Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Optom Vis Sci ; 101(4): 195-203, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38684062

RESUMO

SIGNIFICANCE: Spatio-Temporal Optical Phase technology utilizes film pairs containing optical elements applied to standard single-vision spectacle lenses. This technology provides a dynamic optical cue that may have efficacy in reducing the rate of myopia progression, but the visual performance of this technology is unknown. PURPOSE: This study aimed to assess the visual performance of film pairs containing optical elements (tests) and a film pair with no optical elements (control). METHODS: In this randomized, single-masked, bilateral wear study, 42 participants aged 18 to 40 years wore four test designs (E, F-1, G, and F-2) and the control. Subjective data (subjective ratings [1 to 10 scale]: clarity of vision [far-away, intermediate, near] and vision [at night, while walking, overall satisfaction], and willingness to purchase [yes/no response]) were collected after 3 days. Visual acuity (VA)-based measures (monocular high/low-contrast VA [6 m], contrast sensitivity [6 m], and binocular high-contrast VA [6 m and 40 cm]) were collected at dispensing. Visual acuity-based measures were also collected while wearing spectacles with no film. Analyses were performed using linear mixed models and the χ2 test. Significance was set at 5%. RESULTS: The control performed better than any test for all subjective ratings (mean differences, 1.6 to 3.1 units: p<0.001), willingness to purchase (p<0.001), and designs F-1 and F-2 for binocular high-contrast VA at 40 cm (p=0.001 and p=0.01, respectively). Clarity of vision was significantly worse with F-2 compared with F-1 and G (p<0.001 and p=0.02, respectively). There were no differences between tests for any other subjective rating (p>0.1), willingness to purchase (p=0.11), or any VA-based measure (p>0.08). There were no differences between control and spectacles with no film for any VA-based measure (p>0.08). CONCLUSIONS: All four test film pairs reduced visual performance compared with control to a degree comparable with other myopia management devices. There was no difference in visual performance between three of the four test film pairs.


Assuntos
Óculos , Acuidade Visual , Humanos , Adulto , Acuidade Visual/fisiologia , Adulto Jovem , Feminino , Masculino , Adolescente , Sensibilidades de Contraste/fisiologia , Miopia/fisiopatologia , Miopia/terapia , Método Simples-Cego , Visão Binocular/fisiologia , Desenho de Equipamento , Refração Ocular/fisiologia
2.
Eye Contact Lens ; 49(2): 63-70, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36282205

RESUMO

OBJECTIVES: The objective of this study was to compare the visual performance and binocular/accommodative function of two novel S.T.O.P. design (F2 and DT) contact lenses against MiSight when worn by myopic, young adults. METHOD: This was a prospective, randomized, cross-over, single-masked study. Each lens was worn daily wear with overnight peroxide disinfection for approximately 7 days. Visual performance was assessed with subjective ratings (0-100): clarity of vision and lack of ghosting (far away, intermediate, and near), vision when driving, overall vision satisfaction, and with monocular high-contrast and low-contrast visual acuity (HCVA/LCVA) at 6 m, binocular HCVA (6 m, 70 cm, 50 cm, and 40 cm), binocular LCVA (6 m and 70 cm). Binocular function was assessed with heterophorias (3 m and 40 cm). Accommodative function was assessed with monocular accommodative facility (AF: 40 cm) and dynamic monocular accommodative response (AR: 6 m, 70 cm, and 40 cm). RESULTS: F2 was rated higher than MiSight for clarity of vision (near and intermediate) and lack-of-ghosting ( P <0.001), while MiSight was rated higher than DT for clarity of vision (near, P <0.001). MiSight was better than F2 and DT for monocular HCVA (6 m) and binocular HCVA (6 m and 40 cm, P ≤0.02), but the maximum difference was ≤2 letters. There were no differences between designs for heterophoria ( P =0.61) nor were there any differences between DT and MiSight for any accommodative measure ( P >0.1). F2 was higher for monocular-AF ( P =0.007) and lower for AR (70 cm and 40 cm; P ≤0.007) compared with MiSight. CONCLUSIONS: The visual performance and binocular/accommodative function of S.T.O.P. designs F2 and DT were comparable with MiSight. F2 outperformed MiSight in some aspects of subjective visual performance and monocular accommodative function.


Assuntos
Lentes de Contato Hidrofílicas , Presbiopia , Adulto Jovem , Humanos , Acuidade Visual , Estudos Prospectivos , Acomodação Ocular , Visão Binocular/fisiologia
3.
J Optom ; 9(1): 5-12, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26190684

RESUMO

PURPOSE: To determine if a fogging lens ameliorates accommodative effects driven by the closed-view design of the BHVI-EyeMapper (EM) instrument. We compared cycloplegic refraction and higher-order aberration measurements of the EM with those obtained with a fogging lens. METHODS: Twenty-six, young, participants (15F, 25±5 years, range: 18-35 years, SE: +0.25 D and -3.50 D) with good ocular health were recruited. Five independent measurements of on- and off-axis refraction and higher-order aberrations were recorded across the horizontal visual field, under two conditions: non-cycloplegic measurements with +1.00 D fogging lens and cycloplegia, always in the same sequence. The contralateral eye was occluded during the measurements. Two drops of 1% Tropicamide delivered within 5 min facilitated cycloplegic measurements. All participants were refracted 30 min after installation of the second drop. RESULTS: Mean spherical equivalent measures of the non-cycloplegic condition were significantly more myopic than their cycloplegic counterparts (p<0.05); approximately by 0.50 D centrally, increasing to 1.00 D towards the periphery. The horizontal astigmatic component, J180, demonstrated small but statistically significant differences between the test conditions. Differences were predominant for eccentricities greater than 30°, in both nasal and temporal meridians. The oblique astigmatic component, J45, was not significantly different between the test conditions. The primary spherical aberration coefficient C(4, 0) was significantly less positive for the non-cycloplegic state than its cycloplegic counterpart. This result held true across the entire horizontal visual field. The horizontal coma and trefoil coefficients C(3, 1) and C(3, 3) were not significantly different between the two conditions. CONCLUSIONS: The use of +1.00 D fogging lens without cycloplegia did not provide complete relaxation of accommodation. The discrepancies between cycloplegic and non-cycloplegic EM measurements were found to be more pronounced for peripheral field angles than central measures, for both M and J180 components.


Assuntos
Acomodação Ocular/fisiologia , Refração Ocular/fisiologia , Privação Sensorial/fisiologia , Campos Visuais/fisiologia , Acomodação Ocular/efeitos dos fármacos , Adulto , Óculos , Feminino , Humanos , Masculino , Midriáticos/farmacologia , Refração Ocular/efeitos dos fármacos , Tropicamida/farmacologia , Campos Visuais/efeitos dos fármacos , Adulto Jovem
4.
Optom Vis Sci ; 91(10): 1199-207, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25105690

RESUMO

PURPOSE: The aim of this article was to present the optical design of a new instrument (BHVI-EyeMapper, EM), which is dedicated to rapid peripheral wavefront measurements across the visual field for distance and near, and to compare the peripheral refraction and higher-order aberration profiles obtained in myopic eyes with and without accommodation. METHODS: Central and peripheral refractive errors (M, J180, and J45) and higher-order aberrations (C[3, 1], C[3, 3], and C[4, 0]) were measured in 26 myopic participants (mean [±SD] age, 20.9 [±2.0] years; mean [±SD] spherical equivalent, -3.00 [±0.90] diopters [D]) corrected for distance. Measurements were performed along the horizontal visual field with (-2.00 to -5.00 D) and without (+1.00 D fogging) accommodation. Changes as a function of accommodation were compared using tilt and curvature coefficients of peripheral refraction and aberration profiles. RESULTS: As accommodation increased, the relative peripheral refraction profiles of M and J180 became significantly (p < 0.05) more negative and the profile of M became significantly (p < 0.05) more asymmetric. No significant differences were found for the J45 profiles (p > 0.05). The peripheral aberration profiles of C[3, 1], C[3, 3], and C[4, 0] became significantly (p < 0.05) less asymmetric as accommodation increased, but no differences were found in the curvature. CONCLUSIONS: The current study showed that significant changes in peripheral refraction and higher-order aberration profiles occurred during accommodation in myopic eyes. With its extended measurement capabilities, that is, permitting rapid peripheral refraction and higher-order aberration measurements up to visual field angles of ±50 degrees for distance and near (up to -5.00 D), the EM is a new advanced instrument that may provide additional insights in the ongoing quest to understand and monitor myopia development.


Assuntos
Aberrometria/instrumentação , Aberrações de Frente de Onda da Córnea/diagnóstico , Miopia/diagnóstico , Refração Ocular/fisiologia , Aberrometria/métodos , Acomodação Ocular/fisiologia , Aberrações de Frente de Onda da Córnea/fisiopatologia , Desenho de Equipamento , Feminino , Humanos , Masculino , Miopia/fisiopatologia , Testes Visuais , Campos Visuais , Adulto Jovem
5.
Optom Vis Sci ; 89(8): 1107-18, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22820470

RESUMO

PURPOSE: A physical model eye capable of carrying soft contact lenses (CLs) was used as a platform to evaluate optical performance of several commercial multifocals (MFCLs) with high- and low-add powers and a single-vision control. METHODS: Optical performance was evaluated at three pupil sizes, six target vergences, and five CL-correcting positions using a spatially filtered monochromatic (632.8 nm) light source. The various target vergences were achieved by using negative trial lenses. A photosensor in the retinal plane recorded the image point-spread that enabled the computation of visual Strehl ratios. The centration of CLs was monitored by an additional integrated en face camera. Hydration of the correcting lens was maintained using a humidity chamber and repeated instillations of rewetting saline drops. RESULTS: All the MFCLs reduced performance for distance but considerably improved performance along the range of distance to near target vergences, relative to the single-vision CL. Performance was dependent on add power, design, pupil, and centration of the correcting CLs. Proclear (D) design produced good performance for intermediate vision, whereas Proclear (N) design performed well at near vision (p < 0.05). AirOptix design exhibited good performance for distance and intermediate vision. PureVision design showed improved performance across the test vergences, but only for pupils ≥4 mm in diameter. Performance of Acuvue bifocal was comparable with other MFCLs, but only for pupils >4 mm in diameter. Acuvue Oasys bifocal produced performance comparable with single-vision CL for most vergences. CONCLUSIONS: Direct measurement of single-pass images at the retinal plane of a physical model eye used in conjunction with various MFCLs is demonstrated. This method may have utility in evaluating the relative effectiveness of commercial and prototype designs.


Assuntos
Lentes de Contato Hidrofílicas/normas , Refração Ocular/fisiologia , Erros de Refração/terapia , Desenho de Equipamento , Humanos , Erros de Refração/fisiopatologia , Reprodutibilidade dos Testes
6.
Opt Express ; 18(16): 16868-82, 2010 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-20721079

RESUMO

A bench-top physical model eye that closely replicates both anatomical and optical properties of an average human eye was designed and constructed. The cornea was sourced from a flouro-polymer with refractive index (RI) of 1.376 and crystalline lenses were made of Boston RGP polymers, EO and Equalens II, with an equivalent RI of 1.429 and 1.423 respectively. These materials served to make crystalline lens components of different age groups and accommodative states. De-Ionized water, with RI of 1.334 represented both aqueous and vitreous humor. The complementary metal-oxide sensor of a PixelLink digital camera with a resolution of 5MP and a 2.2 microm pixel pitch, hosted on a motor-base, served as the 'acting' retina. The translation and rotary functions of the motor-base facilitated the simulation of different states of ametropia and assessment of peripheral visual function, respectively. We validated one of its configurations to suit normal viewing conditions and results from the on and off-axis optical quality measurements are presented. As a demonstration of potential practical uses, several corrective soft contact lenses were placed on the model eye and their optical performance evaluated.


Assuntos
Lentes de Contato Hidrofílicas , Modelos Biológicos , Refração Ocular/fisiologia , Erros de Refração/fisiopatologia , Adulto , Humanos , Pessoa de Meia-Idade , Erros de Refração/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA