Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Int J Implant Dent ; 10(1): 12, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38480586

RESUMO

PURPOSE: The aim of this article is to evaluate to the masticatory function performance and Oral Health-related Quality of Life (OHRQoL) in implant-retained overdenture compared with different implant number placements in the edentulous mandible. METHODS: From 2013 to 2015, each patients received 3 implants (iSy-Implant, Camlog, Wimsheim, Germany) in intraforaminal mandible (34, 41/31, 44). After operation, inserted implants were gradually loaded and incorporated into an overdenture with a self-aligning attachment system (Locator abutments) in 3 + 3 + 3 months. Five checked points were performed chewing cycle test with multicolored chewing gum and OHIP-G14 questionnaire and a sum score questionnaire as following: pre-operation, one implant load (41/31), two implants loaded (33,43), three implants loaded and 1-year follow up. RESULT: A total of 10 patients with 30 implants were placed, the survival rate of the implants was 100% within 1-year follow-up. Regarding the masticatory function analysis, for the higher number of chewing cycles, the higher mixing rate was observed. After 1 year, the inter-mixing rate without significant changes was found compared to the time after three implants were loaded with attachment system. The mean value of OHIP-G14 was 30.4 preoperatively, 21.1 after loading the first locator, 10.7 after loading two locator abutments, and 3.2 after loading all three locator abutments. After 1 year, OHIP-G14 was 2.6 without significantly changed. The mean of the sum score was 15.5 preoperatively, 27.8 after activation of the first locator, 39.4 after activation of two locators, 46.2 after activation of all three locators, and 47.3 after 1 year. An increase of 0.7 sum score units per time point was observed. No significance was detectable, analogous to OHIP-G14, compared to the time of activation of all three locator setups (p-value = 0.22). CONCLUSIONS: A significant improvement in masticatory function performance and OHRQoL was evaluated with the increasing number of implants with locator attachment in edentulous mandible. With the investigation of the OHIP-G14 and sum score, the results of patient report outcome might be associated with the increase in the number of implants.


Assuntos
Implantes Dentários , Arcada Edêntula , Humanos , Seguimentos , Estudos Prospectivos , Revestimento de Dentadura , Qualidade de Vida , Arcada Edêntula/cirurgia , Mandíbula/cirurgia
2.
Clin Implant Dent Relat Res ; 26(2): 343-355, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38084831

RESUMO

INTRODUCTION: The objective of the study was to provide long-term clinical outcomes and complications in the severely atrophic edentulous maxillae treated by means of the quad zygoma protocol (QZP) using the Anatomy-Guided Approach (AGA). METHODS: This was a retrospective cohort study of all consecutive patients with severely atrophic edentulous maxilla and insufficient bone height and width in the anterior and posterior regions bilaterally, who underwent rehabilitation with the QZP between May 2006 and December 2021. All patients were followed for at least 1 year. All zygomatic implants (ZIs) were placed by the same surgeon. The primary endpoint of the study was the implant survival rate. Secondary endpoints were implant success rate, prosthesis success rate, complications, and Oral Health-Related Quality of Life using the OHIP-14 questionnaire. RESULTS: A total of 56 patients (men 16, women 40) with 224 ZIs (Nobel Biocare, n = 204; Straumann, n = 16; Southern Implant, n = 4) placement were included with a mean follow-up period 8.8 ± 3.9 years (range, 1.2-17.0). The survival (success) rate was 97.7%. Five ZIs in four patients failed. The mean time between implant placement and failure was 8.6 years (range, 0.5-13.3). All patients received immediate loading with acrylic prosthesis. The successful rates for the definitive prosthesis were 98.2%. Forty-two patients received posterior cantilever for rehabilitation of fixed definitive prosthesis. Local orofacial inflammation (35.7%) and Sinusitis (12.5%) were the most common complications, occurring at a mean follow-up of 10.0 (range, 4.2-14.9) and 10.3 (range, 4.3-16.2) years, respectively. In 48 patients, the mean score of the OHIP-14 questionnaire was 1.7 ± 2.6 with the follow-up period of 9.0 ± 4.1 years. CONCLUSIONS: The rehabilitation of severely atrophic edentulous maxilla using the QZP has shown a predictable and high survival rate in the long term. The implementation of an immediate loading protocol offers potential benefits in stabilizing ZIs with cross-arch stabilization. Moreover, the use of a posterior cantilever in reconstruction can effectively establish functional occlusion through well-distributed ZIs, eliminating the need for additional implant placement.


Assuntos
Implantes Dentários , Arcada Edêntula , Masculino , Humanos , Feminino , Implantação Dentária Endóssea/métodos , Implantes Dentários/efeitos adversos , Estudos Retrospectivos , Seguimentos , Maxila/cirurgia , Resultado do Tratamento , Zigoma/cirurgia , Qualidade de Vida , Arcada Edêntula/cirurgia , Arcada Edêntula/reabilitação , Prótese Dentária Fixada por Implante
3.
Int J Implant Dent ; 9(1): 28, 2023 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-37698775

RESUMO

OBJECTIVES: The aim of the ITI Consensus Workshop on zygomatic implants was to provide Consensus Statements and Clinical Recommendations for the use of zygomatic implants. MATERIALS AND METHODS: Three systematic reviews and one narrative review were written to address focused questions on (1) the indications for the use of zygomatic implants; (2) the survival rates and complications associated with surgery in zygomatic implant placement; (3) long-term survival rates of zygomatic implants and (4) the biomechanical principles involved when zygoma implants are placed under functional loads. Based on the reviews, three working groups then developed Consensus Statements and Clinical Recommendations. These were discussed in a plenary and finalized in Delphi rounds. RESULTS: A total of 21 Consensus Statements were developed from the systematic reviews. Additionally, the group developed 17 Clinical Recommendations based on the Consensus Statements and the combined expertise of the participants. CONCLUSIONS: Zygomatic implants are mainly indicated in cases with maxillary bone atrophy or deficiency. Long-term mean zygomatic implant survival was 96.2% [95% CI 93.8; 97.7] over a mean follow-up of 75.4 months (6.3 years) with a follow-up range of 36-141.6 months (3-11.8 years). Immediate loading showed a statistically significant increase in survival over delayed loading. Sinusitis presented with a total prevalence of 14.2% [95% CI 8.8; 22.0] over a mean 65.4 months follow-up, representing the most common complication which may lead to zygomatic implant loss. The international experts suggested clinical recommendations regarding planning, surgery, restoration, outcomes, and the patient's perspective.


Assuntos
Implantes Dentários , Humanos , Implantes Dentários/efeitos adversos , Redação , Atrofia , Consenso , Resultado do Tratamento
4.
J Clin Med ; 12(16)2023 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-37629460

RESUMO

PURPOSE: The present systematic review aimed to investigate the accuracy of zygomatic implant (ZI) placement using dynamic computer-aided surgery (d-CAIS), static computer-aided surgery (s-CAIS), and a free-hand approach in patients with severe atrophic edentulous maxilla and/or deficient maxilla. METHODS: Electronic and manual literature searches until May 2023 were performed in the PubMed/Medline, Scopus, Cochrane Library, and Web of Science databases. Clinical trials and cadaver studies were selected. The primary outcome was planned/placed deviation. Secondary outcomes were to evaluate the survival of ZI and surgical complications. Random-effects meta-analyses were conducted and meta-regression was utilized to compare fiducial registration amounts for d-CAIS and the different designs of s-CAIS. RESULTS: A total of 14 studies with 511 ZIs were included (Nobel Biocare: 274, Southern Implant: 42, SIN Implant: 16, non-mentioned: 179). The pooled mean ZI deviations from the d-CAIS group were 1.81 mm (95% CI: 1.34-2.29) at the entry point and 2.95 mm (95% CI: 1.66-4.24) at the apex point, and angular deviations were 3.49 degrees (95% CI: 2.04-4.93). The pooled mean ZI deviations from the s-CAIS group were 1.19 mm (95% CI: 0.83-1.54) at the entry point and 1.80 mm (95% CI: 1.10-2.50) at the apex point, and angular deviations were 2.15 degrees (95% CI: 1.43-2.88). The pooled mean ZI deviations from the free-hand group were 2.04 mm (95% CI: 1.69-2.39) at the entry point and 3.23 mm (95% CI: 2.34-4.12) at the apex point, and angular deviations were 4.92 degrees (95% CI: 3.86-5.98). There was strong evidence of differences in the average entry, apex, and angular deviation between the navigation, surgical guide, and free-hand groups (p < 0.01). A significant inverse correlation was observed between the number of fiducial screws and the planned/placed deviation regarding entry, apex, and angular measurements. CONCLUSION: Using d-CAIS and modified s-CAIS for ZI surgery has shown clinically acceptable outcomes regarding average entry, apex, and angular deviations. The maximal deviation values were predominantly observed in the conventional s-CAIS. Surgeons should be mindful of potential deviations and complications regardless of the decision making in different guide approaches.

5.
Int J Implant Dent ; 9(1): 18, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37400739

RESUMO

PURPOSE: To assess the body of evidence of short versus regular implants after bone augmentation (BA) in the atrophic posterior mandible in the context of implant treatment success outcomes. METHODS: Seven databases, two registries, and reference lists were searched for systematic reviews and meta-analysis (SR/MA), randomized controlled trials (RCTs) and longitudinal studies published in English, Spanish or German since 2012. Confidence in the SR/MA methodology was evaluated using AMSTAR-2 and the risk of bias of primary studies using Cochrane's RoB 2.0 and ROBINS-I. A random-effects meta-analysis and a meta-regression were performed for continuous and dichotomous outcomes. GRADE approach was used to assess the certainty of the evidence. RESULTS: Eighteen SRs/MAs, most of them "critically low" and "low" confidence with substantial overlap, included 14 relevant RCTs with a high risk of bias. A cohort study with moderate risk of bias was added. Quantitative synthesis of 595 implants and 281 hemiarches/patients indicates that the use of short implants (< 10 mm) compared to regular implants and BA may reduce implant failure at 1-year follow-up, and marginal bone loss (MBL) at 3-, 5-, and 8-year follow-up; is likely to reduce the risk of biological complications at 1-, 3-, 5-, and 8-year follow-up; and may be the patient's preferred alternative. There is a correlation between bone height, MBL and biological complications. CONCLUSIONS: The available evidence partially suggests that the use of short implants could decrease implant failure, MBL, and biological complications, and increase patient satisfaction. However, given the need for further RCTs and real-world evidence to fully evaluate short- and long-term outcomes, it would be prudent for clinicians to carefully consider the individual needs and circumstances of the patients before deciding whether to use short implants. Trial registration PROSPERO CRD42022333526.


Assuntos
Implantes Dentários , Humanos , Implantação Dentária Endóssea/métodos , Revisões Sistemáticas como Assunto , Resultado do Tratamento , Atrofia , Mandíbula/cirurgia
6.
Clin Oral Implants Res ; 34(9): 881-891, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37427881

RESUMO

AIM: To assess the correlation between the periodontal phenotype (PP) and sinus membrane thickness (SMT) in humans. METHODS: This review was conducted according to the PRISMA guidelines. Two reviewers independently carried out electronic and manual literature searches of studies published in English, German, and Spanish, from 1970 to September 2022 in four electronic databases, PubMed/Medline, Scopus, Cochrane Library, and Web of Science, in addition to gray literature. Studies that assessed the correlation between PP and SMT in adults (aged 18 years) were included. Methodological quality was evaluated using the Appraisal Tool for Cross-Sectional Studies (AXIS) for articles that met the eligibility criteria. RESULTS: Six studies, including 510 patients, were considered for qualitative analysis. All included studies were cross-sectional, and the correlation between the PP and SMT was evaluated, finding a positive and high correlation in 83.3% of them, based on a value of ≥0.7. All the included studies were assessed with a high overall risk of bias. CONCLUSIONS: Periodontal phenotype and sinus membrane thickness are likely correlated. Nevertheless, further standardized studies are required to draw definitive conclusions.


Assuntos
Membranas , Adulto , Humanos , Fenótipo
7.
Clin Implant Dent Relat Res ; 25(5): 892-909, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37337110

RESUMO

BACKGROUND: Screening ultrasonography was proposed for monitoring periodontal soft tissues in the early 1960s, owing to its nonionizing, real-time, and cost-effective properties. Studies have provided convincing preliminary evidence for the use of ultrasound (US) in implant dentistry. PURPOSE: To assess the feasibility of ultrasonography (US) for measuring the buccal thickness of periodontal and peri-implant tissues. The secondary objective was to evaluate the reliability of US measurements compared to classic techniques, such as CBCT and directly measurements. MATERIALS AND METHODS: An electronic literature search was conducted by three independent reviewers through February 2023. The inclusion criteria were articles investigating at least five patients/cadavers with US measurements in periodontal or peri-implant buccal tissues. Compliance with methodological reporting standards and risk of bias was assessed using EULAR and QUADAS-C tools, respectively. Random-effects meta-analysis was conducted, using Bland-Altman analysis. Certainty of the evidence was assessed using GRADE. RESULTS: The final selection included 12 studies examining 458 patients and 13 cadavers, with a total of 226 implants, 1958 teeth and 60 edentulous sites. The body of evidence was assessed as partially compliant with methodological reporting standards for US studies and had an unclear to high risk of bias. Meta-analysis of five comparative studies showed no evidence of clinically significant bias between US and direct measurements (very low certainty), and between US and CBCT (very low certainty) for soft-tissue thickness. Likewise, for bone thickness, there is no evidence of clinically significant bias between US and CBCT (low certainty). CONCLUSIONS: Compared to the CBCT and direct measurements, ultrasonography might be a reliable approach for monitoring on periodontal and peri-implant phenotype. However, there is uncertainty about estimates of the actual effect, so further standardized and larger sample size of clinical research is needed.


Assuntos
Implantes Dentários , Humanos , Estudos de Viabilidade , Reprodutibilidade dos Testes , Ultrassonografia , Cadáver
8.
Int J Implant Dent ; 9(1): 11, 2023 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-37198345

RESUMO

PURPOSE: To assess the outcome [zygomatic implant (ZI) survival] and complications of the original surgical technique (OST) and an Anatomy-Guided approach (AGA) in the placement of ZI in patients with severely atrophic maxillae. METHODS: Two independent reviewers conducted an electronic literature search from January 2000 to August 2022. The inclusion criteria were articles reporting at least five patients with severely atrophic edentulous maxilla undergoing placement OST and/or AGA, with a minimum of 6 months of follow-up. Number of patients, defect characteristics, number of ZI, implant details, surgical technique, survival rate, loading protocol, prosthetic rehabilitation, complications, and follow-up period were compared. RESULTS: Twenty-four studies comprised 2194 ZI in 918 patients with 41 failures. The ZI survival rate was 90.3-100% in OST and 90.4-100% in AGA. Probability of complications with ZI with OST was as follows: sinusitis, 9.53%; soft tissue infection, 7.50%; paresthesia, 10.78%; oroantral fistulas, 4.58%; and direct surgical complication, 6.91%. With AGA, the presenting complications were as follows: sinusitis, 4.39%; soft tissue infection, 4.35%; paresthesia, 0.55%; oroantral fistulas, 1.71%; and direct surgical complication, 1.60%. The prevalence of immediate loading protocol was 22.3% in OST and 89.6% in the AGA. Due to the heterogeneity of studies, statistical comparison was only possible after the descriptive analysis. CONCLUSIONS: Based on the current systematic review, placing ZI in severely atrophic edentulous maxillae rehabilitation with the OST and AGA is associated with a high implant survival rate and surgical complications within a minimum of 6 months follow-up. Complications, including sinusitis and soft tissue infection around the implant, are the most common. The utilization of immediate loading protocol is more observed in AGA than in OST.


Assuntos
Implantação Dentária Endóssea , Implantes Dentários , Arcada Edêntula , Maxila , Procedimentos Cirúrgicos Ortognáticos , Complicações Pós-Operatórias , Humanos , Implantes Dentários/efeitos adversos , Implantação Dentária Endóssea/efeitos adversos , Maxila/anormalidades , Maxila/cirurgia , Arcada Edêntula/mortalidade , Arcada Edêntula/reabilitação , Taxa de Sobrevida , Resultado do Tratamento , Sinusite , Infecções dos Tecidos Moles , Procedimentos Cirúrgicos Ortognáticos/efeitos adversos , Masculino , Feminino , Pré-Escolar , Criança , Adulto , Pessoa de Meia-Idade , Idoso
9.
Int J Oral Maxillofac Implants ; 38(2): 367-373, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37083908

RESUMO

Purpose: Zygomatic implants (ZIs) have been considered a reliable alternative treatment for patients with maxillary atrophy and/or maxillary defects. The use of a navigation system for assisting ZI placement could be a reliable approach for enhancing accuracy and safety. The purpose of this in vitro study was to evaluate the accuracy of a new dynamic surgical navigation system with its minimally invasive registration guide for quad zygomatic implant placement in comparison with a gold standard navigation approach. Materials and Methods: A total of 40 zygomatic implants were placed in 10 3D-printed models based on the CBCT scans of edentulous patients. For registration, a surgical registration guide with a quick response plate was used for the test group, and five hemispheric cavities as registered miniscrews in the intraoral area were used for the control group. In each model, a split-mouth approach was employed (two ZIs in bilateral zygomata) to test both systems. After ZI placement, a CBCT scan was performed and merged with pre-interventional planning. The deviations between planned and placed implants were calculated as offset basis, offset apical, and angular deviation and compared between the systems. Results: The offset basis, offset apical, and angular deviation were 1.43 ± 0.55 mm, 1.81 ± 0.68 mm, and 2.32 ± 1.59 degrees in the test group, respectively. For the control group, values of 1.48 ± 0.57 mm, 1.76 ± 0.62 mm, and 2.57 ± 1.51 degrees were measured without significant differences between groups (all P < .05). The accuracy of ZI positions (anterior and posterior) were measured without significant differences between groups. Conclusion: Two navigation systems with different registration techniques seem to achieve comparable acceptable accuracy for dynamic navigation of zygomatic implant placement. With the test group system, additional pre-interventional radiologic imaging and invasive fiducial marker insertion could be avoided.


Assuntos
Implantes Dentários , Boca Edêntula , Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/métodos , Implantação Dentária Endóssea/métodos , Marcadores Fiduciais , Tomografia Computadorizada de Feixe Cônico , Desenho Assistido por Computador , Imageamento Tridimensional
10.
Int J Implant Dent ; 9(1): 9, 2023 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-36971973

RESUMO

PURPOSE: The study aims to use cone beam computed tomography (CBCT) to (1) define the virtual valid length of pterygoid implants in maxillary atrophic patients from the prosthetic prioritized driven position and (2) measure the implant length engaged in the pterygoid process according to the HU difference of the pterygoid maxillary junction. MATERIALS AND METHODS: Virtual pterygoid implants were planned with CBCT of maxillary atrophic patients in the software. The entry and angulation of the implant were planned according to the prosthetic prioritized driven position in the 3D reconstruction image. The planned implant length and the valid length defined as the implant between the pterygoid maxillary junction and pterygoid fossa were recorded. The relationship between the implant and sinus cavity was also evaluated. RESULTS: A total of 120 CBCT samples were enrolled and virtually planned. The mean age of the patients was 56.2 ± 13.2 years. One hundred and sixteen samples could successfully place virtual implants according to the criterion. The mean implant length and mean implant length beyond the pterygoid maxillary junction were 16.3 ± 4.2 mm (range, 11.5-18 mm) and 7.1 ± 3.3 mm (range, 1.5-11.4 mm), respectively. Ninety percent of virtually planned implants had a close relationship with the sinus cavity, and implants exhibited longer lengths when they had no relation with the sinus. CONCLUSION: From a prosthetic prioritized driven position with fixed entry and angulation, pterygoid implants achieve adequate bone anchorage length beyond the pterygoid maxillary junction. Due to the individual anatomy and the volume of the maxillary sinus, the implants presented a different positional relationship with the maxillary sinus.


Assuntos
Implantes Dentários , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Implantação Dentária Endóssea/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Seio Maxilar/diagnóstico por imagem , Seio Maxilar/cirurgia , Maxila/diagnóstico por imagem , Maxila/cirurgia , Atrofia
11.
Clin Implant Dent Relat Res ; 24(4): 435-443, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35605154

RESUMO

BACKGROUND: Zygomatic implants (ZIs) that are anchored in remote locations can significantly improve the retention and stability of prosthetic obturation in maxillary defect sites without the need for complex surgical reconstruction. However, ZI placement without alveolar bone guidance is challenging, especially when identifying the ideal three-dimensional location of the "coronal part" of the implant fixture for further rehabilitation. PURPOSE: To investigate the feasibility and accuracy of surgical navigation for ZI placement using prosthetically driven plans to treat extensive maxillary defects. MATERIAL AND METHODS: Software was used to virtually plan the number and distribution of ZIs for maxillary defect patients according to the existing residual maxillofacial bone. The "coronal part" of the ZI was identified based on the existing maxillodental prosthetic flange, virtually planned infrastructure framework and superstructure. ZI placement was fully guided by surgical navigation. RESULTS: Ten patients were enrolled. One patient had loose reflective spheres, which resulted in an inaccurate back-reflection of the position during navigation. A total of 27 ZIs in the remaining 9 patients were placed uneventfully. The mean of the "coronal part" of the ZI, entry point of the zygomatic bone, apical deviation, and apical angle deviation were 1.50 mm, 1.39 mm, 1.95 mm, and 2.32°, respectively. A Computer-aided design and computer-aided manufacture milled bar and additional attachments were fabricated according to preoperative planning. No osseointegrated implant loss was detected. Six ZIs in three patients received implant surface polishing to reduce soft tissue irritation, and one ZI was submerged. DISCUSSION: Surgical navigation facilitated the accurate and feasible placement of prosthetically driven ZIs that were preoperatively planned in patients with extensive maxillary defects.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Desenho Assistido por Computador , Implantação Dentária Endóssea/métodos , Humanos , Maxila/cirurgia , Zigoma/cirurgia
12.
Int J Oral Maxillofac Implants ; 36(1): Ie1-e6, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33600540

RESUMO

This case report demonstrates the use of dynamic navigation guidance for bone reduction. Information about smile line position incorporated in a virtual plan and accurate transfer to the surgical field enhances the predictability of the treatment. A virtual wax-up was made, and implant positions along with bone reduction were planned accordingly. Residual teeth in the maxilla were extracted, and bone reduction and zygomatic implant placement were assisted by surgical navigation, while conventional implants were placed using the surgical template, followed by immediate loading. When surgical navigation is used for implant placement, navigated bone reduction can easily be incorporated in the workflow. The accuracy of bone reduction was evaluated together with the accuracy of two zygomatic implants assisted by a navigation system and four conventional implants assisted by a static template. The mean deviation between planned and performed bone reduction was 1.3 ± 0.39 mm (range: 0.8 to 1.7 mm). The accuracy of this procedure corresponds to the accuracy of guided implant placement and can be considered reliable after confirmation through clinical trials.


Assuntos
Implantes Dentários , Procedimentos de Cirurgia Plástica , Cirurgia Assistida por Computador , Implantação Dentária Endóssea , Humanos , Maxila/diagnóstico por imagem , Maxila/cirurgia , Fluxo de Trabalho
13.
Int J Comput Assist Radiol Surg ; 15(10): 1685-1692, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32715383

RESUMO

PURPOSE: Robot-world calibration, used to precisely determine the spatial relation between optical tracker and robot, is regarded as an essential step for optical-navigated surgical robot system to improve the surgical accuracy. However, these methods are complicated with numerous computation. Therefore, a more efficient method of a robot-world calibration is necessary. METHODS: A fully automatic robot-world calibration was proposed and applied in a surgical robot system for oral implant placement. Making full usage of the movement characteristics of a tandem robot, the least square fitting algorithm was implemented to calculate the relationship between the tool center point of the robot and the robot reference frame, with the robot-world calibration matrix obtained as result. RESULTS: The experiment was designed to verify the accuracy of the robot-world calibration. The average distance deviation was 1.11 mm, and the average angle deviation was 0.99°. From the animal experiment on the pig maxilla, the entry, apical and angle deviation of the surgical robot system were 1.44 ± 1.01 mm, 1.68 ± 0.76 mm, 1.01 ± 1.06°, respectively. CONCLUSION: The surgical robot system for oral implant placement with our robot-world calibration maintains a high precision. Besides, the operation range of the surgical tool is no longer limited by the visual range of the optical tracking device. Hence, it is unnecessary to adjust the optical tracking device for the planned implant trajectories to different positions and directions.


Assuntos
Implantes Dentários , Maxila/cirurgia , Dispositivos Ópticos , Robótica/instrumentação , Cirurgia Assistida por Computador/instrumentação , Algoritmos , Animais , Calibragem , Imagens de Fantasmas , Suínos
14.
Med Eng Phys ; 75: 72-78, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31677890

RESUMO

Zygomatic implant technology has been regarded as an alternative treatment to massive grafting surgery in the severe atrophic maxillary. Nowadays, the assistant method with a real-time surgical navigation has been applied to reduce the risks of zygomatic implant placement. However, the accuracy of the complex operation is highly dependent on the experience of the surgeon. In order to avoid disadvantages of traditional surgical navigation systems, a novel surgical robot system for the zygomatic implant placement has been designed and developed. Firstly, the drilling trajectory of the zygomatic implant placement is designed through the pre-operative planning system. Secondly, the real-time positions of the surgical instruments are constantly updated with the guidance of the optical tracker. Finally, through a coordinate transformation algorithm, the drilling performance can be conducted with the control of a six degree of freedom robot. In order to evaluate the accuracy of the robot, phantom experiments had been carried out. The angle, entry point and exit point deviation of the robotic system are 1.52 ±â€¯0.58°, 0.79 ±â€¯0.19 mm, and 1.49 ±â€¯0.48 mm, respectively. Meanwhile, a comparison between the robotic and manual operation demonstrates that the use of the surgical robot system for the zygomatic implant placement can improve the accuracy of the operation.


Assuntos
Maxila/cirurgia , Próteses e Implantes , Procedimentos Cirúrgicos Robóticos/métodos , Imagens de Fantasmas , Projetos Piloto , Procedimentos Cirúrgicos Robóticos/instrumentação
15.
Oral Maxillofac Surg Clin North Am ; 31(3): 513-518, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31103316

RESUMO

Robotic surgery is no longer a fiction and its clinical applications are rapidly developing. Robotic surgery is increasingly used because of its minimal invasiveness. This article provides an overview of robotic surgery and its current applications in oral and maxillofacial surgery and implant dentistry. Robotic surgery is constantly evolving, and its applications are continuously expanding. Recently, robot-assisted surgery has been used for dental implant placement. In the United States, the first robotic dental surgery system was cleared by the Food and Drug Administration for dental implant procedures in 2017. At the end of 2017, the world's first autonomous dental implant placement system was developed by Zhao and colleagues in China. This so-called intelligent robot has a high degree of autonomy, can automatically adjust during intraoperative procedures, and can execute surgical tasks directly on patients without any apparent control by a surgeon.


Assuntos
Implantes Dentários , Procedimentos Cirúrgicos Robóticos , Robótica , Cirurgia Assistida por Computador , Competência Clínica , Humanos , Cirurgia Assistida por Computador/instrumentação , Estados Unidos
16.
Oral Maxillofac Surg Clin North Am ; 31(3): 357-367, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31113696

RESUMO

Zygomatic implant placement has been shown to be a reliable method to reconstruct severe maxillary atrophy and maxillary deficiency defects. The placement of zygomatic implants is more complex and more challenging than conventional oral implant placement especially in the quad approach. The application of navigation surgery in complex craniomaxillofacial procedures has become very helpful in transferring the surgical plan to the patient and avoiding adjacent anatomic injuries. This article shows the feasibility of real-time navigation in zygomatic implant placement via building a clear workflow.


Assuntos
Implantes Dentários , Arcada Edêntula , Maxila/cirurgia , Zigoma/cirurgia , Implantação Dentária Endóssea , Prótese Dentária Fixada por Implante , Humanos , Fluxo de Trabalho
17.
Int J Comput Assist Radiol Surg ; 14(2): 281-289, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30317436

RESUMO

PURPOSE: Surgical navigation system (SNS) has been an important tool in surgery. However, the complicated and tedious manual selection of fiducial points on preoperative images for registration affects operational efficiency to large extent. In this study, an oral and maxillofacial navigation system named BeiDou-SNS with automatic identification of fiducial points was developed and demonstrated. METHODS: To solve the fiducial selection problem, a novel method of automatic localization for titanium screw markers in preoperative images is proposed on the basis of a sequence of two local mean-shift segmentation including removal of metal artifacts. The operation of the BeiDou-SNS consists of the following key steps: The selection of fiducial points, the calibration of surgical instruments, and the registration of patient space and image space. Eight cases of patients with titanium screws as fiducial markers were carried out to analyze the accuracy of the automatic fiducial point localization algorithm. Finally, a complete phantom experiment of zygomatic implant placement surgery was performed to evaluate the whole performance of BeiDou-SNS. RESULTS AND CONCLUSION: The coverage of Euclidean distances between fiducial marker positions selected automatically and those selected manually by an experienced dentist for all eight cases ranged from 0.373 to 0.847 mm. Four implants were inserted into the 3D-printed model under the guide of BeiDou-SNS. And the maximal deviations between the actual and planned implant were 1.328 mm and 2.326 mm, respectively, for the entry and end point while the angular deviation ranged from 1.094° to 2.395°. The results demonstrate that the oral surgical navigation system with automatic identification of fiducial points can meet the requirements of the clinical surgeries.


Assuntos
Implantação Dentária Endóssea/métodos , Marcadores Fiduciais , Processamento de Imagem Assistida por Computador/métodos , Maxila/cirurgia , Cirurgia Assistida por Computador/métodos , Idoso , Algoritmos , Parafusos Ósseos , Calibragem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Boca Edêntula/cirurgia , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos
18.
Int J Oral Maxillofac Implants ; 34(1): 85­90, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30521651

RESUMO

PURPOSE: Real-time surgical navigation has been increasingly applied in implant placement. The initial registration procedures were found to substantially affect the overall accuracy of the system for zygomatic implant placement, but the exact number and distribution of fiducial markers was yet undetermined. This study aimed to determine the minimal numbers and optimal distributions of fiducial markers to achieve clinically acceptable accuracy in surgical navigation, through systematically analyzing the effects of different setups of fiducial markers on target registration errors (TRE). MATERIALS AND METHODS: A maxillary phantom with bone-anchored fiducial markers was scanned using cone beam computed tomography, followed by data processing on Brainlab, a commercially available navigation system. A total of 10 mini-screws were inserted in the edentulous maxilla for configuration of fiducial markers, with another two mini-screws as implant targets to assess TRE in zygomatic bone. Data were then collected in nine configurations with distinct fiducial numbers and positions. Statistical analyses were performed with SPSS. RESULTS: Accuracy of the surgical navigation system was found to depend on both the numbers and positions of fiducial markers. No significant difference was observed in accuracy among groups with eight fiducials and with polygon span distribution (P > .05). When the fiducial numbers decreased to less than six, the markers inserted in a regular triangle area were more precise than in an inverse triangle configuration. When the number of fiducials was five with a polygonal distribution, a low TRE value of 0.59 mm was detected, which was comparable to the accuracy with more than eight fiducials in the study. CONCLUSION: A scattered distribution with a polygon span with at least five fiducial markers in the edentulous maxilla for registration seems to achieve an acceptable TRE value with a high accuracy for navigation in zygomatic implant placement.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Implantação Dentária Endóssea/métodos , Implantes Dentários , Marcadores Fiduciais , Processamento de Imagem Assistida por Computador , Arcada Edêntula/cirurgia , Cirurgia Assistida por Computador/métodos , Zigoma/cirurgia , Humanos , Arcada Edêntula/reabilitação , Maxila/cirurgia , Imagens de Fantasmas
19.
Clin Oral Implants Res ; 29(7): 679-687, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29774595

RESUMO

OBJECTIVES: The purpose of this retrospective study was to evaluate the long-term changes in the thickness of Schneiderian membranes after zygomatic implant placement using cone beam computed tomography (CBCT). MATERIAL AND METHODS: Twenty-five consecutive patients were included in this study. All the patients underwent bilateral zygomatic implant placement. Schneiderian membrane thickness (SMT) in 49 maxillary sinuses (one sinus was not included because of early loss of the zygomatic implants) was measured using CBCT before and at least 1 year after zygomatic implant placement. Ostium patency of each sinus was also evaluated and recorded. RESULTS: In total, 84 zygomatic implants and 30 regular implants were placed in included patients. Two unilateral maxillary zygomatic implants in one patient were removed 2 months after implant placement. The SMT increased from 1.03 mm (inter-quartile range: 1.57 mm) to 1.33 mm (inter-quartile range: 1.98 mm) after a median follow-up time of 23.00 months (inter-quartile range: 14 months), and the difference was statistically significant. Before zygomatic implant insertion, 24.5% (12/49) of sinuses had SMT greater than 2 mm, whereas this value was 28.6% (14/49) after zygomatic implant placement. The percentage of sinuses observed with ostium patency also increased from 2.0% (1/49) to 12.2% (6/49). CONCLUSIONS: Chronic Schneiderian membrane thickening could result from zygomatic implant insertion. Intensive postoperative care and clinical and radiographic monitoring are recommended after zygomatic implant placement.


Assuntos
Implantação Dentária Endóssea/efeitos adversos , Mucosa Nasal/diagnóstico por imagem , Zigoma/cirurgia , Adulto , Idoso , Tomografia Computadorizada de Feixe Cônico , Implantes Dentários/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mucosa Nasal/patologia , Estudos Retrospectivos , Adulto Jovem , Zigoma/diagnóstico por imagem
20.
J Oral Maxillofac Surg ; 76(1): 80-87, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28911958

RESUMO

PURPOSE: Computer-aided treatment technology has extended its applications to oral implantology. This report describes the authors' initial clinical experience on the application of a commercially available navigation system (VectorVision) in zygomatic implant (ZI) insertion in the severely atrophic maxilla. MATERIALS AND METHODS: This was a retrospective longitudinal study. Eligible patients with maxillary edentulism who were treated with ZI placement were enrolled. Treatment planning was performed on the computer based on previously obtained 3-dimensional imaging data. The surgical procedure was carried out under the guidance of a surgical navigation system. The outcome variable was safety and additional variables were ZI survival rate and radiologic bone-to-implant contact (rBIC) area in the zygoma. Statistical analysis was performed with SPSS 16.0 for Windows (SPSS, Inc, Chicago, IL). RESULTS: Fifteen patients (8 men, 7 women; age range, 30 to 69 yr; average age, 43 ± 3.5 yr) were eligible for the study and were enrolled from May 2015 through September 2016. Of the included patients, each of 4 patients received 1 ZI on each side of the zygomatic bone and 2 to 4 standard implants in the edentulous anterior maxilla; the other 11 received a ZI "quad approach" without standard implant insertion. All ZIs were anchored in the site of the maxillary alveolar process and zygomatic bone, and no critical anatomic structure injuries occurred during insertion and postoperative radiographic examination. All ZIs achieved osseointegration, for an overall survival rate of 100% after early healing. The overall rBIC area of ZIs in the study was 4.1 to 24.7 mm (average, 14.5 ± 4.6 mm). CONCLUSION: For the limited clinical cases treated in this study, the procedure for ZI placement was feasible and reliable with the guidance of the surgical navigation system. In addition, the potential risk of complications was minimized and ZIs were placed to make the best possible use of the available bone volume.


Assuntos
Implantação Dentária Endóssea/métodos , Implantes Dentários , Maxila/cirurgia , Cirurgia Assistida por Computador , Zigoma/cirurgia , Adulto , Idoso , Feminino , Humanos , Arcada Edêntula/cirurgia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA