, respectively). There was a significant difference between the two methods regarding the mean sperm motility after warming (3.38 ± 1.86% versus 3.76 ± 1.88%, p = 0.015). The mean recovery percent of testicular sperm motility from the original sperm sample was lower (p = 0.02) after conventional freezing compared to cryoprotectant-free vitrification (78.4 ± 28.17% versus 85.37 ± 23.63%). Overall, the rate of post-thaw recovery of human testicular sperm motility improved using cryoprotectant-free vitrification compared to conventional freezing.


Assuntos
Preservação do Sêmen , Vitrificação , Criopreservação , Congelamento , Humanos , Masculino , Estudos Prospectivos , Motilidade dos Espermatozoides , Espermatozoides
10.
Fertil Steril ; 89(3): 592-6, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17517404

RESUMO

OBJECTIVE: The aim of this study was to measure the diameter of seminiferous tubules (ST) during microdissection testicular sperm extraction (TESE) using a micrometer fixed to one of the eyepieces of the operating microscope to find a correlation between the extracted ST diameter and TESE outcome. DESIGN: A prospective comparative study. SETTING: Adam International Andrology and Infertility Clinic, Giza, Egypt. PATIENT(S): Two hundred sixty-four patients with nonobstructive azoospermia (NOA) were included. INTERVENTION(S): Patients underwent TESE using the open surgical technique. The STs were measured using the micrometer, and the tubule with the largest diameter was excised and freshly examined under an inverted microscope. If no spermatozoa were found, another sample was taken from the second most dilated tubule area and then at random until sperm were found or a maximum six samples were harvested. If no spermatozoa were detected, the contralateral testis was operated upon. MAIN OUTCOME MEASURE(S): The TESE outcome in relation to ST diameter. RESULT(S): The total sperm recovery rate was 105 out of 264 (39.8%). When ST measured >or=300 microm the sperm retrieval rate was 16 out of 19 (84.2%). When ST diameter was <300 microm, the sperm retrieval rate was 36.3% (89 out of 245). CONCLUSION(S): During microdissection TESE, the best cutoff level of the ST diameter for harvesting testicular spermatoza is 110 microm with sensitivity 86.0% and specificity 74.4% (AUC 0.653, 95% confidence interval 0.608-0.663). When ST diameter is 300 microm or more a single tubule biopsy is usually sufficient to harvest enough testicular spermatozoa for intracytoplasmic sperm injection or sperm freezing with minimal tissue excision.


Assuntos
Azoospermia/terapia , Biópsia/métodos , Microcirurgia , Túbulos Seminíferos/cirurgia , Recuperação Espermática , Adulto , Azoospermia/patologia , Criopreservação , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Preservação do Sêmen , Túbulos Seminíferos/patologia , Sensibilidade e Especificidade , Injeções de Esperma Intracitoplásmicas , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA