Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
EuroIntervention ; 20(3): e207-e215, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38343369

RESUMO

BACKGROUND: Outcomes after percutaneous coronary intervention (PCI) for de novo ostial right coronary artery (RCA) lesions are poor. AIMS: We used intravascular ultrasound (IVUS) to clarify the morphological patterns of de novo ostial RCA lesions and their associated clinical outcome. METHODS: Among 5,102 RCA IVUS studies, 170 de novo ostial RCA stenoses (within 3 mm from the aorto-ostium) were identified. These were classified as 1) isolated ostial lesions (no disease extending beyond 10 mm from the ostium and without a calcified nodule [CN]); 2) ostial CN, typically with diffuse disease (disease extending beyond 10 mm); and 3) ostial lesions with diffuse disease but without a CN. The primary outcome was target lesion failure (TLF: cardiac death, target vessel myocardial infarction, definite stent thrombosis, and ischaemia-driven target lesion revascularisation). RESULTS: The prevalence of an isolated ostial lesion was 11.8% (n=20), 47.6% (n=81) were ostial CN, and 40.6% (n=69) were ostial lesions with diffuse disease. Compared to ostial lesions with diffuse disease, isolated lesions were more common in women (75.0% vs 42.0%; p=0.01), and CN were associated with older age (median [first, third quartile] 76 [70, 83] vs 69 [63, 81] years old; p=0.002). The Kaplan-Meier rate of TLF at 2 years was significantly higher in patients with CN (21.6%) compared to diffuse lesions (8.2%) (p=0.04), and patients with isolated lesions had no events. A multivariable Cox proportional hazard model revealed that CN were significantly associated with TLF (hazard ratio 6.63, 95% confidence interval: 1.28-34.3; p=0.02). CONCLUSIONS: Ostial RCA lesions have specific morphologies - detectable by IVUS - that may be associated with long-term clinical outcomes.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Feminino , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Fatores de Risco , Angiografia Coronária
2.
JACC Cardiovasc Interv ; 17(4): 491-501, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38340105

RESUMO

BACKGROUND: Intravascular ultrasound (IVUS) studies show that one-quarter of left anterior descending (LAD) arteries have a myocardial bridge. An MB may be associated with stent failure when the stent extends into the MB. OBJECTIVES: The aim of this study was to investigate: 1) the association between an MB and chronic total occlusion (CTO) in any LAD lesions; and 2) the association between an MB and subsequent clinical outcomes after percutaneous coronary intervention in LAD CTOs. METHODS: A total of 3,342 LAD lesions with IVUS-guided percutaneous coronary intervention (280 CTO and 3,062 non-CTO lesions) were included. The primary outcome was target lesion failure (cardiac death, target vessel myocardial infarction, definite stent thrombosis, and ischemic-driven target lesion revascularization). RESULTS: An MB by IVUS was significantly more prevalent in LAD CTOs than LAD non-CTOs (40.4% [113/280] vs 25.8% [789/3,062]; P < 0.0001). The discrepancy in CTO length between angiography and IVUS was greater in 113 LAD CTOs with an MB than 167 LAD CTOs without an MB (6.0 [Q1, Q3: 0.1, 12.2] mm vs 0.2 [Q1, Q3: -1.4, 8.4] mm; P < 0.0001). Overall, 48.7% (55/113) of LAD CTOs had a stent that extended into an MB after which target lesion failure was significantly higher compared to a stent that did not extend into an MB (26.3% vs 0%; P = 0.0004) or compared to an LAD CTO without an MB (26.3% vs 9.6%; P = 0.02). CONCLUSIONS: An MB was more common in LAD CTO than non-CTO LAD lesions. If present, approximately one-half of LAD CTOs had a stent extending into an MB that, in turn, was associated with worse outcomes.


Assuntos
Oclusão Coronária , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Angiografia Coronária , Doença Crônica
4.
EuroIntervention ; 19(5): e383-e393, 2023 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-37283548

RESUMO

BACKGROUND: Despite a high rate of in-stent restenosis (ISR) after stenting the right coronary artery (RCA) ostium, the mechanism of ostial RCA ISR is not well understood. AIMS: We aimed to clarify the cause of ostial RCA ISR using intravascular ultrasound (IVUS). METHODS: Overall, 139 ostial RCA ISR lesions were identified with IVUS, pre-revascularisation. Primary ISR mechanisms were classified as follows: 1) neointimal hyperplasia (NIH); 2) neoatherosclerosis; 3) ostium not covered by the stent; 4) stent fracture or deformation; 5) stent underexpansion (old minimum stent area <4.0 mm2 or stent expansion <50%); or 6) a protruding calcified nodule. RESULTS: The median duration from prior stenting was 1.2 (first quartile 0.6, third quartile 3.1) years. The primary mechanisms of ISR were NIH in 25% (n=35) of lesions, neoatherosclerosis in 22% (n=30), uncovered ostium in 6% (n=9) (biological cause 53%, n=74), stent fracture or deformation in 25% (n=35), underexpansion in 11% (n=15), and protruding calcified nodules in 11% (n=15) (mechanical cause 47%, n=65). Including secondary mechanisms, 51% (n=71) of ostial RCA ISRs had stent fractures that were associated with greater hinge motion of the ostial-aorta angle during the cardiac cycle. The Kaplan-Meier rate of target lesion failure at 1 year was 11.5%. When the mechanically caused ISRs were treated without new stents, they suffered a higher subsequent event rate (41.4%) compared with non-mechanical causes or mechanical causes treated without restenting (7.8%, unadjusted hazard ratio 6.44, 95% confidence interval: 2.33-17.78; p<0.0001). CONCLUSIONS: Half of the ostial RCA ISRs were due to mechanical causes. Subsequent event rates were high, especially in mechanically caused ISRs treated without the implantation of a new stent.


Assuntos
Reestenose Coronária , Humanos , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Angiografia Coronária/efeitos adversos , Resultado do Tratamento , Stents/efeitos adversos
5.
JACC Cardiovasc Interv ; 15(21): 2206-2217, 2022 11 14.
Artigo em Inglês | MEDLINE | ID: mdl-36357025

RESUMO

BACKGROUND: Although the presence of severe stenosis in the left main coronary artery (LMCA) is a well-established predictor of mortality, whether this extends to nonobstructive atherosclerosis in the LMCA is unknown. OBJECTIVES: The aim of this study was to evaluate the association between LMCA disease by intravascular ultrasound (IVUS) and long-term mortality. METHODS: Between 2005 and 2013, 3,239 patients with LMCA IVUS imaging without LMCA revascularization (either before angiography or scheduled based on index angiography or IVUS) were included. The primary and secondary endpoints were all-cause and cardiac mortality at a minimum of 5 years obtained from the National Death Index. RESULTS: The IVUS-measured LMCA minimum lumen area (MLA) and plaque burden were 13.1 ± 5.0 mm2 and 41.7% ± 15.6%, respectively. The median follow-up was 8.2 years. The Kaplan-Meier estimated 12-year all-cause and cardiac death rates were 37.5% and 17.0%, respectively. Greater plaque burden (unadjusted HR per 10%: 1.17; 95% CI: 1.12-1.22; P < 0.0001) and smaller IVUS MLA (unadjusted HR per 1 mm2: 0.98; 95% CI: 0.96-0.99; P = 0.0008) were associated with all-cause death. After adjusting for clinical, angiographic, and IVUS factors, plaque burden (adjusted HR per 10%: 1.12; 95% CI: 1.04-1.21; P = 0.003) but not MLA (adjusted HR per 1 mm2: 1.02; 95% CI: 0.99-1.04; P = 0.18) was associated with long-term all-cause death. These findings were also consistent for long-term cardiac mortality. CONCLUSIONS: In the present large-scale study with a 12-year follow-up, increasing LMCA plaque burden was associated with long-term all-cause and cardiac mortality in patients not undergoing LMCA revascularization, even when the lumen area was preserved.


Assuntos
Aterosclerose , Doença da Artéria Coronariana , Placa Aterosclerótica , Humanos , Vasos Coronários/diagnóstico por imagem , Angiografia Coronária/métodos , Ultrassonografia de Intervenção/métodos , Resultado do Tratamento , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia
6.
Circ Cardiovasc Interv ; 15(9): e011693, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36126137

RESUMO

BACKGROUND: Clinical and morphological factors associated with lipidic versus calcified neoatherosclerosis within second-generation drug-eluting stents and the impact of lipidic versus calcified neoatherosclerosis on long-term outcomes after repeat intervention have not been well studied. METHODS: A total of 512 patients undergoing optical coherence tomography before percutaneous coronary intervention for second-generation drug-eluting stents in-stent restenosis were included. Neoatherosclerosis was defined as lipidic or calcified neointimal hyperplasia in ≥3 consecutive frames or ruptured lipidic neointimal hyperplasia. The primary outcome was target lesion failure (cardiac death, target vessel myocardial infarction, definite stent thrombosis, or clinically driven target lesion revascularization). RESULTS: The overall prevalence of neoatherosclerosis was 28.5% (146/512): 56.8% lipidic, 30.8% calcified, and 12.3% both lipidic and calcific. The prevalence increased as a function of time from stent implantation: 20% at 1 to 3 years, 30% at 3 to 7 years, and 75% >7 years. Renal insufficiency, poor lipid profile, and time from stent implantation were associated with lipidic neoatherosclerosis, whereas severe renal insufficiency, female sex, and time from stent implantation were associated with calcified neoatherosclerosis. Multivariable Cox regression revealed that female sex and lipidic neoatherosclerosis were associated with more target lesion failure, whereas stent age and final minimum lumen diameter after reintervention were related to lower target lesion failure. Calcified neoatherosclerosis was not related to adverse events after reintervention for in-stent restenosis given a large enough minimum lumen diameter was achieved. CONCLUSIONS: Lipidic but not calcified neoatherosclerosis was associated with poor subsequent outcomes after repeat revascularization if optimal stent expansion was achieved in lesions with calcified neoatherosclerosis.


Assuntos
Reestenose Coronária , Stents Farmacológicos , Insuficiência Renal , Constrição Patológica/etiologia , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/epidemiologia , Reestenose Coronária/etiologia , Stents Farmacológicos/efeitos adversos , Feminino , Humanos , Hiperplasia/etiologia , Lipídeos , Prevalência , Insuficiência Renal/etiologia , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 99(7): 2028-2037, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35419936

RESUMO

OBJECTIVES: The purpose of the current study was to use intravascular ultrasound (IVUS) to clarify anatomical and morphological lesion characteristics of uncrossable lesions. BACKGROUND: Uncrossable lesions are not always severely calcified. The prevalence of uncrossable lesions that are nonseverely calcified as well as other mechanisms for uncrossability has not been well clarified. METHODS: A total of 252 de novo uncrossable lesions in native coronary arteries that underwent either rotational or orbital atherectomy due to inability of any balloon to cross the lesion and 38 lesions with severe calcium in which IVUS crossed preatherectomy were included. Severe calcium is defined as maximum arc of calcium ≥270°. RESULTS: Severe calcification was absent in 16% of uncrossable lesions, 83% of which had a significant vessel bend. Compared with crossable lesions with severe calcium, uncrossable lesions with severe calcium more often had a bend in the vessel (71% vs. 21%, p < 0.001) and a longer length of continuous severe calcium (median length of calcium ≥270° 3.8 mm vs. 1.9 mm, p = 0.001). Other than severe calcium (especially long continuous calcium) or a bend in the vessel, anatomical factors associated with uncrossabilty were aorto-ostial lesion location and small vessels. CONCLUSIONS: Uncrossable lesions are not always severely calcified. The interaction of lesion morphology (continuous long and large arcs of calcium) and vessel geometry (bend in the vessel or ostial lesion location) affect lesion crossability.


Assuntos
Aterectomia Coronária , Doença da Artéria Coronariana , Calcificação Vascular , Aterectomia Coronária/efeitos adversos , Cálcio , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Resultado do Tratamento , Ultrassonografia de Intervenção , Calcificação Vascular/diagnóstico por imagem
10.
EuroIntervention ; 17(8): e647-e655, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33589409

RESUMO

BACKGROUND: Connecting the antegrade wire (AW) and the retrograde wire (RW) is a goal of chronic total occlusion (CTO) treatment, but angiographic guidewire location is sometimes misleading. AIMS: The aim of this study was to evaluate the association between intravascular ultrasound (IVUS)-defined AW and RW position and procedural outcomes when treating CTO lesions using the retrograde approach. METHODS: Overall, 191 CTO lesions treated using an IVUS-guided retrograde approach at three centres in Japan, China, and the USA were included. RESULTS: When the AW and RW angiographically overlapped, four wire positions were seen on IVUS: (i) AW within the plaque (AW-intraplaque) and RW-intraplaque in 34%; (ii) AW-intraplaque and RW in the subintimal space (RW-subintima) in 28%; (iii) AW-subintima and RW-subintima in 22%; or (iv) AW-subintima and RW-intraplaque in 16%. The procedure succeeded without repositioning the wire in 89% of AW-intraplaque/RW-intraplaque, 61% of AW-intraplaque/RW-subintima and 57% of AW-subintima/RW-subintima, but only one (3%) AW-subintima/RW-intraplaque. Lesion and procedure complexity and failure/complications were greatest in AW-subintima/RW-intraplaque. CONCLUSIONS: IVUS-identified vascular compartment concordance versus IVUS-identified vascular compartment mismatch leads to higher success rates irrespective of intraplaque or subintimal passage. AW-subintima/RW-intraplaque was associated with the most complex CTO morphology and procedure, and repositioning the wire was almost always necessary. Visual summary. When the antegrade wire is in the subintimal space and the retrograde wire is in the intraplaque, re-wiring is almost always necessary.


Assuntos
Oclusão Coronária , Placa Aterosclerótica , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/cirurgia , Humanos , Japão , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/cirurgia , Resultado do Tratamento , Ultrassonografia de Intervenção
11.
Clin Res Hepatol Gastroenterol ; 45(2): 101502, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32828748

RESUMO

BACKGROUND AND AIMS: Sub-Saharan Africa (SSA) is the region with the most patients co-infected with the human immunodeficiency virus (HIV) and the hepatitis B virus (HBV) worldwide. However, few studies have focused on SSA children who are at a higher risk of developing a chronic infection than adults. Furthermore, children on first-line antiretroviral therapy (ART) including low genetic barrier drugs may develop both HBV and HIV resistance mutations. The aim of this work was to document HIV-HBV co-infection and to characterize the HBV isolates in children in Senegal. METHODS: This is a retrospective study of 613 children infected with HIV on ART or not. Dried blood spot (DBS) specimens were used to detect hepatitis B surface antigen (HBsAg) with a rapid diagnostic test (RDT). Confirmation of HBsAg status and hepatitis B e antigen (HBeAg) detection was performed on an automated platform using the chemiluminescence assay technology. HBV viral DNA was quantified by real-time polymerase chain reaction (PCR) and the preS1/preS2/HBsAg region was genotyped by nested PCR followed by sequencing using the Sanger technique. RESULTS: The prevalence of HIV-HBV co-infection was 4.1% (25/613). The median age of co-infected children was 13 years (2 years-16 years) and 40% (10/25) were girls. Almost all 19/20 (95%) were infected with HIV-1 and 79% (19/24) were treated with 3TC-based triple combination ART. The median duration of time on ART was 15 months (3 months-80 months). More than half of the children 53% (9/17) were experiencing HIV virologic failure and 75% (6/8) had at least one HIV-related resistance-associated mutation (RAM). Of the six children with resistance, none of the three administered treatments were effective on HIV. Of the 25 co-infected children, 82% (18/22) were HBeAg-positive, while the median HBV viral load (VL) was 6.20 log10 IU/mL (24/25 patients), and 62,5% (10/16) of the children had a persistent HBV viremia. Combination of ART was the only factor associated with HBV viremia persistence. Amplification was successful in 15 out of 16 patients (rate of 94%), and the ensuing phylogenetic analysis revealed that eight strains (53%) belonged to genotype A and seven (47%) to genotype E. HBV-related 3TC RAMs were uncovered in 20% of these patients (3/15). HBsAg escape mutations were found in 20% of the children (3/15). CONCLUSIONS: Our results showed a high level of drug resistance mutations to both HIV and HBV, a significant level of HBsAg escape mutations, HBV DNA persistence and HIV virologic failure in co-infected children in Senegal. The HBV genotypes found were A and E.


Assuntos
Coinfecção , Infecções por HIV , Hepatite B , Adolescente , Coinfecção/epidemiologia , DNA Viral , Testes Diagnósticos de Rotina , Feminino , Infecções por HIV/complicações , Infecções por HIV/tratamento farmacológico , Infecções por HIV/epidemiologia , Hepatite B/complicações , Hepatite B/tratamento farmacológico , Hepatite B/epidemiologia , Antígenos de Superfície da Hepatite B , Antígenos E da Hepatite B , Vírus da Hepatite B/genética , Humanos , Lamivudina , Infecção Persistente , Filogenia , Prevalência , Estudos Retrospectivos , Senegal/epidemiologia , Viremia
12.
Interv Cardiol Clin ; 10(1): 75-85, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33223109

RESUMO

Chronic total occlusions remain among the most technically challenging lesions to treat percutaneously. Limitations of 2-dimensional angiography may further hinder successful treatment of these lesions. Intrasvascular ultrasound has a key role in percutaneous recanalization for a chronic total occlusion by providing key lesion characteristics, facilitating guidewire crossing, elucidating the intraplaque or extralaque path of the guidewire, optimizing lesion preparation, guiding stenting and identifying suboptimal results. Live visualization of the guidewire during crossing may reduce extraplaque wire tracking. This review describes the practical uses of intravascular imaging for commonly encountered scenarios when treating chronic total occlusions.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Angiografia Coronária , Oclusão Coronária/diagnóstico , Oclusão Coronária/cirurgia , Humanos , Resultado do Tratamento , Ultrassonografia de Intervenção
13.
EuroIntervention ; 16(4): e335-e343, 2020 07 17.
Artigo em Inglês | MEDLINE | ID: mdl-31403461

RESUMO

AIMS: The aim of this study was to use optical coherence tomography (OCT) to predict newly implanted stent expansion for treatment of in-stent restenosis (ISR). METHODS AND RESULTS: With OCT guidance, 143 ISR lesions were treated with a new stent. Stent underexpansion was defined as minimum stent area (MSA) <4.5 mm2 and MSA/average of reference lumen area <70%. New stent underexpansion was found in 33 lesions (23%). These had a smaller old stent MSA (4.13 [3.32-4.62] versus 5.18 [4.01-6.38] mm2, p=0.001), and had a higher prevalence of multiple old stent layers (51.5% versus 10.9%, p<0.001) and neointimal or peri-stent calcium (69.7% versus 37.3%, p=0.001) compared to those without new stent underexpansion. Old stent underexpansion, multiple layers of old stent, maximum calcium angle >180°, and maximum calcium thickness >0.5 mm were independently associated with new stent underexpansion. Patients with new stent underexpansion had a higher prevalence of major adverse cardiac events (35.5% vs 14.3%, p=0.009), mainly driven by a higher rate of myocardial infarction and target vessel revascularisation at two years. CONCLUSIONS: When re-stenting an ISR lesion, old stent underexpansion, the amount of neointimal or peri-stent calcium, and multiple old stent strut layers are important determinants of new stent underexpansion which is then associated with adverse long-term outcomes.


Assuntos
Reestenose Coronária/diagnóstico por imagem , Neointima , Stents , Tomografia de Coerência Óptica , Angiografia Coronária , Reestenose Coronária/cirurgia , Vasos Coronários , Humanos
14.
BMC Pediatr ; 19(1): 47, 2019 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-30722780

RESUMO

BACKGROUND: In Senegal in 2015, an estimated 4800 children were living with HIV, with 1200 receiving ARV treatment, of whom half had follow-up care in decentralized sites outside Dakar. However, until now no studies have determined the efficacy of pediatric treatment in decentralized settings, even though the emergence of viral resistance, particularly among children in Africa, is a well-known phenomenon. This study aimed to assess the virological status of HIV-infected children in all decentralized facilities to help improve access to quality care. METHODS: A cross-sectional epidemiological and virological study was conducted in all of Senegal's regions, except Dakar, between March and June 2015 and sought to include all HIV-infected children and adolescents (0-19 years), treated or not with ARVs. Socio-demographic and clinical data and a blood sample on blotting paper were collected for children from treatment sites. Samples were routed on public transportation, assisted by a network of community health workers. A viral load (VL) assay was performed for each child, followed by genotyping when it exceeded 1000 copies/mL (3 log10). RESULTS: Of the 851 identified children, 666 (78%) were enrolled in the study. Half of the children were girls, and the average age was 8 years (6 months-19 years). Most of the children (96.7%) were infected with HIV-1, and 90% were treated with ART, primarily with AZT + 3TC + NVP/EFV therapeutic regimen. The median duration of time on ART was 21 months (1-129). VL was measured for 2% of children before this study. Almost two-thirds (64%) of the children are experiencing virological failure. Among them, there was resistance to at least one drug for 86.5% of cases. Also, 25% children presented resistance to one drug and 40% to two out of three. For nearly one-third of the children presenting resistance, none of the three drugs of the treatment was active. Factors associated with virological failure were male sex, follow-up by a generalist rather than a specialist, and treatment interruptions. CONCLUSIONS: We observed a high level of virological failure and a high percentage of viral resistance among children receiving health care in decentralized facilities in Senegal.


Assuntos
Antirretrovirais/uso terapêutico , Farmacorresistência Viral , Infecções por HIV/tratamento farmacológico , Falha de Tratamento , Adolescente , Criança , Pré-Escolar , Estudos Transversais , Atenção à Saúde/organização & administração , Feminino , Infecções por HIV/epidemiologia , Humanos , Lactente , Masculino , Senegal/epidemiologia , Adulto Jovem
15.
Am J Cardiol ; 123(7): 1052-1059, 2019 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-30642605

RESUMO

Outcomes after percutaneous coronary interventions (PCI) in saphenous vein grafts (SVG) are inferior compared with native coronary arteries, but the mechanisms of SVG in-stent restenosis (ISR) have not been well-described. Thus, we aimed to evaluate the patterns of SVG ISR using intravascular ultrasound (IVUS) in 54 SVG ISR lesions. Stent underexpansion was defined as minimum stent area (MSA) <5 mm2. The time from stent implantation to presentation with ISR (9 BMS, 18 first-generation DES, and 27 second-generation DES) was 3.7 ± 3.0 years. IVUS-defined ISR patterns were categorized as mechanical (33%) or biological (67%). Mechanical patterns comprised 10 cases of stent underexpansion (MSA = 4.2 ± 0.9 mm2), 6 stent fractures or deformations, and 2 uncovered aorto-anastomotic lesions. Biological patterns comprised 19 cases of neoatherosclerosis, 13 excessive neointimal hyperplasia (NIH, 65 ± 11%), and 4 thrombi. Compared with biological patterns of ISR, mechanical patterns were more frequently located at the SVG anastomosis (72% vs 39%, p = 0.04) and at the SVG hinge motion site (55% vs 21%, p = 0.02). Although patients with mechanical patterns of ISR presented earlier than those with biological patterns (2.3 vs 4.4 years, p = 0.009), 61% of them were diagnosed >1 year after stent implantation. In conclusion, SVG ISR is dominated by biological patterns including neoatherosclerosis. Mechanical patterns of SVG ISR are associated with earlier presentation and location at graft anastomosis or hinge motion site.


Assuntos
Oclusão Coronária/cirurgia , Reestenose Coronária/diagnóstico , Vasos Coronários/cirurgia , Oclusão de Enxerto Vascular/diagnóstico , Intervenção Coronária Percutânea/efeitos adversos , Veia Safena/transplante , Ultrassonografia de Intervenção/métodos , Idoso , Angiografia Coronária , Oclusão Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Veia Safena/diagnóstico por imagem
16.
Catheter Cardiovasc Interv ; 93(6): 1048-1056, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30489684

RESUMO

OBJECTIVES: We sought to determine the 1-year outcomes of patients receiving successful chronic total occlusion (CTO) percutaneous coronary intervention (PCI) procedures comparing subintimal versus intraplaque wire tracking patterns. BACKGROUND: CTO PCI utilizes both intraluminal and subintimal wire tracking to achieve successful percutaneous revascularization. Intravascular ultrasound (IVUS) can be used to precisely determine the path of wire tracking. METHODS: From 2014 to 2016, data from patients undergoing CTO PCI were collected in a single-center database. The primary composite endpoint was target vessel failure (TVF) defined as cardiovascular death, target vessel myocardial infarction (MI), or target vessel revascularization (TVR). RESULTS: In total 157 patients with successful CTO PCI and concomitant IVUS imaging completed 1-year follow-up. Subintimal tracking was detected in 53.5% of cases and those patients had a higher incidence of prior PCI, prior coronary artery bypass grafting, and higher J-CTO score. At 1-year, the unadjusted rate of TVF in the subintimal tracking group was higher than the intraplaque group (17.9 vs. 6.9%, HR 2.74, 95% CI 1.00-7.54, P = 0.04), driven by numerically higher rates of TVR and peri-procedural MI. After multivariable adjustment, no significant differences in the rates of the TVF between subintimal vs. intraplaque groups were present at 1-year (TVF: HR 1.51, 95% CI 0.38-6.00, P = 0.55). Landmark analysis excluding in-hospital events showed no significant differences in TVF to 1-year. CONCLUSIONS: IVUS-detected subintimal tracking was observed in over half of successful CTO PCI cases and correlated with baseline and angiographic factors that contributed to the overall rate of TVF at 1-year.


Assuntos
Angioplastia Coronária com Balão , Oclusão Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Placa Aterosclerótica , Ultrassonografia de Intervenção , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/mortalidade , Oclusão Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Bases de Dados Factuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
JACC Case Rep ; 1(5): 774-780, 2019 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-34316930

RESUMO

Patients with chronic kidney disease are at elevated risk for adverse events after traditional coronary angiography and percutaneous intervention with contrast media. The case presented in this report highlights the potential benefits of zero-contrast multivessel percutaneous coronary intervention in a patient presenting with a non-ST-segment elevation acute coronary syndrome. (Level of Difficulty: Beginner.).

18.
EuroIntervention ; 14(4): e459-e466, 2018 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-29769168

RESUMO

AIMS: Among technologies used to assess FFR, a monorail, sensor-tipped micro pressure catheter (PC) may be advantageous for delivery and re-assessment. We sought to determine whether the larger cross-sectional area of the PC influences FFR measurements compared to the pressure wire. METHODS AND RESULTS: PERFORM was a single-centre, prospective study designed to determine the precision and accuracy of the PC compared with the pressure wire (PW) for measurement of FFR. Eligible patients had native coronary artery target lesions with visually estimated diameter stenosis of 40-90%. The independently adjudicated primary endpoint was the difference in hyperaemic PW-determined minimal FFR with and without the PC distal to the stenosis. Seventy-four patients (95 lesions) were prospectively analysed between December 2015 and December 2016. Median hyperaemic FFR was 0.84 (IQR 0.78, 0.89) with the PW and 0.79 (IQR 0.73, 0.85) with the PC distal to the stenosis (p<0.001). Such differences led to clinical discordance, whereby the PC decreased the hyperaemic PW-determined FFR from >0.80 to ≤0.80 in 17 of 95 measurements (19%). Median resting Pd/Pa was lower following introduction of the PC compared with the PW alone (0.93 [IQR 0.90, 0.97] versus 0.90 [IQR 0.86, 0.95], p<0.001). Median pressure drift was not different between the PW and the PC (0.01 [IQR -0.01, 0.05] versus 0.01 [IQR 0.00, 0.02], p=0.38). CONCLUSIONS: Introduction of the PC reduced both hyperaemic FFR and resting Pd/Pa compared with the PW alone, leading to re-classifying physiological significance to below the clinical threshold in one out of five assessments.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Hiperemia , Angiografia Coronária , Vasos Coronários , Humanos , Estudos Prospectivos
20.
Br Med Bull ; 125(1): 79-90, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-29360941

RESUMO

Background: Intracoronary imaging is an important tool for guiding decision making in the cardiac catheterization laboratory. Sources of data: We have reviewed the latest available evidence in the field to highlight the various potential benefits of intravascular imaging. Areas of agreement: Coronary angiography has been considered the gold standard test to appropriately diagnose and manage patients with coronary artery disease, but it has the inherent limitation of being a 2-dimensional x-ray lumenogram of a complex 3-dimensional vascular structure. Areas of controversy: There is well-established inter- and intra-observer variability in reporting coronary angiograms leading to potential variability in various management strategies. Intracoronary imaging improves the diagnostic accuracy while optimizing the results of an intervention. Utilization of intracoronary imaging modalities in routine practice however remains low worldwide. Increased costs, resources, time and expertise have been cited as explanations for low incorporation of these techniques. Growing points: Intracoronary imaging supplements and enhances an operator's decision-making ability based on detailed and objective lesion assessment rather than a subjective visual estimation. The benefits of intravascular imaging are becoming more profound as the complexity of cases suitable for revascularization increases. Areas timely for developing research: While the clinical benefits of intravascular ultrasound have been well validated, optical coherence tomography in comparison is a newer technology, with robust clinical trials assessing its clinical benefit are underway.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Ultrassonografia de Intervenção/métodos , Cateterismo Cardíaco/métodos , Humanos , Utilização de Procedimentos e Técnicas , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA